Heat transfer

All card families and alphabetical index

Read field positions from left to right within each table. A dash means the layout supplies no fixed default. Use a consistent system of units for dimensional quantities.

AcousticAbsorber

A frequency-dependent acoustic absorber element on the fluid-structure boundary.

Record format and fields

AcousticAbsorber;id;propId;node1;node2;node3;node4

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

Required

Grid point to which this entry applies. Entry 1.

4

node2

integer

0

Grid point to which this entry applies. Entry 2.

5

node3

integer

0

Grid point to which this entry applies. Entry 3.

6

node4

integer

0

Grid point to which this entry applies. Entry 4.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node — a grid point ID cannot be negative.

Example record

AcousticAbsorber;401;31;1001;1101;1106;1006

Model containing this record

Reading the example gives id = 401, propId = 31, node1 = 1001, node2 = 1101.

Referenced records in this example

AcousticAbsorberBrickProp

The property of an AcousticAbsorberHexa acoustic absorber element.

Record format and fields

AcousticAbsorberBrickProp;id;synthesize;resistanceTableId;reactanceTableId;weightingTableId;reservedValue;cutoffFrequency;damping;stiffness;mass

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

synthesize

text

—

Selects between an equivalent response derived from tables and directly supplied coefficients.

3

resistanceTableId

integer

0

Table defining the resistive part of the acoustic response.

4

reactanceTableId

integer

0

Table defining the reactive part of the acoustic response.

5

weightingTableId

integer

0

Optional frequency weighting table used in coefficient synthesis.

6

reservedValue

real

—

Optional value retained at a reserved position when the record is read and written.

7

cutoffFrequency

real

—

Frequency at which the specified range of the response ends (inverse time).

8

damping

real

—

Equivalent damping per unit surface area.

9

stiffness

real

—

Equivalent stiffness per unit surface area.

10

mass

real

—

Equivalent mass per unit surface area.

Accepted words: No, Yes.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the property ID must be a positive integer.

  • resistanceTableId — a table ID cannot be negative.

Example record

AcousticAbsorberBrickProp;21;No;;;;;;1.E-6;0.01;3.E-10

Model containing this record

Reading the example gives id = 21, synthesize = No, damping = 1.E-6, stiffness = 0.01.

AcousticAbsorberHexa

An acoustic absorber element, a brick of the coupled fluid-structure analysis.

Record format and fields

AcousticAbsorberHexa;id;propId;node1;node2;node3;node4;node5;node6;node7;node8;node9;node10;node11;node12;node17;node18;node19;node20

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

node5

integer

—

Grid point to which this entry applies. Entry 5.

8

node6

integer

—

Grid point to which this entry applies. Entry 6.

9

node7

integer

—

Grid point to which this entry applies. Entry 7.

10

node8

integer

—

Grid point to which this entry applies. Entry 8.

11

node9

integer

—

Grid point to which this entry applies. Entry 9.

12

node10

integer

—

Grid point to which this entry applies. Entry 10.

13

node11

integer

—

Grid point to which this entry applies. Entry 11.

14

node12

integer

—

Grid point to which this entry applies. Entry 12.

15

node17

integer

—

Grid point to which this entry applies. Entry 17.

16

node18

integer

—

Grid point to which this entry applies. Entry 18.

17

node19

integer

—

Grid point to which this entry applies. Entry 19.

18

node20

integer

—

Grid point to which this entry applies. Entry 20.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node — a grid point ID cannot be negative.

  • node — a grid point is repeated in the element.

Example record

AcousticAbsorberHexa;301;21;101;102;107;106;501;502;507;506

Model containing this record

Reading the example gives id = 301, propId = 21, node1 = 101, node2 = 102.

Referenced records in this example

AcousticBarrierHexa

An acoustic barrier element, a brick of the coupled fluid-structure analysis.

Record format and fields

AcousticBarrierHexa;id;propId;node1;node2;node3;node4;node5;node6;node7;node8;node9;node10;node11;node12;node17;node18;node19;node20

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

node5

integer

—

Grid point to which this entry applies. Entry 5.

8

node6

integer

—

Grid point to which this entry applies. Entry 6.

9

node7

integer

—

Grid point to which this entry applies. Entry 7.

10

node8

integer

—

Grid point to which this entry applies. Entry 8.

11

node9

integer

—

Grid point to which this entry applies. Entry 9.

12

node10

integer

—

Grid point to which this entry applies. Entry 10.

13

node11

integer

—

Grid point to which this entry applies. Entry 11.

14

node12

integer

—

Grid point to which this entry applies. Entry 12.

15

node17

integer

—

Grid point to which this entry applies. Entry 17.

16

node18

integer

—

Grid point to which this entry applies. Entry 18.

17

node19

integer

—

Grid point to which this entry applies. Entry 19.

18

node20

integer

—

Grid point to which this entry applies. Entry 20.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node — a grid point ID cannot be negative.

  • node — a grid point is repeated in the element.

Example record

AcousticBarrierHexa;309;22;111;112;117;116;511;512;517;516

Model containing this record

Reading the example gives id = 309, propId = 22, node1 = 111, node2 = 112.

Referenced records in this example

AcousticBarrierProp

The property of an AcousticBarrierHexa acoustic barrier element.

Record format and fields

AcousticBarrierProp;id;backingMass;septumMass;resonanceFrequency;resonanceStiffness

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

backingMass

real

Required

Mass assigned to the backing layer of the acoustic treatment.

3

septumMass

real

Required

Mass assigned to the separating septum in the acoustic treatment.

4

resonanceFrequency

real

—

Resonance frequency (inverse time).

5

resonanceStiffness

real

—

Stiffness governing the resonant response of the acoustic layer.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the property ID must be a positive integer.

Example record

AcousticBarrierProp;22;2.E-9;1.E-9;300.

Model containing this record

Reading the example gives id = 22, backingMass = 2.E-9, septumMass = 1.E-9, resonanceFrequency = 300..

AcousticSlotBoundary

The list of the AcousticSlotSurfacePoint slot points on the boundary of a slot cavity with the axisymmetric fluid cavity.

Record format and fields

AcousticSlotBoundary;density;slotCount;<slotPoints>

Position

Field

Type

Default

Meaning and conventions

1

density

real

—

Mass per unit volume for a volumetric material or fluid density.

2

slotCount

integer

—

Number of slot entries.

Repeated group slotPoints. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

slotPoint

integer

—

Point defining the location on the acoustic slot.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • slotPoint2 — the card needs at least two slot points.

Example record

AcousticSlotBoundary;;;21;22;23

Model containing this record

AxisymFluid2

Defines an axisymmetric fluid element generated by revolving a two-corner cross-section.

Record format and fields

AxisymFluid2;id;fluidPointId1;fluidPointId2;density;bulkModulus

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

fluidPointId1

integer

—

Identifier selecting the fluid point record or set.

3

fluidPointId2

integer

—

Identifier selecting the fluid point record or set.

4

density

real

—

Mass per unit volume for a volumetric material or fluid density.

5

bulkModulus

real

—

Resistance to volumetric compression, expressed as pressure.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • fluidPointId — a fluid point ID must be between 1 and 499999.

  • fluidPointId — the rings of an element are different.

Example record

AxisymFluid2;101;1;3

Model containing this record

Reading the example gives id = 101, fluidPointId1 = 1, fluidPointId2 = 3.

AxisymFluid3

Defines an axisymmetric fluid element generated by revolving a triangular cross-section.

Record format and fields

AxisymFluid3;id;fluidPointId1;fluidPointId2;fluidPointId3;density;bulkModulus

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

fluidPointId1

integer

—

Identifier selecting the fluid point record or set.

3

fluidPointId2

integer

—

Identifier selecting the fluid point record or set.

4

fluidPointId3

integer

—

Identifier selecting the fluid point record or set.

5

density

real

—

Mass per unit volume for a volumetric material or fluid density.

6

bulkModulus

real

—

Resistance to volumetric compression, expressed as pressure.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • fluidPointId — a fluid point ID must be between 1 and 499999.

  • fluidPointId — the rings of an element are different.

Example record

AxisymFluid3;104;3;4;6

Model containing this record

Reading the example gives id = 104, fluidPointId1 = 3, fluidPointId2 = 4, fluidPointId3 = 6.

AxisymFluid4

Defines an axisymmetric fluid element generated by revolving a quadrilateral cross-section.

Record format and fields

AxisymFluid4;id;fluidPointId1;fluidPointId2;fluidPointId3;fluidPointId4;density;bulkModulus

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

fluidPointId1

integer

—

Identifier selecting the fluid point record or set.

3

fluidPointId2

integer

—

Identifier selecting the fluid point record or set.

4

fluidPointId3

integer

—

Identifier selecting the fluid point record or set.

5

fluidPointId4

integer

—

Identifier selecting the fluid point record or set.

6

density

real

—

Mass per unit volume for a volumetric material or fluid density.

7

bulkModulus

real

—

Resistance to volumetric compression, expressed as pressure.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • fluidPointId — a fluid point ID must be between 1 and 499999.

  • fluidPointId — the rings of an element are different.

Example record

AxisymFluid4;103;1;2;4;3

Model containing this record

Reading the example gives id = 103, fluidPointId1 = 1, fluidPointId2 = 2, fluidPointId3 = 4.

AxisymFluidBoundaryList

The fluid points (AxisymFluidRing) of the boundary between an axisymmetric fluid and a structure.

Record format and fields

AxisymFluidBoundaryList;density;<fluidPoints>

Position

Field

Type

Default

Meaning and conventions

1

density

real

—

Mass per unit volume for a volumetric material or fluid density.

Repeated group fluidPoints. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

fluidPointId

any

—

Identifier selecting the fluid point record or set.

Accepted words: Axis, LocalAxis.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • fluidPointId — the card needs at least one fluid point.

  • fluidPointId — a fluid point ID must be a positive integer.

Example record

AxisymFluidBoundaryList;0.;11;12;13

Model containing this record

Reading the example gives density = 0..

AxisymFluidFreeSurface

The fluid points (AxisymFluidRing) of a free surface boundary of an axisymmetric fluid model.

Record format and fields

AxisymFluidFreeSurface;density;<fluidPoints>

Position

Field

Type

Default

Meaning and conventions

1

density

real

—

Mass per unit volume for a volumetric material or fluid density.

Repeated group fluidPoints. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

fluidPointId

any

—

Identifier selecting the fluid point record or set.

Accepted words: Axis, LocalAxis.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • fluidPointId — the card needs at least one fluid point.

  • fluidPointId — a fluid point ID must be a positive integer.

Example record

AxisymFluidFreeSurface;;Axis;5;6

Model containing this record

AxisymFluidSymmetry

The symmetry of the structural boundary of an axisymmetric fluid model.

Record format and fields

AxisymFluidSymmetry;sectionCount;planeSymmetry1;planeSymmetry2

Position

Field

Type

Default

Meaning and conventions

1

sectionCount

integer

Required

Number of section entries.

2

planeSymmetry1

text

—

Symmetry condition on reference plane 1 in the fluid model.

3

planeSymmetry2

text

—

Symmetry condition on reference plane 2 in the fluid model.

Accepted words: Antisymmetric, Symmetric.

Example record

AxisymFluidSymmetry;4;Symmetric;Symmetric

Model containing this record

Reading the example gives sectionCount = 4, planeSymmetry1 = Symmetric, planeSymmetry2 = Symmetric.

FluidMassElemList

A list of ShellQuad4 and ShellTria3 elements for the virtual fluid mass of a FluidVirtualMass.

Record format and fields

FluidMassElemList;id;<elements>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group elements. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

elemId

any

—

Identifier of the element addressed by this record.

Accepted words: Constant, Element, Table, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • elemId1 — the card needs at least one element.

  • elemId1 — an element ID must not be zero (a minus sign gives the wetted side).

Example record

FluidMassElemList;1;1;Through;4;-11;Through;-18;-21;Through;-28

Model containing this record

Reading the example gives id = 1.

FluidStructureInterface

Fluid-structure interface parameters.

Record format and fields

FluidStructureInterface;interfaceKind;interfaceInput;fluidSetId;structureSetId;normalTolerance;methodName;skinTolerance;skinToleranceIncrement;interfaceTolerance;wholeStructureSet;searchUnit

Position

Field

Type

Default

Meaning and conventions

1

interfaceKind

text

—

Selects the interface kind for FluidStructureInterface.

2

interfaceInput

text

—

Selects the input data supplied at the coupled interface.

3

fluidSetId

integer

0

Identifier addressing set data.

4

structureSetId

integer

0

Identifier addressing set data.

5

normalTolerance

real

—

Permitted numerical deviation for normal.

6

methodName

text

SurfaceCoupling

Text naming the method.

7

skinTolerance

real

0.5

Permitted numerical deviation for skin.

8

skinToleranceIncrement

real

0.75

Increment applied to the skin tolerance in the surface search.

9

interfaceTolerance

real

0.5

Permitted numerical deviation for interface.

10

wholeStructureSet

text

—

Set containing all structural entities used in this coupling.

11

searchUnit

text

—

Logical unit or search setting used by the associated integration routine.

Accepted words: Absolute, All, ClosedPressure, DifferenceForm, ElemsList, IdenticalMesh, No, NodesList, None, Relative, ScaledSurfaceCoupling, SurfaceCoupling, Yes.

Example record

FluidStructureInterface;DifferenceForm;None;;;0.5;SurfaceCoupling;0.5;0.75;0.5;No;Absolute

Model containing this record

Reading the example gives interfaceKind = DifferenceForm, interfaceInput = None, normalTolerance = 0.5, methodName = SurfaceCoupling.

FluidStructurePanels

Panels of the structure for the panel participation of a coupled fluid-structure analysis.

Record format and fields

FluidStructurePanels;<panels>

This part of the record has no fixed fields.

Repeated group panels. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

panelName

text

—

Text naming the panel.

2

panelSetId

integer

—

Identifier addressing set data.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • panelName — the card needs at least one panel.

  • panelSetId — the card has one set ID for each name.

  • panelName — the name of a panel cannot be blank.

  • panelSetId — a set ID must be a positive integer.

Example record

FluidStructurePanels;FLOOR;41

Model containing this record

FluidVirtualMass

The properties of an incompressible fluid volume, for the virtual mass matrix.

Record format and fields

FluidVirtualMass;id;frameId;freeSurfaceZ;density;oneSideElemListId;bothSidesElemListId;planeSymmetry1;planeSymmetry2;characteristicLength;exactIntegrationRatio

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

frameId

integer

0

Coordinate system in which this entry is expressed.

3

freeSurfaceZ

real

—

Vertical coordinate of the free surface in the specified frame.

4

density

real

Required

Mass per unit volume for a volumetric material or fluid density.

5

oneSideElemListId

integer

0

Identifier addressing element list data.

6

bothSidesElemListId

integer

0

Identifier addressing element list data.

7

planeSymmetry1

text

—

Symmetry condition on reference plane 1 in the fluid model.

8

planeSymmetry2

text

—

Symmetry condition on reference plane 2 in the fluid model.

9

characteristicLength

real

1.0e10

Characteristic length (length).

10

exactIntegrationRatio

real

1.0e-15

Relative measure of exact integration.

Accepted words: Antisymmetric, NoSymmetry, Symmetric.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the set ID must be a positive integer.

  • oneSideElemListId — an element list ID cannot be negative.

Example record

FluidVirtualMass;1;;80.;1.E-9;1;;NoSymmetry;NoSymmetry

Model containing this record

Reading the example gives id = 1, freeSurfaceZ = 80., density = 1.E-9, oneSideElemListId = 1.

ForcedConvection

Applies forced convection to a tube-type heat-transfer surface.

Record format and fields

ForcedConvection;id;convectionPropId;filmNode;massFlowNode;ambientNode1;ambientNode2;massFlowFactor

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

convectionPropId

integer

Required

Identifier addressing forced convection property data.

3

filmNode

integer

0

Identifier addressing scalar or grid point data.

4

massFlowNode

integer

0

Identifier addressing scalar or grid point data.

5

ambientNode1

integer

Required

Identifier addressing scalar or grid point data.

6

ambientNode2

integer

same as ambientNode1

Identifier addressing scalar or grid point data.

7

massFlowFactor

real

1.0

Multiplier for mass flow.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the surface element ID must be a positive integer.

  • convectionPropId — the forced convection property ID must be a positive integer.

Example record

ForcedConvection;21;22;;;11;12;1.E-5

Model containing this record

Reading the example gives id = 21, convectionPropId = 22, ambientNode1 = 11, ambientNode2 = 12.

Referenced records in this example

ForcedConvectionProp

The forced convection property of the surface elements a ForcedConvection names.

Record format and fields

ForcedConvectionProp;id;matId;matrixForm;massFlowConvection;coefficient;reynoldsExponent;prandtlExponentInner;prandtlExponentOuter

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

3

matrixForm

integer

0

Matrix organization, including the assumed relation between its rows and columns.

4

massFlowConvection

integer

0

Controls the contribution of convective transport associated with mass flow.

5

coefficient

real

Required

Coefficient value in the ForcedConvectionProp relation.

6

reynoldsExponent

real

0.0

Power in the law for reynolds.

7

prandtlExponentInner

real

0.0

Exponent on the Prandtl number in the inner convection correlation.

8

prandtlExponentOuter

real

0.0

Exponent on the Prandtl number in the outer convection correlation.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the convection property ID must be a positive integer.

  • matId — the material ID must be a positive integer.

Example record

ForcedConvectionProp;22;3;1;1;0.023;0.8;0.4;0.3

Model containing this record

Reading the example gives id = 22, matId = 3, matrixForm = 1, massFlowConvection = 1.

Referenced records in this example

FreeConvection

The free convection boundary condition of a surface element.

Record format and fields

FreeConvection;id;convectionPropId;filmNode;controlNode;ambientNode1;ambientNode2;ambientNode3;ambientNode4;ambientNode5;ambientNode6;ambientNode7;ambientNode8

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

convectionPropId

integer

Required

Identifier addressing convection property data.

3

filmNode

integer

0

Identifier addressing scalar or grid point data.

4

controlNode

integer

0

Identifier of the grid point through which this definition is controlled.

5

ambientNode1

integer

Required

Identifier addressing scalar or grid point data.

6

ambientNode2

integer

same as ambientNode1

Grid or scalar point supplying ambient temperature for boundary term 2.

7

ambientNode3

integer

same as ambientNode1

Grid or scalar point supplying ambient temperature for boundary term 3.

8

ambientNode4

integer

same as ambientNode1

Grid or scalar point supplying ambient temperature for boundary term 4.

9

ambientNode5

integer

same as ambientNode1

Grid or scalar point supplying ambient temperature for boundary term 5.

10

ambientNode6

integer

same as ambientNode1

Grid or scalar point supplying ambient temperature for boundary term 6.

11

ambientNode7

integer

same as ambientNode1

Grid or scalar point supplying ambient temperature for boundary term 7.

12

ambientNode8

integer

same as ambientNode1

Grid or scalar point supplying ambient temperature for boundary term 8.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the surface element ID must be a positive integer.

  • convectionPropId — the free convection property ID must be a positive integer.

Example record

FreeConvection;41;43;;;99

Model containing this record

Reading the example gives id = 41, convectionPropId = 43, ambientNode1 = 99.

Referenced records in this example

FreeConvectionProp

The free convection property of the surface elements a FreeConvection names.

Record format and fields

Forms: coefficients, standard.

FreeConvectionProp: coefficients

Form coefficients, when formulaKind is 3.

FreeConvectionProp;id;matId;matrixForm;convectionExponent;formulaKind;convectionCoefficient1;convectionCoefficient2;convectionCoefficient3;convectionCoefficient4;convectionCoefficient5;convectionCoefficient6;convectionCoefficient7;convectionCoefficient8

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

matId

integer

0

Material identifier used to retrieve the constitutive data.

3

matrixForm

integer

0

Matrix organization, including the assumed relation between its rows and columns.

4

convectionExponent

real

0.0

Power in the law for convection.

5

formulaKind

integer

0

Selects the formula kind for FreeConvectionProp.

6

convectionCoefficient1

real

Required

Coefficient in the relation for convection.

7

convectionCoefficient2

real

same as convectionCoefficient1

Coefficient in the relation for convection.

8

convectionCoefficient3

real

same as convectionCoefficient1

Coefficient in the relation for convection.

9

convectionCoefficient4

real

same as convectionCoefficient1

Coefficient in the relation for convection.

10

convectionCoefficient5

real

same as convectionCoefficient1

Coefficient in the relation for convection.

11

convectionCoefficient6

real

same as convectionCoefficient1

Coefficient in the relation for convection.

12

convectionCoefficient7

real

same as convectionCoefficient1

Coefficient in the relation for convection.

13

convectionCoefficient8

real

same as convectionCoefficient1

Coefficient in the relation for convection.

FreeConvectionProp: standard

Form standard, for every other record.

FreeConvectionProp;id;matId;matrixForm;convectionExponent;formulaKind;tableId;characteristicLength;inletNode;directionFrameId;direction1;direction2;direction3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

matId

integer

0

Material identifier used to retrieve the constitutive data.

3

matrixForm

integer

0

Matrix organization, including the assumed relation between its rows and columns.

4

convectionExponent

real

0.0

Power in the law for convection.

5

formulaKind

integer

0

Selects the formula kind for FreeConvectionProp.

6

tableId

integer

0

Identifier of the tabulated function to evaluate.

7

characteristicLength

real

—

Characteristic length (length).

8

inletNode

integer

0

Identifier addressing node data.

9

directionFrameId

integer

0

Identifier addressing coordinate data.

10

direction1

real

—

Orientation in which the specified quantity acts or is measured. Entry 1.

11

direction2

real

—

Orientation in which the specified quantity acts or is measured. Entry 2.

12

direction3

real

—

Orientation in which the specified quantity acts or is measured. Entry 3.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the convection property ID must be a positive integer.

  • matId — the material ID must be positive (or blank).

Example record

FreeConvectionProp;1;1;0;0.

Model containing this record

HeatAnisoMat

The anisotropic heat transfer material of a conduction element.

Record format and fields

HeatAnisoMat;id;conductivityXx;conductivityXy;conductivityXz;conductivityYy;conductivityYz;conductivityZz;specificHeat;density;heatGenerationFactor

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the thermal material namespace.

2

conductivityXx

real

0.0

Thermal conductivity tensor component in the Xx material or local axes.

3

conductivityXy

real

0.0

Thermal conductivity tensor component in the Xy material or local axes.

4

conductivityXz

real

0.0

Thermal conductivity tensor component in the Xz material or local axes.

5

conductivityYy

real

0.0

Thermal conductivity tensor component in the Yy material or local axes.

6

conductivityYz

real

0.0

Thermal conductivity tensor component in the Yz material or local axes.

7

conductivityZz

real

0.0

Thermal conductivity tensor component in the Zz material or local axes.

8

specificHeat

real

0.0

Energy per unit mass required for one unit of temperature change.

9

density

real

1.0

Mass per unit volume for a volumetric material or fluid density.

10

heatGenerationFactor

real

1.0

Multiplier for heat generation.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the material ID must be a positive integer.

Example record

HeatAnisoMat;5;150.;0.;0.;50.;0.;50.;9.E+8;2.7E-9

Model containing this record

Reading the example gives id = 5, conductivityXx = 150., conductivityXy = 0., conductivityXz = 0..

HeatController

Identifies the control applied to a surface or volume heat source, convection condition or radiating boundary.

Record format and fields

HeatController;id;sensorNode;sensorForm;controllerKind;lowerLimit;upperLimit;controlLaw;initialState;timeStep;delayTime;timeConstant

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

sensorNode

integer

Required

A grid point or a scalar point.

3

sensorForm

text

—

Specifies the representation of the sensor used by the thermal control law.

4

controllerKind

text

—

Selects the controller kind for HeatController.

5

lowerLimit

real

Required

Lowest admissible or requested value in the selected range.

6

upperLimit

real

Required

Highest admissible or requested value in the selected range.

7

controlLaw

integer

Required

Relation used to determine the controlled response from its input.

8

initialState

real

0.0

State assigned before stepping the model forward.

9

timeStep

real

0.0

Time increment between successive states, in model time units.

10

delayTime

real

0.0

Delay time (time).

11

timeConstant

real

0.0

Characteristic time scale of the response.

Accepted words: Constant, Element, Table, Temperature, Thermostat.

Example record

HeatController;900;5;Temperature;Thermostat;40.;45.;1;0.

Model containing this record

Reading the example gives id = 900, sensorNode = 5, sensorForm = Temperature, controllerKind = Thermostat.

HeatFluxBoundaryLoad3

A uniform heat flux (or its multiplier) into a boundary surface.

Record format and fields

HeatFluxBoundaryLoad3;id;heatFlux;controlNode;<elements>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

heatFlux

real

Required

Thermal energy crossing unit area per unit time.

3

controlNode

integer

0

Identifier of the grid point through which this definition is controlled.

Repeated group elements. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

elemId

any

—

Identifier of the element addressed by this record.

Accepted words: By, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the load set ID must be a positive integer.

Example record

HeatFluxBoundaryLoad3;10;0.4;900;21;Through;24

Model containing this record

Reading the example gives id = 10, heatFlux = 0.4, controlNode = 900.

HeatFluxNodalLoad2

The heat flux at each grid point of one surface element.

Record format and fields

HeatFluxNodalLoad2;id;elemId;heatFlux1;heatFlux2;heatFlux3;heatFlux4;heatFlux5;heatFlux6;heatFlux7;heatFlux8

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

elemId

integer

Required

Identifier of the element addressed by this record.

3

heatFlux1

real

—

Thermal energy crossing unit area per unit time. Entry 1.

4

heatFlux2

real

—

Thermal energy crossing unit area per unit time. Entry 2.

5

heatFlux3

real

—

Thermal energy crossing unit area per unit time. Entry 3.

6

heatFlux4

real

—

Thermal energy crossing unit area per unit time. Entry 4.

7

heatFlux5

real

—

Thermal energy crossing unit area per unit time. Entry 5.

8

heatFlux6

real

—

Thermal energy crossing unit area per unit time. Entry 6.

9

heatFlux7

real

—

Thermal energy crossing unit area per unit time. Entry 7.

10

heatFlux8

real

—

Thermal energy crossing unit area per unit time. Entry 8.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the load set ID must be a positive integer.

  • elemId — the surface element ID must be a positive integer.

Example record

HeatFluxNodalLoad2;1;241;0.3;0.3;0.4;0.4

Model containing this record

Reading the example gives id = 1, elemId = 241, heatFlux1 = 0.3, heatFlux2 = 0.3.

Referenced records in this example

HeatFluxNodeSetLoad

A uniform heat flux into a set of grid points.

Record format and fields

HeatFluxNodeSetLoad;id;faceKind;heatFlux;area;node1;node2;node3;node4;node5;node6;node7;node8

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

faceKind

text

—

Selects the face kind for HeatFluxNodeSetLoad.

3

heatFlux

real

Required

Thermal energy crossing unit area per unit time.

4

area

real

—

Surface or cross-sectional measure, in squared model length units.

5

node1

integer

0

Grid point to which this entry applies. Entry 1.

6

node2

integer

0

Grid point to which this entry applies. Entry 2.

7

node3

integer

0

Grid point to which this entry applies. Entry 3.

8

node4

integer

0

Grid point to which this entry applies. Entry 4.

9

node5

integer

0

Grid point to which this entry applies. Entry 5.

10

node6

integer

0

Grid point to which this entry applies. Entry 6.

11

node7

integer

0

Grid point to which this entry applies. Entry 7.

12

node8

integer

0

Grid point to which this entry applies. Entry 8.

Accepted words: AreaQuad4, AreaQuad8, AreaTria3, AreaTria6, Line, Point, ReversedNormal.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the load set ID must be a positive integer.

  • node — a grid point ID cannot be negative.

Example record

HeatFluxNodeSetLoad;1;AreaQuad4;0.2;;203;207;206;202

Model containing this record

Reading the example gives id = 1, faceKind = AreaQuad4, heatFlux = 0.2, node1 = 203.

HeatFluxSurfaceLoad1

A uniform heat flux into surface elements.

Record format and fields

HeatFluxSurfaceLoad1;id;heatFlux;<elements>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

heatFlux

real

Required

Thermal energy crossing unit area per unit time.

Repeated group elements. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

elemId

any

—

Identifier of the element addressed by this record.

Accepted words: By, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the load set ID must be a positive integer.

Example record

HeatFluxSurfaceLoad1;1;0.01;751;752;851;951;1051

Model containing this record

Reading the example gives id = 1, heatFlux = 0.01.

HeatFluxVectorLoad

The thermal vector flux from a distant source into the faces of surface elements.

Record format and fields

HeatFluxVectorLoad;id;heatFlux;sourceTemperature;directionFrameId;direction1;tableId1;direction2;tableId2;direction3;tableId3;controlNode;<elements>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

heatFlux

real

—

Thermal energy crossing unit area per unit time.

3

sourceTemperature

real

—

Source temperature (temperature).

4

directionFrameId

integer

—

Identifier addressing coordinate data.

5

direction1

real

0.0

Orientation in which the specified quantity acts or is measured. Entry 1. Alternative to tableId1.

6

tableId1

integer

—

Identifier of the tabulated function to evaluate. Entry 1. Alternative to direction1.

7

direction2

real

0.0

Orientation in which the specified quantity acts or is measured. Entry 2. Alternative to tableId2.

8

tableId2

integer

—

Identifier of the tabulated function to evaluate. Entry 2. Alternative to direction2.

9

direction3

real

0.0

Orientation in which the specified quantity acts or is measured. Entry 3. Alternative to tableId3.

10

tableId3

integer

—

Identifier of the tabulated function to evaluate. Entry 3. Alternative to direction3.

11

controlNode

integer

0

Identifier of the grid point through which this definition is controlled.

Repeated group elements. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

elemId

any

—

Identifier of the element addressed by this record.

Accepted words: By, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the load set ID must be a positive integer.

  • direction — a component is a real or a table, not both.

Example record

HeatFluxVectorLoad;1;1.361;5500.;;-1.;;0.;;0.;;;142

Model containing this record

Reading the example gives id = 1, heatFlux = 1.361, sourceTemperature = 5500., direction1 = -1..

HeatIsoMat

The heat transfer material of a conduction element, and the fluid of a forced convection (ForcedConvection).

Record format and fields

HeatIsoMat;id;conductivity;specificHeat;density;convectionCoefficient;viscosity;heatGenerationFactor;referenceEnthalpy;phaseChangeTemperature;phaseChangeRange;latentHeat

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the thermal material namespace.

2

conductivity

real

—

Thermal conductivity.

3

specificHeat

real

0.0

Energy per unit mass required for one unit of temperature change.

4

density

real

1.0

Mass per unit volume for a volumetric material or fluid density.

5

convectionCoefficient

real

—

Coefficient in the relation for convection.

6

viscosity

real

—

Viscous response coefficient in the selected constitutive or flow law.

7

heatGenerationFactor

real

1.0

Multiplier for heat generation.

8

referenceEnthalpy

real

—

Enthalpy assigned to the reference thermodynamic state.

9

phaseChangeTemperature

real

—

Phase change temperature (temperature).

10

phaseChangeRange

real

—

Temperature range of the phase change.

11

latentHeat

real

—

Latent heat of fusion.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the material ID must be a positive integer.

Example record

HeatIsoMat;1;0.2;9.E+8;2.7E-9;1.E-5

Model containing this record

Reading the example gives id = 1, conductivity = 0.2, specificHeat = 9.E+8, density = 2.7E-9.

HeatSurfaceDefaults

The default values of the HeatSurfaceProperty, HeatSurfaceNodes and HeatSurfaceSide surface elements.

Record format and fields

HeatSurfaceDefaults;kind;frontViewId;backViewId;frontRadiationPropId;backRadiationPropId;propId;orientationNode;directionFrameId;direction1;direction2;direction3

Position

Field

Type

Default

Meaning and conventions

1

kind

text

—

Selects the kind for HeatSurfaceDefaults.

2

frontViewId

integer

0

Identifier selecting the front view record or set.

3

backViewId

integer

0

Identifier selecting the back view record or set.

4

frontRadiationPropId

integer

0

Identifier selecting the front radiation property record or set.

5

backRadiationPropId

integer

0

Identifier selecting the back radiation property record or set.

6

propId

integer

0

Identifier of the property from which the element obtains its section or constitutive data.

7

orientationNode

integer

0

Grid point defining the orientation direction in place of explicit vector components.

8

directionFrameId

integer

0

Identifier selecting the direction frame record or set.

9

direction1

real

—

Orientation in which the specified quantity acts or is measured. Entry 1.

10

direction2

real

—

Orientation in which the specified quantity acts or is measured. Entry 2.

11

direction3

real

—

Orientation in which the specified quantity acts or is measured. Entry 3.

Accepted words: AreaQuad4, AreaQuad8, AreaTria3, AreaTria6, Constant, Element, EllipticCylinder, ForcedConvectionTube, Line, Point, ReversedNormal, Table, Tube.

Example record

HeatSurfaceDefaults;AreaQuad4;;;1;1

Model containing this record

Reading the example gives kind = AreaQuad4, frontRadiationPropId = 1, backRadiationPropId = 1.

HeatSurfaceNodes

A boundary condition surface element defined by its grid points.

Record format and fields

HeatSurfaceNodes;id;kind;frontViewId;backViewId;frontRadiationPropId;backRadiationPropId;node1;node2;node3;node4;node5;node6;node7;node8

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the surface element namespace.

2

kind

text

—

Selects the kind for HeatSurfaceNodes.

3

frontViewId

integer

0

Identifier addressing view factor face factor data.

4

backViewId

integer

0

Identifier addressing view factor face factor data.

5

frontRadiationPropId

integer

0

Identifier addressing radiation material data.

6

backRadiationPropId

integer

0

Identifier addressing radiation material data.

7

node1

integer

0

Grid point to which this entry applies. Entry 1.

8

node2

integer

0

Grid point to which this entry applies. Entry 2.

9

node3

integer

0

Grid point to which this entry applies. Entry 3.

10

node4

integer

0

Grid point to which this entry applies. Entry 4.

11

node5

integer

0

Grid point to which this entry applies. Entry 5.

12

node6

integer

0

Grid point to which this entry applies. Entry 6.

13

node7

integer

0

Grid point to which this entry applies. Entry 7.

14

node8

integer

0

Grid point to which this entry applies. Entry 8.

Accepted words: AreaQuad4, AreaQuad8, AreaTria3, AreaTria6, ReversedNormal, ReversedNormal1.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • node — a grid point ID cannot be negative.

  • node — a grid point is repeated in the surface.

Example record

HeatSurfaceNodes;241;AreaQuad4;;;;;205;206;207;208

Model containing this record

Reading the example gives id = 241, kind = AreaQuad4, node1 = 205, node2 = 206.

HeatSurfaceProp

The property of a HeatSurfaceProperty surface element.

Record format and fields

HeatSurfaceProp;id;area;diameter1;diameter2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

area

real

—

Surface or cross-sectional measure, in squared model length units.

3

diameter1

real

—

Diameter 1 (length).

4

diameter2

real

—

Diameter 2 (length).

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the property ID must be a positive integer.

Example record

HeatSurfaceProp;21;;10.;10.

Model containing this record

Reading the example gives id = 21, diameter1 = 10., diameter2 = 10..

HeatSurfaceProperty

A boundary condition surface element defined by grid points and a HeatSurfaceProp property.

Record format and fields

HeatSurfaceProperty;id;propId;kind;frontViewId;backViewId;node1;node2;orientationNode;frontRadiationPropId;backRadiationPropId;midsideNode;directionFrameId;direction1;direction2;direction3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the surface element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

kind

text

—

Selects the kind for HeatSurfaceProperty.

4

frontViewId

integer

0

Identifier addressing view factor face factor data.

5

backViewId

integer

0

Identifier addressing view factor face factor data.

6

node1

integer

Required

Identifier addressing node data.

7

node2

integer

0

Identifier addressing node data.

8

orientationNode

integer

0

Grid point defining the orientation direction in place of explicit vector components.

9

frontRadiationPropId

integer

0

Identifier addressing radiation material data.

10

backRadiationPropId

integer

0

Identifier addressing radiation material data.

11

midsideNode

integer

0

Identifier addressing node data.

12

directionFrameId

integer

0

Identifier addressing coordinate data.

13

direction1

real

—

Orientation in which the specified quantity acts or is measured. Entry 1.

14

direction2

real

—

Orientation in which the specified quantity acts or is measured. Entry 2.

15

direction3

real

—

Orientation in which the specified quantity acts or is measured. Entry 3.

Accepted words: EllipticCylinder, ForcedConvectionTube, Line, Point, Tube.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the surface property ID must be a positive integer.

  • orientationNode — a grid point ID cannot be negative.

Example record

HeatSurfaceProperty;151;7;Point;;;102;;;;;;;1.;0.;0.

Model containing this record

Reading the example gives id = 151, propId = 7, kind = Point, node1 = 102.

HeatSurfaceSide

A boundary condition surface element that is one side of a heat conduction element.

Record format and fields

HeatSurfaceSide;id;conductionElemId;sideCode;frontViewId;backViewId;frontRadiationPropId;backRadiationPropId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the surface element namespace.

2

conductionElemId

integer

Required

Identifier addressing element data.

3

sideCode

integer

Required

Selects one side of the join, element or interface in the record’s local ordering.

4

frontViewId

integer

0

Identifier addressing view factor face factor data.

5

backViewId

integer

0

Identifier addressing view factor face factor data.

6

frontRadiationPropId

integer

0

Identifier addressing radiation material data.

7

backRadiationPropId

integer

0

Identifier addressing radiation material data.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • conductionElemId — the conduction element ID must be a positive integer.

Example record

HeatSurfaceSide;231;211;1;2;;2

Model containing this record

Reading the example gives id = 231, conductionElemId = 211, sideCode = 1, frontViewId = 2.

Referenced records in this example

HeatVolumeSourceLoad

Applies volumetric heat generation to a list of conduction elements.

Record format and fields

HeatVolumeSourceLoad;id;heatGeneration;controlNode;<elements>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

heatGeneration

real

Required

Heat produced by the specified source over its stated geometric measure.

3

controlNode

integer

0

Identifier of the grid point through which this definition is controlled.

Repeated group elements. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

elemId

any

—

Identifier of the element addressed by this record.

Accepted words: By, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the load set ID must be a positive integer.

Example record

HeatVolumeSourceLoad;1;0.002;;1101;1201;1301

Model containing this record

Reading the example gives id = 1, heatGeneration = 0.002.

RadiationBands

Planck’s second radiation constant and the wavelength breakpoints of the radiation exchange problems, for the RadiationProp entries that give an emissivity for each wave band.

Record format and fields

RadiationBands;bandCount;planckSecondConstant;<wavelengths>

Position

Field

Type

Default

Meaning and conventions

1

bandCount

integer

Required

Number of band entries.

2

planckSecondConstant

real

Required

Second radiation constant used in the wavelength-dependent thermal radiation law.

Repeated group wavelengths. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

bandWavelength

real

—

Wavelength associated with the selected radiation band.

Accepted words: Constant, Element, Table.

Example record

RadiationBands;3;14388.;2.;10.

Model containing this record

Reading the example gives bandCount = 3, planckSecondConstant = 14388..

RadiationCavity

The characteristics of one radiation enclosure (cavity).

Record format and fields

RadiationCavity;id;ambientElemId;shadowing;scaleFactor;viewFactorOutput;viewFactorMethod;subdivisionAreaRatio;componentCount;<pairSets>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

ambientElemId

integer

0

Identifier addressing surface element data.

3

shadowing

text

—

Selects visibility or shadow checks between radiating surfaces.

4

scaleFactor

real

0.0

Multiplier applied to the quantity specified by the entry.

5

viewFactorOutput

integer

—

Controls reporting of the radiative exchange factors between surfaces.

6

viewFactorMethod

text

—

Selects the view factor method for RadiationCavity.

7

subdivisionAreaRatio

real

0.1

Relative measure of subdivision area.

8

componentCount

integer

32

Number of component entries.

Repeated group pairSets. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

pairSetId

integer

—

Identifier addressing set data.

Accepted words: Contour, FiniteDifferenceMethod, No, Yes.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the cavity ID must be a positive integer.

Example record

RadiationCavity;1;;Yes;;2

Model containing this record

Reading the example gives id = 1, shadowing = Yes, viewFactorOutput = 2.

RadiationCavityList

The surface elements of a radiation enclosure.

Record format and fields

RadiationCavityList;cavityId;matrixKind;<elements>

Position

Field

Type

Default

Meaning and conventions

1

cavityId

integer

Required

Identifier selecting the cavity record or set.

2

matrixKind

integer

—

Selects the matrix kind for RadiationCavityList.

Repeated group elements. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

elemId

any

—

Identifier of the element addressed by this record.

Accepted words: By, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • cavityId — the cavity ID must be a positive integer.

Example record

RadiationCavityList;2;1;231;Through;236

Model containing this record

Reading the example gives cavityId = 2, matrixKind = 1.

RadiationCavitySet

The radiation cavities that take part in the enclosure radiation analysis.

Record format and fields

RadiationCavitySet;<cavities>

This part of the record has no fixed fields.

Repeated group cavities. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

cavityId

integer

—

Identifier addressing radiation cavity data.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • cavityId — the card needs at least one cavity.

  • cavityId — a cavity ID must be a positive integer.

Example record

RadiationCavitySet;1;2

Model containing this record

RadiationExchangeMatrix

One column of the radiation exchange matrix of a cavity.

Record format and fields

RadiationExchangeMatrix;cavityId;columnIndex;<exchangeFactors>

Position

Field

Type

Default

Meaning and conventions

1

cavityId

integer

Required

Identifier selecting the cavity record or set.

2

columnIndex

integer

Required

Column of the matrix to which the following terms belong.

Repeated group exchangeFactors. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

exchangeFactor

real

—

Multiplier for exchange.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • cavityId — the cavity ID must be a positive integer.

  • exchangeFactor — a column of the matrix needs at least one coefficient.

  • exchangeFactor — a radiation exchange coefficient cannot be negative.

Example record

RadiationExchangeMatrix;2;3;0.;1998.2;2000.4;2000.4

Model containing this record

Reading the example gives cavityId = 2, columnIndex = 3.

RadiationProp

Supplies radiative properties for the sides of heat-transfer surfaces.

Record format and fields

RadiationProp;id;absorptivity;<emissivities>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

absorptivity

real

—

Fraction of incident radiation absorbed at the surface.

Repeated group emissivities. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

emissivity

real

—

Ratio of emitted radiation to that of a black body at the same temperature.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the radiation material ID must be a positive integer.

  • emissivity — an emissivity cannot be negative.

Example record

RadiationProp;3;0.3;0.2;0.85

Model containing this record

Reading the example gives id = 3, absorptivity = 0.3.

RadiationPropTemperature

The tables that make the radiation properties of a RadiationProp depend on temperature.

Record format and fields

RadiationPropTemperature;id;absorptivityTableId;<emissivityTables>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

absorptivityTableId

integer

0

Identifier addressing material table data.

Repeated group emissivityTables. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

emissivityTableId

integer

—

Identifier addressing material table data.

Accepted words: Constant, Element, Table.

Example record

RadiationPropTemperature;1;21;21

Model containing this record

Reading the example gives id = 1, absorptivityTableId = 21.

Referenced records in this example

RadiationToSpace

The radiation to space from surface element faces.

Record format and fields

RadiationToSpace;ambientNode;ambientViewFactor;controlNode;<elements>

Position

Field

Type

Default

Meaning and conventions

1

ambientNode

integer

Required

Identifier addressing scalar or grid point data.

2

ambientViewFactor

real

Required

Multiplier for ambient view.

3

controlNode

integer

0

Identifier of the grid point through which this definition is controlled.

Repeated group elements. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

elemId

any

—

Identifier of the element addressed by this record.

Accepted words: By, Through.

Example record

RadiationToSpace;9001;1.;;141;142;241

Model containing this record

Reading the example gives ambientNode = 9001, ambientViewFactor = 1..

TemperatureBoundary

The temperature boundary conditions of a heat transfer analysis.

Record format and fields

TemperatureBoundary;id;kind;<temperatureGroups>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

kind

text

Static

Selects the kind for TemperatureBoundary.

Repeated group temperatureGroups. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

temperatureEntry

any

—

Reference to, or value of, the temperature data for this boundary condition.

Accepted words: By, Static, Through, Transient.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the temperature set ID must be a positive integer.

  • temperature — the card needs at least one temperature and grid point.

Example record

TemperatureBoundary;3;Static;50.;201;Through;204

Model containing this record

Reading the example gives id = 3, kind = Static.

TrimComponentCoupling

How a (3D, finite element) trim component, a layer of porous or elastic material of a car interior, is coupled to the structure and to the acoustic cavities, and which of its degrees of freedom are constrained.

Record format and fields

TrimComponentCoupling;id;gluedSetId;slidingSetId;openSetId;imperviousSetId;outOfCoreBlockCount;singlePrecisionFlag;airGapSetId;fixedTranslationXSetId;fixedTranslationYSetId;fixedTranslationZSetId;fixedRotationXSetId;fixedRotationYSetId;fixedRotationZSetId;fixedPressureSetId;regionId;structureCompressionRatio;cavityCompressionRatio

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

gluedSetId

integer

0

Identifier selecting the glued set record or set.

3

slidingSetId

integer

0

Identifier selecting the sliding set record or set.

4

openSetId

integer

0

Identifier selecting the open set record or set.

5

imperviousSetId

integer

0

Identifier selecting the impervious set record or set.

6

outOfCoreBlockCount

integer

1

Number of out of core block entries.

7

singlePrecisionFlag

integer

0

Selects the single precision flag for TrimComponentCoupling.

8

airGapSetId

integer

0

Identifier selecting the air gap set record or set.

9

fixedTranslationXSetId

integer

0

Identifier selecting the fixed translation x set record or set.

10

fixedTranslationYSetId

integer

0

Identifier selecting the fixed translation y set record or set.

11

fixedTranslationZSetId

integer

0

Identifier selecting the fixed translation z set record or set.

12

fixedRotationXSetId

integer

0

Identifier selecting the fixed rotation x set record or set.

13

fixedRotationYSetId

integer

0

Identifier selecting the fixed rotation y set record or set.

14

fixedRotationZSetId

integer

0

Identifier selecting the fixed rotation z set record or set.

15

fixedPressureSetId

integer

0

Identifier selecting the fixed pressure set record or set.

16

regionId

integer

0

Identifier of the region on which the definition acts.

17

structureCompressionRatio

real

—

Relative measure of structure compression.

18

cavityCompressionRatio

real

—

Relative measure of cavity compression.

Accepted words: Constant, Element, Table.

Example record

TrimComponentCoupling;1;1;;2

Model containing this record

Reading the example gives id = 1, gluedSetId = 1, openSetId = 2.

TrimComponentCoupling1D

How a 1D analytical trim component (a layered porous material, TrimLayeredComponent, that has no finite element mesh of its own) is coupled to the structure and to the cavities.

Record format and fields

TrimComponentCoupling1D;id;gluedSetId;slidingSetId;openSetId;imperviousSetId;regionId;methodName

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

gluedSetId

integer

0

Identifier selecting the glued set record or set.

3

slidingSetId

integer

0

Identifier selecting the sliding set record or set.

4

openSetId

integer

0

Identifier selecting the open set record or set.

5

imperviousSetId

integer

0

Identifier selecting the impervious set record or set.

6

regionId

integer

0

Identifier of the region on which the definition acts.

7

methodName

text

—

Text naming the method.

Accepted words: Constant, Element, OneDimensional, Table.

Example record

TrimComponentCoupling1D;2;1;;2;;0;OneDimensional

Model containing this record

Reading the example gives id = 2, gluedSetId = 1, openSetId = 2, regionId = 0.

TrimCouplingTolerances

The tolerances with which the interface coupling matrices of a trim component are computed when the meshes at the interface do not match.

Record format and fields

TrimCouplingTolerances;id;couplingKind;relativeTolerance;gapTolerance1;gapTolerance2;gapTolerance3;gapTolerance4;regionId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

couplingKind

text

—

Selects the coupling kind for TrimCouplingTolerances.

3

relativeTolerance

real

—

Permitted numerical deviation for relative.

4

gapTolerance1

real

—

Permitted numerical deviation for gap.

5

gapTolerance2

real

same as gapTolerance1

Permitted numerical deviation for gap.

6

gapTolerance3

real

same as gapTolerance2

Permitted numerical deviation for gap.

7

gapTolerance4

real

same as gapTolerance3

Permitted numerical deviation for gap.

8

regionId

integer

0

Identifier of the region on which the definition acts.

Accepted words: Constant, Element, Interface, SimplePerforation, SolidAirGap, SolidGlued, SolidOpen, SolidSlide, Table, TrimSurface.

Example record

TrimCouplingTolerances;2;Interface;0.1;1.

Model containing this record

Reading the example gives id = 2, couplingKind = Interface, relativeTolerance = 0.1, gapTolerance1 = 1..

TrimLayeredComponent

The layers of a 1D analytical trim component (a stack of porous or elastic materials with no mesh of its own), listed from the bottom one.

Record format and fields

TrimLayeredComponent;id;<layers>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

Repeated group layers. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

globalPlyId

integer

—

Identifier selecting the global ply record or set.

2

plyMatId

integer

—

Identifier selecting the ply material record or set.

3

plyThickness

real

—

Ply thickness (length).

4

plyScaleFactor

real

—

Multiplier for ply scale.

Accepted words: Constant, Element, Table.

Example record

TrimLayeredComponent;1;1;201;8.;1.;2;204;2.;0.

Model containing this record

Reading the example gives id = 1.

ViewFactorFace

The radiation cavity and the shadowing of a surface element face, for the view factor calculation.

Record format and fields

ViewFactorFace;id;cavityId;shading;betaSubdivisions;gammaSubdivisions;surfaceOffset

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

cavityId

integer

0

Identifier addressing radiation cavity data.

3

shading

text

—

Controls treatment of surface obstruction in the radiation calculation.

4

betaSubdivisions

integer

1

Number of integration subdivisions in the beta direction.

5

gammaSubdivisions

integer

1

Number of integration subdivisions in the gamma direction.

6

surfaceOffset

real

0.0

Signed distance between the reference surface and the represented surface.

Accepted words: Both, CanBeShaded, CanShade, None.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the view factor ID must be a positive integer.

Example record

ViewFactorFace;1;1;Both

Model containing this record

Reading the example gives id = 1, cavityId = 1, shading = Both.

ViewFactorIntegration

The parameters of the Gaussian integration method of view factor calculation for one radiation cavity.

Record format and fields

ViewFactorIntegration;cavityId;blockingIntegrationOrder;shadowingIntegrationOrder;contourIntegrationLevel;errorTolerance;zeroTolerance;warpTolerance;radiationCheck

Position

Field

Type

Default

Meaning and conventions

1

cavityId

integer

Required

Identifier selecting the cavity record or set.

2

blockingIntegrationOrder

integer

4

Order of numerical integration used when checking for blocking surfaces.

3

shadowingIntegrationOrder

integer

4

Integration order used for surface visibility calculations.

4

contourIntegrationLevel

integer

4

Refinement level used for integration along the surface contour.

5

errorTolerance

real

0.1

Permitted numerical deviation for error.

6

zeroTolerance

real

1.0e-10

Permitted numerical deviation for zero.

7

warpTolerance

real

0.01

Permitted numerical deviation for warp.

8

radiationCheck

integer

3

Selects consistency checks on the radiative surface calculations.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • cavityId — the cavity ID must be a positive integer.

Example record

ViewFactorIntegration;1;3;3;6;0.05;1.E-10;0.01;3

Model containing this record

Reading the example gives cavityId = 1, blockingIntegrationOrder = 3, shadowingIntegrationOrder = 3, contourIntegrationLevel = 6.