Dynamics¶
All card families and alphabetical index
Read field positions from left to right within each table. A dash means the layout supplies no fixed default. Use a consistent system of units for dimensional quantities.
AcousticSourceLoad¶
An acoustic source given as power against frequency.
Record format and fields
AcousticSourceLoad;id;excitationId;delayId;delay;phaseId;phase;powerTableId;power;density;bulkModulus
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Identifier addressing excitation set data. |
3 |
|
|
— |
Identifier selecting the delay record or set. Alternative to |
4 |
|
|
0.0 |
Time shift relative to the reference excitation, in model time units. Alternative to |
5 |
|
|
— |
Identifier selecting the phase record or set. Alternative to |
6 |
|
|
0.0 |
Phase of the harmonic quantity relative to the reference oscillation. Alternative to |
7 |
|
|
— |
Table supplying the variation of power. Alternative to |
8 |
|
|
— |
Exponent applied to the dependent relation. Alternative to |
9 |
|
|
Required |
Mass per unit volume for a volumetric material or fluid density. |
10 |
|
|
Required |
Resistance to volumetric compression, expressed as pressure. |
Accepted words: Acceleration, Displacement, Load, Velocity.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the dynamic load set ID must be a positive integer.
Example record
AcousticSourceLoad;30;31;;2.E-4;;10.;34;;1.2E-12;0.142
Reading the example gives id = 30, excitationId = 31, delay = 2.E-4, phase = 10..
BucklingEigenMethod¶
Specifies the extraction data for a buckling eigenvalue problem.
Record format and fields
BucklingEigenMethod;id;method;lowerEigenvalue;upperEigenvalue;estimatedModeCount;desiredPositiveModeCount;desiredNegativeModeCount;norm;normNode;normComponent
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the method namespace. |
2 |
|
|
— |
Selects the method for BucklingEigenMethod. |
3 |
|
|
Required |
Lower bound of the eigenvalue interval to search. |
4 |
|
|
Required |
Upper bound of the eigenvalue interval to search. |
5 |
|
|
0 |
Number of estimated mode entries. |
6 |
|
|
— |
Number of desired positive mode entries. |
7 |
|
|
— |
Number of desired negative mode entries. |
8 |
|
|
— |
Norm used for scaling a mode shape. |
9 |
|
|
0 |
Identifier addressing scalar or grid point data. |
10 |
|
|
0 |
Degree of freedom used as the normalization reference. |
Accepted words: InverseIteration, Maximum, Point, SturmInverse.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the method ID must be a positive integer.
Example record
BucklingEigenMethod;30;SturmInverse;0.;50.;;2;;Maximum
Reading the example gives id = 30, method = SturmInverse, lowerEigenvalue = 0., upperEigenvalue = 50..
ComplexEigenMethod¶
The data of a complex eigenvalue extraction.
Record format and fields
ComplexEigenMethod;id;methodName;norm;normNode;normComponent;convergenceTolerance;desiredModeCount0;<regions>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
— |
Text naming the method. |
3 |
|
|
Maximum |
Norm used for scaling a mode shape. |
4 |
|
|
0 |
Identifier addressing scalar or grid point data. |
5 |
|
|
0 |
Degree of freedom used as the normalization reference. |
6 |
|
|
— |
Permitted numerical deviation for convergence. |
7 |
|
|
0 |
Number of desired mode entries. |
Repeated group regions. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
The real part of the region’s first end point, or of the shift point. |
2 |
|
|
— |
The imaginary part. |
3 |
|
|
— |
The second end point (region form). |
4 |
|
|
— |
Angular-frequency term associated with the second frequency parameter of the relation. |
5 |
|
|
— |
Region width (length). |
6 |
|
|
— |
Number of estimated mode entries. |
7 |
|
|
— |
Number of desired mode entries. |
Accepted words: ComplexLanczos, DeterminantMethod, HessenbergMethod, ImplicitRestartedArnoldi, InverseIteration, Maximum, Point.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the method ID must be a positive integer.alphaA— the coordinates of a search region must be finite numbers.
Example record
ComplexEigenMethod;40;InverseIteration;Maximum;;;;;0.;0.;0.;3.E+3;500.;4;4
Reading the example gives id = 40, methodName = InverseIteration, norm = Maximum.
ComplexEigenPoles¶
Supplies one or two poles for the determinant-based complex eigenvalue method.
Record format and fields
ComplexEigenPoles;id;realPart1;imaginaryPart1;multiplicity1;realPart2;imaginaryPart2;multiplicity2
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
In-phase component of the complex quantity. Entry 1. |
3 |
|
|
Required |
Quadrature component of the complex quantity. Entry 1. |
4 |
|
|
Required |
Number of times the corresponding root or contribution is represented. Entry 1. |
5 |
|
|
Required |
In-phase component of the complex quantity. Entry 2. |
6 |
|
|
Required |
Quadrature component of the complex quantity. Entry 2. |
7 |
|
|
Required |
Number of times the corresponding root or contribution is represented. Entry 2. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the set ID must be a positive integer.realPart1— the coordinates of a pole must be finite numbers.realPart2— the coordinates of a pole must be finite numbers.
Example record
ComplexEigenPoles;40;-10.;0.;1;-10.;500.;1
Reading the example gives id = 40, realPart1 = -10., imaginaryPart1 = 0., multiplicity1 = 1.
DynamicLoadCombination¶
A dynamic load made of other dynamic load sets, combined linearly.
Record format and fields
DynamicLoadCombination;id;scaleFactor;<terms>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Multiplier applied to the quantity specified by the entry. |
Repeated group terms. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Multiplier for term scale. |
2 |
|
|
— |
Identifier selecting the load set record or set. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the dynamic load set ID must be a positive integer.scaleFactor1— the card needs at least one dynamic load set.loadSetId1— a dynamic load set ID must be a positive integer.loadSetId1— the card cannot refer to its own set ID.
Example record
DynamicLoadCombination;1;1.;1.;31;1.;32
Reading the example gives id = 1, scaleFactor = 1..
DynamicLoadDelay¶
Time delays of a dynamic load on one or two degrees of freedom.
Record format and fields
DynamicLoadDelay;id;point1;components1;delay1;point2;components2;delay2
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Identifier addressing node data. |
3 |
|
|
0 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1. |
4 |
|
|
Required |
Time shift relative to the reference excitation, in model time units. Entry 1. |
5 |
|
|
Required |
Identifier addressing node data. |
6 |
|
|
0 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2. |
7 |
|
|
Required |
Time shift relative to the reference excitation, in model time units. Entry 2. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the set ID must be a positive integer.point1— the point ID must be a positive integer.point2— the point ID must be a positive integer.
Example record
DynamicLoadDelay;22;15;3;5.E-4
Reading the example gives id = 22, point1 = 15, components1 = 3, delay1 = 5.E-4.
DynamicLoadPhase¶
Phase leads of a dynamic load on one or two degrees of freedom.
Record format and fields
DynamicLoadPhase;id;point1;components1;phaseAngle1;point2;components2;phaseAngle2
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Identifier addressing node data. |
3 |
|
|
0 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1. |
4 |
|
|
Required |
Angular phase offset relative to the reference excitation. Entry 1. |
5 |
|
|
Required |
Identifier addressing node data. |
6 |
|
|
0 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2. |
7 |
|
|
Required |
Angular phase offset relative to the reference excitation. Entry 2. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the set ID must be a positive integer.point1— the point ID must be a positive integer.point2— the point ID must be a positive integer.
Example record
DynamicLoadPhase;23;15;3;30.
Reading the example gives id = 23, point1 = 15, components1 = 3, phaseAngle1 = 30..
DynamicLoadScale¶
Scale (area) factors of a load on one or two degrees of freedom.
Record format and fields
DynamicLoadScale;id;point1;components1;scaleFactor1;point2;components2;scaleFactor2
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Identifier addressing node data. |
3 |
|
|
0 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1. |
4 |
|
|
Required |
Multiplier applied to the quantity specified by the entry. Entry 1. |
5 |
|
|
Required |
Identifier addressing node data. |
6 |
|
|
0 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2. |
7 |
|
|
Required |
Multiplier applied to the quantity specified by the entry. Entry 2. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the set ID must be a positive integer.point1— the point ID must be a positive integer.point2— the point ID must be a positive integer.
Example record
DynamicLoadScale;41;102;1;1.;213;3;1.
Reading the example gives id = 41, point1 = 102, components1 = 1, scaleFactor1 = 1..
Referenced records in this example
Node via
point1 = 102,point2 = 213.
FreqBetweenModes3¶
Excitation frequencies between the modal frequencies of a range (modal frequency response).
Record format and fields
FreqBetweenModes3;id;frequency1;frequency2;kind;frequencyCount;clustering
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Number of cycles per unit time. Entry 1. |
3 |
|
|
same as frequency1 |
Number of cycles per unit time. Entry 2. |
4 |
|
|
Linear |
Selects the kind for FreqBetweenModes3. |
5 |
|
|
10 |
Number of frequency entries. |
6 |
|
|
1.0 |
Controls the concentration of frequency samples between the range limits. |
Accepted words: Linear, Logarithmic.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the frequency set ID must be a positive integer.
Example record
FreqBetweenModes3;40;10.;1.E+3;Linear;5;2.
Reading the example gives id = 40, frequency1 = 10., frequency2 = 1.E+3, kind = Linear.
FreqLinearSteps1¶
Excitation frequencies at equal steps.
Record format and fields
FreqLinearSteps1;id;frequency1;frequencyIncrement;incrementCount
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
0.0 |
Number of cycles per unit time. Entry 1. |
3 |
|
|
Required |
Separation between adjacent frequencies (inverse time). |
4 |
|
|
1 |
Number of increment entries. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the frequency set ID must be a positive integer.
Example record
FreqLinearSteps1;2;50.;50.;9
Reading the example gives id = 2, frequency1 = 50., frequencyIncrement = 50., incrementCount = 9.
FreqList¶
A set of excitation frequencies listed one by one.
Record format and fields
FreqList;id;<frequencies>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
Repeated group frequencies. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Number of cycles per unit time. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the frequency set ID must be a positive integer.frequency1— the card needs at least one frequency.frequencies— a frequency must not be negative.
Example record
FreqList;40;5.;10.;20.;38.;40.;42.;80.;120.;250.
Reading the example gives id = 40.
FreqLogSteps2¶
Excitation frequencies at equal logarithmic steps.
Record format and fields
FreqLogSteps2;id;frequency1;frequency2;intervalCount
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Number of cycles per unit time. Entry 1. |
3 |
|
|
Required |
Number of cycles per unit time. Entry 2. |
4 |
|
|
1 |
Number of interval entries. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the frequency set ID must be a positive integer.
Example record
FreqLogSteps2;40;2.;400.;24
Reading the example gives id = 40, frequency1 = 2., frequency2 = 400., intervalCount = 24.
FreqModeFractions5¶
Fractions of the modal frequencies of a range (modal frequency response).
Record format and fields
FreqModeFractions5;id;frequency1;frequency2;<fractions>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
0.0 |
Number of cycles per unit time. Entry 1. |
3 |
|
|
1.0E20 |
Number of cycles per unit time. Entry 2. |
Repeated group fractions. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Portion of the corresponding total, expressed as a ratio. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the frequency set ID must be a positive integer.fraction1— the card needs at least one fraction.fractions— a fraction of a natural frequency must be greater than zero.
Example record
FreqModeFractions5;40;10.;1.E+3;0.8;0.9;1.;1.1;1.2
Reading the example gives id = 40, frequency1 = 10., frequency2 = 1.E+3.
FreqResponseLoad1¶
A frequency response excitation P(f) = A * (C(f) + i * D(f)) * exp(i * (phi - 2 * pi * f * tau)).
Record format and fields
FreqResponseLoad1;id;excitationId;delayId;delay;phaseId;phase;realTableId;realValue;imaginaryTableId;imaginaryValue;kind
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Identifier selecting the excitation record or set. |
3 |
|
|
— |
Identifier selecting the delay record or set. Alternative to |
4 |
|
|
0.0 |
Time shift relative to the reference excitation, in model time units. Alternative to |
5 |
|
|
— |
Identifier selecting the phase record or set. Alternative to |
6 |
|
|
0.0 |
Phase of the harmonic quantity relative to the reference oscillation. Alternative to |
7 |
|
|
— |
Table supplying the variation of real. Alternative to |
8 |
|
|
0.0 |
Real scalar value or real part of the complex quantity. Alternative to |
9 |
|
|
— |
Table supplying the variation of imaginary. Alternative to |
10 |
|
|
0.0 |
Imaginary part paired with the real component. Alternative to |
11 |
|
|
Load |
Selects the kind for FreqResponseLoad1. |
Accepted words: Acceleration, Displacement, Load, Velocity.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the dynamic load set ID must be a positive integer.
Example record
FreqResponseLoad1;3;4;;;;;5
Reading the example gives id = 3, excitationId = 4, realTableId = 5.
FreqResponseLoad2¶
A frequency response excitation P(f) = A * B(f) * exp(i * (phi(f) + phase - 2 * pi * f * tau)).
Record format and fields
FreqResponseLoad2;id;excitationId;delayId;delay;phaseId;phase;amplitudeTableId;amplitude;phaseTableId;phaseAngle;kind
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Identifier selecting the excitation record or set. |
3 |
|
|
— |
Identifier selecting the delay record or set. Alternative to |
4 |
|
|
0.0 |
Time shift relative to the reference excitation, in model time units. Alternative to |
5 |
|
|
— |
Identifier selecting the phase record or set. Alternative to |
6 |
|
|
0.0 |
Phase of the harmonic quantity relative to the reference oscillation. Alternative to |
7 |
|
|
— |
Table supplying the variation of amplitude. Alternative to |
8 |
|
|
— |
Size of the excitation or response before applying its phase. Alternative to |
9 |
|
|
— |
Table supplying the variation of phase. Alternative to |
10 |
|
|
0.0 |
Angular phase offset relative to the reference excitation. Alternative to |
11 |
|
|
Load |
Selects the kind for FreqResponseLoad2. |
Accepted words: Acceleration, Displacement, Load, Velocity.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the dynamic load set ID must be a positive integer.
Example record
FreqResponseLoad2;21;1;22;;23;;24;;25;;Load
Reading the example gives id = 21, excitationId = 1, delayId = 22, phaseId = 23.
FreqSpreadAroundModes4¶
A spread of frequencies around each modal frequency of a range (modal frequency response).
Record format and fields
FreqSpreadAroundModes4;id;frequency1;frequency2;frequencySpread;frequencyCount
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
0.0 |
Number of cycles per unit time. Entry 1. |
3 |
|
|
1.0E20 |
Number of cycles per unit time. Entry 2. |
4 |
|
|
0.10 |
The fractional spread on each side of a modal frequency. |
5 |
|
|
3 |
Number of frequency entries. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the frequency set ID must be a positive integer.
Example record
FreqSpreadAroundModes4;40;10.;1.E+3;0.1;3
Reading the example gives id = 40, frequency1 = 10., frequency2 = 1.E+3, frequencySpread = 0.1.
FrfAssemblyLoadDelay¶
The time delay of a dynamic load on one degree of freedom of an FRF component, in an FRF based assembly (FBA).
Record format and fields
FrfAssemblyLoadDelay;id;frfComponent;pointId;components;delay
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
— |
Identifier addressing frf component data. |
3 |
|
|
Required |
Identifier of the point to which this entry applies. |
4 |
|
|
0 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. |
5 |
|
|
Required |
Time shift relative to the reference excitation, in model time units. |
Accepted words: Constant, Element, Table.
Example record
FrfAssemblyLoadDelay;402;PLATE;15;3;5.E-4
Reading the example gives id = 402, frfComponent = PLATE, pointId = 15, components = 3.
FrfAssemblyLoadPhase¶
The phase lead of a dynamic load on one degree of freedom of an FRF component, in an FRF based assembly (FBA).
Record format and fields
FrfAssemblyLoadPhase;id;frfComponent;pointId;components;phase
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
— |
Identifier addressing frf component data. |
3 |
|
|
Required |
Identifier of the point to which this entry applies. |
4 |
|
|
0 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. |
5 |
|
|
Required |
Phase of the harmonic quantity relative to the reference oscillation. |
Accepted words: Constant, Element, Table.
Example record
FrfAssemblyLoadPhase;403;PLATE;15;3;20.
Reading the example gives id = 403, frfComponent = PLATE, pointId = 15, components = 3.
FrfAssemblyLoadScale¶
The scale factor of a dynamic load on one degree of freedom of an FRF component, in an FRF based assembly (FBA).
Record format and fields
FrfAssemblyLoadScale;id;frfComponent;pointId;components;scaleFactor
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
— |
Identifier addressing frf component data. |
3 |
|
|
Required |
Identifier of the point to which this entry applies. |
4 |
|
|
0 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. |
5 |
|
|
Required |
Multiplier applied to the quantity specified by the entry. |
Accepted words: Constant, Element, Table.
Example record
FrfAssemblyLoadScale;401;PLATE;15;3;1.
Reading the example gives id = 401, frfComponent = PLATE, pointId = 15, components = 3.
FrfComponent¶
A component whose frequency response functions were made by an earlier run and that an FRF based assembly (FBA) puts together with others.
Record format and fields
FrfComponent;id;componentName;medium;unitNumber;lengthScaleFactor;forceScaleFactor
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
— |
Text naming the component. |
3 |
|
|
— |
Storage medium supplying the component frequency response functions. |
4 |
|
|
0 |
Logical file unit used to identify an external resource. |
5 |
|
|
1.0 |
Multiplier for length scale. |
6 |
|
|
1.0 |
Multiplier for force scale. |
Accepted words: All, Assembly, BinaryResultsFile, Component, ConnectionInfo, Constant, Database, Element, Table, UniversalFile.
Example record
FrfComponent;10;PLATE;BinaryResultsFile;25
Reading the example gives id = 10, componentName = PLATE, medium = BinaryResultsFile, unitNumber = 25.
FrfConnection¶
An explicit connection between a point of one FRF component and a point of another, in an FRF based assembly (FBA).
Record format and fields
FrfConnection;id;frfComponent1;point1;frfComponent2;point2
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
— |
Frequency-response component on side 1 of the assembly connection. |
3 |
|
|
— |
Point at position 1 in the ordered FrfConnection data. |
4 |
|
|
— |
Frequency-response component on side 2 of the assembly connection. |
5 |
|
|
— |
Point at position 2 in the ordered FrfConnection data. |
Accepted words: Constant, Element, Table.
Example record
FrfConnection;1;PLATE;5;STRUT;201
Reading the example gives id = 1, frfComponent1 = PLATE, point1 = 5, frfComponent2 = STRUT.
FrfExcitationDof¶
A degree of freedom where a unit load generates a frequency-response function. pointId identifies a node or scalar point. components is 1 to 6 for a node, 0 or blank for a scalar point. entryLabel is a required literal text value, preserved whole regardless of its length.
Record format and fields
FrfExcitationDof;pointId;components;entryLabel
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier of the point to which this entry applies. |
2 |
|
|
0 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. |
3 |
|
|
— |
User label associated with the entry. Written as one text field. |
Accepted words: Constant, Element, Table.
Example record
FrfExcitationDof;13;3;UNIT LOAD AT GRID POINT 13 ALONG Z
Reading the example gives pointId = 13, components = 3, entryLabel = UNIT LOAD AT GRID POINT 13 ALONG Z.
FrfExcitationDofList¶
Degrees of freedom where unit loads are applied to generate frequency response functions, for a list of points that share their components.
Record format and fields
FrfExcitationDofList;components;<pointIds>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
0 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. |
Repeated group pointIds. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier of the point to which this entry applies. |
Accepted words: Through.
Example record
FrfExcitationDofList;1;202;212
Reading the example gives components = 1.
FrfFlexibleConnection¶
The stiffness, damping and structural damping of a flexible connection between a point of one FRF component and a point of another, in an FRF based assembly (FBA).
Record format and fields
FrfFlexibleConnection;id;components;frfComponent1;point1;frfComponent2;point2;stiffnessTableId;stiffness;dampingTableId;damping;structuralDampingTableId;structuralDamping
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
0 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. |
3 |
|
|
— |
Frequency-response component on side 1 of the assembly connection. |
4 |
|
|
— |
Point at position 1 in the ordered FrfFlexibleConnection data. |
5 |
|
|
— |
Frequency-response component on side 2 of the assembly connection. |
6 |
|
|
— |
Point at position 2 in the ordered FrfFlexibleConnection data. |
7 |
|
|
— |
Table supplying the variation of stiffness. Alternative to |
8 |
|
|
— |
Elastic restoring coefficient relating generalized force to the associated displacement. Alternative to |
9 |
|
|
— |
Table supplying the variation of damping. Alternative to |
10 |
|
|
— |
Dissipative coefficient of the selected connection, material or response law. Alternative to |
11 |
|
|
— |
Identifier of the table supplying the structural damping coefficient. Alternative to |
12 |
|
|
— |
Structural damping coefficient for the associated material or property. Alternative to |
Accepted words: Constant, Element, Table.
Example record
FrfFlexibleConnection;2;3;PLATE;5;STRUT;201;;1.E+3;;0.5;;0.02
Reading the example gives id = 2, components = 3, frfComponent1 = PLATE, point1 = 5.
FrfReleasedDofs¶
Degrees of freedom of the connection grid points of FRF components that an FRF based assembly (FBA) does not connect.
Record format and fields
FrfReleasedDofs;id;components;frfComponent1;node1;frfComponent2;node2;frfComponent3;node3
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. |
3 |
|
|
— |
Frequency-response component on side 1 of the assembly connection. |
4 |
|
|
— |
Grid point to which this entry applies. Entry 1. |
5 |
|
|
— |
Frequency-response component on side 2 of the assembly connection. |
6 |
|
|
— |
Grid point to which this entry applies. Entry 2. |
7 |
|
|
— |
Frequency-response component on side 3 of the assembly connection. |
8 |
|
|
— |
Grid point to which this entry applies. Entry 3. |
Accepted words: Constant, Element, NodePoint2, NodePoint3, Table.
Example record
FrfReleasedDofs;3;456;STRUT;211
Reading the example gives id = 3, components = 456, frfComponent1 = STRUT, node1 = 211.
FrfSinglePointConstr¶
Single-point constraints on connection points of FRF components in an FRF based assembly (FBA).
Record format and fields
FrfSinglePointConstr;id;components;frfComponent1;point1;frfComponent2;point2;frfComponent3;point3
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
0 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. |
3 |
|
|
— |
Frequency-response component on side 1 of the assembly connection. |
4 |
|
|
— |
Point at position 1 in the ordered FrfSinglePointConstr data. |
5 |
|
|
— |
Frequency-response component on side 2 of the assembly connection. |
6 |
|
|
— |
Point at position 2 in the ordered FrfSinglePointConstr data. |
7 |
|
|
— |
Frequency-response component on side 3 of the assembly connection. |
8 |
|
|
— |
Point at position 3 in the ordered FrfSinglePointConstr data. |
Accepted words: Constant, Element, Point3Kind, Table.
Example record
FrfSinglePointConstr;300;1;PLATE;15
Reading the example gives id = 300, components = 1, frfComponent1 = PLATE, point1 = 15.
HeatShellNodalLoad¶
Concentrated static loads, a power input, on the grid points of heat shell elements (those of a ShellPropNonlinear heat transfer property) with a linear or quadratic temperature distribution through the thickness.
Record format and fields
HeatShellNodalLoad;id;node1;components1;heatFlux1;node2;components2;heatFlux2
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
— |
Identifier addressing node data. |
3 |
|
|
1 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1. |
4 |
|
|
— |
Thermal energy crossing unit area per unit time. Entry 1. |
5 |
|
|
— |
Grid point to which this entry applies. Entry 2. |
6 |
|
|
1 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2. |
7 |
|
|
— |
Thermal energy crossing unit area per unit time. Entry 2. |
Accepted words: Constant, Element, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
node1— the card needs at least one load.node2— the card gives the loads on at most two grid points.
Example record
HeatShellNodalLoad;10;3;1;50.;6;2;50.
Reading the example gives id = 10, node1 = 3, components1 = 1, heatFlux1 = 50..
Referenced records in this example
Node via
node1 = 3.
HybridDamping¶
The hybrid modal damping of a direct dynamic solution.
Record format and fields
HybridDamping;id;methodId;modalDampingTableId;dampingInStiffness;printEigenvalues
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
Required |
Identifier selecting the method record or set. |
3 |
|
|
Required |
Table supplying the variation of modal damping. |
4 |
|
|
— |
Specifies inclusion of damping contributions in the stiffness representation. |
5 |
|
|
— |
Switch controlling the listing of the extracted roots. |
Accepted words: Constant, Element, No, Table, Yes.
Example record
HybridDamping;71;72;73;Yes
Reading the example gives id = 71, methodId = 72, modalDampingTableId = 73, dampingInStiffness = Yes.
HybridDampingRotorOptions¶
Selects structural, material and Rayleigh damping contributions for hybrid modal damping of a rotor.
Record format and fields
HybridDampingRotorOptions;id;structuralDamping;alphaCoefficient1;alphaCoefficient2;hybridDampingId;structuralDampingFactor;rotorSeparation;structuralDampingFrequency;materialDampingFrequency;hybridDampingFrequency
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
0.0 |
Structural damping coefficient for the associated material or property. |
3 |
|
|
0.0 |
Coefficient in the relation for alpha. |
4 |
|
|
0.0 |
Coefficient in the relation for alpha. |
5 |
|
|
0 |
Identifier selecting the hybrid damping record or set. |
6 |
|
|
1.0 |
Multiplier for structural damping. |
7 |
|
|
— |
Separation used in the rotor representation, in length units. |
8 |
|
|
0.0 |
Structural damping frequency (inverse time). |
9 |
|
|
0.0 |
Material damping frequency (inverse time). |
10 |
|
|
0.0 |
Hybrid damping frequency (inverse time). |
Accepted words: Constant, Element, No, Table, Yes.
Example record
HybridDampingRotorOptions;70;0.01;;;71
Reading the example gives id = 70, structuralDamping = 0.01, hybridDampingId = 71.
InitialElemValues¶
The initial values of element variables of the elements of an IdListSet1, at the start of the analysis.
Record format and fields
InitialElemValues;id;elementSetId;<variables>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Identifier selecting the element set record or set. |
Repeated group variables. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Text naming the variable. |
2 |
|
|
— |
Value of the independent or design variable at the selected evaluation point. |
Accepted words: ArtificialViscosity, CenterX, CenterY, CenterZ, Constant, Decay, Density, Divergence, Element, MaterialFraction, MomentumX, MomentumY, MomentumZ, RadialVelocity, SpecificInternalEnergy, Table, TableDynamic1, VelocityX, VelocityY, VelocityZ, VoidFraction.
Example record
InitialElemValues;81;5;Density;1.2E-11;SpecificInternalEnergy;2.08E+11
Reading the example gives id = 81, elementSetId = 5.
InitialValuesUserRoutine¶
Initial values of element or grid point variables that a user written subroutine computes.
Record format and fields
InitialValuesUserRoutine;id;group;routineName;elementSetId;target
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
— |
Grouping key for entries treated together. |
3 |
|
|
— |
Text naming the routine. |
4 |
|
|
Required |
Identifier selecting the element set record or set. |
5 |
|
|
— |
Requested target of the selected search or output operation. |
Accepted words: Constant, Element, ExternalInitialValues, Node, Table.
Example record
InitialValuesUserRoutine;30;initex;ExternalInitialValues;31;Node
Reading the example gives id = 30, group = initex, routineName = ExternalInitialValues, elementSetId = 31.
InitialVelocityField¶
An initial velocity field of grid points made of a translation and a rotation about a grid point.
Record format and fields
InitialVelocityField;id;node;scaleFactor;xVelocity;yVelocity;zVelocity;xRotation;yRotation;zRotation;<initializedNodes>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Grid point to which this entry applies. |
3 |
|
|
1.0 |
Multiplier applied to the quantity specified by the entry. |
4 |
|
|
0.0 |
X velocity (length per time). |
5 |
|
|
0.0 |
Y velocity (length per time). |
6 |
|
|
0.0 |
Z velocity (length per time). |
7 |
|
|
0.0 |
The rotation velocity about G. |
8 |
|
|
0.0 |
Rotation about the y axis of the specified reference frame. |
9 |
|
|
0.0 |
Rotation about the z axis of the specified reference frame. |
Repeated group initializedNodes. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Grid point whose dynamic initial state is being assigned. |
Accepted words: By, Constant, Element, Table, Through.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
node1— the card needs the grid points to initialize.
Example record
InitialVelocityField;81;1;1.;1.E+4;0.;0.;0.;0.;0.;1;Through;8
Reading the example gives id = 81, node = 1, scaleFactor = 1., xVelocity = 1.E+4.
LanczosEigenMethod¶
Real eigenvalue extraction by the Lanczos method.
Record format and fields
LanczosEigenMethod;id;lowerFrequency;upperFrequency;desiredModeCount;messageLevel;maximumSet;shiftScale;norm;<options>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the method namespace. |
2 |
|
|
— |
Lower frequency (inverse time). |
3 |
|
|
— |
Upper frequency (inverse time). |
4 |
|
|
0 |
Number of desired mode entries. |
5 |
|
|
0 |
Diagnostic level. |
6 |
|
|
0 |
Maximum Lanczos block size. A blank field leaves the block size to the implementation. |
7 |
|
|
— |
Multiplier applied to the eigenvalue search shift. |
8 |
|
|
— |
Norm used for scaling a mode shape. |
Repeated group options. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Selects how the current entry or group is interpreted. |
Accepted words: Mass, Maximum.
Accepted parameter names: Alpha, DesiredModeCount, FrequencySegmentCount, LowerFrequency, MaximumSet, MessageLevel, Normalization, SegmentFrequency1, SegmentFrequency10, SegmentFrequency11, SegmentFrequency12, SegmentFrequency13, SegmentFrequency14, SegmentFrequency15, SegmentFrequency2, SegmentFrequency3, SegmentFrequency4, SegmentFrequency5, SegmentFrequency6, SegmentFrequency7, SegmentFrequency8, SegmentFrequency9, ShiftScale, UpperFrequency.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the method ID must be a positive integer.
Example record
LanczosEigenMethod;1;;3.E+3;4
Reading the example gives id = 1, upperFrequency = 3.E+3, desiredModeCount = 4.
NonlinearNegativePowerLoad4¶
A nonlinear load that is a negative variable raised to a power.
Record format and fields
NonlinearNegativePowerLoad4;id;nodeI;componentsI;scaleFactor;nodeJ;componentsJ;exponent
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Identifier addressing scalar or grid point data. |
3 |
|
|
0 |
Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6. |
4 |
|
|
Required |
Multiplier applied to the quantity specified by the entry. |
5 |
|
|
Required |
Identifier addressing scalar or grid point data. |
6 |
|
|
0 |
Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6. |
7 |
|
|
Required |
Power applied to the associated variable in the stated relation. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the nonlinear load set ID must be a positive integer.nodeI— the point ID must be a positive integer.nodeJ— the point ID must be a positive integer.
Example record
NonlinearNegativePowerLoad4;70;5;3;-0.5;5;3;3.
Reading the example gives id = 70, nodeI = 5, componentsI = 3, scaleFactor = -0.5.
NonlinearPositivePowerLoad3¶
A nonlinear load that is a positive variable raised to a power.
Record format and fields
NonlinearPositivePowerLoad3;id;nodeI;componentsI;scaleFactor;nodeJ;componentsJ;exponent
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Identifier addressing scalar or grid point data. |
3 |
|
|
0 |
Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6. |
4 |
|
|
Required |
Multiplier applied to the quantity specified by the entry. |
5 |
|
|
Required |
Identifier addressing scalar or grid point data. |
6 |
|
|
0 |
Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6. |
7 |
|
|
Required |
Power applied to the associated variable in the stated relation. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the nonlinear load set ID must be a positive integer.nodeI— the point ID must be a positive integer.nodeJ— the point ID must be a positive integer.
Example record
NonlinearPositivePowerLoad3;70;5;3;-0.5;5;3;3.
Reading the example gives id = 70, nodeI = 5, componentsI = 3, scaleFactor = -0.5.
NonlinearProductLoad2¶
A nonlinear load that is the product of two variables.
Record format and fields
NonlinearProductLoad2;id;nodeI;componentsI;scaleFactor;nodeJ;componentsJ;nodeK;componentsK
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Identifier addressing scalar or grid point data. |
3 |
|
|
0 |
Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6. |
4 |
|
|
Required |
Multiplier applied to the quantity specified by the entry. |
5 |
|
|
Required |
Identifier addressing scalar or grid point data. |
6 |
|
|
0 |
Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6. |
7 |
|
|
Required |
Identifier addressing scalar or grid point data. |
8 |
|
|
0 |
Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the nonlinear load set ID must be a positive integer.nodeI— the point ID must be a positive integer.nodeJ— the point ID must be a positive integer.nodeK— the point ID must be a positive integer.
Example record
NonlinearProductLoad2;70;10;3;-0.001;10;13;10;3
Reading the example gives id = 70, nodeI = 10, componentsI = 3, scaleFactor = -0.001.
NonlinearTableLoad1¶
A nonlinear load that is a tabular function of a displacement or a velocity.
Record format and fields
NonlinearTableLoad1;id;nodeI;componentsI;scaleFactor;nodeJ;componentsJ;tableId
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Identifier addressing scalar or grid point data. |
3 |
|
|
0 |
Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6. |
4 |
|
|
Required |
Multiplier applied to the quantity specified by the entry. |
5 |
|
|
Required |
Identifier addressing scalar or grid point data. |
6 |
|
|
0 |
Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6. |
7 |
|
|
Required |
Identifier of the tabulated function to evaluate. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the nonlinear load set ID must be a positive integer.nodeI— the point ID must be a positive integer.nodeJ— the point ID must be a positive integer.tableId— the table ID must be a positive integer.
Example record
NonlinearTableLoad1;70;15;3;1.;15;3;73
Reading the example gives id = 70, nodeI = 15, componentsI = 3, scaleFactor = 1..
Referenced records in this example
TableDynamic2 via
tableId = 73.
RandomSpectralDensity¶
A power spectral density factor of a random analysis.
Record format and fields
RandomSpectralDensity;id;subcaseJ;subcaseK;realPart;imaginaryPart;tableId
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
The subcase of the excited load set. |
3 |
|
|
Required |
The subcase of the applied load set (K >= J). |
4 |
|
|
0.0 |
In-phase component of the complex quantity. |
5 |
|
|
0.0 |
Quadrature component of the complex quantity. |
6 |
|
|
0 |
Identifier of the tabulated function to evaluate. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the random analysis set ID must be a positive integer.
Example record
RandomSpectralDensity;90;1;1;1.;0.;91
Reading the example gives id = 90, subcaseJ = 1, subcaseK = 1, realPart = 1..
Referenced records in this example
TableRandomSpectrum1 via
tableId = 91.
RandomTimeLags¶
The time lags of the autocorrelation function of a random analysis.
Record format and fields
RandomTimeLags;id;count;startTime;maximumTime
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Number of entries to process in this group. |
3 |
|
|
Required |
Start time (time). |
4 |
|
|
Required |
Maximum time (time). |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the random analysis set ID must be a positive integer.
Example record
RandomTimeLags;90;10;0.001;0.05
Reading the example gives id = 90, count = 10, startTime = 0.001, maximumTime = 0.05.
RealEigenMethod¶
Real eigenvalue extraction, with the method named on the card.
Record format and fields
RealEigenMethod;id;method;frequency1;frequency2;estimatedModeCount;desiredModeCount;normalization;normNode;normComponent
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the method namespace. |
2 |
|
|
Lanczos |
Selects the method for RealEigenMethod. |
3 |
|
|
— |
Number of cycles per unit time. Entry 1. |
4 |
|
|
— |
Number of cycles per unit time. Entry 2. |
5 |
|
|
0 |
Number of estimated mode entries. |
6 |
|
|
— |
Number of desired mode entries. |
7 |
|
|
Mass |
Rule used to scale the amplitude of an eigenvector. |
8 |
|
|
0 |
Identifier addressing node data. |
9 |
|
|
0 |
Degree of freedom used as the normalization reference. |
Accepted words: AutomaticGivens, AutomaticHouseholder, Givens, Householder, InverseIteration, Lanczos, Mass, Maximum, ModifiedGivens, ModifiedHouseholder, Point, SturmInverse.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the method ID must be a positive integer.
Example record
RealEigenMethod;71;Lanczos;;;;8;Mass
Reading the example gives id = 71, method = Lanczos, desiredModeCount = 8, normalization = Mass.
RotorHybridDamping¶
Associates individual rotors with their hybrid modal damping definitions.
Record format and fields
RotorHybridDamping;<pairs>
This part of the record has no fixed fields.
Repeated group pairs. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier selecting the rotor record or set. |
2 |
|
|
— |
Identifier selecting the hybrid damping record or set. |
Accepted words: Constant, Element, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
rotorId1— the card needs at least one pair of a rotor and a hybrid damping.
Example record
RotorHybridDamping;10;11
RotorUnbalanceLoad¶
A rotating unbalance load of a rotordynamic transient or frequency response analysis.
Record format and fields
RotorUnbalanceLoad;id;massTableId;mass;nodeId;directionX;directionY;directionZ;radialOffsetTableId;radialOffset;angularPosition;axialOffsetTableId;axialOffset;startTimeOrFrequency;stopTimeOrFrequency;correctionFlag;forcePointT1;forcePointT2;forcePointT3;forcePointR1;forcePointR2;forcePointR3;massCorrectionPointT1;massCorrectionPointT2;massCorrectionPointT3;massCorrectionPointR1;massCorrectionPointR2;massCorrectionPointR3;speedCorrectionPoint1;speedCorrectionPoint2;speedCorrectionPoint3
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
— |
Table supplying the variation of mass. Alternative to |
3 |
|
|
— |
Inertial mass associated with the selected component or body. Alternative to |
4 |
|
|
Required |
Identifier of the grid point addressed by this record. |
5 |
|
|
Required |
X component of the specified direction vector in its reference frame. |
6 |
|
|
Required |
Y component of the specified direction vector in its reference frame. |
7 |
|
|
Required |
Z component of the specified direction vector in its reference frame. |
8 |
|
|
— |
Table supplying the variation of radial offset. Alternative to |
9 |
|
|
1.0 |
Distance from the reference axis in the radial direction. Alternative to |
10 |
|
|
0.0 |
The angular position of the mass, in degrees. |
11 |
|
|
— |
Table supplying the variation of axial offset. Alternative to |
12 |
|
|
0.0 |
Distance from the reference position measured along the rotation axis. Alternative to |
13 |
|
|
0.0 |
Start time or frequency (inverse time). |
14 |
|
|
999999.0 |
Stop time or frequency (inverse time). |
15 |
|
|
None |
Selects the correction flag for RotorUnbalanceLoad. |
16 |
|
|
0 |
Extra point for unbalance force output, component 1 of the T group (T for translations, R for rotations). |
17 |
|
|
0 |
Extra point for unbalance force output, component 2 of the T group (T for translations, R for rotations). |
18 |
|
|
0 |
Extra point for unbalance force output, component 3 of the T group (T for translations, R for rotations). |
19 |
|
|
0 |
Extra point for unbalance force output, component 1 of the R group (T for translations, R for rotations). |
20 |
|
|
0 |
Extra point for unbalance force output, component 2 of the R group (T for translations, R for rotations). |
21 |
|
|
0 |
Extra point for unbalance force output, component 3 of the R group (T for translations, R for rotations). |
22 |
|
|
0 |
Extra point for the mass correction, component 1 of the T group (T for translations, R for rotations). |
23 |
|
|
0 |
Extra point for the mass correction, component 2 of the T group (T for translations, R for rotations). |
24 |
|
|
0 |
Extra point for the mass correction, component 3 of the T group (T for translations, R for rotations). |
25 |
|
|
0 |
Extra point for the mass correction, component 1 of the R group (T for translations, R for rotations). |
26 |
|
|
0 |
Extra point for the mass correction, component 2 of the R group (T for translations, R for rotations). |
27 |
|
|
0 |
Extra point for the mass correction, component 3 of the R group (T for translations, R for rotations). |
28 |
|
|
0 |
Extra point for spin-rate correction component 1. |
29 |
|
|
0 |
Extra point for spin-rate correction component 2. |
30 |
|
|
0 |
Extra point for spin-rate correction component 3. |
Accepted words: Acceleration, Both, Displacement, Load, Mass, None, Speed, Velocity.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the set ID must be a positive integer.
Example record
RotorUnbalanceLoad;300;;1.E-5;1003;0.;1.;0.;;10.;0.;;0.
Reading the example gives id = 300, mass = 1.E-5, nodeId = 1003, directionX = 0..
TransferFunction¶
Relates a dependent degree of freedom to independent inputs using coefficients of the value and its first two time derivatives.
Record format and fields
TransferFunction;id;nodeD;componentsD;coefficientB0;coefficientB1;coefficientB2;<terms>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Identifier addressing scalar or grid point data. |
3 |
|
|
0 |
Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6. |
4 |
|
|
0.0 |
Coefficient B0 in the TransferFunction relation. |
5 |
|
|
0.0 |
Coefficient B1 in the TransferFunction relation. |
6 |
|
|
0.0 |
Coefficient B2 in the TransferFunction relation. |
Repeated group terms. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Point identifier for the associated term. |
2 |
|
|
— |
Degrees of freedom involved in the associated term. |
3 |
|
|
— |
Coefficient A0 in the TransferFunction relation for terms. |
4 |
|
|
— |
Coefficient A1 in the TransferFunction relation for terms. |
5 |
|
|
— |
Coefficient A2 in the TransferFunction relation for terms. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the set ID must be a positive integer.
Example record
TransferFunction;60;901;;1.;;;15;3;-1.
Reading the example gives id = 60, nodeD = 901, coefficientB0 = 1..
TransientFormulaLoad2¶
A transient excitation given by a formula, for T1 <= t <= T2 and zero elsewhere: P(t) = A * t’^B * exp(C * t’) * cos(2 * pi * F * t’ + P), with t’ = t - T1 - tau.
Record format and fields
TransientFormulaLoad2;id;excitationId;delayId;delay;kind;time1;time2;frequency;phase;coefficientC;exponentB;initialDisplacementFactor;initialVelocityFactor
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Identifier selecting the excitation record or set. |
3 |
|
|
— |
Identifier selecting the delay record or set. Alternative to |
4 |
|
|
0.0 |
Time shift relative to the reference excitation, in model time units. Alternative to |
5 |
|
|
Load |
Selects the kind for TransientFormulaLoad2. |
6 |
|
|
0.0 |
Time 1 (time). |
7 |
|
|
same as time1 |
Time 2 (time). |
8 |
|
|
0.0 |
Number of cycles per unit time. |
9 |
|
|
0.0 |
Phase of the harmonic quantity relative to the reference oscillation. |
10 |
|
|
0.0 |
Coefficient C in the TransientFormulaLoad2 relation. |
11 |
|
|
0.0 |
The growth coefficient. |
12 |
|
|
0.0 |
Multiplier for initial displacement. |
13 |
|
|
0.0 |
Multiplier for initial velocity. |
Accepted words: Acceleration, Displacement, Load, Velocity.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the dynamic load set ID must be a positive integer.
Example record
TransientFormulaLoad2;51;2;;;Load;0.;0.05;0.;0.
Reading the example gives id = 51, excitationId = 2, kind = Load, time1 = 0..
TransientInitialCondition¶
The initial displacement and velocity of one degree of freedom of a transient analysis.
Record format and fields
TransientInitialCondition;id;node;components;initialDisplacement;initialVelocity
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Grid point to which this entry applies. |
3 |
|
|
0 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. |
4 |
|
|
0.0 |
The initial displacement. |
5 |
|
|
0.0 |
Initial velocity (length per time). |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the set ID must be a positive integer.
Example record
TransientInitialCondition;81;15;3;0.;50.
Reading the example gives id = 81, node = 15, components = 3, initialDisplacement = 0..
TransientTableLoad1¶
A transient excitation P(t) = A * F(t - tau), where F is a table.
Record format and fields
TransientTableLoad1;id;excitationId;delayId;delay;kind;tableId;functionValue;initialDisplacementFactor;initialVelocityFactor
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
Required |
Identifier selecting the excitation record or set. |
3 |
|
|
— |
Identifier selecting the delay record or set. Alternative to |
4 |
|
|
0.0 |
Time shift relative to the reference excitation, in model time units. Alternative to |
5 |
|
|
Load |
Selects the kind for TransientTableLoad1. |
6 |
|
|
— |
Identifier of the tabulated function to evaluate. Alternative to |
7 |
|
|
0.0 |
Value of the tabulated function at this sample. Alternative to |
8 |
|
|
0.0 |
Multiplier for initial displacement. |
9 |
|
|
0.0 |
Multiplier for initial velocity. |
Accepted words: Acceleration, Displacement, Load, Velocity.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the dynamic load set ID must be a positive integer.
Example record
TransientTableLoad1;1;2;;;0;3