Dynamics

All card families and alphabetical index

Read field positions from left to right within each table. A dash means the layout supplies no fixed default. Use a consistent system of units for dimensional quantities.

AcousticSourceLoad

An acoustic source given as power against frequency.

Record format and fields

AcousticSourceLoad;id;excitationId;delayId;delay;phaseId;phase;powerTableId;power;density;bulkModulus

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

excitationId

integer

Required

Identifier addressing excitation set data.

3

delayId

integer

—

Identifier selecting the delay record or set. Alternative to delay.

4

delay

real

0.0

Time shift relative to the reference excitation, in model time units. Alternative to delayId.

5

phaseId

integer

—

Identifier selecting the phase record or set. Alternative to phase.

6

phase

real

0.0

Phase of the harmonic quantity relative to the reference oscillation. Alternative to phaseId.

7

powerTableId

integer

—

Table supplying the variation of power. Alternative to power.

8

power

real

—

Exponent applied to the dependent relation. Alternative to powerTableId.

9

density

real

Required

Mass per unit volume for a volumetric material or fluid density.

10

bulkModulus

real

Required

Resistance to volumetric compression, expressed as pressure.

Accepted words: Acceleration, Displacement, Load, Velocity.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the dynamic load set ID must be a positive integer.

Example record

AcousticSourceLoad;30;31;;2.E-4;;10.;34;;1.2E-12;0.142

Model containing this record

Reading the example gives id = 30, excitationId = 31, delay = 2.E-4, phase = 10..

BucklingEigenMethod

Specifies the extraction data for a buckling eigenvalue problem.

Record format and fields

BucklingEigenMethod;id;method;lowerEigenvalue;upperEigenvalue;estimatedModeCount;desiredPositiveModeCount;desiredNegativeModeCount;norm;normNode;normComponent

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the method namespace.

2

method

text

—

Selects the method for BucklingEigenMethod.

3

lowerEigenvalue

real

Required

Lower bound of the eigenvalue interval to search.

4

upperEigenvalue

real

Required

Upper bound of the eigenvalue interval to search.

5

estimatedModeCount

integer

0

Number of estimated mode entries.

6

desiredPositiveModeCount

integer

—

Number of desired positive mode entries.

7

desiredNegativeModeCount

integer

—

Number of desired negative mode entries.

8

norm

text

—

Norm used for scaling a mode shape.

9

normNode

integer

0

Identifier addressing scalar or grid point data.

10

normComponent

integer

0

Degree of freedom used as the normalization reference.

Accepted words: InverseIteration, Maximum, Point, SturmInverse.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the method ID must be a positive integer.

Example record

BucklingEigenMethod;30;SturmInverse;0.;50.;;2;;Maximum

Model containing this record

Reading the example gives id = 30, method = SturmInverse, lowerEigenvalue = 0., upperEigenvalue = 50..

ComplexEigenMethod

The data of a complex eigenvalue extraction.

Record format and fields

ComplexEigenMethod;id;methodName;norm;normNode;normComponent;convergenceTolerance;desiredModeCount0;<regions>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

methodName

text

—

Text naming the method.

3

norm

text

Maximum

Norm used for scaling a mode shape.

4

normNode

integer

0

Identifier addressing scalar or grid point data.

5

normComponent

integer

0

Degree of freedom used as the normalization reference.

6

convergenceTolerance

real

—

Permitted numerical deviation for convergence.

7

desiredModeCount0

integer

0

Number of desired mode entries.

Repeated group regions. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

alphaA

real

—

The real part of the region’s first end point, or of the shift point.

2

omegaA

real

—

The imaginary part.

3

alphaB

real

—

The second end point (region form).

4

omegaB

real

—

Angular-frequency term associated with the second frequency parameter of the relation.

5

regionWidth

real

—

Region width (length).

6

estimatedModeCount

integer

—

Number of estimated mode entries.

7

desiredModeCount

integer

—

Number of desired mode entries.

Accepted words: ComplexLanczos, DeterminantMethod, HessenbergMethod, ImplicitRestartedArnoldi, InverseIteration, Maximum, Point.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the method ID must be a positive integer.

  • alphaA — the coordinates of a search region must be finite numbers.

Example record

ComplexEigenMethod;40;InverseIteration;Maximum;;;;;0.;0.;0.;3.E+3;500.;4;4

Model containing this record

Reading the example gives id = 40, methodName = InverseIteration, norm = Maximum.

ComplexEigenPoles

Supplies one or two poles for the determinant-based complex eigenvalue method.

Record format and fields

ComplexEigenPoles;id;realPart1;imaginaryPart1;multiplicity1;realPart2;imaginaryPart2;multiplicity2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

realPart1

real

Required

In-phase component of the complex quantity. Entry 1.

3

imaginaryPart1

real

Required

Quadrature component of the complex quantity. Entry 1.

4

multiplicity1

integer

Required

Number of times the corresponding root or contribution is represented. Entry 1.

5

realPart2

real

Required

In-phase component of the complex quantity. Entry 2.

6

imaginaryPart2

real

Required

Quadrature component of the complex quantity. Entry 2.

7

multiplicity2

integer

Required

Number of times the corresponding root or contribution is represented. Entry 2.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the set ID must be a positive integer.

  • realPart1 — the coordinates of a pole must be finite numbers.

  • realPart2 — the coordinates of a pole must be finite numbers.

Example record

ComplexEigenPoles;40;-10.;0.;1;-10.;500.;1

Model containing this record

Reading the example gives id = 40, realPart1 = -10., imaginaryPart1 = 0., multiplicity1 = 1.

DynamicLoadCombination

A dynamic load made of other dynamic load sets, combined linearly.

Record format and fields

DynamicLoadCombination;id;scaleFactor;<terms>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

scaleFactor

real

Required

Multiplier applied to the quantity specified by the entry.

Repeated group terms. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

termScaleFactor

real

—

Multiplier for term scale.

2

loadSetId

integer

—

Identifier selecting the load set record or set.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the dynamic load set ID must be a positive integer.

  • scaleFactor1 — the card needs at least one dynamic load set.

  • loadSetId1 — a dynamic load set ID must be a positive integer.

  • loadSetId1 — the card cannot refer to its own set ID.

Example record

DynamicLoadCombination;1;1.;1.;31;1.;32

Model containing this record

Reading the example gives id = 1, scaleFactor = 1..

DynamicLoadDelay

Time delays of a dynamic load on one or two degrees of freedom.

Record format and fields

DynamicLoadDelay;id;point1;components1;delay1;point2;components2;delay2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

point1

integer

Required

Identifier addressing node data.

3

components1

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1.

4

delay1

real

Required

Time shift relative to the reference excitation, in model time units. Entry 1.

5

point2

integer

Required

Identifier addressing node data.

6

components2

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2.

7

delay2

real

Required

Time shift relative to the reference excitation, in model time units. Entry 2.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the set ID must be a positive integer.

  • point1 — the point ID must be a positive integer.

  • point2 — the point ID must be a positive integer.

Example record

DynamicLoadDelay;22;15;3;5.E-4

Model containing this record

Reading the example gives id = 22, point1 = 15, components1 = 3, delay1 = 5.E-4.

DynamicLoadPhase

Phase leads of a dynamic load on one or two degrees of freedom.

Record format and fields

DynamicLoadPhase;id;point1;components1;phaseAngle1;point2;components2;phaseAngle2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

point1

integer

Required

Identifier addressing node data.

3

components1

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1.

4

phaseAngle1

real

Required

Angular phase offset relative to the reference excitation. Entry 1.

5

point2

integer

Required

Identifier addressing node data.

6

components2

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2.

7

phaseAngle2

real

Required

Angular phase offset relative to the reference excitation. Entry 2.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the set ID must be a positive integer.

  • point1 — the point ID must be a positive integer.

  • point2 — the point ID must be a positive integer.

Example record

DynamicLoadPhase;23;15;3;30.

Model containing this record

Reading the example gives id = 23, point1 = 15, components1 = 3, phaseAngle1 = 30..

DynamicLoadScale

Scale (area) factors of a load on one or two degrees of freedom.

Record format and fields

DynamicLoadScale;id;point1;components1;scaleFactor1;point2;components2;scaleFactor2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

point1

integer

Required

Identifier addressing node data.

3

components1

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1.

4

scaleFactor1

real

Required

Multiplier applied to the quantity specified by the entry. Entry 1.

5

point2

integer

Required

Identifier addressing node data.

6

components2

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2.

7

scaleFactor2

real

Required

Multiplier applied to the quantity specified by the entry. Entry 2.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the set ID must be a positive integer.

  • point1 — the point ID must be a positive integer.

  • point2 — the point ID must be a positive integer.

Example record

DynamicLoadScale;41;102;1;1.;213;3;1.

Model containing this record

Reading the example gives id = 41, point1 = 102, components1 = 1, scaleFactor1 = 1..

Referenced records in this example

  • Node via point1 = 102, point2 = 213.

FreqBetweenModes3

Excitation frequencies between the modal frequencies of a range (modal frequency response).

Record format and fields

FreqBetweenModes3;id;frequency1;frequency2;kind;frequencyCount;clustering

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

frequency1

real

Required

Number of cycles per unit time. Entry 1.

3

frequency2

real

same as frequency1

Number of cycles per unit time. Entry 2.

4

kind

text

Linear

Selects the kind for FreqBetweenModes3.

5

frequencyCount

integer

10

Number of frequency entries.

6

clustering

real

1.0

Controls the concentration of frequency samples between the range limits.

Accepted words: Linear, Logarithmic.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the frequency set ID must be a positive integer.

Example record

FreqBetweenModes3;40;10.;1.E+3;Linear;5;2.

Model containing this record

Reading the example gives id = 40, frequency1 = 10., frequency2 = 1.E+3, kind = Linear.

FreqLinearSteps1

Excitation frequencies at equal steps.

Record format and fields

FreqLinearSteps1;id;frequency1;frequencyIncrement;incrementCount

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

frequency1

real

0.0

Number of cycles per unit time. Entry 1.

3

frequencyIncrement

real

Required

Separation between adjacent frequencies (inverse time).

4

incrementCount

integer

1

Number of increment entries.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the frequency set ID must be a positive integer.

Example record

FreqLinearSteps1;2;50.;50.;9

Model containing this record

Reading the example gives id = 2, frequency1 = 50., frequencyIncrement = 50., incrementCount = 9.

FreqList

A set of excitation frequencies listed one by one.

Record format and fields

FreqList;id;<frequencies>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

Repeated group frequencies. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

frequency

real

—

Number of cycles per unit time.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the frequency set ID must be a positive integer.

  • frequency1 — the card needs at least one frequency.

  • frequencies — a frequency must not be negative.

Example record

FreqList;40;5.;10.;20.;38.;40.;42.;80.;120.;250.

Model containing this record

Reading the example gives id = 40.

FreqLogSteps2

Excitation frequencies at equal logarithmic steps.

Record format and fields

FreqLogSteps2;id;frequency1;frequency2;intervalCount

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

frequency1

real

Required

Number of cycles per unit time. Entry 1.

3

frequency2

real

Required

Number of cycles per unit time. Entry 2.

4

intervalCount

integer

1

Number of interval entries.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the frequency set ID must be a positive integer.

Example record

FreqLogSteps2;40;2.;400.;24

Model containing this record

Reading the example gives id = 40, frequency1 = 2., frequency2 = 400., intervalCount = 24.

FreqModeFractions5

Fractions of the modal frequencies of a range (modal frequency response).

Record format and fields

FreqModeFractions5;id;frequency1;frequency2;<fractions>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

frequency1

real

0.0

Number of cycles per unit time. Entry 1.

3

frequency2

real

1.0E20

Number of cycles per unit time. Entry 2.

Repeated group fractions. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

fraction

real

—

Portion of the corresponding total, expressed as a ratio.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the frequency set ID must be a positive integer.

  • fraction1 — the card needs at least one fraction.

  • fractions — a fraction of a natural frequency must be greater than zero.

Example record

FreqModeFractions5;40;10.;1.E+3;0.8;0.9;1.;1.1;1.2

Model containing this record

Reading the example gives id = 40, frequency1 = 10., frequency2 = 1.E+3.

FreqResponseLoad1

A frequency response excitation P(f) = A * (C(f) + i * D(f)) * exp(i * (phi - 2 * pi * f * tau)).

Record format and fields

FreqResponseLoad1;id;excitationId;delayId;delay;phaseId;phase;realTableId;realValue;imaginaryTableId;imaginaryValue;kind

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

excitationId

integer

Required

Identifier selecting the excitation record or set.

3

delayId

integer

—

Identifier selecting the delay record or set. Alternative to delay.

4

delay

real

0.0

Time shift relative to the reference excitation, in model time units. Alternative to delayId.

5

phaseId

integer

—

Identifier selecting the phase record or set. Alternative to phase.

6

phase

real

0.0

Phase of the harmonic quantity relative to the reference oscillation. Alternative to phaseId.

7

realTableId

integer

—

Table supplying the variation of real. Alternative to realValue.

8

realValue

real

0.0

Real scalar value or real part of the complex quantity. Alternative to realTableId.

9

imaginaryTableId

integer

—

Table supplying the variation of imaginary. Alternative to imaginaryValue.

10

imaginaryValue

real

0.0

Imaginary part paired with the real component. Alternative to imaginaryTableId.

11

kind

any

Load

Selects the kind for FreqResponseLoad1.

Accepted words: Acceleration, Displacement, Load, Velocity.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the dynamic load set ID must be a positive integer.

Example record

FreqResponseLoad1;3;4;;;;;5

Model containing this record

Reading the example gives id = 3, excitationId = 4, realTableId = 5.

FreqResponseLoad2

A frequency response excitation P(f) = A * B(f) * exp(i * (phi(f) + phase - 2 * pi * f * tau)).

Record format and fields

FreqResponseLoad2;id;excitationId;delayId;delay;phaseId;phase;amplitudeTableId;amplitude;phaseTableId;phaseAngle;kind

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

excitationId

integer

Required

Identifier selecting the excitation record or set.

3

delayId

integer

—

Identifier selecting the delay record or set. Alternative to delay.

4

delay

real

0.0

Time shift relative to the reference excitation, in model time units. Alternative to delayId.

5

phaseId

integer

—

Identifier selecting the phase record or set. Alternative to phase.

6

phase

real

0.0

Phase of the harmonic quantity relative to the reference oscillation. Alternative to phaseId.

7

amplitudeTableId

integer

—

Table supplying the variation of amplitude. Alternative to amplitude.

8

amplitude

real

—

Size of the excitation or response before applying its phase. Alternative to amplitudeTableId.

9

phaseTableId

integer

—

Table supplying the variation of phase. Alternative to phaseAngle.

10

phaseAngle

real

0.0

Angular phase offset relative to the reference excitation. Alternative to phaseTableId.

11

kind

any

Load

Selects the kind for FreqResponseLoad2.

Accepted words: Acceleration, Displacement, Load, Velocity.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the dynamic load set ID must be a positive integer.

Example record

FreqResponseLoad2;21;1;22;;23;;24;;25;;Load

Model containing this record

Reading the example gives id = 21, excitationId = 1, delayId = 22, phaseId = 23.

FreqSpreadAroundModes4

A spread of frequencies around each modal frequency of a range (modal frequency response).

Record format and fields

FreqSpreadAroundModes4;id;frequency1;frequency2;frequencySpread;frequencyCount

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

frequency1

real

0.0

Number of cycles per unit time. Entry 1.

3

frequency2

real

1.0E20

Number of cycles per unit time. Entry 2.

4

frequencySpread

real

0.10

The fractional spread on each side of a modal frequency.

5

frequencyCount

integer

3

Number of frequency entries.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the frequency set ID must be a positive integer.

Example record

FreqSpreadAroundModes4;40;10.;1.E+3;0.1;3

Model containing this record

Reading the example gives id = 40, frequency1 = 10., frequency2 = 1.E+3, frequencySpread = 0.1.

FrfAssemblyLoadDelay

The time delay of a dynamic load on one degree of freedom of an FRF component, in an FRF based assembly (FBA).

Record format and fields

FrfAssemblyLoadDelay;id;frfComponent;pointId;components;delay

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

frfComponent

any

—

Identifier addressing frf component data.

3

pointId

integer

Required

Identifier of the point to which this entry applies.

4

components

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations.

5

delay

real

Required

Time shift relative to the reference excitation, in model time units.

Accepted words: Constant, Element, Table.

Example record

FrfAssemblyLoadDelay;402;PLATE;15;3;5.E-4

Model containing this record

Reading the example gives id = 402, frfComponent = PLATE, pointId = 15, components = 3.

FrfAssemblyLoadPhase

The phase lead of a dynamic load on one degree of freedom of an FRF component, in an FRF based assembly (FBA).

Record format and fields

FrfAssemblyLoadPhase;id;frfComponent;pointId;components;phase

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

frfComponent

any

—

Identifier addressing frf component data.

3

pointId

integer

Required

Identifier of the point to which this entry applies.

4

components

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations.

5

phase

real

Required

Phase of the harmonic quantity relative to the reference oscillation.

Accepted words: Constant, Element, Table.

Example record

FrfAssemblyLoadPhase;403;PLATE;15;3;20.

Model containing this record

Reading the example gives id = 403, frfComponent = PLATE, pointId = 15, components = 3.

FrfAssemblyLoadScale

The scale factor of a dynamic load on one degree of freedom of an FRF component, in an FRF based assembly (FBA).

Record format and fields

FrfAssemblyLoadScale;id;frfComponent;pointId;components;scaleFactor

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

frfComponent

any

—

Identifier addressing frf component data.

3

pointId

integer

Required

Identifier of the point to which this entry applies.

4

components

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations.

5

scaleFactor

real

Required

Multiplier applied to the quantity specified by the entry.

Accepted words: Constant, Element, Table.

Example record

FrfAssemblyLoadScale;401;PLATE;15;3;1.

Model containing this record

Reading the example gives id = 401, frfComponent = PLATE, pointId = 15, components = 3.

FrfComponent

A component whose frequency response functions were made by an earlier run and that an FRF based assembly (FBA) puts together with others.

Record format and fields

FrfComponent;id;componentName;medium;unitNumber;lengthScaleFactor;forceScaleFactor

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

componentName

text

—

Text naming the component.

3

medium

text

—

Storage medium supplying the component frequency response functions.

4

unitNumber

integer

0

Logical file unit used to identify an external resource.

5

lengthScaleFactor

real

1.0

Multiplier for length scale.

6

forceScaleFactor

real

1.0

Multiplier for force scale.

Accepted words: All, Assembly, BinaryResultsFile, Component, ConnectionInfo, Constant, Database, Element, Table, UniversalFile.

Example record

FrfComponent;10;PLATE;BinaryResultsFile;25

Model containing this record

Reading the example gives id = 10, componentName = PLATE, medium = BinaryResultsFile, unitNumber = 25.

FrfConnection

An explicit connection between a point of one FRF component and a point of another, in an FRF based assembly (FBA).

Record format and fields

FrfConnection;id;frfComponent1;point1;frfComponent2;point2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

frfComponent1

any

—

Frequency-response component on side 1 of the assembly connection.

3

point1

integer

—

Point at position 1 in the ordered FrfConnection data.

4

frfComponent2

any

—

Frequency-response component on side 2 of the assembly connection.

5

point2

integer

—

Point at position 2 in the ordered FrfConnection data.

Accepted words: Constant, Element, Table.

Example record

FrfConnection;1;PLATE;5;STRUT;201

Model containing this record

Reading the example gives id = 1, frfComponent1 = PLATE, point1 = 5, frfComponent2 = STRUT.

FrfExcitationDof

A degree of freedom where a unit load generates a frequency-response function. pointId identifies a node or scalar point. components is 1 to 6 for a node, 0 or blank for a scalar point. entryLabel is a required literal text value, preserved whole regardless of its length.

Record format and fields

FrfExcitationDof;pointId;components;entryLabel

Position

Field

Type

Default

Meaning and conventions

1

pointId

integer

Required

Identifier of the point to which this entry applies.

2

components

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations.

3

entryLabel

text

—

User label associated with the entry. Written as one text field.

Accepted words: Constant, Element, Table.

Example record

FrfExcitationDof;13;3;UNIT LOAD AT GRID POINT 13 ALONG Z

Model containing this record

Reading the example gives pointId = 13, components = 3, entryLabel = UNIT LOAD AT GRID POINT 13 ALONG Z.

FrfExcitationDofList

Degrees of freedom where unit loads are applied to generate frequency response functions, for a list of points that share their components.

Record format and fields

FrfExcitationDofList;components;<pointIds>

Position

Field

Type

Default

Meaning and conventions

1

components

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations.

Repeated group pointIds. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

pointId

any

—

Identifier of the point to which this entry applies.

Accepted words: Through.

Example record

FrfExcitationDofList;1;202;212

Model containing this record

Reading the example gives components = 1.

FrfFlexibleConnection

The stiffness, damping and structural damping of a flexible connection between a point of one FRF component and a point of another, in an FRF based assembly (FBA).

Record format and fields

FrfFlexibleConnection;id;components;frfComponent1;point1;frfComponent2;point2;stiffnessTableId;stiffness;dampingTableId;damping;structuralDampingTableId;structuralDamping

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

components

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations.

3

frfComponent1

any

—

Frequency-response component on side 1 of the assembly connection.

4

point1

integer

—

Point at position 1 in the ordered FrfFlexibleConnection data.

5

frfComponent2

any

—

Frequency-response component on side 2 of the assembly connection.

6

point2

integer

—

Point at position 2 in the ordered FrfFlexibleConnection data.

7

stiffnessTableId

integer

—

Table supplying the variation of stiffness. Alternative to stiffness.

8

stiffness

real

—

Elastic restoring coefficient relating generalized force to the associated displacement. Alternative to stiffnessTableId.

9

dampingTableId

integer

—

Table supplying the variation of damping. Alternative to damping.

10

damping

real

—

Dissipative coefficient of the selected connection, material or response law. Alternative to dampingTableId.

11

structuralDampingTableId

integer

—

Identifier of the table supplying the structural damping coefficient. Alternative to structuralDamping.

12

structuralDamping

real

—

Structural damping coefficient for the associated material or property. Alternative to structuralDampingTableId.

Accepted words: Constant, Element, Table.

Example record

FrfFlexibleConnection;2;3;PLATE;5;STRUT;201;;1.E+3;;0.5;;0.02

Model containing this record

Reading the example gives id = 2, components = 3, frfComponent1 = PLATE, point1 = 5.

FrfReleasedDofs

Degrees of freedom of the connection grid points of FRF components that an FRF based assembly (FBA) does not connect.

Record format and fields

FrfReleasedDofs;id;components;frfComponent1;node1;frfComponent2;node2;frfComponent3;node3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

components

integer

Required

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations.

3

frfComponent1

any

—

Frequency-response component on side 1 of the assembly connection.

4

node1

integer

—

Grid point to which this entry applies. Entry 1.

5

frfComponent2

any

—

Frequency-response component on side 2 of the assembly connection.

6

node2

integer

—

Grid point to which this entry applies. Entry 2.

7

frfComponent3

any

—

Frequency-response component on side 3 of the assembly connection.

8

node3

integer

—

Grid point to which this entry applies. Entry 3.

Accepted words: Constant, Element, NodePoint2, NodePoint3, Table.

Example record

FrfReleasedDofs;3;456;STRUT;211

Model containing this record

Reading the example gives id = 3, components = 456, frfComponent1 = STRUT, node1 = 211.

FrfSinglePointConstr

Single-point constraints on connection points of FRF components in an FRF based assembly (FBA).

Record format and fields

FrfSinglePointConstr;id;components;frfComponent1;point1;frfComponent2;point2;frfComponent3;point3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

components

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations.

3

frfComponent1

any

—

Frequency-response component on side 1 of the assembly connection.

4

point1

integer

—

Point at position 1 in the ordered FrfSinglePointConstr data.

5

frfComponent2

any

—

Frequency-response component on side 2 of the assembly connection.

6

point2

integer

—

Point at position 2 in the ordered FrfSinglePointConstr data.

7

frfComponent3

any

—

Frequency-response component on side 3 of the assembly connection.

8

point3

integer

—

Point at position 3 in the ordered FrfSinglePointConstr data.

Accepted words: Constant, Element, Point3Kind, Table.

Example record

FrfSinglePointConstr;300;1;PLATE;15

Model containing this record

Reading the example gives id = 300, components = 1, frfComponent1 = PLATE, point1 = 15.

HeatShellNodalLoad

Concentrated static loads, a power input, on the grid points of heat shell elements (those of a ShellPropNonlinear heat transfer property) with a linear or quadratic temperature distribution through the thickness.

Record format and fields

HeatShellNodalLoad;id;node1;components1;heatFlux1;node2;components2;heatFlux2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

node1

integer

—

Identifier addressing node data.

3

components1

integer

1

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1.

4

heatFlux1

real

—

Thermal energy crossing unit area per unit time. Entry 1.

5

node2

integer

—

Grid point to which this entry applies. Entry 2.

6

components2

integer

1

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2.

7

heatFlux2

real

—

Thermal energy crossing unit area per unit time. Entry 2.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • node1 — the card needs at least one load.

  • node2 — the card gives the loads on at most two grid points.

Example record

HeatShellNodalLoad;10;3;1;50.;6;2;50.

Model containing this record

Reading the example gives id = 10, node1 = 3, components1 = 1, heatFlux1 = 50..

Referenced records in this example

  • Node via node1 = 3.

HybridDamping

The hybrid modal damping of a direct dynamic solution.

Record format and fields

HybridDamping;id;methodId;modalDampingTableId;dampingInStiffness;printEigenvalues

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

methodId

integer

Required

Identifier selecting the method record or set.

3

modalDampingTableId

integer

Required

Table supplying the variation of modal damping.

4

dampingInStiffness

text

—

Specifies inclusion of damping contributions in the stiffness representation.

5

printEigenvalues

text

—

Switch controlling the listing of the extracted roots.

Accepted words: Constant, Element, No, Table, Yes.

Example record

HybridDamping;71;72;73;Yes

Model containing this record

Reading the example gives id = 71, methodId = 72, modalDampingTableId = 73, dampingInStiffness = Yes.

HybridDampingRotorOptions

Selects structural, material and Rayleigh damping contributions for hybrid modal damping of a rotor.

Record format and fields

HybridDampingRotorOptions;id;structuralDamping;alphaCoefficient1;alphaCoefficient2;hybridDampingId;structuralDampingFactor;rotorSeparation;structuralDampingFrequency;materialDampingFrequency;hybridDampingFrequency

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

structuralDamping

real

0.0

Structural damping coefficient for the associated material or property.

3

alphaCoefficient1

real

0.0

Coefficient in the relation for alpha.

4

alphaCoefficient2

real

0.0

Coefficient in the relation for alpha.

5

hybridDampingId

integer

0

Identifier selecting the hybrid damping record or set.

6

structuralDampingFactor

real

1.0

Multiplier for structural damping.

7

rotorSeparation

text

—

Separation used in the rotor representation, in length units.

8

structuralDampingFrequency

real

0.0

Structural damping frequency (inverse time).

9

materialDampingFrequency

real

0.0

Material damping frequency (inverse time).

10

hybridDampingFrequency

real

0.0

Hybrid damping frequency (inverse time).

Accepted words: Constant, Element, No, Table, Yes.

Example record

HybridDampingRotorOptions;70;0.01;;;71

Model containing this record

Reading the example gives id = 70, structuralDamping = 0.01, hybridDampingId = 71.

InitialElemValues

The initial values of element variables of the elements of an IdListSet1, at the start of the analysis.

Record format and fields

InitialElemValues;id;elementSetId;<variables>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

elementSetId

integer

Required

Identifier selecting the element set record or set.

Repeated group variables. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

variableName

text

—

Text naming the variable.

2

variableValue

real

—

Value of the independent or design variable at the selected evaluation point.

Accepted words: ArtificialViscosity, CenterX, CenterY, CenterZ, Constant, Decay, Density, Divergence, Element, MaterialFraction, MomentumX, MomentumY, MomentumZ, RadialVelocity, SpecificInternalEnergy, Table, TableDynamic1, VelocityX, VelocityY, VelocityZ, VoidFraction.

Example record

InitialElemValues;81;5;Density;1.2E-11;SpecificInternalEnergy;2.08E+11

Model containing this record

Reading the example gives id = 81, elementSetId = 5.

InitialValuesUserRoutine

Initial values of element or grid point variables that a user written subroutine computes.

Record format and fields

InitialValuesUserRoutine;id;group;routineName;elementSetId;target

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

group

text

—

Grouping key for entries treated together.

3

routineName

text

—

Text naming the routine.

4

elementSetId

integer

Required

Identifier selecting the element set record or set.

5

target

text

—

Requested target of the selected search or output operation.

Accepted words: Constant, Element, ExternalInitialValues, Node, Table.

Example record

InitialValuesUserRoutine;30;initex;ExternalInitialValues;31;Node

Model containing this record

Reading the example gives id = 30, group = initex, routineName = ExternalInitialValues, elementSetId = 31.

InitialVelocityField

An initial velocity field of grid points made of a translation and a rotation about a grid point.

Record format and fields

InitialVelocityField;id;node;scaleFactor;xVelocity;yVelocity;zVelocity;xRotation;yRotation;zRotation;<initializedNodes>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

node

integer

Required

Grid point to which this entry applies.

3

scaleFactor

real

1.0

Multiplier applied to the quantity specified by the entry.

4

xVelocity

real

0.0

X velocity (length per time).

5

yVelocity

real

0.0

Y velocity (length per time).

6

zVelocity

real

0.0

Z velocity (length per time).

7

xRotation

real

0.0

The rotation velocity about G.

8

yRotation

real

0.0

Rotation about the y axis of the specified reference frame.

9

zRotation

real

0.0

Rotation about the z axis of the specified reference frame.

Repeated group initializedNodes. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

initializedNode

any

—

Grid point whose dynamic initial state is being assigned.

Accepted words: By, Constant, Element, Table, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • node1 — the card needs the grid points to initialize.

Example record

InitialVelocityField;81;1;1.;1.E+4;0.;0.;0.;0.;0.;1;Through;8

Model containing this record

Reading the example gives id = 81, node = 1, scaleFactor = 1., xVelocity = 1.E+4.

LanczosEigenMethod

Real eigenvalue extraction by the Lanczos method.

Record format and fields

LanczosEigenMethod;id;lowerFrequency;upperFrequency;desiredModeCount;messageLevel;maximumSet;shiftScale;norm;<options>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the method namespace.

2

lowerFrequency

real

—

Lower frequency (inverse time).

3

upperFrequency

real

—

Upper frequency (inverse time).

4

desiredModeCount

integer

0

Number of desired mode entries.

5

messageLevel

integer

0

Diagnostic level.

6

maximumSet

integer

0

Maximum Lanczos block size. A blank field leaves the block size to the implementation.

7

shiftScale

real

—

Multiplier applied to the eigenvalue search shift.

8

norm

text

—

Norm used for scaling a mode shape.

Repeated group options. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

option

text

—

Selects how the current entry or group is interpreted.

Accepted words: Mass, Maximum.

Accepted parameter names: Alpha, DesiredModeCount, FrequencySegmentCount, LowerFrequency, MaximumSet, MessageLevel, Normalization, SegmentFrequency1, SegmentFrequency10, SegmentFrequency11, SegmentFrequency12, SegmentFrequency13, SegmentFrequency14, SegmentFrequency15, SegmentFrequency2, SegmentFrequency3, SegmentFrequency4, SegmentFrequency5, SegmentFrequency6, SegmentFrequency7, SegmentFrequency8, SegmentFrequency9, ShiftScale, UpperFrequency.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the method ID must be a positive integer.

Example record

LanczosEigenMethod;1;;3.E+3;4

Model containing this record

Reading the example gives id = 1, upperFrequency = 3.E+3, desiredModeCount = 4.

NonlinearNegativePowerLoad4

A nonlinear load that is a negative variable raised to a power.

Record format and fields

NonlinearNegativePowerLoad4;id;nodeI;componentsI;scaleFactor;nodeJ;componentsJ;exponent

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

nodeI

integer

Required

Identifier addressing scalar or grid point data.

3

componentsI

integer

0

Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6.

4

scaleFactor

real

Required

Multiplier applied to the quantity specified by the entry.

5

nodeJ

integer

Required

Identifier addressing scalar or grid point data.

6

componentsJ

integer

0

Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6.

7

exponent

real

Required

Power applied to the associated variable in the stated relation.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the nonlinear load set ID must be a positive integer.

  • nodeI — the point ID must be a positive integer.

  • nodeJ — the point ID must be a positive integer.

Example record

NonlinearNegativePowerLoad4;70;5;3;-0.5;5;3;3.

Model containing this record

Reading the example gives id = 70, nodeI = 5, componentsI = 3, scaleFactor = -0.5.

NonlinearPositivePowerLoad3

A nonlinear load that is a positive variable raised to a power.

Record format and fields

NonlinearPositivePowerLoad3;id;nodeI;componentsI;scaleFactor;nodeJ;componentsJ;exponent

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

nodeI

integer

Required

Identifier addressing scalar or grid point data.

3

componentsI

integer

0

Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6.

4

scaleFactor

real

Required

Multiplier applied to the quantity specified by the entry.

5

nodeJ

integer

Required

Identifier addressing scalar or grid point data.

6

componentsJ

integer

0

Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6.

7

exponent

real

Required

Power applied to the associated variable in the stated relation.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the nonlinear load set ID must be a positive integer.

  • nodeI — the point ID must be a positive integer.

  • nodeJ — the point ID must be a positive integer.

Example record

NonlinearPositivePowerLoad3;70;5;3;-0.5;5;3;3.

Model containing this record

Reading the example gives id = 70, nodeI = 5, componentsI = 3, scaleFactor = -0.5.

NonlinearProductLoad2

A nonlinear load that is the product of two variables.

Record format and fields

NonlinearProductLoad2;id;nodeI;componentsI;scaleFactor;nodeJ;componentsJ;nodeK;componentsK

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

nodeI

integer

Required

Identifier addressing scalar or grid point data.

3

componentsI

integer

0

Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6.

4

scaleFactor

real

Required

Multiplier applied to the quantity specified by the entry.

5

nodeJ

integer

Required

Identifier addressing scalar or grid point data.

6

componentsJ

integer

0

Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6.

7

nodeK

integer

Required

Identifier addressing scalar or grid point data.

8

componentsK

integer

0

Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the nonlinear load set ID must be a positive integer.

  • nodeI — the point ID must be a positive integer.

  • nodeJ — the point ID must be a positive integer.

  • nodeK — the point ID must be a positive integer.

Example record

NonlinearProductLoad2;70;10;3;-0.001;10;13;10;3

Model containing this record

Reading the example gives id = 70, nodeI = 10, componentsI = 3, scaleFactor = -0.001.

NonlinearTableLoad1

A nonlinear load that is a tabular function of a displacement or a velocity.

Record format and fields

NonlinearTableLoad1;id;nodeI;componentsI;scaleFactor;nodeJ;componentsJ;tableId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

nodeI

integer

Required

Identifier addressing scalar or grid point data.

3

componentsI

integer

0

Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6.

4

scaleFactor

real

Required

Multiplier applied to the quantity specified by the entry.

5

nodeJ

integer

Required

Identifier addressing scalar or grid point data.

6

componentsJ

integer

0

Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6.

7

tableId

integer

Required

Identifier of the tabulated function to evaluate.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the nonlinear load set ID must be a positive integer.

  • nodeI — the point ID must be a positive integer.

  • nodeJ — the point ID must be a positive integer.

  • tableId — the table ID must be a positive integer.

Example record

NonlinearTableLoad1;70;15;3;1.;15;3;73

Model containing this record

Reading the example gives id = 70, nodeI = 15, componentsI = 3, scaleFactor = 1..

Referenced records in this example

RandomSpectralDensity

A power spectral density factor of a random analysis.

Record format and fields

RandomSpectralDensity;id;subcaseJ;subcaseK;realPart;imaginaryPart;tableId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

subcaseJ

integer

Required

The subcase of the excited load set.

3

subcaseK

integer

Required

The subcase of the applied load set (K >= J).

4

realPart

real

0.0

In-phase component of the complex quantity.

5

imaginaryPart

real

0.0

Quadrature component of the complex quantity.

6

tableId

integer

0

Identifier of the tabulated function to evaluate.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the random analysis set ID must be a positive integer.

Example record

RandomSpectralDensity;90;1;1;1.;0.;91

Model containing this record

Reading the example gives id = 90, subcaseJ = 1, subcaseK = 1, realPart = 1..

Referenced records in this example

RandomTimeLags

The time lags of the autocorrelation function of a random analysis.

Record format and fields

RandomTimeLags;id;count;startTime;maximumTime

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

count

integer

Required

Number of entries to process in this group.

3

startTime

real

Required

Start time (time).

4

maximumTime

real

Required

Maximum time (time).

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the random analysis set ID must be a positive integer.

Example record

RandomTimeLags;90;10;0.001;0.05

Model containing this record

Reading the example gives id = 90, count = 10, startTime = 0.001, maximumTime = 0.05.

RealEigenMethod

Real eigenvalue extraction, with the method named on the card.

Record format and fields

RealEigenMethod;id;method;frequency1;frequency2;estimatedModeCount;desiredModeCount;normalization;normNode;normComponent

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the method namespace.

2

method

text

Lanczos

Selects the method for RealEigenMethod.

3

frequency1

real

—

Number of cycles per unit time. Entry 1.

4

frequency2

real

—

Number of cycles per unit time. Entry 2.

5

estimatedModeCount

integer

0

Number of estimated mode entries.

6

desiredModeCount

integer

—

Number of desired mode entries.

7

normalization

text

Mass

Rule used to scale the amplitude of an eigenvector.

8

normNode

integer

0

Identifier addressing node data.

9

normComponent

integer

0

Degree of freedom used as the normalization reference.

Accepted words: AutomaticGivens, AutomaticHouseholder, Givens, Householder, InverseIteration, Lanczos, Mass, Maximum, ModifiedGivens, ModifiedHouseholder, Point, SturmInverse.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the method ID must be a positive integer.

Example record

RealEigenMethod;71;Lanczos;;;;8;Mass

Model containing this record

Reading the example gives id = 71, method = Lanczos, desiredModeCount = 8, normalization = Mass.

RotorHybridDamping

Associates individual rotors with their hybrid modal damping definitions.

Record format and fields

RotorHybridDamping;<pairs>

This part of the record has no fixed fields.

Repeated group pairs. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

rotorId

integer

—

Identifier selecting the rotor record or set.

2

hybridDampingId

integer

—

Identifier selecting the hybrid damping record or set.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • rotorId1 — the card needs at least one pair of a rotor and a hybrid damping.

Example record

RotorHybridDamping;10;11

Model containing this record

RotorUnbalanceLoad

A rotating unbalance load of a rotordynamic transient or frequency response analysis.

Record format and fields

RotorUnbalanceLoad;id;massTableId;mass;nodeId;directionX;directionY;directionZ;radialOffsetTableId;radialOffset;angularPosition;axialOffsetTableId;axialOffset;startTimeOrFrequency;stopTimeOrFrequency;correctionFlag;forcePointT1;forcePointT2;forcePointT3;forcePointR1;forcePointR2;forcePointR3;massCorrectionPointT1;massCorrectionPointT2;massCorrectionPointT3;massCorrectionPointR1;massCorrectionPointR2;massCorrectionPointR3;speedCorrectionPoint1;speedCorrectionPoint2;speedCorrectionPoint3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

massTableId

integer

—

Table supplying the variation of mass. Alternative to mass.

3

mass

real

—

Inertial mass associated with the selected component or body. Alternative to massTableId.

4

nodeId

integer

Required

Identifier of the grid point addressed by this record.

5

directionX

real

Required

X component of the specified direction vector in its reference frame.

6

directionY

real

Required

Y component of the specified direction vector in its reference frame.

7

directionZ

real

Required

Z component of the specified direction vector in its reference frame.

8

radialOffsetTableId

integer

—

Table supplying the variation of radial offset. Alternative to radialOffset.

9

radialOffset

real

1.0

Distance from the reference axis in the radial direction. Alternative to radialOffsetTableId.

10

angularPosition

real

0.0

The angular position of the mass, in degrees.

11

axialOffsetTableId

integer

—

Table supplying the variation of axial offset. Alternative to axialOffset.

12

axialOffset

real

0.0

Distance from the reference position measured along the rotation axis. Alternative to axialOffsetTableId.

13

startTimeOrFrequency

real

0.0

Start time or frequency (inverse time).

14

stopTimeOrFrequency

real

999999.0

Stop time or frequency (inverse time).

15

correctionFlag

text

None

Selects the correction flag for RotorUnbalanceLoad.

16

forcePointT1

integer

0

Extra point for unbalance force output, component 1 of the T group (T for translations, R for rotations).

17

forcePointT2

integer

0

Extra point for unbalance force output, component 2 of the T group (T for translations, R for rotations).

18

forcePointT3

integer

0

Extra point for unbalance force output, component 3 of the T group (T for translations, R for rotations).

19

forcePointR1

integer

0

Extra point for unbalance force output, component 1 of the R group (T for translations, R for rotations).

20

forcePointR2

integer

0

Extra point for unbalance force output, component 2 of the R group (T for translations, R for rotations).

21

forcePointR3

integer

0

Extra point for unbalance force output, component 3 of the R group (T for translations, R for rotations).

22

massCorrectionPointT1

integer

0

Extra point for the mass correction, component 1 of the T group (T for translations, R for rotations).

23

massCorrectionPointT2

integer

0

Extra point for the mass correction, component 2 of the T group (T for translations, R for rotations).

24

massCorrectionPointT3

integer

0

Extra point for the mass correction, component 3 of the T group (T for translations, R for rotations).

25

massCorrectionPointR1

integer

0

Extra point for the mass correction, component 1 of the R group (T for translations, R for rotations).

26

massCorrectionPointR2

integer

0

Extra point for the mass correction, component 2 of the R group (T for translations, R for rotations).

27

massCorrectionPointR3

integer

0

Extra point for the mass correction, component 3 of the R group (T for translations, R for rotations).

28

speedCorrectionPoint1

integer

0

Extra point for spin-rate correction component 1.

29

speedCorrectionPoint2

integer

0

Extra point for spin-rate correction component 2.

30

speedCorrectionPoint3

integer

0

Extra point for spin-rate correction component 3.

Accepted words: Acceleration, Both, Displacement, Load, Mass, None, Speed, Velocity.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the set ID must be a positive integer.

Example record

RotorUnbalanceLoad;300;;1.E-5;1003;0.;1.;0.;;10.;0.;;0.

Model containing this record

Reading the example gives id = 300, mass = 1.E-5, nodeId = 1003, directionX = 0..

TransferFunction

Relates a dependent degree of freedom to independent inputs using coefficients of the value and its first two time derivatives.

Record format and fields

TransferFunction;id;nodeD;componentsD;coefficientB0;coefficientB1;coefficientB2;<terms>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

nodeD

integer

Required

Identifier addressing scalar or grid point data.

3

componentsD

integer

0

Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6.

4

coefficientB0

real

0.0

Coefficient B0 in the TransferFunction relation.

5

coefficientB1

real

0.0

Coefficient B1 in the TransferFunction relation.

6

coefficientB2

real

0.0

Coefficient B2 in the TransferFunction relation.

Repeated group terms. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

termNode

integer

—

Point identifier for the associated term.

2

termComponents

integer

—

Degrees of freedom involved in the associated term.

3

coefficientA0

real

—

Coefficient A0 in the TransferFunction relation for terms.

4

coefficientA1

real

—

Coefficient A1 in the TransferFunction relation for terms.

5

coefficientA2

real

—

Coefficient A2 in the TransferFunction relation for terms.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the set ID must be a positive integer.

Example record

TransferFunction;60;901;;1.;;;15;3;-1.

Model containing this record

Reading the example gives id = 60, nodeD = 901, coefficientB0 = 1..

TransientFormulaLoad2

A transient excitation given by a formula, for T1 <= t <= T2 and zero elsewhere: P(t) = A * t’^B * exp(C * t’) * cos(2 * pi * F * t’ + P), with t’ = t - T1 - tau.

Record format and fields

TransientFormulaLoad2;id;excitationId;delayId;delay;kind;time1;time2;frequency;phase;coefficientC;exponentB;initialDisplacementFactor;initialVelocityFactor

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

excitationId

integer

Required

Identifier selecting the excitation record or set.

3

delayId

integer

—

Identifier selecting the delay record or set. Alternative to delay.

4

delay

real

0.0

Time shift relative to the reference excitation, in model time units. Alternative to delayId.

5

kind

any

Load

Selects the kind for TransientFormulaLoad2.

6

time1

real

0.0

Time 1 (time).

7

time2

real

same as time1

Time 2 (time).

8

frequency

real

0.0

Number of cycles per unit time.

9

phase

real

0.0

Phase of the harmonic quantity relative to the reference oscillation.

10

coefficientC

real

0.0

Coefficient C in the TransientFormulaLoad2 relation.

11

exponentB

real

0.0

The growth coefficient.

12

initialDisplacementFactor

real

0.0

Multiplier for initial displacement.

13

initialVelocityFactor

real

0.0

Multiplier for initial velocity.

Accepted words: Acceleration, Displacement, Load, Velocity.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the dynamic load set ID must be a positive integer.

Example record

TransientFormulaLoad2;51;2;;;Load;0.;0.05;0.;0.

Model containing this record

Reading the example gives id = 51, excitationId = 2, kind = Load, time1 = 0..

TransientInitialCondition

The initial displacement and velocity of one degree of freedom of a transient analysis.

Record format and fields

TransientInitialCondition;id;node;components;initialDisplacement;initialVelocity

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

node

integer

Required

Grid point to which this entry applies.

3

components

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations.

4

initialDisplacement

real

0.0

The initial displacement.

5

initialVelocity

real

0.0

Initial velocity (length per time).

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the set ID must be a positive integer.

Example record

TransientInitialCondition;81;15;3;0.;50.

Model containing this record

Reading the example gives id = 81, node = 15, components = 3, initialDisplacement = 0..

TransientTableLoad1

A transient excitation P(t) = A * F(t - tau), where F is a table.

Record format and fields

TransientTableLoad1;id;excitationId;delayId;delay;kind;tableId;functionValue;initialDisplacementFactor;initialVelocityFactor

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

excitationId

integer

Required

Identifier selecting the excitation record or set.

3

delayId

integer

—

Identifier selecting the delay record or set. Alternative to delay.

4

delay

real

0.0

Time shift relative to the reference excitation, in model time units. Alternative to delayId.

5

kind

any

Load

Selects the kind for TransientTableLoad1.

6

tableId

integer

—

Identifier of the tabulated function to evaluate. Alternative to functionValue.

7

functionValue

real

0.0

Value of the tabulated function at this sample. Alternative to tableId.

8

initialDisplacementFactor

real

0.0

Multiplier for initial displacement.

9

initialVelocityFactor

real

0.0

Multiplier for initial velocity.

Accepted words: Acceleration, Displacement, Load, Velocity.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the dynamic load set ID must be a positive integer.

Example record

TransientTableLoad1;1;2;;;0;3

Model containing this record

Reading the example gives id = 1, excitationId = 2, kind = 0, tableId = 3.