BoltConnection

Represents a bolt cut by tying pairs of grid points on opposite sides to a common control node. A force or prescribed motion at this node applies pretension.

Record format and fields

BoltConnection;id;controlNode;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

controlNode

integer

Required

Identifier of the grid point through which this definition is controlled.

Keyed sections in lists

Begin each section with its key, then write its fixed fields and any counted list.

Section Top

Repeated group topNodes. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

topNode

integer

—

Grid point defining the top side of the connection.

Section Bottom

Repeated group bottomNodes. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

bottomNode

integer

—

Grid point defining the bottom side of the connection.

Accepted words: Bottom, Top.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • topNodes — a grid point ID must be a positive integer.

  • bottomNodes — a grid point ID must be a positive integer.

Example record

BoltConnection;1;999;Top;4;305;307;306;308;Bottom;4;401;403;402;404

Model containing this record

Reading the example gives id = 1, controlNode = 999.

BoltPretension

Defines a bolt pretension section through a layer of elements. An axial force or displacement at the control node loads the section.

Record format and fields

BoltPretension;id;controlNode;form;directionX;directionY;directionZ;offset;idType;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

controlNode

integer

Required

Identifier of the grid point through which this definition is controlled.

3

form

integer

0

Selects the form for BoltPretension.

4

directionX

real

0.0

X component of the specified direction vector in its reference frame.

5

directionY

real

0.0

Y component of the specified direction vector in its reference frame.

6

directionZ

real

0.0

Z component of the specified direction vector in its reference frame.

7

offset

real

0.0

Shift from the reference location or value in the convention of this entry.

8

idType

text

List

Selects the ID type for BoltPretension.

Keyed sections in lists

Begin each section with its key, then write its fixed fields and any counted list.

Section Elems

Repeated group elements. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

element

integer

—

Identifier of the element selected in this group.

Section Nodes

Repeated group nodes. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

node

integer

—

Grid point to which this entry applies.

Accepted words: Elems, List, Nodes, Set, TypedListSet3.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • elements — an element ID must be a positive integer.

  • nodes — a grid point ID must be a positive integer.

  • elements — the bolt needs elements.

Example record

BoltPretension;1;1001;0;;;;0.;List;Elems;4;1;2;3;4

Model containing this record

Reading the example gives id = 1, controlNode = 1001, form = 0, offset = 0..

BrakeMotion

The motion direction of a body of a brake system, which a BrakeSystem names (MT1_ID, MT2_ID).

Record format and fields

BrakeMotion;id;velocity;form;cosineX;cosineY;cosineZ;xCoord;yCoord;zCoord

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

velocity

real

0.0

Rate of displacement in the specified direction (length per time).

3

form

text

—

Selects the form for BrakeMotion.

4

cosineX

real

0.0

Direction cosines.

5

cosineY

real

0.0

Direction cosine relative to axis Y.

6

cosineZ

real

0.0

Direction cosine relative to axis Z.

7

xCoord

real

0.0

X coordinate of the location in the specified frame.

8

yCoord

real

0.0

Y coordinate of the location in the specified frame.

9

zCoord

real

0.0

Z coordinate of the location in the specified frame.

Accepted words: Constant, Element, RotationMotion, Table, TranslationMotion.

Example record

BrakeMotion;42;1.E+3;TranslationMotion;0.;1.;0.

Model containing this record

Reading the example gives id = 42, velocity = 1.E+3, form = TranslationMotion, cosineX = 0..

BrakeProp

The property of a brake system for the brake squeal analysis, named by a BrakeSystem.

Record format and fields

BrakeProp;id;<parameters>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group parameters. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

number

—

Value assigned to the named parameter. Its interpretation depends on that name.

Accepted words: AverageStiffnessMethod, Constant, Element, Friction, Table, TemperatureAverageStiffness.

Example record

BrakeProp;1;AverageStiffnessMethod;1.E+5;Friction;0.3

Model containing this record

Reading the example gives id = 1.

BrakeSqueal

The data of a brake squeal analysis of one wheel, or of another rotating object in contact with friction between sets of bodies (unsymmetric friction stiffness matrices).

Record format and fields

BrakeSqueal;id;loadFactor;areaStiffness;squealOnly;axisX;axisY;axisZ;xCoord;yCoord;zCoord

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

loadFactor

real

0.0

Multiplier for load.

3

areaStiffness

real

Required

Contact stiffness normalized by the effective contact area.

4

squealOnly

text

—

Restricts the option to the brake-squeal analysis when selected.

5

axisX

real

—

X direction cosine of the axis of rotation.

6

axisY

real

—

Component Y of the specified axis vector.

7

axisZ

real

—

Component Z of the specified axis vector.

8

xCoord

real

—

X coordinate of the location in the specified frame.

9

yCoord

real

—

Y coordinate of the location in the specified frame.

10

zCoord

real

—

Z coordinate of the location in the specified frame.

Accepted words: Constant, Element, No, Table, Yes.

Example record

BrakeSqueal;100;0.5;1.E+5;No;0.;0.;1.;0.;0.;0.

Model containing this record

Reading the example gives id = 100, loadFactor = 0.5, areaStiffness = 1.E+5, squealOnly = No.

BrakeSystem

The data of a brake system for brake squeal calculations with one wheel or several, on one axis or several.

Record format and fields

BrakeSystem;id;loadFactor;frictionVectorMode;squealOnly;slidingContactOption;<disks>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

loadFactor

real

0.0

Multiplier for load.

3

frictionVectorMode

integer

0

Selects how the friction direction vector is defined or updated.

4

squealOnly

text

Yes

Restricts the option to the brake-squeal analysis when selected.

5

slidingContactOption

integer

0

Selects the sliding contact option for BrakeSystem.

Repeated group disks. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

diskName

text

—

Text naming the disk.

2

firstBodyId

integer

—

Identifier selecting the first body record or set.

3

secondBodyId

integer

—

Identifier selecting the second body record or set.

4

firstMotionId

integer

—

Identifier selecting the first motion record or set.

5

secondMotionId

integer

—

Identifier selecting the second motion record or set.

6

brakePropId

integer

—

Identifier selecting the brake property record or set.

Accepted words: Constant, Element, No, Table, Yes.

Example record

BrakeSystem;900;0.5;0;No;0;INNER;1;2;41;;51;OUTER;1;3;42;42;52

Model containing this record

Reading the example gives id = 900, loadFactor = 0.5, frictionVectorMode = 0, squealOnly = No.

ContactAutoParams

Specifies name–value settings for automatic contact generation.

Record format and fields

ContactAutoParams;id;<parameters>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

0

Identifier in the namespace of this card type.

Repeated group parameters. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

any

—

Value assigned to the named parameter. Its interpretation depends on that name.

Accepted words: BilinearCoulomb, Both, Full, GeneralGlue, No, NodeToSurface, Off, On, PermanentGlue, SegmentToSegment, StandardGlue, TouchOnly, Yes.

Accepted parameter names: BeamCapping, BeamContact, ContactKind, DetectionDistance, EdgeContact, ElemSet, FrictionCoefficient, FrictionKind, IgnoreThickness, InitialStressFree, ModelDimension, PropertySet, RigidBodySet, SeedElemSet, SeedNodeSet, SelfContact.

Example record

ContactAutoParams;0;ContactKind;TouchOnly;DetectionDistance;1.;BeamContact;Yes;FrictionCoefficient;0.1

Model containing this record

Reading the example gives id = 0.

ContactBeamCap

Whether a cap is added to a beam and how many segments model a rod or tube section, for the segment-to-segment beam contact.

Record format and fields

ContactBeamCap;id;capKind;segmentCount

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

capKind

integer

0

Selects the cap kind for ContactBeamCap.

3

segmentCount

integer

32

Number of segment entries.

Example record

ContactBeamCap;1;1;16

Model containing this record

Reading the example gives id = 1, capKind = 1, segmentCount = 16.

ContactBeamRadius

The equivalent radius of beams for the node-to-segment beam-to-beam contact: the radius of the beam elements or bodies it lists, or the default radius of all beam elements.

Record format and fields

ContactBeamRadius;radius;idKind;<ids>

Position

Field

Type

Default

Meaning and conventions

1

radius

real

Required

Radial dimension measured from the centre or axis (length).

2

idKind

text

ElemId

Selects the ID kind for ContactBeamRadius.

Repeated group ids. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

entityId

any

—

Identifier selecting the entity record or set.

Accepted words: All, Body, By, ElemId, Through.

Example record

ContactBeamRadius;2.5;ElemId;11;Through;14

Model containing this record

Reading the example gives radius = 2.5, idKind = ElemId.

ContactBeamSectionFlags

The branches and segments of a beam section that take part in the segment-to-segment beam contact.

Record format and fields

ContactBeamSectionFlags;id;branch1;segmentFlag1;branch2;segmentFlag2;branch3;segmentFlag3;<segments>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

branch1

integer

0

Identifies the branch of the selected beam section. Entry 1.

3

segmentFlag1

integer

0

Selects the segment flag 1 for ContactBeamSectionFlags.

4

branch2

integer

0

Identifies the branch of the selected beam section. Entry 2.

5

segmentFlag2

integer

0

Selects the segment flag 2 for ContactBeamSectionFlags.

6

branch3

integer

0

Identifies the branch of the selected beam section. Entry 3.

7

segmentFlag3

integer

0

Selects the segment flag 3 for ContactBeamSectionFlags.

Repeated group segments. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

branch

integer

—

Identifies the branch of the selected beam section.

2

segmentFlag

integer

—

Selects the segment flag for segments.

Example record

ContactBeamSectionFlags;1;0;1

Model containing this record

Reading the example gives id = 1, branch1 = 0, segmentFlag1 = 1.

ContactBezierSurface

A rigid contact body made of a Bezier surface.

Record format and fields

ContactBezierSurface;id;pointCount1;pointCount2;subdivisions1;subdivisions2;<nodes>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

pointCount1

integer

Required

Number of point entries.

3

pointCount2

integer

Required

Number of point entries.

4

subdivisions1

integer

Required

The subdivisions in the first direction.

5

subdivisions2

integer

Required

The subdivisions in the second direction.

Repeated group nodes. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

node

integer

—

Grid point to which this entry applies.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • node — a grid point ID must be a positive integer.

Example record

ContactBezierSurface;52;2;2;4;4;9002;9005;9003;9006

Model containing this record

Reading the example gives id = 52, pointCount1 = 2, pointCount2 = 2, subdivisions1 = 4.

ContactBody

A flexible or rigid contact body in 2D or 3D.

Record format and fields

Forms: noMotionLine, motionLine.

ContactBody: noMotionLine

Form noMotionLine, when lines is a word.

ContactBody;id;dimension;behavior;surfaceId;contactKind;friction;splineSegmentsId;control;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

dimension

text

ThreeDimensional

Spatial dimension or section dimension according to the selected entry.

3

behavior

text

Deformable

Selects the assumed response of the body or contact formulation.

4

surfaceId

integer

0

Identifier selecting the surface record or set.

5

contactKind

integer

0

Selects the contact kind for ContactBody.

6

friction

number

0.0

Controls tangential resistance to relative motion at the interface.

7

splineSegmentsId

integer

0

Identifier selecting the spline segments record or set.

8

control

integer

0

-1 position control, 0 velocity control, a grid point number for load control.

Keyed sections in lines

Begin each section with its key, then write its fixed fields and any counted list.

Section Advance

Position

Field

Type

Default

Meaning and conventions

1

smoothingAngle

real

—

Angle limit used when smoothing adjacent surface segments.

2

contactOption

integer

—

Selects the contact option for advance.

3

midsideProjection

integer

—

> 0: the mid-side grid points are projected onto the splines.

Section Rigid

Position

Field

Type

Default

Meaning and conventions

1

referenceNode

integer

—

Identifier of the grid point serving as the reference for this definition.

2

entityCount

integer

—

Number of entity entries.

3

rigidBodyName

text

—

Text naming the rigid body. Written as one text field.

Section ApproachVelocity

Position

Field

Type

Default

Meaning and conventions

1

approachAngularVelocity

real

—

Approach angular velocity (length per time).

2

approachAxis1

real

—

Component 1 of the direction of approach or rigid motion.

3

approachAxis2

real

—

Component 2 of the direction of approach or rigid motion.

4

approachAxis3

real

—

Component 3 of the direction of approach or rigid motion.

5

approachVelocity1

real

—

Approach velocity 1 (length per time).

6

approachVelocity2

real

—

Approach velocity 2 (length per time).

7

approachVelocity3

real

—

Approach velocity 3 (length per time).

Section Growth

Position

Field

Type

Default

Meaning and conventions

1

growthFactor1

real

—

Multiplier for growth.

2

growthFactor2

real

—

Multiplier for growth.

3

growthFactor3

real

—

Multiplier for growth.

4

growthTable1

integer

—

Identifier of the table used at position 1 in the crack-growth relation.

5

growthTable2

integer

—

Identifier of the table used at position 2 in the crack-growth relation.

6

growthTable3

integer

—

Identifier of the table used at position 3 in the crack-growth relation.

Section HeatTransfer

Position

Field

Type

Default

Meaning and conventions

1

environmentFilmCoefficient

number

—

Coefficient in the relation for environment film.

2

sinkTemperature

number

—

Sink temperature (temperature).

3

contactHeatTransferCoefficient

number

—

Coefficient in the relation for contact heat transfer.

4

bodyTemperature

number

—

Body temperature (temperature).

5

nearContactConvectionCoefficient

number

—

Coefficient in the relation for near contact convection.

6

nearContactNaturalConvectionCoefficient

number

—

Coefficient in the relation for near contact natural convection.

7

thermalInterfaceKind

integer

—

Selects the thermal interface kind for heat.

8

nearContactNaturalConvectionExponent

number

—

Power in the law for near contact natural convection.

9

emissivity

number

—

Ratio of emitted radiation to that of a black body at the same temperature.

10

distanceDependentConvectionCoefficient

number

—

Coefficient in the relation for distance dependent convection.

11

nearContactNonlinearConvectionCoefficient

number

—

Coefficient in the relation for near contact nonlinear convection.

12

nearContactNonlinearConvectionExponent

number

—

Power in the law for near contact nonlinear convection.

13

environmentNonlinearConvectionCoefficient

number

—

Coefficient in the relation for environment nonlinear convection.

14

environmentNonlinearConvectionExponent

number

—

Power in the law for environment nonlinear convection.

15

environmentNaturalConvectionCoefficient

number

—

Coefficient in the relation for environment natural convection.

16

environmentNaturalConvectionExponent

number

—

Power in the law for environment natural convection.

17

additionalHeatCoefficient1

real

—

Coefficient in the relation for additional heat.

18

additionalHeatCoefficient2

real

—

Coefficient in the relation for additional heat.

Section PatchSurface

Position

Field

Type

Default

Meaning and conventions

1

patchCount

integer

—

Number of patch entries.

Repeated group patches. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

patchId

integer

—

Identifier selecting the patch record or set.

2

patchNode1

integer

—

Grid point at position 1 in the surface patch connectivity.

3

patchNode2

integer

—

Grid point at position 2 in the surface patch connectivity.

4

patchNode3

integer

—

Grid point at position 3 in the surface patch connectivity.

5

patchNode4

integer

—

Grid point at position 4 in the surface patch connectivity.

Section BezierSurface

Position

Field

Type

Default

Meaning and conventions

1

pointCount1

integer

—

Number of point entries.

2

pointCount2

integer

—

Number of point entries.

3

subdivisions1

integer

—

The subdivisions in the first direction.

4

subdivisions2

integer

—

The subdivisions in the second direction.

Repeated group controlPoints. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

controlPoint

integer

—

Point defining the geometry or motion of the associated contact surface.

Section NurbsCurve

Repeated group curveData. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

curveDataValue

number

—

Numeric data at the current position in the curve description.

Section NurbsSurface

Repeated group surfaceData. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

surfaceDataValue

number

—

Numeric data at the current position of the surface description.

ContactBody: motionLine

Form motionLine, for every other record.

ContactBody;id;dimension;behavior;surfaceId;contactKind;friction;splineSegmentsId;control;loadNode;angularVelocity;axisCosine1;axisCosine2;axisCosine3;rigidVelocity1;rigidVelocity2;rigidVelocity3;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

dimension

text

ThreeDimensional

Spatial dimension or section dimension according to the selected entry.

3

behavior

text

Deformable

Selects the assumed response of the body or contact formulation.

4

surfaceId

integer

0

Identifier selecting the surface record or set.

5

contactKind

integer

0

Selects the contact kind for ContactBody.

6

friction

number

0.0

Controls tangential resistance to relative motion at the interface.

7

splineSegmentsId

integer

0

Identifier selecting the spline segments record or set.

8

control

integer

0

-1 position control, 0 velocity control, a grid point number for load control.

9

loadNode

integer

0

Grid point at which the selected load or control quantity is evaluated.

10

angularVelocity

number

—

Angular velocity (length per time).

11

axisCosine1

number

—

Direction cosine for axis component 1 (dimensionless).

12

axisCosine2

number

—

Direction cosine for axis component 2 (dimensionless).

13

axisCosine3

number

—

Direction cosine for axis component 3 (dimensionless).

14

rigidVelocity1

number

—

Rigid velocity 1 (length per time).

15

rigidVelocity2

number

—

Rigid velocity 2 (length per time).

16

rigidVelocity3

number

—

Rigid velocity 3 (length per time).

Keyed sections in lines

Begin each section with its key, then write its fixed fields and any counted list.

Section Advance

Position

Field

Type

Default

Meaning and conventions

1

smoothingAngle

real

—

Angle limit used when smoothing adjacent surface segments.

2

contactOption

integer

—

Selects the contact option for advance.

3

midsideProjection

integer

—

> 0: the mid-side grid points are projected onto the splines.

Section Rigid

Position

Field

Type

Default

Meaning and conventions

1

referenceNode

integer

—

Identifier of the grid point serving as the reference for this definition.

2

entityCount

integer

—

Number of entity entries.

3

rigidBodyName

text

—

Text naming the rigid body. Written as one text field.

Section ApproachVelocity

Position

Field

Type

Default

Meaning and conventions

1

approachAngularVelocity

real

—

Approach angular velocity (length per time).

2

approachAxis1

real

—

Component 1 of the direction of approach or rigid motion.

3

approachAxis2

real

—

Component 2 of the direction of approach or rigid motion.

4

approachAxis3

real

—

Component 3 of the direction of approach or rigid motion.

5

approachVelocity1

real

—

Approach velocity 1 (length per time).

6

approachVelocity2

real

—

Approach velocity 2 (length per time).

7

approachVelocity3

real

—

Approach velocity 3 (length per time).

Section Growth

Position

Field

Type

Default

Meaning and conventions

1

growthFactor1

real

—

Multiplier for growth.

2

growthFactor2

real

—

Multiplier for growth.

3

growthFactor3

real

—

Multiplier for growth.

4

growthTable1

integer

—

Identifier of the table used at position 1 in the crack-growth relation.

5

growthTable2

integer

—

Identifier of the table used at position 2 in the crack-growth relation.

6

growthTable3

integer

—

Identifier of the table used at position 3 in the crack-growth relation.

Section HeatTransfer

Position

Field

Type

Default

Meaning and conventions

1

environmentFilmCoefficient

number

—

Coefficient in the relation for environment film.

2

sinkTemperature

number

—

Sink temperature (temperature).

3

contactHeatTransferCoefficient

number

—

Coefficient in the relation for contact heat transfer.

4

bodyTemperature

number

—

Body temperature (temperature).

5

nearContactConvectionCoefficient

number

—

Coefficient in the relation for near contact convection.

6

nearContactNaturalConvectionCoefficient

number

—

Coefficient in the relation for near contact natural convection.

7

thermalInterfaceKind

integer

—

Selects the thermal interface kind for heat.

8

nearContactNaturalConvectionExponent

number

—

Power in the law for near contact natural convection.

9

emissivity

number

—

Ratio of emitted radiation to that of a black body at the same temperature.

10

distanceDependentConvectionCoefficient

number

—

Coefficient in the relation for distance dependent convection.

11

nearContactNonlinearConvectionCoefficient

number

—

Coefficient in the relation for near contact nonlinear convection.

12

nearContactNonlinearConvectionExponent

number

—

Power in the law for near contact nonlinear convection.

13

environmentNonlinearConvectionCoefficient

number

—

Coefficient in the relation for environment nonlinear convection.

14

environmentNonlinearConvectionExponent

number

—

Power in the law for environment nonlinear convection.

15

environmentNaturalConvectionCoefficient

number

—

Coefficient in the relation for environment natural convection.

16

environmentNaturalConvectionExponent

number

—

Power in the law for environment natural convection.

17

additionalHeatCoefficient1

real

—

Coefficient in the relation for additional heat.

18

additionalHeatCoefficient2

real

—

Coefficient in the relation for additional heat.

Section PatchSurface

Position

Field

Type

Default

Meaning and conventions

1

patchCount

integer

—

Number of patch entries.

Repeated group patches. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

patchId

integer

—

Identifier selecting the patch record or set.

2

patchNode1

integer

—

Grid point at position 1 in the surface patch connectivity.

3

patchNode2

integer

—

Grid point at position 2 in the surface patch connectivity.

4

patchNode3

integer

—

Grid point at position 3 in the surface patch connectivity.

5

patchNode4

integer

—

Grid point at position 4 in the surface patch connectivity.

Section BezierSurface

Position

Field

Type

Default

Meaning and conventions

1

pointCount1

integer

—

Number of point entries.

2

pointCount2

integer

—

Number of point entries.

3

subdivisions1

integer

—

The subdivisions in the first direction.

4

subdivisions2

integer

—

The subdivisions in the second direction.

Repeated group controlPoints. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

controlPoint

integer

—

Point defining the geometry or motion of the associated contact surface.

Section NurbsCurve

Repeated group curveData. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

curveDataValue

number

—

Numeric data at the current position in the curve description.

Section NurbsSurface

Repeated group surfaceData. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

surfaceDataValue

number

—

Numeric data at the current position of the surface description.

Accepted words: Advance, ApproachVelocity, BezierSurface, Deformable, Growth, HeatTransfer, NurbsCurve, NurbsSurface, PatchSurface, Rigid, Symmetric, ThreeDimensional, TwoDimensional.

Accepted parameter names: AdditionalHeatCoefficient1, AdditionalHeatCoefficient2, BodyTemperature, ContactHeatTransferCoefficient, DistanceDependentConvectionCoefficient, Emissivity, EnvironmentFilmCoefficient, EnvironmentNaturalConvectionCoefficient, EnvironmentNaturalConvectionExponent, EnvironmentNonlinearConvectionCoefficient, EnvironmentNonlinearConvectionExponent, NearContactConvectionCoefficient, NearContactNaturalConvectionCoefficient, NearContactNaturalConvectionExponent, NearContactNonlinearConvectionCoefficient, NearContactNonlinearConvectionExponent, SinkTemperature, ThermalInterfaceKind.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • rigid — the rigid body name has no comma, $ or tab.

  • rigid — the rigid body name does not begin or end with a blank.

  • patches — PATCH3D needs at least one patch.

  • patches — a grid point ID must be a positive integer.

  • bezier — a grid point ID must be a positive integer.

Example record

ContactBody;1;ThreeDimensional;Deformable;1

Model containing this record

ContactBody1

A flexible or rigid contact body, the new form of ContactBody.

Record format and fields

ContactBody1;id;bodyParamsId;dimension;behavior;surfaceId;rigidMotionId;forceReferencePoint

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

bodyParamsId

integer

0

Identifier selecting the body params record or set.

3

dimension

text

—

Spatial dimension or section dimension according to the selected entry.

4

behavior

text

—

Selects the assumed response of the body or contact formulation.

5

surfaceId

integer

0

Identifier selecting the surface record or set.

6

rigidMotionId

integer

0

Identifier selecting the rigid motion record or set.

7

forceReferencePoint

integer

0

The reference point of the resultant contact force: -1 origin, 0 centroid of the body.

Accepted words: Deformable, HeatTransfer, Rigid, Symmetric, ThreeDimensional, TwoDimensional.

Example record

ContactBody1;2;;TwoDimensional;Rigid;70;20

Model containing this record

Reading the example gives id = 2, dimension = TwoDimensional, behavior = Rigid, surfaceId = 70.

ContactBodyChange

Changes the definition of the deformable contact bodies in a load case.

Record format and fields

ContactBodyChange;id;kind;<ranges>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

kind

text

—

Selects the kind for ContactBodyChange.

Repeated group ranges. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

bodyId

integer

—

Identifier addressing contact body data.

2

firstNode

integer

—

Identifier addressing node in range data.

3

lastNode

integer

—

Final grid point of the ordered segment or selection.

4

increment

integer

—

Change applied in one continuation or loading step.

Accepted words: Exclude, Node.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • bodyId — the card needs at least one body.

  • bodyId — a body ID must be a positive integer.

Example record

ContactBodyChange;1;Node;1;19;27;1;1;3;27;3

Model containing this record

Reading the example gives id = 1, kind = Node.

ContactBodyMove

The movement of bodies in contact in a load case: the rigid bodies are moved until they touch the deformable ones, or the contact of some bodies is released.

Record format and fields

ContactBodyMove;id;moveKind;<bodies>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

moveKind

text

Approach

Selects the move kind for ContactBodyMove.

Repeated group bodies. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

bodyId

integer

—

Identifier selecting the body record or set.

Accepted words: Approach, Release, Synchronous.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • bodies — a body ID must be a positive integer.

Example record

ContactBodyMove;2;Release;2

Model containing this record

Reading the example gives id = 2, moveKind = Release.

ContactBodyParams

The parameters of a contact body: friction, spline smoothing of the surface, check of the contact conditions, heat transfer coefficients, as (name, value) pairs.

Record format and fields

ContactBodyParams;id;<parameters>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group parameters. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

any

—

Value assigned to the named parameter. Its interpretation depends on that name.

Accepted words: BilinearCoulomb, Both, Full, GeneralGlue, No, NodeToSurface, Off, On, PermanentGlue, SegmentToSegment, StandardGlue, TouchOnly, Yes.

Accepted parameter names: AdditionalHeatCoefficient1, AdditionalHeatCoefficient2, BodyContactOptions, BodyTemperature, ContactHeatTransferCoefficient, DisplacementOption, DistanceDependentConvectionCoefficient, Emissivity, EnvironmentFilmCoefficient, EnvironmentNaturalConvectionCoefficient, EnvironmentNaturalConvectionExponent, EnvironmentNonlinearConvectionCoefficient, EnvironmentNonlinearConvectionExponent, FrictionCoefficient, InterfaceSubtype, MidsideNodes, NearContactConvectionCoefficient, NearContactNaturalConvectionCoefficient, NearContactNaturalConvectionExponent, NearContactNonlinearConvectionCoefficient, NearContactNonlinearConvectionExponent, SeparationAngle, SinkTemperature, ThermalInterfaceKind.

Example record

ContactBodyParams;5;FrictionCoefficient;0.1;InterfaceSubtype;0

Model containing this record

Reading the example gives id = 5.

ContactBoxRegion

Selects elements inside a three-dimensional box as a region of a contact body.

Record format and fields

ContactBoxRegion;id;inclusionRule;coordinateForm;cornerNode1;cornerNode2;cornerX1;cornerNode3;cornerY1;cornerNode4;cornerZ1;cornerNode5;cornerX2;cornerNode6;cornerY2;cornerNode7;cornerZ2;cornerNode8;cornerX3;cornerY3;cornerZ3;cornerX4;cornerY4;cornerZ4;cornerX5;cornerY5;cornerZ5;cornerX6;cornerY6;cornerZ6;cornerX7;cornerY7;cornerZ7;cornerX8;cornerY8;cornerZ8

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

inclusionRule

integer

0

Criterion for including candidate entities in the region. Alternative to coordinateForm.

3

coordinateForm

text

—

Selects the coordinate representation of the defined surface or motion. Alternative to inclusionRule.

4

cornerNode1

any

—

Grid point defining corner 1 of the selected geometry.

5

cornerNode2

integer

—

Grid point defining corner 2 of the selected geometry. Alternative to cornerX1.

6

cornerX1

real

—

Coordinate X of corner 1 in the local frame. Alternative to cornerNode2.

7

cornerNode3

integer

—

Grid point defining corner 3 of the selected geometry. Alternative to cornerY1.

8

cornerY1

real

—

Coordinate Y of corner 1 in the local frame. Alternative to cornerNode3.

9

cornerNode4

integer

—

Grid point defining corner 4 of the selected geometry. Alternative to cornerZ1.

10

cornerZ1

real

—

Coordinate Z of corner 1 in the local frame. Alternative to cornerNode4.

11

cornerNode5

integer

—

Grid point defining corner 5 of the selected geometry. Alternative to cornerX2.

12

cornerX2

real

—

Coordinate X of corner 2 in the local frame. Alternative to cornerNode5.

13

cornerNode6

integer

—

Grid point defining corner 6 of the selected geometry. Alternative to cornerY2.

14

cornerY2

real

—

Coordinate Y of corner 2 in the local frame. Alternative to cornerNode6.

15

cornerNode7

integer

—

Grid point defining corner 7 of the selected geometry. Alternative to cornerZ2.

16

cornerZ2

real

—

Coordinate Z of corner 2 in the local frame. Alternative to cornerNode7.

17

cornerNode8

integer

—

Grid point defining corner 8 of the selected geometry. Alternative to cornerX3.

18

cornerX3

real

—

Coordinate X of corner 3 in the local frame. Alternative to cornerNode8.

19

cornerY3

real

—

Coordinate Y of corner 3 in the local frame.

20

cornerZ3

real

—

Coordinate Z of corner 3 in the local frame.

21

cornerX4

real

—

Coordinate X of corner 4 in the local frame.

22

cornerY4

real

—

Coordinate Y of corner 4 in the local frame.

23

cornerZ4

real

—

Coordinate Z of corner 4 in the local frame.

24

cornerX5

real

—

Coordinate X of corner 5 in the local frame.

25

cornerY5

real

—

Coordinate Y of corner 5 in the local frame.

26

cornerZ5

real

—

Coordinate Z of corner 5 in the local frame.

27

cornerX6

real

—

Coordinate X of corner 6 in the local frame.

28

cornerY6

real

—

Coordinate Y of corner 6 in the local frame.

29

cornerZ6

real

—

Coordinate Z of corner 6 in the local frame.

30

cornerX7

real

—

Coordinate X of corner 7 in the local frame.

31

cornerY7

real

—

Coordinate Y of corner 7 in the local frame.

32

cornerZ7

real

—

Coordinate Z of corner 7 in the local frame.

33

cornerX8

real

—

Coordinate X of corner 8 in the local frame.

34

cornerY8

real

—

Coordinate Y of corner 8 in the local frame.

35

cornerZ8

real

—

Coordinate Z of corner 8 in the local frame.

Accepted words: Coordinates.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • cornerX1 — the coordinates of the box must be finite.

Example record

ContactBoxRegion;32;;Coordinates;0;;0.;;0.;;0.;;400.;;0.;;0.;;400.;100.;0.;0.;100.;0.;0.;0.;50.;400.;0.;50.;400.;100.;50.;0.;100.;50.

Model containing this record

Reading the example gives id = 32, coordinateForm = Coordinates, cornerNode1 = 0, cornerX1 = 0..

ContactControlParams

The control parameters of the contact algorithm of the contact set that has the same number, as (name, value) pairs.

Record format and fields

ContactControlParams;contactSetId;parameterName1;parameterValue1;parameterName2;parameterValue2;parameterName3;parameterValue3;<parameters>

Position

Field

Type

Default

Meaning and conventions

1

contactSetId

integer

Required

Identifier selecting the contact set record or set.

2

parameterName1

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list. Entry 1.

3

parameterValue1

any

—

Value assigned to the named parameter. Its interpretation depends on that name. Entry 1.

4

parameterName2

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list. Entry 2.

5

parameterValue2

any

—

Value assigned to the named parameter. Its interpretation depends on that name. Entry 2.

6

parameterName3

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list. Entry 3.

7

parameterValue3

any

—

Value assigned to the named parameter. Its interpretation depends on that name. Entry 3.

Repeated group parameters. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

any

—

Value assigned to the named parameter. Its interpretation depends on that name.

Accepted words: Both, Constant, Element, Full, No, Off, On, Table, Yes.

Accepted parameter names: ContactTolerance, NormalPenalty, ShellThicknessOption, TangentPenalty.

Example record

ContactControlParams;200;PENTYP;1;INIPENE;0

Model containing this record

Reading the example gives contactSetId = 200, parameterName1 = PENTYP, parameterValue1 = 1, parameterName2 = INIPENE.

ContactElemSurface

Defines the elements forming a contact surface for a contact body.

Record format and fields

ContactElemSurface;id;<elements>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group elements. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

element

any

—

Identifier of the element selected in this group.

Accepted words: By, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • elements — the surface needs at least one element.

Example record

ContactElemSurface;1;1;2;3;4

Model containing this record

Reading the example gives id = 1.

ContactEllipsoidList

Groups the named contact ellipsoids of an occupant model.

Record format and fields

ContactEllipsoidList;id;<ellipsoidNames>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group ellipsoidNames. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

ellipsoidName

text

—

Text naming the ellipsoid.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • ellipsoidNames — the list needs at least one ellipsoid name.

  • ellipsoidNames — an ellipsoid name is a word with no blank, comma or $.

Example record

ContactEllipsoidList;2;HEAD;CHEST

Model containing this record

Reading the example gives id = 2.

ContactFaceRegion

A contact region made of element faces, named by ContactPair.

Record format and fields

ContactFaceRegion;id;bodyParamsId;dimension;form;includeThickness;edgeContact;<faces>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

bodyParamsId

integer

0

Identifier selecting the body params record or set.

3

dimension

text

ThreeDimensional

Spatial dimension or section dimension according to the selected entry.

4

form

text

Face

Selects the form for ContactFaceRegion.

5

includeThickness

text

Yes

Selects whether the surface search includes the physical thickness.

6

edgeContact

integer

1

1 beam and bar edges, 10 free and hard shell edges, 11 both.

Repeated group faces. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

faceElemId

integer

—

Identifier selecting the face element record or set.

2

faceId

any

—

Identifier selecting the face record or set.

3

idType

any

—

Selects the ID type for faces.

4

node

integer

—

Grid point to which this entry applies.

Accepted words: Both, Bottom, Elements, EndA, EndB, Face, No, Node, Rigid, Set, ThreeDimensional, Top, TwoDimensional, Yes.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • faces — the surface needs at least one face.

  • faces — an element or set ID must be a positive integer.

  • elemId — the surface needs at least one face.

  • elemId — an element ID must be a positive integer.

  • elemId — a grid point ID must not be negative.

  • elemId — the two corners of an edge of a 2D body are both given (the third blank) or both blank.

  • elemId — the three corners of a face are all given or all blank.

Example record

ContactFaceRegion;5;;TwoDimensional;Node;;;7;14;13;;8;15;14

Model containing this record

Reading the example gives id = 5, dimension = TwoDimensional, form = Node.

ContactMaterialRegion

Selects elements by material to form a three-dimensional contact region.

Record format and fields

ContactMaterialRegion;id;<materials>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group materials. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

matId

integer

—

Material identifier used to retrieve the constitutive data.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • matIds — the region needs at least one material.

  • matIds — a material ID must be a positive integer.

Example record

ContactMaterialRegion;11;2

Model containing this record

Reading the example gives id = 11.

ContactNodeRegion

A contact region made of a list of grid points.

Record format and fields

ContactNodeRegion;id;bodyParamsId;dimension;<nodes>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

bodyParamsId

integer

0

Identifier selecting the body params record or set.

3

dimension

any

ThreeDimensional

Spatial dimension or section dimension according to the selected entry.

Repeated group nodes. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

nodeId

any

—

Identifier of the grid point addressed by this record.

Accepted words: By, ThreeDimensional, Through, TwoDimensional.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • nodeId — the card needs at least one grid point.

Example record

ContactNodeRegion;22;1001;1010;1005;1006;1101;1110;1105;1106;1201;1210;1205;1206;1301;1310;1305;1306;1401;1410;1405;1406

Model containing this record

Reading the example gives id = 22, bodyParamsId = 1001, dimension = 1010.

ContactNurbsCurve

A 2D rigid contact body made of a NURBS curve.

Record format and fields

ContactNurbsCurve;id;pointCountU;orderU;subdivisions;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

pointCountU

integer

Required

The control points (negative: given by coordinates).

3

orderU

integer

Required

Spline order in the first parametric direction.

4

subdivisions

integer

Required

The subdivisions.

Keyed sections in dataLines

Begin each section with its key, then write its fixed fields and any counted list.

Section Node

Repeated group controlNodes. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

nodeId

integer

—

Identifier of the grid point addressed by this record.

Section Coordinates

Repeated group coordinates. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

coordinate

real

—

Coordinate of the specified point in the selected frame.

Section HomogeneousCoordinates

Repeated group weights. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

homogeneous

real

—

Selects homogeneous coordinates for the rational geometric definition.

Section KnotVector

Repeated group knots. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

knot

real

—

Parameter value in the knot sequence defining the spline.

Accepted words: Coordinates, HomogeneousCoordinates, KnotVector, Node.

Example record

ContactNurbsCurve;80;-2;2;1;Coordinates;4;20.;12.;20.;-2.;HomogeneousCoordinates;2;1.;1.;KnotVector;4;0.;0.;1.;1.

Model containing this record

Reading the example gives id = 80, pointCountU = -2, orderU = 2, subdivisions = 1.

ContactNurbsSurface

A rigid contact body made of a NURBS surface.

Record format and fields

ContactNurbsSurface;id;pointCountU;pointCountV;orderU;orderV;subdivisionsU;subdivisionsV;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

pointCountU

integer

Required

The control points in the U direction (negative: given by coordinates).

3

pointCountV

integer

Required

The control points in the V direction.

4

orderU

integer

Required

Spline order in the first parametric direction.

5

orderV

integer

Required

The order along V.

6

subdivisionsU

integer

Required

The subdivisions along U.

7

subdivisionsV

integer

Required

The subdivisions along V.

Keyed sections in dataLines

Begin each section with its key, then write its fixed fields and any counted list.

Section Node

Repeated group controlNodes. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

nodeId

integer

—

Identifier of the grid point addressed by this record.

Section Coordinates

Repeated group coordinates. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

coordinate

real

—

Coordinate of the specified point in the selected frame.

Section HomogeneousCoordinates

Repeated group weights. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

homogeneous

real

—

Selects homogeneous coordinates for the rational geometric definition.

Section KnotVector

Repeated group knots. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

knot

real

—

Parameter value in the knot sequence defining the spline.

Section Trimming

Repeated group trimCurves. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

trimCurveId

integer

—

Identifier selecting the trim curve record or set.

Accepted words: Coordinates, HomogeneousCoordinates, KnotVector, Node, Trimming.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • trimCurveId — a trimming curve ID must be a positive integer.

Example record

ContactNurbsSurface;60;-2;2;2;2;4;4;Coordinates;12;20.;-2.;-2.;20.;22.;-2.;20.;-2.;12.;20.;22.;12.;HomogeneousCoordinates;4;1.;1.;1.;1.;KnotVector;8;0.;0.;1.;1.;0.;0.;1.;1.;Trimming;1;61

Model containing this record

Reading the example gives id = 60, pointCountU = -2, pointCountV = 2, orderU = 2.

ContactPair

A contact pair: the bodies that touch (secondary, the “touching” bodies) and the bodies they touch (primary), with the parameter sets of the pair.

Record format and fields

ContactPair;id;geomParamsId;physicalParamsId;secondaryBodyId;primaryBodyId;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

geomParamsId

integer

0

Identifier selecting the geom params record or set.

3

physicalParamsId

integer

0

Identifier selecting the physical params record or set.

4

secondaryBodyId

integer

0

Identifier selecting the secondary body record or set.

5

primaryBodyId

integer

0

Identifier selecting the primary body record or set.

Keyed sections in bodyLists

Begin each section with its key, then write its fixed fields and any counted list.

Section Secondary

Repeated group secondaryBodies. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

secondaryBody

integer

—

Body acting as the secondary side of the contact pair.

Section Primary

Repeated group primaryBodies. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

primaryBody

integer

—

Body acting as the primary side of the contact pair.

Accepted words: Primary, Secondary.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • secondaryBodies — a body ID must not be negative.

  • primaryBodyId — a body ID must not be negative.

Example record

ContactPair;11;21;31;1;2

Model containing this record

Reading the example gives id = 11, geomParamsId = 21, physicalParamsId = 31, secondaryBodyId = 1.

ContactPairGeomParams

Sets geometric controls for a contact pair, including search order, interference fit, glue and the initial gap.

Record format and fields

ContactPairGeomParams;id;<parameters>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group parameters. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

any

—

Value assigned to the named parameter. Its interpretation depends on that name.

Accepted words: BilinearCoulomb, Both, Full, GeneralGlue, MonitorDisplacement, No, NodeToSurface, Off, On, PermanentGlue, SegmentToSegment, StandardGlue, TouchOnly, Yes.

Accepted parameter names: AdaptiveContactSurface, AugmentationDistance, AutomaticContact, ContactDistanceTolerance, ContactForceWeighting, ContactMethod, ContactSearchOrder, ContactSide, ContactThickness, ContactTimeControl, ContactToleranceBias, GlueInitialNormalStiffness, GlueInitialTangentStiffness, GlueNormalStiffness, GlueOption, GlueRotationCenter, GlueRotationNormalStiffness, GlueRotationTangentStiffness, GlueSecondRotationCenter, GlueSeparationOption, GlueStiffnessOption, GlueTangentStiffness, HardSoftRatio, IgnoreInitialPenetration, InitialGapDirectionSystem, InitialGapMargin, InitialGapOption, InitialGapSecondTolerance, InitialGapTolerance, InitialMonitor, InterferenceBodyOption, InterferenceCenterX, InterferenceCenterY, InterferenceCenterZ, InterferenceClosure, InterferenceDirectionSystem, InterferenceDirectionX, InterferenceDirectionY, InterferenceDirectionZ, InterferenceOption, InterferenceTable, InterferenceTolerance, MaxParametricCoordinate, MonitorDisplacement, MonitorDisplacementValue, NormalPenaltyFactor, NormalPenaltyScale, PenetrationLimit, SlidingVelocityThreshold, SoftContact, StickSlip, StressFreeInitialContact, TangentPenaltyFactor, TangentPenaltyScale, ThicknessOffset, TouchedBodyOptions, TouchingBodyOptions.

Example record

ContactPairGeomParams;20;GlueOption;1;GlueSeparationOption;0

Model containing this record

Reading the example gives id = 20.

ContactPairPhysicalParams

Sets the physical interaction between a pair of contact bodies, including friction, thermal contact and glue failure.

Record format and fields

ContactPairPhysicalParams;id;<parameters>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group parameters. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

any

—

Value assigned to the named parameter. Its interpretation depends on that name.

Accepted words: Both, Full, No, Off, On, Yes.

Accepted parameter names: ContactDamping, ContactEndTime, ContactHeatTransferCoefficient, ContactStartTime, DistanceDependentConvectionCoefficient, Emissivity, FrictionCoefficient, FrictionDecayCoefficient, FrictionStressLimit, GlueBreakNormalExponent, GlueBreakNormalStress, GlueBreakShearExponent, GlueBreakShearStress, GlueHeatTransfer, InitialPenetrationAdjustment, KineticFrictionCoefficient, NearContactConvectionCoefficient, NearContactDistance, NearContactNaturalConvectionCoefficient, NearContactNaturalConvectionExponent, NearContactNonlinearConvectionCoefficient, NearContactNonlinearConvectionExponent, PenaltyScaleFactor, SeparationForce.

Example record

ContactPairPhysicalParams;30;FrictionCoefficient;0.3

Model containing this record

Reading the example gives id = 30.

ContactParams

Sets named controls for contact detection and response, including separation, friction and geometric tolerance.

Record format and fields

ContactParams;id;parameterName1;parameterValue1;parameterName2;parameterValue2;parameterName3;parameterValue3;<parameters>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

0

Identifier in the namespace of this card type.

2

parameterName1

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list. Entry 1.

3

parameterValue1

any

—

Value assigned to the named parameter. Its interpretation depends on that name. Entry 1.

4

parameterName2

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list. Entry 2.

5

parameterValue2

any

—

Value assigned to the named parameter. Its interpretation depends on that name. Entry 2.

6

parameterName3

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list. Entry 3.

7

parameterValue3

any

—

Value assigned to the named parameter. Its interpretation depends on that name. Entry 3.

Repeated group parameters. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

any

—

Value assigned to the named parameter. Its interpretation depends on that name.

Accepted words: BilinearCoulomb, Both, Full, GeneralGlue, No, NodeToSurface, Off, On, PermanentGlue, SegmentToSegment, StandardGlue, TouchOnly, Yes.

Accepted parameter names: AugmentationDistance, AugmentationOption, AugmentationTime, BackupControl, BeamToBeamContact, ContactAlgorithmVersion, ContactDistanceTolerance, ContactMethod, ContactTimeControl, ContactToleranceBasis, ContactToleranceBias, DisplacementIncrementLimit, DynamicPressureFactor, FrictionKind, GlueInitialNormalStiffness, GlueInitialTangentStiffness, GlueNormalStiffness, GlueOutput, GlueRotationCenter, GlueRotationNormalStiffness, GlueRotationTangentStiffness, GlueSecondRotationCenter, GlueStiffnessOption, GlueTangentStiffness, IgnoreShellThickness, InitialSeparationCheck, LineContact, MaxSeparations, NodeSeparation, NonlinearGlue, NormalPenaltyFactor, NormalPenaltyScale, OutputSplineFreq, ResidualVectorConstant, SegmentAngle, SegmentSymmetry, SeparationAcceleration, SeparationCriterion, SeparationForce, SolidLimit, StickSlip, TangentPenaltyFactor, TangentPenaltyScale.

Example record

ContactParams;0;ContactMethod;NodeToSurface;BeamToBeamContact;1

Model containing this record

Reading the example gives id = 0, parameterName1 = ContactMethod, parameterValue1 = NodeToSurface, parameterName2 = BeamToBeamContact.

ContactPatchSurface

A rigid contact body made of quadrilateral patches.

Record format and fields

ContactPatchSurface;id;<patches>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group patches. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

patchId

integer

—

Identifier selecting the patch record or set.

2

node1

integer

—

Grid point to which this entry applies. Entry 1.

3

node2

integer

—

Grid point to which this entry applies. Entry 2.

4

node3

integer

—

Grid point to which this entry applies. Entry 3.

5

node4

integer

—

Grid point to which this entry applies. Entry 4.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • patchId — the surface needs at least one patch.

  • node — a grid point ID must be a positive integer.

  • node — the four grid points of a patch must be different.

Example record

ContactPatchSurface;51;1;9001;9002;9003;9004

Model containing this record

Reading the example gives id = 51.

ContactPropertyRegion

Selects elements by property to form a three-dimensional contact region.

Record format and fields

ContactPropertyRegion;id;<properties>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group properties. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

propId

any

—

Identifier of the property from which the element obtains its section or constitutive data.

Accepted words: By, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • propIds — the region needs at least one property.

Example record

ContactPropertyRegion;102;2;3;4

Model containing this record

Reading the example gives id = 102.

ContactRigidMotion

The motion of a rigid contact body.

Record format and fields

Forms: noMotionLine, motionLine.

ContactRigidMotion: noMotionLine

Form noMotionLine, when motionLines is a word.

ContactRigidMotion;id;referenceNode;control;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

referenceNode

integer

0

Identifier of the grid point serving as the reference for this definition.

3

control

integer

0

-1 position control, 0 velocity control, a grid point number for load control.

Keyed sections in motionLines

Begin each section with its key, then write its fixed fields and any counted list.

Section ApproachVelocity

Position

Field

Type

Default

Meaning and conventions

1

approachAngularVelocity

real

—

Approach angular velocity (length per time).

2

approachAxis1

real

—

Component 1 of the direction of approach or rigid motion.

3

approachAxis2

real

—

Component 2 of the direction of approach or rigid motion.

4

approachAxis3

real

—

Component 3 of the direction of approach or rigid motion.

5

approachVelocity1

real

—

Approach velocity 1 (length per time).

6

approachVelocity2

real

—

Approach velocity 2 (length per time).

7

approachVelocity3

real

—

Approach velocity 3 (length per time).

Section Growth

Position

Field

Type

Default

Meaning and conventions

1

growthFactor1

real

—

Multiplier for growth.

2

growthFactor2

real

—

Multiplier for growth.

3

growthFactor3

real

—

Multiplier for growth.

4

growthTable1

integer

—

Identifier of the table used at position 1 in the crack-growth relation.

5

growthTable2

integer

—

Identifier of the table used at position 2 in the crack-growth relation.

6

growthTable3

integer

—

Identifier of the table used at position 3 in the crack-growth relation.

ContactRigidMotion: motionLine

Form motionLine, for every other record.

ContactRigidMotion;id;referenceNode;control;loadNode;angularVelocity;axisCosine1;axisCosine2;axisCosine3;rigidVelocity1;rigidVelocity2;rigidVelocity3;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

referenceNode

integer

0

Identifier of the grid point serving as the reference for this definition.

3

control

integer

0

-1 position control, 0 velocity control, a grid point number for load control.

4

loadNode

integer

0

Grid point at which the selected load or control quantity is evaluated.

5

angularVelocity

number

—

Angular velocity (length per time).

6

axisCosine1

number

—

Direction cosine for axis component 1 (dimensionless).

7

axisCosine2

number

—

Direction cosine for axis component 2 (dimensionless).

8

axisCosine3

number

—

Direction cosine for axis component 3 (dimensionless).

9

rigidVelocity1

number

—

Rigid velocity 1 (length per time).

10

rigidVelocity2

number

—

Rigid velocity 2 (length per time).

11

rigidVelocity3

number

—

Rigid velocity 3 (length per time).

Keyed sections in motionLines

Begin each section with its key, then write its fixed fields and any counted list.

Section ApproachVelocity

Position

Field

Type

Default

Meaning and conventions

1

approachAngularVelocity

real

—

Approach angular velocity (length per time).

2

approachAxis1

real

—

Component 1 of the direction of approach or rigid motion.

3

approachAxis2

real

—

Component 2 of the direction of approach or rigid motion.

4

approachAxis3

real

—

Component 3 of the direction of approach or rigid motion.

5

approachVelocity1

real

—

Approach velocity 1 (length per time).

6

approachVelocity2

real

—

Approach velocity 2 (length per time).

7

approachVelocity3

real

—

Approach velocity 3 (length per time).

Section Growth

Position

Field

Type

Default

Meaning and conventions

1

growthFactor1

real

—

Multiplier for growth.

2

growthFactor2

real

—

Multiplier for growth.

3

growthFactor3

real

—

Multiplier for growth.

4

growthTable1

integer

—

Identifier of the table used at position 1 in the crack-growth relation.

5

growthTable2

integer

—

Identifier of the table used at position 2 in the crack-growth relation.

6

growthTable3

integer

—

Identifier of the table used at position 3 in the crack-growth relation.

Accepted words: ApproachVelocity, Growth.

Example record

ContactRigidMotion;20;9110;0;;0.;0.;0.;1.;0.;-0.02

Model containing this record

ContactRigidSurfaceList

Collects rigid surface descriptions into a single region that a contact body can reference.

Record format and fields

ContactRigidSurfaceList;id;<rigidSurfaces>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group rigidSurfaces. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

rigidSurfaceId

integer

—

Identifier selecting the rigid surface record or set.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • rigidSurfaceIds — the list needs at least one rigid surface.

  • rigidSurfaceIds — a rigid surface ID must be a positive integer.

Example record

ContactRigidSurfaceList;50;51;52

Model containing this record

Reading the example gives id = 50.

ContactSegment

A segment of a contact surfacegiven by the grid points of an element face.

Record format and fields

ContactSegment;id;surfaceId;node1;node2;node3;node4

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

surfaceId

integer

Required

Identifier selecting the surface record or set.

3

node1

integer

Required

Grid point to which this entry applies. Entry 1.

4

node2

integer

Required

Grid point to which this entry applies. Entry 2.

5

node3

integer

Required

Grid point to which this entry applies. Entry 3.

6

node4

integer

0

Grid point to which this entry applies. Entry 4.

Example record

ContactSegment;1;12;10;11;14;13

Model containing this record

Reading the example gives id = 1, surfaceId = 12, node1 = 10, node2 = 11.

ContactSet

A contact set of the older contact definition.

Record format and fields

ContactSet;id;<pairs>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group pairs. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

sourceRegionId

integer

—

Identifier selecting the source region record or set.

2

targetRegionId

integer

—

Identifier selecting the target region record or set.

3

friction

real

—

Controls tangential resistance to relative motion at the interface.

4

minimumDistance

real

—

Minimum distance (length).

5

maximumDistance

real

—

Maximum distance (length).

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • sourceRegionId — the set needs at least one contact pair.

Example record

ContactSet;101;2;1;0.1;0.;1.5

Model containing this record

Reading the example gives id = 101.

ContactSetUnion

Combines several contact sets into one selectable set.

Record format and fields

ContactSetUnion;id;<memberSets>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group memberSets. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

memberSetId

integer

—

Identifier selecting the member set record or set.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • memberSetId — the union needs at least one contact set.

  • memberSetId — a contact set ID must be a positive integer.

  • memberSetId — a contact set of the union is not the ID of the union itself.

Example record

ContactSetUnion;200;101;102

Model containing this record

Reading the example gives id = 200.

ContactSlideline

Defines the primary and secondary lines for sliding contact, together with the stiffness, friction and penetration settings.

Record format and fields

ContactSlideline;id;secondaryLineId;primaryLineId;penaltyScale;frictionId;penetrationKind;frameId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

secondaryLineId

integer

Required

Identifier selecting the secondary line record or set.

3

primaryLineId

integer

Required

Identifier selecting the primary line record or set.

4

penaltyScale

real

1.0

Scale of the penalty values the program calculates.

5

frictionId

integer

0

Identifier selecting the friction record or set.

6

penetrationKind

integer

1

Selects the penetration kind for ContactSlideline.

7

frameId

integer

0

Coordinate system in which this entry is expressed.

Example record

ContactSlideline;4;1;2;1.;3;1;0

Model containing this record

Reading the example gives id = 4, secondaryLineId = 1, primaryLineId = 2, penaltyScale = 1..

ContactSurfaceParams

Sets surface interaction options such as normal orientation, stiffness, tying, offsets and activation times.

Record format and fields

ContactSurfaceParams;contactSetId;parameterName1;parameterValue1;parameterName2;parameterValue2;parameterName3;parameterValue3;<parameters>

Position

Field

Type

Default

Meaning and conventions

1

contactSetId

integer

Required

Identifier selecting the contact set record or set.

2

parameterName1

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list. Entry 1.

3

parameterValue1

any

—

Value assigned to the named parameter. Its interpretation depends on that name. Entry 1.

4

parameterName2

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list. Entry 2.

5

parameterValue2

any

—

Value assigned to the named parameter. Its interpretation depends on that name. Entry 2.

6

parameterName3

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list. Entry 3.

7

parameterValue3

any

—

Value assigned to the named parameter. Its interpretation depends on that name. Entry 3.

Repeated group parameters. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

any

—

Value assigned to the named parameter. Its interpretation depends on that name.

Accepted words: Both, Constant, Element, Full, No, Off, On, Table, Yes.

Accepted parameter names: BirthTime, ContactKind, ContactStiffness, DeathTime, ExtensionFactor, InitialPenetration, OffsetDistance, OffsetKind, PenetrationDepth, SegmentNormal, SideCount, TiedContact, TiedTolerance, ZeroPenetrationTime.

Example record

ContactSurfaceParams;101;ContactKind;0;SideCount;2;OffsetDistance;0.

Model containing this record

Reading the example gives contactSetId = 101, parameterName1 = ContactKind, parameterValue1 = 0, parameterName2 = SideCount.

ContactTable

Defines which contact bodies interact in a load case and the associated contact or glue conditions.

Record format and fields

ContactTable;id;secondaryBodyId;primaryBodyId;setCount;secondaryContactOption;primaryContactOption;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

secondaryBodyId

integer

0

Identifier selecting the secondary body record or set.

3

primaryBodyId

integer

0

Identifier selecting the primary body record or set.

4

setCount

integer

1

Number of set entries.

5

secondaryContactOption

integer

0

Selects the secondary contact option for ContactTable.

6

primaryContactOption

integer

0

Selects the primary contact option for ContactTable.

Keyed sections in sets

Begin each section with its key, then write its fixed fields and any counted list.

Section Secondary

Position

Field

Type

Default

Meaning and conventions

1

setSecondaryBodyId

integer

—

Identifier selecting the set secondary body record or set.

2

contactDistanceTolerance

real

—

Permitted numerical deviation for contact distance.

3

separationForce

real

—

Separation force (force).

4

frictionCoefficient

number

—

Coefficient in the relation for friction.

5

interferenceClosure

real

—

Controls how the initial interference is closed during the contact solution.

6

glueOption

integer

—

Selects the glue option for secondarySet.

7

contactSearchOrder

integer

—

Order in which the contact search processes candidate surfaces or bodies.

8

stressFreeInitialContact

integer

—

Controls whether the initially contacting configuration is treated as stress free.

9

glueSeparationOption

integer

—

Selects the glue separation option for secondarySet.

10

nearContactDistance

real

—

Near contact distance (length).

11

kineticFrictionCoefficient

real

—

Coefficient in the relation for kinetic friction.

12

frictionDecayCoefficient

real

—

Coefficient in the relation for friction decay.

13

contactMethod

text

—

Selects the contact method for secondarySet.

14

adaptiveContactSurface

text

—

Selects adaptive treatment of the surface during contact updates.

15

contactThickness

real

—

Contact thickness (length).

16

thicknessOffset

real

—

Offset applied to the thickness surface used in the contact geometry.

17

penetrationLimit

real

—

Largest permitted surface penetration in the contact test.

18

penaltyScaleFactor

real

—

Multiplier for penalty scale.

19

contactStartTime

real

—

Contact start time (time).

20

contactEndTime

real

—

Contact end time (time).

21

maxParametricCoordinate

real

—

Upper bound in the parametric coordinate of the surface or curve.

22

initialPenetrationAdjustment

integer

—

Selects the treatment of initial geometric overlap.

23

ignoreInitialPenetration

integer

—

Selects whether the initial overlap is excluded from the contact correction.

24

automaticContact

text

—

Controls automatic detection or generation of contacting pairs.

25

contactSide

text

—

Side of the surface eligible for contact.

26

contactForceWeighting

text

—

Weighting used when combining or distributing contact forces.

27

monitorDisplacement

text

—

Displacement component or option tracked during the step.

28

monitorDisplacementValue

real

—

Prescribed or target value of the monitored displacement.

29

initialMonitor

real

—

Starting value or selection of the quantity monitored during stepping.

30

contactDamping

text

—

Dissipation assigned to relative normal or tangential motion in contact.

Section Primary

Repeated group primaryBodies. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

primaryBodyIds

integer

—

List of identifiers on the primary side of contact.

Section FrictionAndBias

Position

Field

Type

Default

Meaning and conventions

1

frictionStressLimit

real

—

Upper bound on the tangential frictional stress (force per area).

2

contactToleranceBias

real

—

Bias applied to the geometric contact tolerance.

3

slidingVelocityThreshold

real

—

Relative tangential velocity at which the sliding rule changes.

4

hardSoftRatio

real

—

Relative measure of hard soft.

5

touchingBodyOptions

integer

—

Contact options on the approaching side of the pair.

6

touchedBodyOptions

integer

—

Contact options on the receiving side of the pair.

Section GlueBreak

Position

Field

Type

Default

Meaning and conventions

1

glueBreakNormalStress

real

—

Glue break normal stress (force per area).

2

glueBreakShearStress

real

—

Glue break shear stress (force per area).

3

glueBreakNormalExponent

real

—

Power in the law for glue break normal.

4

glueBreakShearExponent

real

—

Power in the law for glue break shear.

Section SegmentContact

Position

Field

Type

Default

Meaning and conventions

1

normalPenaltyFactor

real

—

Multiplier for normal penalty.

2

augmentationDistance

real

—

Augmentation distance (length).

3

tangentPenaltyFactor

real

—

Multiplier for tangent penalty.

4

stickSlip

real

—

Selects the treatment of sticking and sliding in frictional contact.

Section HeatTransfer

Position

Field

Type

Default

Meaning and conventions

1

contactHeatTransferCoefficient

number

—

Coefficient in the relation for contact heat transfer.

2

nearContactConvectionCoefficient

number

—

Coefficient in the relation for near contact convection.

3

nearContactNaturalConvectionCoefficient

number

—

Coefficient in the relation for near contact natural convection.

4

nearContactNaturalConvectionExponent

number

—

Power in the law for near contact natural convection.

5

emissivity

number

—

Ratio of emitted radiation to that of a black body at the same temperature.

6

distanceDependentConvectionCoefficient

number

—

Coefficient in the relation for distance dependent convection.

7

nearContactNonlinearConvectionCoefficient

number

—

Coefficient in the relation for near contact nonlinear convection.

8

nearContactNonlinearConvectionExponent

number

—

Power in the law for near contact nonlinear convection.

9

glueHeatTransfer

integer

—

Controls thermal transfer through a glued interface.

Accepted words: BilinearCoulomb, Both, FrictionAndBias, Full, GeneralGlue, GlueBreak, HeatTransfer, MonitorDisplacement, No, NodeToSurface, Off, On, PermanentGlue, Primary, PrimaryBodies, PrimaryBody, Secondary, SecondaryBody, SegmentContact, SegmentToSegment, StandardGlue, TouchOnly, Yes.

Accepted parameter names: AdaptiveContactSurface, AugmentationDistance, AutomaticContact, ContactDamping, ContactDistanceTolerance, ContactEndTime, ContactForceWeighting, ContactHeatTransferCoefficient, ContactMethod, ContactSearchOrder, ContactSide, ContactStartTime, ContactThickness, ContactToleranceBias, DistanceDependentConvectionCoefficient, Emissivity, FrictionCoefficient, FrictionDecayCoefficient, FrictionStressLimit, GlueBreakNormalExponent, GlueBreakNormalStress, GlueBreakShearExponent, GlueBreakShearStress, GlueHeatTransfer, GlueOption, GlueSeparationOption, HardSoftRatio, IgnoreInitialPenetration, InitialMonitor, InitialPenetrationAdjustment, InterferenceClosure, KineticFrictionCoefficient, MaxParametricCoordinate, MonitorDisplacement, MonitorDisplacementValue, NearContactConvectionCoefficient, NearContactDistance, NearContactNaturalConvectionCoefficient, NearContactNaturalConvectionExponent, NearContactNonlinearConvectionCoefficient, NearContactNonlinearConvectionExponent, NormalPenaltyFactor, PenaltyScaleFactor, PenetrationLimit, SeparationForce, SlidingVelocityThreshold, StickSlip, StressFreeInitialContact, TangentPenaltyFactor, ThicknessOffset, TouchedBodyOptions, TouchingBodyOptions.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • groups — a touched body ID must be a positive integer.

Example record

ContactTable;1;;;;;;Secondary;2;;;;;3;;;;;;;;;;;;;;;;;;;;;;;;;Primary;1;1

Model containing this record

Reading the example gives id = 1.

ContactTable1

The contact table of a load case, a list of ContactPair contact pairs.

Record format and fields

ContactTable1;id;<pairs>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

0

Identifier in the namespace of this card type.

Repeated group pairs. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

pairId

any

—

Identifier selecting the pair record or set.

Accepted words: By, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • pairIds — the table needs at least one contact pair.

  • pairIds — the first entry must be the ID of a contact pair, not a range.

Example record

ContactTable1;1;11;12;13

Model containing this record

Reading the example gives id = 1.

ContactTrimCurve

The geometry of a trimming curve of a NURBS surface of a rigid contact body.

Record format and fields

ContactTrimCurve;id;pointCount;order;subdivisions;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

pointCount

integer

Required

Number of point entries.

3

order

integer

Required

NORUtrim: the order.

4

subdivisions

integer

Required

NSUBtrim: the subdivisions.

Keyed sections in lists

Begin each section with its key, then write its fixed fields and any counted list.

Section Coordinates

Repeated group coordinates. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

coordinate

real

—

Coordinate of the specified point in the selected frame.

Section HomogeneousCoordinates

Repeated group homogeneousWeights. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

homogeneousWeight

real

—

Weight multiplying the control point in homogeneous coordinates.

Section KnotVector

Repeated group knots. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

knot

real

—

Parameter value in the knot sequence defining the spline.

Accepted words: Coordinates, HomogeneousCoordinates, KnotVector, Node.

Example record

ContactTrimCurve;61;5;2;10;Coordinates;10;0.;0.;1.;0.;1.;1.;0.;1.;0.;0.;HomogeneousCoordinates;5;1.;1.;1.;1.;1.;KnotVector;7;0.;0.;0.25;0.5;0.75;1.;1.

Model containing this record

Reading the example gives id = 61, pointCount = 5, order = 2, subdivisions = 10.

ContactUnglueNodes

The grid points of a contact body that are taken out of glued contact and use standard contact instead (for a crack, the points along it).

Record format and fields

ContactUnglueNodes;id;bodyId;<nodes>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

bodyId

integer

Required

Identifier selecting the body record or set.

Repeated group nodes. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

node

any

—

Grid point to which this entry applies.

Accepted words: By, Constant, Element, Table, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • nodes — the card needs the grid points that leave the glued contact.

Example record

ContactUnglueNodes;10;2;500;Through;502;600;Through;602

Model containing this record

Reading the example gives id = 10, bodyId = 2.

ContactUserService

Associates a contact body with a user routine and supplies the integer, real and text arguments it receives.

Record format and fields

ContactUserService;bodyId;bodyKind;groupName;userRoutineName;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

bodyId

integer

Required

Identifier selecting the body record or set.

2

bodyKind

text

—

Selects the body kind for ContactUserService.

3

groupName

text

—

Text identifier selecting or naming the associated group.

4

userRoutineName

text

—

Name used to identify the user-supplied routine.

Keyed sections in lists

Begin each section with its key, then write its fixed fields and any counted list.

Section IntegerData

Repeated group integerData. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

integerValue

integer

—

Integer payload assigned to the selected setting.

Section RealData

Repeated group realData. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

realValue

real

—

Real scalar value or real part of the complex quantity.

Section TextData

Repeated group textData. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

textValue

text

—

Literal character value assigned to the selected item.

Accepted words: ContactBody, ContactBody1, IntegerData, RealData, TextData.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • textData — textData must not be a section key.

Example record

ContactUserService;1;ContactBody;CONTACT;UFRIC;RealData;1;0.2

Model containing this record

Reading the example gives bodyId = 1, bodyKind = ContactBody, groupName = CONTACT, userRoutineName = UFRIC.

CrackClosureCrack

A crack for the virtual crack closure technique, with the options of its growth, the resistance of the material and the grid points of the crack front.

Record format and fields

CrackClosureCrack;setId;crackId;propagationKind;growthMethod;incrementMethod;growthCriterion;growthIncrement;growthResistance;growthResistanceII;growthResistanceIII;growthIncrementTableId;growthResistanceTableId;growthResistanceIITableId;growthResistanceIIITableId;<nodes>

Position

Field

Type

Default

Meaning and conventions

1

setId

integer

Required

Identifier selecting the set record or set.

2

crackId

integer

1

Identifier selecting the crack record or set.

3

propagationKind

integer

—

Selects the propagation kind for CrackClosureCrack.

4

growthMethod

integer

—

Selects the growth method for CrackClosureCrack.

5

incrementMethod

integer

—

Selects the increment method for CrackClosureCrack.

6

growthCriterion

integer

—

Criterion used to determine whether the crack advances.

7

growthIncrement

real

0.0

Amount by which the crack front advances in one growth increment.

8

growthResistance

real

0.0

Resistance assigned to propagation in the selected fracture mode.

9

growthResistanceII

real

0.0

Resistance to crack growth in in-plane shear (mode II).

10

growthResistanceIII

real

0.0

Resistance to crack growth in out-of-plane shear (mode III).

11

growthIncrementTableId

integer

0

Table supplying the variation of growth increment.

12

growthResistanceTableId

integer

0

Table supplying the variation of growth resistance.

13

growthResistanceIITableId

integer

0

Table supplying the variation of growth resistance ii.

14

growthResistanceIIITableId

integer

0

Table supplying the variation of growth resistance iii.

Repeated group nodes. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

node

any

—

Grid point to which this entry applies.

Accepted words: By, Constant, Element, Table, Through, TypedListSet3.

Example record

CrackClosureCrack;1;1;2;2;1;1;0.;0.3;;;0;;;;503;603

Model containing this record

Reading the example gives setId = 1, crackId = 1, propagationKind = 2, growthMethod = 2.

NonlinearAdaptiveStepping

Controls automatic load or time increments in a nonlinear analysis.

Record format and fields

NonlinearAdaptiveStepping;id;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Keyed sections in lines

Begin each section with its key, then write its fixed fields and any counted list.

Section Stepping

Position

Field

Type

Default

Meaning and conventions

1

minStepRatio

real

—

Relative measure of minimum step.

2

maxStepRatio

real

—

Relative measure of maximum step.

3

minTimeStep

real

—

Shortest permitted time increment (time).

4

maxTimeStep

real

—

Longest permitted time increment (time).

5

maxSubsteps

integer

—

Maximum number of subdivisions of the current step.

6

recycleCount

integer

—

Number of recycle entries.

7

timeStepScaleFactor

real

—

Multiplier for time step scale.

8

dampingKind

integer

—

Selects the damping kind for stepping.

9

dampingFactor

real

—

Multiplier for damping.

Section Creep

Position

Field

Type

Default

Meaning and conventions

1

creepStepCheck

integer

—

Checks the acceptance of a step against creep evolution.

2

tensionCutoffStrain

real

—

Tension cutoff strain (dimensionless).

3

tensionCutoffStress

real

—

Tension cutoff stress (force per area).

4

cutoffTime

real

—

Cutoff time (time).

Accepted words: Creep, DampingKindIndex, RelativeAccelConvergence, Stepping.

Accepted parameter names: CreepStepCheck, CutoffTime, DampingFactor, DampingKind, MaxStepRatio, MaxSubsteps, MaxTimeStep, MinStepRatio, MinTimeStep, RecycleCount, TensionCutoffStrain, TensionCutoffStress, TimeStepScaleFactor.

Example record

NonlinearAdaptiveStepping;30;Stepping;0.1;1.5;0.01;0.5;1000;10;1.2

Model containing this record

Reading the example gives id = 30.

NonlinearBushForceTables

Defines the speed-dependent matrix of force tables referenced by a nonlinear bushing load.

Record format and fields

NonlinearBushForceTables;id;form;minimumFreq;maximumFreq;termTable11;termTable12;termTable13;termTable14;termTable15;termTable16;termTable21;termTable22;termTable23;termTable24;termTable25;termTable26;termTable31;termTable32;termTable33;termTable34;termTable35;termTable36;termTable41;termTable42;termTable43;termTable44;termTable45;termTable46;termTable51;termTable52;termTable53;termTable54;termTable55;termTable56;termTable61;termTable62;termTable63;termTable64;termTable65;termTable66

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

form

text

—

Selects the form for NonlinearBushForceTables.

3

minimumFreq

real

0.0

Lowest frequency of the selected interval (inverse time).

4

maximumFreq

real

—

Highest frequency of the selected interval (inverse time).

5

termTable11

integer

—

Table identifier associated with term 11 in the specified relation.

6

termTable12

integer

—

Table identifier associated with term 12 in the specified relation.

7

termTable13

integer

—

Table identifier associated with term 13 in the specified relation.

8

termTable14

integer

—

Table identifier associated with term 14 in the specified relation.

9

termTable15

integer

—

Table identifier associated with term 15 in the specified relation.

10

termTable16

integer

—

Table identifier associated with term 16 in the specified relation.

11

termTable21

integer

—

Table identifier associated with term 21 in the specified relation.

12

termTable22

integer

—

Table identifier associated with term 22 in the specified relation.

13

termTable23

integer

—

Table identifier associated with term 23 in the specified relation.

14

termTable24

integer

—

Table identifier associated with term 24 in the specified relation.

15

termTable25

integer

—

Table identifier associated with term 25 in the specified relation.

16

termTable26

integer

—

Table identifier associated with term 26 in the specified relation.

17

termTable31

integer

—

Table identifier associated with term 31 in the specified relation.

18

termTable32

integer

—

Table identifier associated with term 32 in the specified relation.

19

termTable33

integer

—

Table identifier associated with term 33 in the specified relation.

20

termTable34

integer

—

Table identifier associated with term 34 in the specified relation.

21

termTable35

integer

—

Table identifier associated with term 35 in the specified relation.

22

termTable36

integer

—

Table identifier associated with term 36 in the specified relation.

23

termTable41

integer

—

Table identifier associated with term 41 in the specified relation.

24

termTable42

integer

—

Table identifier associated with term 42 in the specified relation.

25

termTable43

integer

—

Table identifier associated with term 43 in the specified relation.

26

termTable44

integer

—

Table identifier associated with term 44 in the specified relation.

27

termTable45

integer

—

Table identifier associated with term 45 in the specified relation.

28

termTable46

integer

—

Table identifier associated with term 46 in the specified relation.

29

termTable51

integer

—

Table identifier associated with term 51 in the specified relation.

30

termTable52

integer

—

Table identifier associated with term 52 in the specified relation.

31

termTable53

integer

—

Table identifier associated with term 53 in the specified relation.

32

termTable54

integer

—

Table identifier associated with term 54 in the specified relation.

33

termTable55

integer

—

Table identifier associated with term 55 in the specified relation.

34

termTable56

integer

—

Table identifier associated with term 56 in the specified relation.

35

termTable61

integer

—

Table identifier associated with term 61 in the specified relation.

36

termTable62

integer

—

Table identifier associated with term 62 in the specified relation.

37

termTable63

integer

—

Table identifier associated with term 63 in the specified relation.

38

termTable64

integer

—

Table identifier associated with term 64 in the specified relation.

39

termTable65

integer

—

Table identifier associated with term 65 in the specified relation.

40

termTable66

integer

—

Table identifier associated with term 66 in the specified relation.

Accepted words: AsymmetricForm, Constant, DiagonalForm, Element, SymmetricForm, Table.

Example record

NonlinearBushForceTables;21;DiagonalForm;100.;800.;501;502

Model containing this record

Reading the example gives id = 21, form = DiagonalForm, minimumFreq = 100., maximumFreq = 800..

NonlinearBushLoad3D

Applies a nonlinear three-dimensional force between coincident grid points as a function of relative displacement, velocity and rotor speed.

Record format and fields

NonlinearBushLoad3D;setId;nodeA;nodeB;loadId1;loadId2

Position

Field

Type

Default

Meaning and conventions

1

setId

integer

Required

Identifier selecting the set record or set.

2

nodeA

integer

Required

Identifier addressing node data.

3

nodeB

integer

Required

Identifier addressing node data.

4

loadId1

integer

—

Identifier addressing bushing force set data.

5

loadId2

integer

—

Identifier addressing bushing force set data.

Accepted words: Constant, Element, Table.

Example record

NonlinearBushLoad3D;100;1;2;21;22

Model containing this record

Reading the example gives setId = 100, nodeA = 1, nodeB = 2, loadId1 = 21.

Referenced records in this example

  • Node via nodeA = 1, nodeB = 2.

NonlinearHarmonicFreqContinuation

Specifies forcing frequencies used for continuation in a nonlinear harmonic analysis.

Record format and fields

NonlinearHarmonicFreqContinuation;id;initialFreq;initialStep;minimumStepSize;maximumStepSize;maximumSteps;minimumFreq;maximumFreq;derivativeStep;printOnFailure;outputRequest;outputFreqStep;outputFreqTolerance;outputStartFreq;outputEndFreq

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

initialFreq

real

0.0

Starting frequency of the continuation procedure (inverse time).

3

initialStep

real

Required

First increment used by the stepping procedure.

4

minimumStepSize

real

—

Lower bound on one increment of the continuation variable.

5

maximumStepSize

real

—

Upper bound on one increment of the continuation variable.

6

maximumSteps

integer

3

Maximum number of increments to take.

7

minimumFreq

real

0.0

Lowest frequency of the selected interval (inverse time).

8

maximumFreq

real

—

Highest frequency of the selected interval (inverse time).

9

derivativeStep

real

1.0E-3

Perturbation used to evaluate the derivative numerically.

10

printOnFailure

text

No

Controls diagnostic output when a step fails.

11

outputRequest

text

—

The output request line is there.

12

outputFreqStep

real

—

Frequency spacing between successive outputs.

13

outputFreqTolerance

real

5.0

Permitted numerical deviation for output frequency.

14

outputStartFreq

real

—

Lowest frequency for which output is requested.

15

outputEndFreq

real

—

Highest frequency for which output is requested.

Accepted words: DefaultOutput, No, Yes.

Example record

NonlinearHarmonicFreqContinuation;30;300.;1.;;;400;250.;600.;0.001;No;DefaultOutput;10.;5.;300.;600.

Model containing this record

Reading the example gives id = 30, initialFreq = 300., initialStep = 1., maximumSteps = 400.

NonlinearHarmonicFreqList

The forcing frequencies of a nonlinear harmonic response, listed one by one.

Record format and fields

NonlinearHarmonicFreqList;id;<frequencies>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group frequencies. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

frequency

real

—

Number of cycles per unit time.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • frequencies — the card needs at least one frequency.

  • frequencies — a forcing frequency must be greater than zero.

Example record

NonlinearHarmonicFreqList;16;450.;500.;550.

Model containing this record

Reading the example gives id = 16.

NonlinearHarmonicFreqSteps

The forcing frequencies of a nonlinear harmonic response at equal steps.

Record format and fields

NonlinearHarmonicFreqSteps;id;startFreq;freqStep;stepCount

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

startFreq

real

Required

Starting frequency of the specified range.

3

freqStep

real

Required

Increment in frequency between continuation steps.

4

stepCount

integer

1

Number of step entries.

Example record

NonlinearHarmonicFreqSteps;15;400.;20.;10

Model containing this record

Reading the example gives id = 15, startFreq = 400., freqStep = 20., stepCount = 10.

NonlinearHarmonicParams

The parameters of a nonlinear harmonic response analysis.

Record format and fields

NonlinearHarmonicParams;id;subharmonicFactor;harmonicCount;freqListId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

subharmonicFactor

integer

1

Multiplier for subharmonic.

3

harmonicCount

integer

Required

Number of harmonic entries.

4

freqListId

integer

Required

Identifier addressing nonlinear frequency data.

Example record

NonlinearHarmonicParams;20;2;3;16

Model containing this record

Reading the example gives id = 20, subharmonicFactor = 2, harmonicCount = 3, freqListId = 16.

NonlinearOutputItems

Selects additional quantities for nonlinear result output.

Record format and fields

NonlinearOutputItems;id;<outputItems>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group outputItems. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

outputItem

text

—

Quantity requested for recovery or output.

Accepted words: CauchyCreepStrain, CauchyElasticStrain, CauchyPlasticStrain, CauchyStress, CauchyThermalStrain, CauchyTotalStrain, ElemStateVariables, EquivalentElasticStrain, EquivalentVonMisesStress, FailureIndex1, FailureIndex2, FailureIndex3, FailureIndex4, MajorEngineeringStrain, TotalTemperature.

Example record

NonlinearOutputItems;9;EquivalentVonMisesStress;EquivalentElasticStrain;TTSTRNED

Model containing this record

Reading the example gives id = 9.

NonlinearRadialGap

Defines a circular gap between two coincident grid points for a nonlinear dynamic response.

Record format and fields

NonlinearRadialGap;setId;nodeA;nodeB;plane;stiffnessTableId;clearanceTableId;frictionTableId;radius;smoothing;smoothingValue

Position

Field

Type

Default

Meaning and conventions

1

setId

integer

Required

Identifier selecting the set record or set.

2

nodeA

integer

Required

Identifier addressing node data.

3

nodeB

integer

Required

Identifier addressing node data.

4

plane

text

PlaneXy

Reference plane used for the geometric definition.

5

stiffnessTableId

integer

0

Table supplying the variation of stiffness.

6

clearanceTableId

integer

0

Identifier addressing dynamic table data.

7

frictionTableId

integer

0

Identifier addressing dynamic table data.

8

radius

real

0.0

Radial dimension measured from the centre or axis (length).

9

smoothing

text

—

Selects the treatment of variation between adjacent table samples.

10

smoothingValue

real

1.0E6

The value of the smoothing function.

Accepted words: Gamma, PlaneXy, PlaneYz, PlaneZx.

Example record

NonlinearRadialGap;100;1;2;PlaneXy;401;402;403;;Gamma;1.E+6

Model containing this record

Reading the example gives setId = 100, nodeA = 1, nodeB = 2, plane = PlaneXy.

Referenced records in this example

  • Node via nodeA = 1, nodeB = 2.

  • TableDynamic1 via clearanceTableId = 402, frictionTableId = 403.

NonlinearSqueezeFilmDamper

Defines the transient nonlinear forces from a radial squeeze-film damper between two grid points.

Record format and fields

NonlinearSqueezeFilmDamper;setId;nodeA;nodeB;plane;bearingDiameter;bearingLength;bearingClearance;bearingKind;viscosity;vapourPressure;portCount;pressure1;portAngle1;pressure2;portAngle2;pointCount;offset1;offset2;serviceGroup;serviceEvaluation;serviceParameter1;serviceParameter2;serviceParameter3;serviceParameter4;serviceParameter5;serviceParameter6;serviceParameter7;serviceParameter8

Position

Field

Type

Default

Meaning and conventions

1

setId

integer

Required

Identifier selecting the set record or set.

2

nodeA

integer

Required

Identifier addressing node data.

3

nodeB

integer

Required

Identifier addressing node data.

4

plane

text

PlaneXy

Reference plane used for the geometric definition.

5

bearingDiameter

real

—

Bearing diameter (length).

6

bearingLength

real

—

Bearing length (length).

7

bearingClearance

real

—

Clearance between the bearing and journal surfaces (length).

8

bearingKind

text

Long

Selects the bearing kind for NonlinearSqueezeFilmDamper.

9

viscosity

real

—

Viscous response coefficient in the selected constitutive or flow law.

10

vapourPressure

real

—

Vapour pressure (force per area).

11

portCount

integer

—

Number of port entries.

12

pressure1

real

—

Normal force per unit area, in the model’s pressure units. Entry 1.

13

portAngle1

real

—

The angular position of port 1.

14

pressure2

real

—

Normal force per unit area, in the model’s pressure units. Entry 2.

15

portAngle2

real

—

The angular position of port 2.

16

pointCount

integer

101

Number of point entries.

17

offset1

real

0.0

Shift from the reference location or value in the convention of this entry. Entry 1.

18

offset2

real

0.0

Shift from the reference location or value in the convention of this entry. Entry 2.

19

serviceGroup

text

—

Name identifying the group of user services.

20

serviceEvaluation

text

—

The “evalname” argument passed to the service.

21

serviceParameter1

real

0.0

Argument 1 passed to the user service in the ordered input data.

22

serviceParameter2

real

0.0

Argument 2 passed to the user service in the ordered input data.

23

serviceParameter3

real

0.0

Argument 3 passed to the user service in the ordered input data.

24

serviceParameter4

real

0.0

Argument 4 passed to the user service in the ordered input data.

25

serviceParameter5

real

0.0

Argument 5 passed to the user service in the ordered input data.

26

serviceParameter6

real

0.0

Argument 6 passed to the user service in the ordered input data.

27

serviceParameter7

real

0.0

Argument 7 passed to the user service in the ordered input data.

28

serviceParameter8

real

0.0

Argument 8 passed to the user service in the ordered input data.

Accepted words: Long, PlaneXy, PlaneXz, PlaneYz, PlaneZx, Short.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • values — a field of the card must be a finite number.

Example record

NonlinearSqueezeFilmDamper;100;1;2;PlaneXy;50.;20.;0.1;Short;2.E-8;0.002;1;0.2;90.

Model containing this record

Reading the example gives setId = 100, nodeA = 1, nodeB = 2, plane = PlaneXy.

Referenced records in this example

  • Node via nodeA = 1, nodeB = 2.

NonlinearStepControl

The control parameters of the load or time stepping(mechanical, thermal and coupled analysis) and of the contact analysis.

Record format and fields

NonlinearStepControl;id;totalTime;controlSetting;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

totalTime

real

1.0

Total time (time).

3

controlSetting

text

—

Setting assigned to the named contact or step control.

Keyed sections in lines

Begin each section with its key, then write its fixed fields and any counted list.

Section General

Position

Field

Type

Default

Meaning and conventions

1

maxIterations

integer

—

Maximum number of iterations permitted at this stage.

2

minIterations

integer

—

Minimum number of iterations before the convergence decision.

3

maxBisections

integer

—

Maximum permitted subdivisions of an increment by bisection.

4

creepOption

integer

—

Selects the creep option for general.

Section LoadCaseContinue

Position

Field

Type

Default

Meaning and conventions

1

incrementCountCoupled

integer

—

Number of increments specified for the coupled solution.

2

convergenceCoupled

text

—

Selects convergence criteria for the coupled solution.

3

displacementToleranceCoupled

real

—

Convergence tolerance on displacement for the Coupled solution.

4

loadToleranceCoupled

real

—

Convergence tolerance on load for the Coupled solution.

5

energyToleranceCoupled

real

—

Convergence tolerance on energy for the Coupled solution.

6

maxDivergencesCoupled

integer

—

Upper bound on Divergences for the Coupled increment.

7

maxBisectionsCoupled

integer

—

Upper bound on Bisections for the Coupled increment.

8

maxIterationsCoupled

integer

—

Upper bound on Iterations for the Coupled increment.

9

minIterationsCoupled

integer

—

Minimum iterations before checking convergence of the coupled increment.

Section FixedStepping

Position

Field

Type

Default

Meaning and conventions

1

incrementCount

integer

—

Number of increment entries.

2

outputInterval

integer

—

Spacing between successive output requests.

Section AdaptiveStepping

Position

Field

Type

Default

Meaning and conventions

1

initialTimeStepFactor

real

—

Multiplier for initial time step.

2

minTimeStepFactor

real

—

Multiplier for minimum time step.

3

maxTimeStepFactor

real

—

Multiplier for maximum time step.

4

desiredIterations

integer

—

Target iteration count used when adjusting the next increment.

5

timeStepScaleFactor

real

—

Multiplier for time step scale.

6

intermediateOutput

integer

—

Controls output at intermediate increments or stations.

7

maxSubsteps

integer

—

Maximum number of subdivisions of the current step.

8

dampingKind

integer

—

Selects the damping kind for adaptiveStepping.

9

dampingFactor

real

—

Multiplier for damping.

10

criteriaTableId

integer

—

Table supplying the variation of criteria.

11

physicsOption

integer

—

Selects the physics option for adaptiveStepping.

12

targetLimit

integer

—

Limit on the monitored quantity used to accept or change the step.

13

minStepRatio

real

—

Relative measure of minimum step.

14

maxStepRatio

real

—

Relative measure of maximum step.

15

timeStepAdjustInterval

integer

—

Number or interval of steps between changes to the step size.

16

stepMultiplier

integer

—

Factor applied to the preceding step size.

17

timeStepHoldBounds

real

—

Controls the bounds maintained while the step size is held fixed.

18

displacementConvergence

real

—

Specifies the criterion based on change in displacement.

Section ArcLengthMethod

Position

Field

Type

Default

Meaning and conventions

1

steppingMethod

text

—

Selects the stepping method for arcLengthMethod.

2

initialTimeStepFactorAdapted

real

—

Multiplier on the first adaptive time increment.

3

minAdaptiveRatio

real

—

Relative measure of minimum adaptive.

4

maxAdaptiveRatio

real

—

Relative measure of maximum adaptive.

5

desiredIterationsAdapted

integer

—

Target iteration count for adaptive increment control.

6

maxSubstepsAdapted

integer

—

Maximum number of adaptive subdivisions of an increment.

Section HeatAnalysis

Position

Field

Type

Default

Meaning and conventions

1

convergenceHeat

text

—

Selects convergence criteria for the heat-transfer solution.

2

displacementToleranceHeat

real

—

Convergence tolerance on displacement for the Heat solution.

3

loadToleranceHeat

real

—

Convergence tolerance on load for the Heat solution.

4

energyToleranceHeat

real

—

Convergence tolerance on energy for the Heat solution.

5

stiffnessMethodHeat

text

—

Selects the matrix-update method in the thermal solution.

6

stiffnessStepHeat

integer

—

Increment interval for updating the thermal tangent matrix.

7

maxQuasiNewtonVectorsHeat

integer

—

Upper bound on QuasiNewtonVectors for the Heat increment.

8

maxLineSearchesHeat

integer

—

Upper bound on LineSearches for the Heat increment.

9

lineSearchToleranceHeat

real

—

Tolerance controlling termination of the thermal line search.

Section MechanicalAnalysis

Position

Field

Type

Default

Meaning and conventions

1

convergenceCriteria

text

—

Selects the residual or increment measures checked for convergence.

2

displacementTolerance

real

—

Permitted numerical deviation for displacement.

3

loadTolerance

real

—

Permitted numerical deviation for load.

4

energyTolerance

real

—

Permitted numerical deviation for energy.

5

stiffnessMethod

text

—

Selects the stiffness method for mechanicalAnalysis.

6

stiffnessUpdateStep

integer

—

Step interval or stage at which the tangent stiffness is updated.

7

massRatioConvergence

integer

—

Mass-ratio criterion used when checking convergence of the step.

8

maxQuasiNewtonVectors

integer

—

Limit on the vectors retained in a quasi-Newton update.

9

maxLineSearches

integer

—

Maximum line-search updates in an iteration.

10

lineSearchTolerance

real

—

Permitted numerical deviation for line search.

11

frictionStress

real

—

Friction stress (force per area).

Section CoupledAnalysis

Position

Field

Type

Default

Meaning and conventions

1

heatFromPlasticWork

real

—

Specifies conversion of plastic work into heat.

2

heatFromFriction

real

—

Specifies conversion of frictional work into heat at the interface.

Accepted words: AdaptiveStepping, ArcLengthMethod, CoupledAnalysis, Crisfield, CriteriaTableIdKind, FixedStepping, General, HeatAnalysis, LoadCaseAccumulation, LoadCaseContinue, LoadCasePerformance, MechanicalAnalysis, MildlyNonlinear, ModifiedRiks, QuasiLinear, Riks, SeverelyNonlinear, TypeKind.

Accepted parameter names: ConvergenceCoupled, ConvergenceCriteria, ConvergenceHeat, CreepOption, CriteriaTableId, DampingFactor, DampingKind, DesiredIterations, DesiredIterationsAdapted, DisplacementConvergence, DisplacementTolerance, DisplacementToleranceCoupled, DisplacementToleranceHeat, EnergyTolerance, EnergyToleranceCoupled, EnergyToleranceHeat, FrictionStress, HeatFromFriction, HeatFromPlasticWork, IncrementCount, IncrementCountCoupled, InitialTimeStepFactor, InitialTimeStepFactorAdapted, IntermediateOutput, LineSearchTolerance, LineSearchToleranceHeat, LoadTolerance, LoadToleranceCoupled, LoadToleranceHeat, MassRatioConvergence, MaxAdaptiveRatio, MaxBisections, MaxBisectionsCoupled, MaxDivergencesCoupled, MaxIterations, MaxIterationsCoupled, MaxLineSearches, MaxLineSearchesHeat, MaxQuasiNewtonVectors, MaxQuasiNewtonVectorsHeat, MaxStepRatio, MaxSubsteps, MaxSubstepsAdapted, MaxTimeStepFactor, MinAdaptiveRatio, MinIterations, MinIterationsCoupled, MinStepRatio, MinTimeStepFactor, OutputInterval, PhysicsOption, StepMultiplier, SteppingMethod, StiffnessMethod, StiffnessMethodHeat, StiffnessStepHeat, StiffnessUpdateStep, TargetLimit, TimeStepAdjustInterval, TimeStepHoldBounds, TimeStepScaleFactor.

Example record

NonlinearStepControl;1;1.;;AdaptiveStepping;0.1;1.E-4;0.25

Model containing this record

Reading the example gives id = 1, totalTime = 1..

NonlinearUserOutput

Declares output quantities provided by a user routine for an explicit nonlinear analysis.

Record format and fields

NonlinearUserOutput;id;groupName;outputKind;timeInterval;stepInterval;outputName;<entities>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

groupName

text

—

Text identifier selecting or naming the associated group.

3

outputKind

text

ElemExplicitOutput

Selects the output kind for NonlinearUserOutput.

4

timeInterval

real

—

Time between the events or updates specified by the record.

5

stepInterval

integer

—

Spacing of the steps at which this action is taken.

6

outputName

text

—

Text naming the output.

Repeated group entities. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

entityId

integer

—

Identifier selecting the entity record or set.

Accepted words: ElemExplicitOutput, NodeExplicitOutput.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • entityIds — the card needs at least one element or grid point.

  • entityIds — an element or grid point ID must be a positive integer.

Example record

NonlinearUserOutput;91;initex;ElemExplicitOutput;1.E-4;;BOXOUT;1001;1002;1003;1004;1005;1006

Model containing this record

Reading the example gives id = 91, groupName = initex, outputKind = ElemExplicitOutput, timeInterval = 1.E-4.

SlidelineFriction

The friction between two bodies of a slideline contact region.

Record format and fields

SlidelineFriction;id;stickStiffness;staticFriction

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

stickStiffness

real

0.0

Tangential stiffness used while the interface sticks.

3

staticFriction

real

Required

The coefficient of static friction.

Example record

SlidelineFriction;3;;0.2

Model containing this record

Reading the example gives id = 3, staticFriction = 0.2.

SlidelineOutput

The secondary nodes at which a slideline contact analysis writes output.

Record format and fields

SlidelineOutput;id;<nodes>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

Repeated group nodes. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

node

any

—

Grid point to which this entry applies.

Accepted words: All, By, Through.

Example record

SlidelineOutput;4;201;Through;203

Model containing this record

Reading the example gives id = 4.

SlidelineSegments

A curve of line segments of a slideline contact region, given by its grid points in topological order (one segment between every two consecutive points).

Record format and fields

SlidelineSegments;id;<nodes>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group nodes. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

node

any

—

Grid point to which this entry applies.

Accepted words: By, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • node — the line needs at least one grid point.

Example record

SlidelineSegments;1;203;202;201

Model containing this record

Reading the example gives id = 1.

SlidelineWidth

The width (3-D slideline) or thickness (2-D) of each line segment of the SlidelineSegments of the same ID.

Record format and fields

SlidelineWidth;segmentsId;<widths>

Position

Field

Type

Default

Meaning and conventions

1

segmentsId

integer

Required

Identifier addressing slideline segments data.

Repeated group widths. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

width

any

—

Transverse extent in model length units.

Accepted words: By, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • width — the card needs at least one width.

  • width — a width must be greater than zero.

  • width — a single width has no end.

  • rangeStep — the BY increment must be a finite number.

  • rangeStep — the BY increment must go from the first width to the last one.

Example record

SlidelineWidth;2;10.;10.;10.;10.

Model containing this record

Reading the example gives segmentsId = 2.

StepControlCriteria

Defines target increments or bounds for monitored quantities used by NonlinearStepControl.

Record format and fields

StepControlCriteria;id;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Keyed sections in criteria

Begin each section with its key, then write its fixed fields and any counted list.

Section StrainIncrement

Position

Field

Type

Default

Meaning and conventions

1

setId

any

—

Identifier selecting the set record or set.

2

limit1

real

—

Increment limit or target for criterion range 1.

3

rangeEnd1

real

—

Endpoint in the criterion variable defining range 1.

4

limit2

real

—

Increment limit or target for criterion range 2.

5

rangeEnd2

real

—

Endpoint in the criterion variable defining range 2.

6

limit3

real

—

Increment limit or target for criterion range 3.

7

rangeEnd3

real

—

Endpoint in the criterion variable defining range 3.

8

limit4

real

—

Increment limit or target for criterion range 4.

9

rangeEnd4

real

—

Endpoint in the criterion variable defining range 4.

Section PlasticStrainIncrement

Position

Field

Type

Default

Meaning and conventions

1

setId

any

—

Identifier selecting the set record or set.

2

limit1

real

—

Increment limit or target for criterion range 1.

3

rangeEnd1

real

—

Endpoint in the criterion variable defining range 1.

4

limit2

real

—

Increment limit or target for criterion range 2.

5

rangeEnd2

real

—

Endpoint in the criterion variable defining range 2.

6

limit3

real

—

Increment limit or target for criterion range 3.

7

rangeEnd3

real

—

Endpoint in the criterion variable defining range 3.

8

limit4

real

—

Increment limit or target for criterion range 4.

9

rangeEnd4

real

—

Endpoint in the criterion variable defining range 4.

Section CreepStrainIncrement

Position

Field

Type

Default

Meaning and conventions

1

setId

any

—

Identifier selecting the set record or set.

2

limit1

real

—

Increment limit or target for criterion range 1.

3

rangeEnd1

real

—

Endpoint in the criterion variable defining range 1.

4

limit2

real

—

Increment limit or target for criterion range 2.

5

rangeEnd2

real

—

Endpoint in the criterion variable defining range 2.

6

limit3

real

—

Increment limit or target for criterion range 3.

7

rangeEnd3

real

—

Endpoint in the criterion variable defining range 3.

8

limit4

real

—

Increment limit or target for criterion range 4.

9

rangeEnd4

real

—

Endpoint in the criterion variable defining range 4.

Section NormalizedCreepStrainIncrement

Position

Field

Type

Default

Meaning and conventions

1

setId

any

—

Identifier selecting the set record or set.

2

limit1

real

—

Increment limit or target for criterion range 1.

3

rangeEnd1

real

—

Endpoint in the criterion variable defining range 1.

4

limit2

real

—

Increment limit or target for criterion range 2.

5

rangeEnd2

real

—

Endpoint in the criterion variable defining range 2.

6

limit3

real

—

Increment limit or target for criterion range 3.

7

rangeEnd3

real

—

Endpoint in the criterion variable defining range 3.

8

limit4

real

—

Increment limit or target for criterion range 4.

9

rangeEnd4

real

—

Endpoint in the criterion variable defining range 4.

Section StressIncrement

Position

Field

Type

Default

Meaning and conventions

1

setId

any

—

Identifier selecting the set record or set.

2

limit1

real

—

Increment limit or target for criterion range 1.

3

rangeEnd1

real

—

Endpoint in the criterion variable defining range 1.

4

limit2

real

—

Increment limit or target for criterion range 2.

5

rangeEnd2

real

—

Endpoint in the criterion variable defining range 2.

6

limit3

real

—

Increment limit or target for criterion range 3.

7

rangeEnd3

real

—

Endpoint in the criterion variable defining range 3.

8

limit4

real

—

Increment limit or target for criterion range 4.

9

rangeEnd4

real

—

Endpoint in the criterion variable defining range 4.

Section StrainEnergyIncrement

Position

Field

Type

Default

Meaning and conventions

1

setId

any

—

Identifier selecting the set record or set.

2

limit1

real

—

Increment limit or target for criterion range 1.

3

rangeEnd1

real

—

Endpoint in the criterion variable defining range 1.

4

limit2

real

—

Increment limit or target for criterion range 2.

5

rangeEnd2

real

—

Endpoint in the criterion variable defining range 2.

6

limit3

real

—

Increment limit or target for criterion range 3.

7

rangeEnd3

real

—

Endpoint in the criterion variable defining range 3.

8

limit4

real

—

Increment limit or target for criterion range 4.

9

rangeEnd4

real

—

Endpoint in the criterion variable defining range 4.

Section TemperatureIncrement

Position

Field

Type

Default

Meaning and conventions

1

setId

any

—

Identifier selecting the set record or set.

2

limit1

real

—

Increment limit or target for criterion range 1.

3

rangeEnd1

real

—

Endpoint in the criterion variable defining range 1.

4

limit2

real

—

Increment limit or target for criterion range 2.

5

rangeEnd2

real

—

Endpoint in the criterion variable defining range 2.

6

limit3

real

—

Increment limit or target for criterion range 3.

7

rangeEnd3

real

—

Endpoint in the criterion variable defining range 3.

8

limit4

real

—

Increment limit or target for criterion range 4.

9

rangeEnd4

real

—

Endpoint in the criterion variable defining range 4.

Section DisplacementIncrement

Position

Field

Type

Default

Meaning and conventions

1

setId

any

—

Identifier selecting the set record or set.

2

limit1

real

—

Increment limit or target for criterion range 1.

3

rangeEnd1

real

—

Endpoint in the criterion variable defining range 1.

4

limit2

real

—

Increment limit or target for criterion range 2.

5

rangeEnd2

real

—

Endpoint in the criterion variable defining range 2.

6

limit3

real

—

Increment limit or target for criterion range 3.

7

rangeEnd3

real

—

Endpoint in the criterion variable defining range 3.

8

limit4

real

—

Increment limit or target for criterion range 4.

9

rangeEnd4

real

—

Endpoint in the criterion variable defining range 4.

Section RotationIncrement

Position

Field

Type

Default

Meaning and conventions

1

setId

any

—

Identifier selecting the set record or set.

2

limit1

real

—

Increment limit or target for criterion range 1.

3

rangeEnd1

real

—

Endpoint in the criterion variable defining range 1.

4

limit2

real

—

Increment limit or target for criterion range 2.

5

rangeEnd2

real

—

Endpoint in the criterion variable defining range 2.

6

limit3

real

—

Increment limit or target for criterion range 3.

7

rangeEnd3

real

—

Endpoint in the criterion variable defining range 3.

8

limit4

real

—

Increment limit or target for criterion range 4.

9

rangeEnd4

real

—

Endpoint in the criterion variable defining range 4.

Section NormalizedStressIncrement

Position

Field

Type

Default

Meaning and conventions

1

setId

any

—

Identifier selecting the set record or set.

2

limit1

real

—

Increment limit or target for criterion range 1.

3

rangeEnd1

real

—

Endpoint in the criterion variable defining range 1.

4

limit2

real

—

Increment limit or target for criterion range 2.

5

rangeEnd2

real

—

Endpoint in the criterion variable defining range 2.

6

limit3

real

—

Increment limit or target for criterion range 3.

7

rangeEnd3

real

—

Endpoint in the criterion variable defining range 3.

8

limit4

real

—

Increment limit or target for criterion range 4.

9

rangeEnd4

real

—

Endpoint in the criterion variable defining range 4.

Accepted words: All, Constant, CreepStrainIncrement, DisplacementIncrement, Element, NormalizedCreepStrainIncrement, NormalizedStressIncrement, PlasticStrainIncrement, RotationIncrement, StrainEnergyIncrement, StrainIncrement, StressIncrement, Table, TemperatureIncrement.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • criterion — the table needs at least one criterion.

Example record

StepControlCriteria;40;DisplacementIncrement;41;0.005;;;;;;;;StrainIncrement;All;0.001