Elements and connections

All card families and alphabetical index

Read field positions from left to right within each table. A dash means the layout supplies no fixed default. Use a consistent system of units for dimensional quantities.

AcousticAbsorberProp

The property of an AcousticAbsorber frequency-dependent acoustic absorber element.

Record format and fields

AcousticAbsorberProp;id;resistanceTableId;reactanceTableId;impedanceScale;area;damping;stiffness;characteristicImpedance

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

resistanceTableId

integer

0

Identifier addressing dynamic table data.

3

reactanceTableId

integer

0

Identifier addressing dynamic table data.

4

impedanceScale

real

1.0

Multiplier on the acoustic impedance assigned to the element.

5

area

real

1.0

Surface or cross-sectional measure, in squared model length units.

6

damping

real

0.0

Dissipative coefficient of the selected connection, material or response law.

7

stiffness

real

0.0

Elastic restoring coefficient relating generalized force to the associated displacement.

8

characteristicImpedance

real

1.0

Pressure-to-particle-velocity ratio used as the acoustic reference impedance.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the property ID must be a positive integer.

  • resistanceTableId — a table ID cannot be negative.

Example record

AcousticAbsorberProp;31;32;33;1.;;;;4.13E-7

Model containing this record

Reading the example gives id = 31, resistanceTableId = 32, reactanceTableId = 33, impedanceScale = 1..

Referenced records in this example

  • TableDynamic1 via resistanceTableId = 32, reactanceTableId = 33.

AcousticAxisymFluid2

An axisymmetric fluid element that connects two fluid points (the fluid of an axisymmetric slot or cavity analysis, together with an AcousticSlotControl card).

Record format and fields

AcousticAxisymFluid2;id;fluidPointId1;fluidPointId2;density;bulkModulus

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

fluidPointId1

integer

Required

Identifier selecting the fluid point record or set.

3

fluidPointId2

integer

Required

Identifier selecting the fluid point record or set.

4

density

real

—

Mass per unit volume for a volumetric material or fluid density.

5

bulkModulus

real

—

Resistance to volumetric compression, expressed as pressure.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — id must be an integer from 1 to 99999999.

Example record

AcousticAxisymFluid2;101;1;2

Model containing this record

Reading the example gives id = 101, fluidPointId1 = 1, fluidPointId2 = 2.

AcousticAxisymFluid3

An axisymmetric fluid element that connects three fluid points (the fluid of an axisymmetric slot or cavity analysis, together with an AcousticSlotControl card).

Record format and fields

AcousticAxisymFluid3;id;fluidPointId1;fluidPointId2;fluidPointId3;density;bulkModulus

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

fluidPointId1

integer

Required

Identifier selecting the fluid point record or set.

3

fluidPointId2

integer

Required

Identifier selecting the fluid point record or set.

4

fluidPointId3

integer

Required

Identifier selecting the fluid point record or set.

5

density

real

—

Mass per unit volume for a volumetric material or fluid density.

6

bulkModulus

real

—

Resistance to volumetric compression, expressed as pressure.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — id must be an integer from 1 to 99999999.

Example record

AcousticAxisymFluid3;105;2;13;3

Model containing this record

Reading the example gives id = 105, fluidPointId1 = 2, fluidPointId2 = 13, fluidPointId3 = 3.

AcousticAxisymFluid4

An axisymmetric fluid element that connects four fluid points (the fluid of an axisymmetric slot or cavity analysis, together with an AcousticSlotControl card).

Record format and fields

AcousticAxisymFluid4;id;fluidPointId1;fluidPointId2;fluidPointId3;fluidPointId4;density;bulkModulus

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

fluidPointId1

integer

Required

Identifier selecting the fluid point record or set.

3

fluidPointId2

integer

Required

Identifier selecting the fluid point record or set.

4

fluidPointId3

integer

Required

Identifier selecting the fluid point record or set.

5

fluidPointId4

integer

Required

Identifier selecting the fluid point record or set.

6

density

real

—

Mass per unit volume for a volumetric material or fluid density.

7

bulkModulus

real

—

Resistance to volumetric compression, expressed as pressure.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — id must be an integer from 1 to 99999999.

Example record

AcousticAxisymFluid4;103;1;11;12;2

Model containing this record

Reading the example gives id = 103, fluidPointId1 = 1, fluidPointId2 = 11, fluidPointId3 = 12.

AcousticInfiniteProp

The property of the acoustic conjugate infinite elements (AcousticInfiniteTria3 and AcousticInfiniteQuad4).

Record format and fields

AcousticInfiniteProp;id;matId;radialOrder;poleX;poleY;poleZ

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

3

radialOrder

integer

Required

Radial interpolation order, greater than zero.

4

poleX

real

0.0

X coordinate of the pole.

5

poleY

real

0.0

Y coordinate of the pole.

6

poleZ

real

0.0

Z coordinate of the pole.

Accepted words: Constant, Element, Table.

Example record

AcousticInfiniteProp;31;2;5;100.;100.;0.

Model containing this record

Reading the example gives id = 31, matId = 2, radialOrder = 5, poleX = 100..

Referenced records in this example

AcousticInfiniteQuad4

The base of an acoustic conjugate infinite element, a quadrilateral of four acoustic grid points.

Record format and fields

AcousticInfiniteQuad4;id;propId;node1;node2;node3;node4

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

Accepted words: Constant, Element, Table.

Example record

AcousticInfiniteQuad4;3001;31;1001;1006;1106;1101

Model containing this record

Reading the example gives id = 3001, propId = 31, node1 = 1001, node2 = 1006.

Referenced records in this example

AcousticInfiniteTria3

The base of an acoustic conjugate infinite element, a triangle of three acoustic grid points.

Record format and fields

AcousticInfiniteTria3;id;propId;node1;node2;node3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

Accepted words: Constant, Element, Table.

Example record

AcousticInfiniteTria3;3033;31;1201;1202;1207

Model containing this record

Reading the example gives id = 3033, propId = 31, node1 = 1201, node2 = 1202.

Referenced records in this example

AcousticSlot3

A three-point slot element of the acoustic cavity analysis (an evenly spaced radial slot that solves the wave equation in two dimensions).

Record format and fields

AcousticSlot3;id;slotPoint1;slotPoint2;slotPoint3;density;bulkModulus;slotCount

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

slotPoint1

integer

—

Point defining the location on the acoustic slot. Entry 1.

3

slotPoint2

integer

—

Point defining the location on the acoustic slot. Entry 2.

4

slotPoint3

integer

—

Point defining the location on the acoustic slot. Entry 3.

5

density

real

—

Mass per unit volume for a volumetric material or fluid density.

6

bulkModulus

real

—

Resistance to volumetric compression, expressed as pressure.

7

slotCount

integer

—

Number of slot entries.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be an integer from 1 to 99999999.

Example record

AcousticSlot3;203;22;32;33

Model containing this record

Reading the example gives id = 203, slotPoint1 = 22, slotPoint2 = 32, slotPoint3 = 33.

AcousticSlot4

A four-point slot element of the acoustic cavity analysis (an evenly spaced radial slot that solves the wave equation in two dimensions).

Record format and fields

AcousticSlot4;id;slotPoint1;slotPoint2;slotPoint3;slotPoint4;density;bulkModulus;slotCount

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

slotPoint1

integer

—

Point defining the location on the acoustic slot. Entry 1.

3

slotPoint2

integer

—

Point defining the location on the acoustic slot. Entry 2.

4

slotPoint3

integer

—

Point defining the location on the acoustic slot. Entry 3.

5

slotPoint4

integer

—

Point defining the location on the acoustic slot. Entry 4.

6

density

real

—

Mass per unit volume for a volumetric material or fluid density.

7

bulkModulus

real

—

Resistance to volumetric compression, expressed as pressure.

8

slotCount

integer

—

Number of slot entries.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be an integer from 1 to 99999999.

Example record

AcousticSlot4;201;21;31;32;22

Model containing this record

Reading the example gives id = 201, slotPoint1 = 21, slotPoint2 = 31, slotPoint3 = 32.

AxisymQuad

An axisymmetric quadrilateral element with four corners, up to four edge points and an optional centre point.

Record format and fields

AxisymQuad;id;propId;node1;node2;node3;node4;node5;node6;node7;node8;node9;materialAngle;matFrameId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

node5

integer

—

Grid point to which this entry applies. Entry 5.

8

node6

integer

—

Grid point to which this entry applies. Entry 6.

9

node7

integer

—

Grid point to which this entry applies. Entry 7.

10

node8

integer

—

Grid point to which this entry applies. Entry 8.

11

node9

integer

—

Grid point to which this entry applies. Entry 9.

12

materialAngle

real

—

Angle defining the material orientation relative to the reference element axes. Alternative to matFrameId.

13

matFrameId

integer

—

Coordinate system defining the material directions. Alternative to materialAngle.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the corner grid points must be positive integers.

  • node5 — the grid point IDs must not be negative.

  • node1 — the grid points of an element must all be different.

Example record

AxisymQuad;1;1;1;2;5;4

Model containing this record

Reading the example gives id = 1, propId = 1, node1 = 1, node2 = 2.

Referenced records in this example

AxisymQuad4

A four-node axisymmetric quadrilateral ring element.

Record format and fields

AxisymQuad4;id;propId;node1;node2;node3;node4;materialAngle

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

materialAngle

real

0.0

Angle defining the material orientation relative to the reference element axes.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the grid point IDs must be positive integers.

  • node1 — the four grid points must all be different.

Example record

AxisymQuad4;201;3;201;202;203;204

Model containing this record

Reading the example gives id = 201, propId = 3, node1 = 201, node2 = 202.

Referenced records in this example

  • SolidProp via propId = 3.

  • Node via node1 = 201, node2 = 202, node3 = 203, node4 = 204.

AxisymQuad8

An axisymmetric quadrilateral ring element with four corners and up to four edge points.

Record format and fields

AxisymQuad8;id;propId;node1;node2;node3;node4;node5;node6;node7;node8;materialAngle

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

node5

integer

—

Grid point to which this entry applies. Entry 5.

8

node6

integer

—

Grid point to which this entry applies. Entry 6.

9

node7

integer

—

Grid point to which this entry applies. Entry 7.

10

node8

integer

—

Grid point to which this entry applies. Entry 8.

11

materialAngle

real

0.0

Angle defining the material orientation relative to the reference element axes.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the corner grid points must be positive integers.

  • node5 — the grid point IDs must not be negative.

  • node1 — the grid points of an element must all be different.

Example record

AxisymQuad8;202;3;205;206;207;208;209;210;211;212;0.

Model containing this record

Reading the example gives id = 202, propId = 3, node1 = 205, node2 = 206.

Referenced records in this example

  • SolidProp via propId = 3.

  • Node via node1 = 205, node2 = 206, node3 = 207, node4 = 208, node5 = 209, node6 = 210, node7 = 211, node8 = 212.

AxisymTria

An axisymmetric triangular element with three corners and up to three edge points.

Record format and fields

AxisymTria;id;propId;node1;node2;node3;node4;node5;node6;materialAngle;matFrameId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

node5

integer

—

Grid point to which this entry applies. Entry 5.

8

node6

integer

—

Grid point to which this entry applies. Entry 6.

9

materialAngle

real

—

Angle defining the material orientation relative to the reference element axes. Alternative to matFrameId.

10

matFrameId

integer

—

Coordinate system defining the material directions. Alternative to materialAngle.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the corner grid points must be positive integers.

  • node4 — the grid point IDs must not be negative.

  • node1 — the grid points of an element must all be different.

Example record

AxisymTria;4;40;4;5;10

Model containing this record

Reading the example gives id = 4, propId = 40, node1 = 4, node2 = 5.

Referenced records in this example

AxisymTria6

An axisymmetric triangular cross-section ring element with up to six grid points.

Record format and fields

AxisymTria6;id;matId;node1;node2;node3;node4;node5;node6;materialAngle

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

node5

integer

—

Grid point to which this entry applies. Entry 5.

8

node6

integer

—

Grid point to which this entry applies. Entry 6.

9

materialAngle

real

0.0

Angle defining the material orientation relative to the reference element axes.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • matId — the material ID must be a positive integer.

  • node1 — the corner grid points node1, node3 and node5 must be positive integers.

  • node2 — the grid point IDs must not be negative.

  • node1 — the grid points of an element must all be different.

Example record

AxisymTria6;1;1;11;12;13;16;19;15

Model containing this record

Reading the example gives id = 1, matId = 1, node1 = 11, node2 = 12.

Referenced records in this example

  • IsoMat via matId = 1.

  • Node via node1 = 11, node2 = 12, node3 = 13, node4 = 16, node5 = 19, node6 = 15.

Bar2

A simple beam element.

Record format and fields

Bar2;id;propId;nodeA;nodeB;orientation1;orientationNode;orientation2;orientation3;offsetKind;pinFlagsA;pinFlagsB;offset1A;offset2A;offset3A;offset1B;offset2B;offset3B

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

nodeA

integer

Required

Identifier addressing node data.

4

nodeB

integer

Required

Identifier addressing node data.

5

orientation1

real

—

First component of the vector defining the element orientation. Alternative to orientationNode.

6

orientationNode

integer

—

Grid point defining the orientation direction in place of explicit vector components. Alternative to orientation1.

7

orientation2

real

0.0

Second component of the vector defining the element orientation.

8

orientation3

real

0.0

Third component of the vector defining the element orientation.

9

offsetKind

text

—

Selects the offset kind for Bar2.

10

pinFlagsA

integer

0

Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6.

11

pinFlagsB

integer

0

Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6.

12

offset1A

real

—

Component 1 of the offset vector at end A in the specified frame.

13

offset2A

real

—

Component 2 of the offset vector at end A in the specified frame.

14

offset3A

real

—

Component 3 of the offset vector at end A in the specified frame.

15

offset1B

real

—

Component 1 of the offset vector at end B in the specified frame.

16

offset2B

real

—

Component 2 of the offset vector at end B in the specified frame.

17

offset3B

real

—

Component 3 of the offset vector at end B in the specified frame.

Accepted words: OffsetsBasicGlobalGlobal, OffsetsBasicGlobalOrient, OffsetsBasicOrientGlobal, OffsetsBasicOrientOrient, OffsetsGlobalGlobalGlobal, OffsetsGlobalGlobalOrient, OffsetsGlobalOrientGlobal, OffsetsGlobalOrientOrient.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • propId — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • nodeA — the grid point IDs must be positive integers.

  • nodeB — nodeA and nodeB must be different.

  • orientationNode — orientationNode must be a positive grid point ID.

  • orientationNode — orientationNode cannot be nodeA or nodeB.

  • pinFlagsA — pinFlagsA must be digits 1 to 6 with no repeat.

  • pinFlagsB — pinFlagsB must be digits 1 to 6 with no repeat.

Example record

Bar2;1;1;1;2;0.;;0.;1.

Model containing this record

Reading the example gives id = 1, propId = 1, nodeA = 1, nodeB = 2.

Referenced records in this example

  • BarProp via propId = 1.

  • Node via nodeA = 1, nodeB = 2.

Bar2Defaults

Supplies default property, orientation and offset conventions for Bar2 elements whose corresponding fields are blank.

Record format and fields

Bar2Defaults;propId;orientation1;orientationNode;orientation2;orientation3;offsetKind

Position

Field

Type

Default

Meaning and conventions

1

propId

integer

0

Identifier of the property from which the element obtains its section or constitutive data.

2

orientation1

real

—

First component of the vector defining the element orientation. Alternative to orientationNode.

3

orientationNode

integer

—

Grid point defining the orientation direction in place of explicit vector components. Alternative to orientation1.

4

orientation2

real

0.0

Second component of the vector defining the element orientation.

5

orientation3

real

0.0

Third component of the vector defining the element orientation.

6

offsetKind

text

—

Selects the offset kind for Bar2Defaults.

Accepted words: OffsetsBasicGlobalGlobal, OffsetsBasicGlobalOrient, OffsetsBasicOrientGlobal, OffsetsBasicOrientOrient, OffsetsGlobalGlobalGlobal, OffsetsGlobalGlobalOrient, OffsetsGlobalOrientGlobal, OffsetsGlobalOrientOrient.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • propId — propId must be 0 (blank) or a property ID.

  • orientationNode — orientationNode must be a positive grid point ID.

  • orientationNode — give the orientation as a vector or as a grid point, not both.

Example record

Bar2Defaults;11;0.;;0.;1.

Model containing this record

Reading the example gives propId = 11, orientation1 = 0., orientation2 = 0., orientation3 = 1..

Referenced records in this example

Bar2Stations

Extra stations along a bar element where stresses and forces are recovered.

Record format and fields

Bar2Stations;id;stationScale;station1;stationCount;station2;station3;station4;station5;station6

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

stationScale

text

—

Scale applied at the specified station along the element.

3

station1

real

—

Position along the member or sampled path. Entry 1. Alternative to stationCount.

4

stationCount

integer

—

Number of station entries. Alternative to station1.

5

station2

real

—

Position along the member or sampled path. Entry 2.

6

station3

real

—

Position along the member or sampled path. Entry 3.

7

station4

real

—

Position along the member or sampled path. Entry 4.

8

station5

real

—

Position along the member or sampled path. Entry 5.

9

station6

real

—

Position along the member or sampled path. Entry 6.

Accepted words: ActualLength, FractionalLength.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • stationCount — the stations are listed or equally spaced, not both.

  • station1 — the card needs at least one station.

  • station6 — the card lists at most six stations.

  • station1 — the stations must be greater than 0.

Example record

Bar2Stations;1401;FractionalLength;0.25;;0.5;0.75

Model containing this record

Reading the example gives id = 1401, stationScale = FractionalLength, station1 = 0.25, station2 = 0.5.

BarArbitrarySectionProp

The arbitrary cross-section of a Bar2, described by the points of a set of GeomPoint cards.

Record format and fields

BarArbitrarySectionProp;id;matId;form;nonStructMass;description

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

3

form

text

—

Selects the form for BarArbitrarySectionProp.

4

nonStructMass

real

0.0

Additional mass distributed with the element or property; its geometric basis follows the section definition.

5

description

text

—

Free text describing this record or its output.

Accepted words: AssumedStrain, AxisymComposite, Bar, Beam, ClosedProfile, Constant, Element, GeneralSection, ImplicitHeat, ImplicitStructural, ImplicitStructuralHeat, IncompressibleSolid, Linear, LinearCubic, LinearCubicClosed, LinearCubicOpen, LinearReducedHourglass, LinearShear, Membrane, Numerical, OpenProfile, PlaneStrainComposite, Quadratic, QuadraticReduced, Rod, Smeared, Solid, SolidComposite, Table.

Example record

BarArbitrarySectionProp;12;1;ClosedProfile;;outerPerimeter=120,thickness=1.0

Model containing this record

Reading the example gives id = 12, matId = 1, form = ClosedProfile, description = outerPerimeter=120,thickness=1.0.

description contains comma-separated items: outerPerimeter=id, outerMesh=id, innerPerimeter(index)=id, branch(index)=id, thickness(index)=value, core(index)=propertyId, layer(index)=[propertyId,setId], nonStructMass=value. Thickness and core values can select points with [value,points=(startId,endId)].

Beam2

A two-node beam carrying axial force, bending moments, torsion and transverse shear. Its property describes the cross-section and its orientation defines the local bending axes.

Record format and fields

Beam2;id;propId;nodeA;nodeB;orientation1;orientationNode;orientation2;orientation3;offsetKind;pinFlagsA;pinFlagsB;offset1A;offset2A;offset3A;offset1B;offset2B;offset3B;warpingPointA;warpingPointB

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

nodeA

integer

Required

Identifier addressing node data.

4

nodeB

integer

Required

Identifier addressing node data.

5

orientation1

real

—

First component of the vector defining the element orientation. Alternative to orientationNode.

6

orientationNode

integer

—

Grid point defining the orientation direction in place of explicit vector components. Alternative to orientation1.

7

orientation2

real

0.0

Second component of the vector defining the element orientation.

8

orientation3

real

0.0

Third component of the vector defining the element orientation.

9

offsetKind

text

—

Selects the offset kind for Beam2.

10

pinFlagsA

integer

0

Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6.

11

pinFlagsB

integer

0

Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6.

12

offset1A

real

—

Component 1 of the offset vector at end A in the specified frame.

13

offset2A

real

—

Component 2 of the offset vector at end A in the specified frame.

14

offset3A

real

—

Component 3 of the offset vector at end A in the specified frame.

15

offset1B

real

—

Component 1 of the offset vector at end B in the specified frame.

16

offset2B

real

—

Component 2 of the offset vector at end B in the specified frame.

17

offset3B

real

—

Component 3 of the offset vector at end B in the specified frame.

18

warpingPointA

integer

0

Identifier addressing scalar or grid point data.

19

warpingPointB

integer

0

Identifier addressing scalar or grid point data.

Accepted words: OffsetsBasicGlobalGlobal, OffsetsBasicGlobalOrient, OffsetsBasicOrientGlobal, OffsetsBasicOrientOrient, OffsetsGlobalGlobalGlobal, OffsetsGlobalGlobalOrient, OffsetsGlobalOrientGlobal, OffsetsGlobalOrientOrient.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • nodeA — the grid point IDs must be positive integers.

  • nodeB — nodeA and nodeB must be different.

  • orientationNode — orientationNode must be a positive grid point ID.

  • orientationNode — orientationNode cannot be nodeA or nodeB.

  • pinFlagsA — pinFlagsA must be digits 1 to 6 with no repeat.

  • pinFlagsB — pinFlagsB must be digits 1 to 6 with no repeat.

  • warpingPointA — warpingPointA must be 0 or a point ID.

  • warpingPointB — warpingPointB must be 0 or a point ID.

Example record

Beam2;1;1;1;2;0.;;0.;1.

Model containing this record

Reading the example gives id = 1, propId = 1, nodeA = 1, nodeB = 2.

Referenced records in this example

  • Node via nodeA = 1, nodeB = 2.

Beam2Defaults

Supplies default property, orientation and offset conventions for Beam2 elements whose corresponding fields are blank.

Record format and fields

Beam2Defaults;propId;orientation1;orientationNode;orientation2;orientation3;offsetKind

Position

Field

Type

Default

Meaning and conventions

1

propId

integer

0

Identifier of the property from which the element obtains its section or constitutive data.

2

orientation1

real

—

First component of the vector defining the element orientation. Alternative to orientationNode.

3

orientationNode

integer

—

Grid point defining the orientation direction in place of explicit vector components. Alternative to orientation1.

4

orientation2

real

0.0

Second component of the vector defining the element orientation.

5

orientation3

real

0.0

Third component of the vector defining the element orientation.

6

offsetKind

text

—

Selects the offset kind for Beam2Defaults.

Accepted words: OffsetsBasicGlobalGlobal, OffsetsBasicGlobalOrient, OffsetsBasicOrientGlobal, OffsetsBasicOrientOrient, OffsetsGlobalGlobalGlobal, OffsetsGlobalGlobalOrient, OffsetsGlobalOrientGlobal, OffsetsGlobalOrientOrient.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • propId — propId must be 0 (blank) or a property ID.

  • orientationNode — orientationNode must be a positive grid point ID.

  • orientationNode — give the orientation as a vector or as a grid point, not both.

Example record

Beam2Defaults;31;0.;;0.;1.

Model containing this record

Reading the example gives propId = 31, orientation1 = 0., orientation2 = 0., orientation3 = 1..

Beam3

A three-node beam element (ends A and B and a middle point C).

Record format and fields

Beam3;id;propId;nodeA;nodeB;nodeC;orientationNode;orientation1;orientation2;orientation3;offset1A;offset2A;offset3A;offset1B;offset2B;offset3B;offset1C;offset2C;offset3C;twistA;twistB;twistC;warpingPointA;warpingPointB;warpingPointC

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

nodeA

integer

Required

Identifier addressing node data.

4

nodeB

integer

Required

Identifier addressing node data.

5

nodeC

integer

0

Identifier addressing node data.

6

orientationNode

integer

—

Grid point defining the orientation direction in place of explicit vector components. Alternative to orientation1.

7

orientation1

real

—

First component of the vector defining the element orientation. Alternative to orientationNode.

8

orientation2

real

0.0

Second component of the vector defining the element orientation.

9

orientation3

real

0.0

Third component of the vector defining the element orientation.

10

offset1A

real

—

Component 1 of the offset vector at end A in the specified frame.

11

offset2A

real

—

Component 2 of the offset vector at end A in the specified frame.

12

offset3A

real

—

Component 3 of the offset vector at end A in the specified frame.

13

offset1B

real

—

Component 1 of the offset vector at end B in the specified frame.

14

offset2B

real

—

Component 2 of the offset vector at end B in the specified frame.

15

offset3B

real

—

Component 3 of the offset vector at end B in the specified frame.

16

offset1C

real

—

Component 1 of the offset vector at end C in the specified frame.

17

offset2C

real

—

Component 2 of the offset vector at end C in the specified frame.

18

offset3C

real

—

Component 3 of the offset vector at end C in the specified frame.

19

twistA

real

—

Section twist at the labeled position A.

20

twistB

real

—

Section twist at the labeled position B.

21

twistC

real

—

Section twist at the labeled position C.

22

warpingPointA

integer

0

Identifier addressing scalar or grid point data.

23

warpingPointB

integer

0

Identifier addressing scalar or grid point data.

24

warpingPointC

integer

0

Identifier addressing scalar or grid point data.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • nodeA — nodeA and nodeB must be positive grid point IDs.

  • nodeC — nodeC must be 0 (blank) or a grid point ID.

  • nodeB — nodeA, nodeB and nodeC must be different.

  • orientationNode — orientationNode must be a positive grid point ID.

  • orientationNode — orientationNode cannot be nodeA, nodeB or nodeC.

  • warpingPointA — warpingPointA, warpingPointB and warpingPointC must be 0 (blank) or point IDs.

Example record

Beam3;3;3;5;6;7;;0.;0.;1.

Model containing this record

Reading the example gives id = 3, propId = 3, nodeA = 5, nodeB = 6.

Referenced records in this example

  • BeamProp3 via propId = 3.

  • Node via nodeA = 5, nodeB = 6, nodeC = 7.

BeamArbitrarySectionProp

The arbitrary cross-section of a Beam2 (or, with a Core or a Layer, of a Beam3), described by the points of a set of GeomPoint cards.

Record format and fields

BeamArbitrarySectionProp;id;matId;form;description

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

3

form

text

—

Selects the form for BeamArbitrarySectionProp.

4

description

text

—

Free text describing this record or its output.

Accepted words: AssumedStrain, AxisymComposite, Bar, Beam, ClosedProfile, Constant, Element, GeneralSection, ImplicitHeat, ImplicitStructural, ImplicitStructuralHeat, IncompressibleSolid, Linear, LinearCubic, LinearCubicClosed, LinearCubicOpen, LinearReducedHourglass, LinearShear, Membrane, Numerical, OpenProfile, PlaneStrainComposite, Quadratic, QuadraticReduced, Rod, Smeared, Solid, SolidComposite, Table.

Example record

BeamArbitrarySectionProp;51;1;GeneralSection;outerPerimeter=510

Model containing this record

Reading the example gives id = 51, matId = 1, form = GeneralSection, description = outerPerimeter=510.

description uses the same exact item names as BarArbitrarySectionProp, restricted to the items supported by this section form.

BeamPropNonlinear

The nonlinear extension of the BeamProp or BeamShapeProp with the same property ID.

Record format and fields

BeamPropNonlinear;id;matId;sectionIntegration;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

matId

integer

0

Material identifier used to retrieve the constitutive data.

3

sectionIntegration

text

—

Integration convention for recovering the section response.

Keyed sections in behaviorLines

Begin each section with its key, then write its fixed fields and any counted list.

Section TwoNodeElems

Position

Field

Type

Default

Meaning and conventions

1

behavior2

text

—

Selects the assumed response of the body or contact formulation. Entry 2.

2

integration2

text

—

Selects the rule used to integrate the element or section response. Entry 2.

Accepted words: AssumedStrain, AxisymComposite, Bar, Beam, Constant, Element, ImplicitHeat, ImplicitStructural, ImplicitStructuralHeat, IncompressibleSolid, Linear, LinearCubic, LinearCubicClosed, LinearCubicOpen, LinearReducedHourglass, LinearShear, Membrane, Numerical, PlaneStrainComposite, Quadratic, QuadraticReduced, Rod, Smeared, Solid, SolidComposite, Table, TwoNodeElems.

Example record

BeamPropNonlinear;301;;Smeared;TwoNodeElems;Beam;LinearCubic

Model containing this record

Reading the example gives id = 301, sectionIntegration = Smeared.

Bushing

A generalized spring-and-damper element.

Record format and fields

Bushing;id;propId;nodeA;nodeB;orientationNode;orientation1;orientation2;orientation3;frameId;offsetFraction;offsetFrameId;offset1;offset2;offset3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

nodeA

integer

Required

Identifier addressing node data.

4

nodeB

integer

0

Identifier addressing node data.

5

orientationNode

integer

—

Grid point defining the orientation direction in place of explicit vector components. Alternative to orientation1.

6

orientation1

real

—

First component of the vector defining the element orientation. Alternative to orientationNode.

7

orientation2

real

0.0

Second component of the vector defining the element orientation.

8

orientation3

real

0.0

Third component of the vector defining the element orientation.

9

frameId

integer

—

Coordinate system in which this entry is expressed.

10

offsetFraction

real

—

Offset expressed as a fraction of the associated reference dimension or range.

11

offsetFrameId

integer

—

Identifier addressing coordinate data.

12

offset1

real

—

Shift from the reference location or value in the convention of this entry. Entry 1.

13

offset2

real

—

Shift from the reference location or value in the convention of this entry. Entry 2.

14

offset3

real

—

Shift from the reference location or value in the convention of this entry. Entry 3.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • nodeA — nodeA must be a positive grid point ID.

  • nodeB — nodeB must be 0 (blank) or a grid point ID.

  • nodeB — nodeA and nodeB must be different.

  • orientationNode — orientationNode must be a positive grid point ID.

  • frameId — frameId must be blank or a coordinate system ID.

  • offsetFrameId — offsetFrameId must be -1 or a coordinate system ID.

Example record

Bushing;101;101;101;102;;0.;1.;0.

Model containing this record

Reading the example gives id = 101, propId = 101, nodeA = 101, nodeB = 102.

Referenced records in this example

  • BushProp via propId = 101.

  • Node via nodeA = 101, nodeB = 102.

Bushing1D

A rod-type spring and damper between two grid points.

Record format and fields

Bushing1D;id;propId;nodeA;nodeB;frameId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

nodeA

integer

Required

Identifier addressing node data.

4

nodeB

integer

0

Identifier addressing node data.

5

frameId

integer

—

Coordinate system in which this entry is expressed.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • nodeA — nodeA must be a positive grid point ID.

  • nodeB — nodeB must be 0 (blank) or a grid point ID.

  • nodeB — nodeA and nodeB must be different.

  • frameId — frameId must be blank or a coordinate system ID.

Example record

Bushing1D;54;54;10;26

Model containing this record

Reading the example gives id = 54, propId = 54, nodeA = 10, nodeB = 26.

Bushing2D

Models an in-plane connection between the inner and outer grid points of a bearing or bushing.

Record format and fields

Bushing2D;id;propId;nodeA;nodeB;frameId;plane

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

nodeA

integer

—

Grid point identifier at connectivity position A.

4

nodeB

integer

—

Grid point identifier at connectivity position B.

5

frameId

integer

0

Coordinate system in which this entry is expressed.

6

plane

text

—

Reference plane used for the geometric definition.

Accepted words: Constant, Element, PlaneXy, PlaneYz, PlaneZx, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • frameId — the coordinate system ID frameId must not be negative.

Example record

Bushing2D;1;21;1;2;0;PlaneXy

Model containing this record

Reading the example gives id = 1, propId = 21, nodeA = 1, nodeB = 2.

CohesiveAxisymQuad

A linear or quadratic axisymmetric cohesive interface element with four to eight nodes, used to simulate the onset and growth of a delamination between two axisymmetric bodies.

Record format and fields

CohesiveAxisymQuad;id;propId;node1;node2;node3;node4;node5;node6;node7;node8

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

node5

integer

—

Grid point to which this entry applies. Entry 5.

8

node6

integer

—

Grid point to which this entry applies. Entry 6.

9

node7

integer

—

Grid point to which this entry applies. Entry 7.

10

node8

integer

—

Grid point to which this entry applies. Entry 8.

Accepted words: Constant, Element, Table.

Example record

CohesiveAxisymQuad;3;5;4;5;8;7

Model containing this record

Reading the example gives id = 3, propId = 5, node1 = 4, node2 = 5.

Referenced records in this example

CohesiveHexa

A linear or quadratic three-dimensional cohesive interface element with eight to twenty nodes, used to simulate the onset and growth of a delamination between two bodies.

Record format and fields

CohesiveHexa;id;propId;node1;node2;node3;node4;node5;node6;node7;node8;node9;node10;node11;node12;node13;node14;node15;node16;node17;node18;node19;node20

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

node5

integer

—

Grid point to which this entry applies. Entry 5.

8

node6

integer

—

Grid point to which this entry applies. Entry 6.

9

node7

integer

—

Grid point to which this entry applies. Entry 7.

10

node8

integer

—

Grid point to which this entry applies. Entry 8.

11

node9

integer

—

Grid point to which this entry applies. Entry 9.

12

node10

integer

—

Grid point to which this entry applies. Entry 10.

13

node11

integer

—

Grid point to which this entry applies. Entry 11.

14

node12

integer

—

Grid point to which this entry applies. Entry 12.

15

node13

integer

—

Grid point to which this entry applies. Entry 13.

16

node14

integer

—

Grid point to which this entry applies. Entry 14.

17

node15

integer

—

Grid point to which this entry applies. Entry 15.

18

node16

integer

—

Grid point to which this entry applies. Entry 16.

19

node17

integer

—

Grid point to which this entry applies. Entry 17.

20

node18

integer

—

Grid point to which this entry applies. Entry 18.

21

node19

integer

—

Grid point to which this entry applies. Entry 19.

22

node20

integer

—

Grid point to which this entry applies. Entry 20.

Accepted words: Constant, Element, Table.

Example record

CohesiveHexa;102;5;105;106;107;108;109;110;111;112

Model containing this record

Reading the example gives id = 102, propId = 5, node1 = 105, node2 = 106.

Referenced records in this example

CohesiveMat

The material of the interface cohesive zone elements that simulate the onset and the growth of a delamination.

Record format and fields

CohesiveMat;id;cohesiveModel;tableId;cohesiveEnergy;criticalOpening;maxOpening;shearNormalStressRatio;exponent;viscousDissipation;referenceDisplacementRate;compressionStiffening;shearNormalEnergyRatio;inPlaneStiffness;normalStiffness

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the material namespace.

2

cohesiveModel

integer

—

A TableStress1 or TableStressTemperature of cohesive energy against temperature, 0 for none.

3

tableId

integer

0

Identifier of the tabulated function to evaluate.

4

cohesiveEnergy

real

—

Energy associated with separation of the cohesive interface.

5

criticalOpening

real

—

Critical opening distance.

6

maxOpening

real

—

Maximum opening displacement.

7

shearNormalStressRatio

real

1.0

Relative measure of shear normal stress.

8

exponent

real

1.0

Power applied to the associated variable in the stated relation.

9

viscousDissipation

real

0.0

Factor of viscous energy dissipation.

10

referenceDisplacementRate

real

0.0

Reference rate of relative displacement, 0.0 computes it.

11

compressionStiffening

real

1.0

Stiffening factor in compression.

12

shearNormalEnergyRatio

real

1.0

Relative measure of shear normal energy.

13

inPlaneStiffness

real

0.0

Stiffness in the plane of the element (linear solutions).

14

normalStiffness

real

0.0

Stiffness normal to the plane of the element (linear solutions).

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • cohesiveModel — cohesiveModel must be 1, 2, 3, -1 or -2.

Example record

CohesiveMat;5;1;;0.5;0.002;0.02;1.

Model containing this record

Reading the example gives id = 5, cohesiveModel = 1, cohesiveEnergy = 0.5, criticalOpening = 0.002.

CohesivePenta

A linear or quadratic three-dimensional cohesive interface element with six to fifteen nodes (a wedge), used to simulate the onset and growth of a delamination between two bodies.

Record format and fields

CohesivePenta;id;propId;node1;node2;node3;node4;node5;node6;node7;node8;node9;node10;node11;node12;node13;node14;node15

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

node5

integer

—

Grid point to which this entry applies. Entry 5.

8

node6

integer

—

Grid point to which this entry applies. Entry 6.

9

node7

integer

—

Grid point to which this entry applies. Entry 7.

10

node8

integer

—

Grid point to which this entry applies. Entry 8.

11

node9

integer

—

Grid point to which this entry applies. Entry 9.

12

node10

integer

—

Grid point to which this entry applies. Entry 10.

13

node11

integer

—

Grid point to which this entry applies. Entry 11.

14

node12

integer

—

Grid point to which this entry applies. Entry 12.

15

node13

integer

—

Grid point to which this entry applies. Entry 13.

16

node14

integer

—

Grid point to which this entry applies. Entry 14.

17

node15

integer

—

Grid point to which this entry applies. Entry 15.

Accepted words: Constant, Element, Table.

Example record

CohesivePenta;202;5;204;205;206;207;208;209

Model containing this record

Reading the example gives id = 202, propId = 5, node1 = 204, node2 = 205.

Referenced records in this example

CohesiveProp

The property of the interface cohesive zone elements (CohesiveQuad, CohesiveHexa, CohesivePenta and CohesiveAxisymQuad), which simulate the onset and growth of a delamination.

Record format and fields

CohesiveProp;id;matId;integration;thickness;output;tangentStiffness

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

3

integration

integer

—

Selects the rule used to integrate the element or section response.

4

thickness

real

1.0

Through-thickness dimension, in model length units.

5

output

text

—

Controls the information recovered or written for this entry.

6

tangentStiffness

integer

0

Local slope of the force–displacement relation at the current state.

Accepted words: Constant, Element, GaussPoints, Nodes, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • integration — integration must be 0 (Gauss) or 1 (Newton-Cotes/Lobatto).

  • tangentStiffness — tangentStiffness must be 0 (secant matrix) or 1 (tangent matrix).

Example record

CohesiveProp;5;5;0;1.;Nodes;0

Model containing this record

Reading the example gives id = 5, matId = 5, integration = 0, thickness = 1..

CohesiveQuad

A linear or quadratic planar cohesive interface element with four to eight nodes, used to simulate the onset and growth of a delamination between two bodies in plane strain or plane stress.

Record format and fields

CohesiveQuad;id;propId;node1;node2;node3;node4;node5;node6;node7;node8

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

node5

integer

—

Grid point to which this entry applies. Entry 5.

8

node6

integer

—

Grid point to which this entry applies. Entry 6.

9

node7

integer

—

Grid point to which this entry applies. Entry 7.

10

node8

integer

—

Grid point to which this entry applies. Entry 8.

Accepted words: Constant, Element, Table.

Example record

CohesiveQuad;3;5;4;5;8;7

Model containing this record

Reading the example gives id = 3, propId = 5, node1 = 4, node2 = 5.

Referenced records in this example

ConicalShellProp

The property of the conical shell elements (ShellConical2).

Record format and fields

ConicalShellProp;id;matId1;thickness1;matId2;inertia;matId3;thickness2;nonStructMass;fiberDistance1;fiberDistance2;<phiAngles>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId1

integer

0

Identifier addressing material data.

3

thickness1

real

0.0

Through-thickness dimension, in model length units. Entry 1.

4

matId2

integer

0

Identifier addressing material data.

5

inertia

real

0.0

Moment of inertia per unit width.

6

matId3

integer

0

Identifier addressing material data.

7

thickness2

real

0.0

Through-thickness dimension, in model length units. Entry 2.

8

nonStructMass

real

0.0

Additional mass distributed with the element or property; its geometric basis follows the section definition.

9

fiberDistance1

real

—

Fiber distance 1 (length).

10

fiberDistance2

real

—

Fiber distance 2 (length).

Repeated group phiAngles. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

phiAngle

real

—

Angular coordinate or orientation denoted by phi in the local geometry.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the property ID must be a positive integer.

  • matId1 — the material IDs must not be negative.

  • thickness1 — matId1 and thickness1 must both be given or both be zero or blank.

  • inertia — matId2 and inertia must both be given or both be zero or blank.

  • thickness2 — matId3 and thickness2 must both be given or both be zero or blank.

  • thickness1 — the thicknesses thickness1 and thickness2 must not be negative.

  • phiAngle — the card has at most 14 azimuthal coordinates phiAngle.

Example record

ConicalShellProp;1;1;2.;1;0.6667;1;1.6667;;1.;-1.;0.;90.

Model containing this record

Reading the example gives id = 1, matId1 = 1, thickness1 = 2., matId2 = 1.

Referenced records in this example

  • IsoMat via matId1 = 1, matId2 = 1, matId3 = 1.

ConnectorSearchControl

Values of the parameters of the connector search that apply to a group of connector elements (Fastener, Seam, Weld) and override the ones of the ConnectorSearchParams card for them.

Record format and fields

ConnectorSearchControl;elementSetId;<parameters>

Position

Field

Type

Default

Meaning and conventions

1

elementSetId

integer

Required

Identifier selecting the element set record or set.

Repeated group parameters. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

number

—

Value assigned to the named parameter. Its interpretation depends on that name.

Accepted words: ConnectorSearchParams, Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • parameterName1 — the card needs at least one parameter and its value.

Example record

ConnectorSearchControl;71;ProjectionTolerance;0.05;MaxEndPointMoves;3;GeneratedDataPrint;1

Model containing this record

Reading the example gives elementSetId = 71.

ConnectorSearchParams

Sets named search controls for finding the surfaces joined by Fastener, Weld and Seam elements.

Record format and fields

ConnectorSearchParams;<globalParameters>;<keyed sections>

This part of the record has no fixed fields.

Repeated group globalParameters. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

number

—

Value assigned to the named parameter. Its interpretation depends on that name.

Keyed sections in connectorSections

Begin each section with its key, then write its fixed fields and any counted list.

Section Fastener

Repeated group parameters. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

sectionParameterName

text

—

Text naming the section parameter.

2

sectionParameterValue

number

—

Value associated with the selected section parameter.

Section Weld

Repeated group parameters. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

sectionParameterName

text

—

Text naming the section parameter.

2

sectionParameterValue

number

—

Value associated with the selected section parameter.

Section Seam

Repeated group parameters. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

sectionParameterName

text

—

Text naming the section parameter.

2

sectionParameterValue

number

—

Value associated with the selected section parameter.

Accepted words: Constant, Element, Fastener, Seam, Table, Weld.

Accepted parameter names: DiagnosticTableUnit, GeneratedDataPrint, GeometryCheckLevel, MaxDiameterHalvings, MaxEndPointMoves, MaxProjectionDistance, MaxShellNormalAngle, MoveEndPointsToProjection, PatchDiameterFactor, PatchStiffnessFactor, ProjectionTolerance, ProjectionToleranceSwitches, SeamEndMaxNormalAngle, SeamEndMinEdgeAngle, StopAfterConnectivityCheck, WeldMass.

Example record

ConnectorSearchParams;3;MaxShellNormalAngle;20.;ProjectionTolerance;0.02;MaxEndPointMoves;2

Model containing this record

CrackTip2D

Represents a two-dimensional crack-tip element associated with UserDefined8Attributes.

Record format and fields

CrackTip2D;id;propId;node1;node2;node3;node4;node5;node6;node7;node8;node9;node10;node11;node12;node13;node14;node15;node16;node17;node18

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

node5

integer

—

Grid point to which this entry applies. Entry 5.

8

node6

integer

—

Grid point to which this entry applies. Entry 6.

9

node7

integer

—

Grid point to which this entry applies. Entry 7.

10

node8

integer

—

Grid point to which this entry applies. Entry 8.

11

node9

integer

—

Grid point to which this entry applies. Entry 9.

12

node10

integer

—

Grid point to which this entry applies. Entry 10.

13

node11

integer

—

Grid point to which this entry applies. Entry 11.

14

node12

integer

—

Grid point to which this entry applies. Entry 12.

15

node13

integer

—

Grid point to which this entry applies. Entry 13.

16

node14

integer

—

Grid point to which this entry applies. Entry 14.

17

node15

integer

—

Grid point to which this entry applies. Entry 15.

18

node16

integer

—

Grid point to which this entry applies. Entry 16.

19

node17

integer

—

Grid point to which this entry applies. Entry 17.

20

node18

integer

—

Grid point to which this entry applies. Entry 18.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be an integer from 1 to 99999999.

  • propId — the property ID must be a positive integer.

Example record

CrackTip2D;10;1;1;2;3;4;5;6;7

Model containing this record

Reading the example gives id = 10, propId = 1, node1 = 1, node2 = 2.

Referenced records in this example

  • CrackTipProp2D via propId = 1.

  • Node via node1 = 1, node2 = 2, node3 = 3, node4 = 4, node5 = 5, node6 = 6, node7 = 7.

CrackTip3D

Represents a three-dimensional crack-tip element associated with UserDefined9Attributes.

Record format and fields

CrackTip3D;id;propId;node1;node2;node3;node4;node5;node6;node7;node8;node9;node10;node11;node12;node13;node14;node15;node16;node17;node18;node19;node20;node21;node22;node23;node24;node25;node26;node27;node28;node29;node30;node31;node32;node33;node34;node35;node36;node37;node38;node39;node40;node41;node42;node43;node44;node45;node46;node47;node48;node49;node50;node51;node52;node53;node54;node55;node56;node57;node58;node59;node60;node61;node62;node63;node64

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

node5

integer

—

Grid point to which this entry applies. Entry 5.

8

node6

integer

—

Grid point to which this entry applies. Entry 6.

9

node7

integer

—

Grid point to which this entry applies. Entry 7.

10

node8

integer

—

Grid point to which this entry applies. Entry 8.

11

node9

integer

—

Grid point to which this entry applies. Entry 9.

12

node10

integer

—

Grid point to which this entry applies. Entry 10.

13

node11

integer

—

Grid point to which this entry applies. Entry 11.

14

node12

integer

—

Grid point to which this entry applies. Entry 12.

15

node13

integer

—

Grid point to which this entry applies. Entry 13.

16

node14

integer

—

Grid point to which this entry applies. Entry 14.

17

node15

integer

—

Grid point to which this entry applies. Entry 15.

18

node16

integer

—

Grid point to which this entry applies. Entry 16.

19

node17

integer

—

Grid point to which this entry applies. Entry 17.

20

node18

integer

—

Grid point to which this entry applies. Entry 18.

21

node19

integer

—

Grid point to which this entry applies. Entry 19.

22

node20

integer

—

Grid point to which this entry applies. Entry 20.

23

node21

integer

—

Grid point to which this entry applies. Entry 21.

24

node22

integer

—

Grid point to which this entry applies. Entry 22.

25

node23

integer

—

Grid point to which this entry applies. Entry 23.

26

node24

integer

—

Grid point to which this entry applies. Entry 24.

27

node25

integer

—

Grid point to which this entry applies. Entry 25.

28

node26

integer

—

Grid point to which this entry applies. Entry 26.

29

node27

integer

—

Grid point to which this entry applies. Entry 27.

30

node28

integer

—

Grid point to which this entry applies. Entry 28.

31

node29

integer

—

Grid point to which this entry applies. Entry 29.

32

node30

integer

—

Grid point to which this entry applies. Entry 30.

33

node31

integer

—

Grid point to which this entry applies. Entry 31.

34

node32

integer

—

Grid point to which this entry applies. Entry 32.

35

node33

integer

—

Grid point to which this entry applies. Entry 33.

36

node34

integer

—

Grid point to which this entry applies. Entry 34.

37

node35

integer

—

Grid point to which this entry applies. Entry 35.

38

node36

integer

—

Grid point to which this entry applies. Entry 36.

39

node37

integer

—

Grid point to which this entry applies. Entry 37.

40

node38

integer

—

Grid point to which this entry applies. Entry 38.

41

node39

integer

—

Grid point to which this entry applies. Entry 39.

42

node40

integer

—

Grid point to which this entry applies. Entry 40.

43

node41

integer

—

Grid point to which this entry applies. Entry 41.

44

node42

integer

—

Grid point to which this entry applies. Entry 42.

45

node43

integer

—

Grid point to which this entry applies. Entry 43.

46

node44

integer

—

Grid point to which this entry applies. Entry 44.

47

node45

integer

—

Grid point to which this entry applies. Entry 45.

48

node46

integer

—

Grid point to which this entry applies. Entry 46.

49

node47

integer

—

Grid point to which this entry applies. Entry 47.

50

node48

integer

—

Grid point to which this entry applies. Entry 48.

51

node49

integer

—

Grid point to which this entry applies. Entry 49.

52

node50

integer

—

Grid point to which this entry applies. Entry 50.

53

node51

integer

—

Grid point to which this entry applies. Entry 51.

54

node52

integer

—

Grid point to which this entry applies. Entry 52.

55

node53

integer

—

Grid point to which this entry applies. Entry 53.

56

node54

integer

—

Grid point to which this entry applies. Entry 54.

57

node55

integer

—

Grid point to which this entry applies. Entry 55.

58

node56

integer

—

Grid point to which this entry applies. Entry 56.

59

node57

integer

—

Grid point to which this entry applies. Entry 57.

60

node58

integer

—

Grid point to which this entry applies. Entry 58.

61

node59

integer

—

Grid point to which this entry applies. Entry 59.

62

node60

integer

—

Grid point to which this entry applies. Entry 60.

63

node61

integer

—

Grid point to which this entry applies. Entry 61.

64

node62

integer

—

Grid point to which this entry applies. Entry 62.

65

node63

integer

—

Grid point to which this entry applies. Entry 63.

66

node64

integer

—

Grid point to which this entry applies. Entry 64.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be an integer from 1 to 99999999.

  • propId — the property ID must be a positive integer.

Example record

CrackTip3D;20;2;101;102;103;104;105;106;107;;;;;;;;;;;;119;120;121;122;123;124;125

Model containing this record

Reading the example gives id = 20, propId = 2, node1 = 101, node2 = 102.

Referenced records in this example

  • CrackTipProp3D via propId = 2.

  • Node via node1 = 101, node2 = 102, node3 = 103, node4 = 104, node5 = 105, node6 = 106, node7 = 107, node19 = 119, node20 = 120, node21 = 121, node22 = 122, node23 = 123, node24 = 124, node25 = 125.

CrackTipProp2D

The property of a CrackTip2D crack tip element.

Record format and fields

CrackTipProp2D;id;matId;thickness;planeCondition;nonStructMass;gammaCoefficient;phiAngle

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

3

thickness

real

Required

Through-thickness dimension, in model length units.

4

planeCondition

integer

—

Selects the in-plane kinematic or stress assumption.

5

nonStructMass

real

0.0

Additional mass distributed with the element or property; its geometric basis follows the section definition.

6

gammaCoefficient

real

—

Coefficient in the relation for gamma.

7

phiAngle

real

—

Angular coordinate or orientation denoted by phi in the local geometry.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • planeCondition — planeCondition must be 0 (plane strain) or 1 (plane stress).

Example record

CrackTipProp2D;1;1;1.;0

Model containing this record

Reading the example gives id = 1, matId = 1, thickness = 1., planeCondition = 0.

Referenced records in this example

CrackTipProp3D

The property of a CrackTip3D crack tip element.

Record format and fields

CrackTipProp3D;id;matId;gammaCoefficient;phiAngle

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

3

gammaCoefficient

real

—

Coefficient in the relation for gamma.

4

phiAngle

real

—

Angular coordinate or orientation denoted by phi in the local geometry.

Accepted words: Constant, Element, Table.

Example record

CrackTipProp3D;2;1

Model containing this record

Reading the example gives id = 2, matId = 1.

Referenced records in this example

CurvedBeam2

A curved beam, curved pipe or elbow element between two grid points.

Record format and fields

CurvedBeam2;id;propId;nodeA;nodeB;orientationNode;orientation1;orientation2;orientation3;geometryOption

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

nodeA

integer

Required

Identifier addressing node data.

4

nodeB

integer

Required

Identifier addressing node data.

5

orientationNode

integer

—

Grid point defining the orientation direction in place of explicit vector components. Alternative to orientation1.

6

orientation1

real

—

First component of the vector defining the element orientation. Alternative to orientationNode.

7

orientation2

real

0.0

Second component of the vector defining the element orientation.

8

orientation3

real

0.0

Third component of the vector defining the element orientation.

9

geometryOption

integer

Required

Selects the geometry option for CurvedBeam2.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • nodeA — the grid point IDs must be positive integers.

  • nodeB — nodeA and nodeB must be different.

  • orientationNode — orientationNode must be a positive grid point ID.

  • orientationNode — orientationNode cannot be nodeA or nodeB.

  • geometryOption — geometryOption must be an integer from 1 to 4.

Example record

CurvedBeam2;10;4;11;12;;0.;1.;0.;1

Model containing this record

Reading the example gives id = 10, propId = 4, nodeA = 11, nodeB = 12.

Referenced records in this example

  • Node via nodeA = 11, nodeB = 12.

DamperDofInline

A scalar damper that holds its own damping (no property).

Record format and fields

DamperDofInline;id;damping;node1;components1;node2;components2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

damping

real

Required

Dissipative coefficient of the selected connection, material or response law.

3

node1

integer

0

Identifier addressing scalar or grid point data.

4

components1

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1.

5

node2

integer

0

Identifier addressing scalar or grid point data.

6

components2

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • node1 — the point IDs must not be negative.

  • components1 — components1 must be a component from 0 to 6.

  • components2 — components2 must be a component from 0 to 6.

Example record

DamperDofInline;55;0.5;15;3;23;3

Model containing this record

Reading the example gives id = 55, damping = 0.5, node1 = 15, components1 = 3.

DamperDofInlineExplicit

The scalar damper that holds its own damping (no property), with the coordinate system its direction is given in.

Record format and fields

DamperDofInlineExplicit;id;damping;node1;components1;node2;components2;frameId;follow

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

damping

real

Required

Dissipative coefficient of the selected connection, material or response law.

3

node1

integer

0

Identifier addressing scalar or grid point data.

4

components1

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1.

5

node2

integer

0

Identifier addressing scalar or grid point data.

6

components2

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2.

7

frameId

integer

0

Coordinate system in which this entry is expressed.

8

follow

text

—

Specifies whether the direction or attachment follows the changing configuration.

Accepted words: Constant, CoordinateFrame, Element, Follow, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • node1 — the point ID node1 must not be negative.

  • components1 — components1 must be 0 or a list of the digits 1 to 6, each at most once.

  • node2 — the point ID node2 must not be negative.

  • components2 — components2 must be 0 or a list of the digits 1 to 6, each at most once.

  • frameId — the coordinate system ID must not be negative.

Example record

DamperDofInlineExplicit;4003;0.005;3012;3

Model containing this record

Reading the example gives id = 4003, damping = 0.005, node1 = 3012, components1 = 3.

DamperDofProperty

A scalar damper that refers to a DamperProp property.

Record format and fields

DamperDofProperty;id;propId;node1;components1;node2;components2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

0

Identifier addressing scalar or grid point data.

4

components1

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1.

5

node2

integer

0

Identifier addressing scalar or grid point data.

6

components2

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the point IDs must not be negative.

  • components1 — components1 must be a component from 0 to 6.

  • components2 — components2 must be a component from 0 to 6.

Example record

DamperDofProperty;102;12;102;1;101;1

Model containing this record

Reading the example gives id = 102, propId = 12, node1 = 102, components1 = 1.

DamperDofPropertyExplicit

The scalar damper that names a property, with the coordinate system its direction is given in.

Record format and fields

DamperDofPropertyExplicit;id;propId;node1;components1;node2;components2;frameId;follow

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

0

Identifier addressing scalar or grid point data.

4

components1

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1.

5

node2

integer

0

Identifier addressing scalar or grid point data.

6

components2

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2.

7

frameId

integer

0

Coordinate system in which this entry is expressed.

8

follow

text

—

Specifies whether the direction or attachment follows the changing configuration.

Accepted words: CoordinateFrame, Follow.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the point ID node1 must not be negative.

  • components1 — components1 must be 0 or a list of the digits 1 to 6, each at most once.

  • node2 — the point ID node2 must not be negative.

  • components2 — components2 must be 0 or a list of the digits 1 to 6, each at most once.

  • frameId — the coordinate system ID must not be negative.

Example record

DamperDofPropertyExplicit;4004;4104;3013;3;3023;3

Model containing this record

Reading the example gives id = 4004, propId = 4104, node1 = 3013, components1 = 3.

DamperScalarInline

A scalar damper between two scalar points, with its own damping (no property).

Record format and fields

DamperScalarInline;id;damping;scalarPoint1;scalarPoint2;id2;damping2;scalarPoint3;scalarPoint4

Position

Field

Type

Default

Meaning and conventions

1

id

integer

—

Identifier in the element namespace.

2

damping

real

—

Dissipative coefficient of the selected connection, material or response law.

3

scalarPoint1

integer

0

Identifier addressing scalar or grid point data.

4

scalarPoint2

integer

0

Identifier addressing scalar or grid point data.

5

id2

integer

—

Identifier at position 2 in the ordered DamperScalarInline data.

6

damping2

real

—

Dissipative coefficient of the selected connection, material or response law. Entry 2.

7

scalarPoint3

integer

0

Scalar point at position 3 in the ordered connection.

8

scalarPoint4

integer

0

Scalar point at position 4 in the ordered connection.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • scalarPoint1 — the scalar point IDs must not be negative.

  • scalarPoint1 — scalarPoint1 and scalarPoint2 cannot both be blank or zero.

  • scalarPoint2 — the two scalar points must be different.

Example record

DamperScalarInline;1808;0.2;1804

Model containing this record

Reading the example gives id = 1808, damping = 0.2, scalarPoint1 = 1804.

DamperScalarProperty

A scalar damper between two scalar points, with a DamperProp property.

Record format and fields

DamperScalarProperty;id;propId;scalarPoint1;scalarPoint2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

scalarPoint1

integer

0

Identifier addressing scalar or grid point data.

4

scalarPoint2

integer

0

Identifier addressing scalar or grid point data.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • scalarPoint1 — the scalar point IDs must not be negative.

  • scalarPoint2 — the two scalar points must be different.

Example record

DamperScalarProperty;1807;187;1803;1804

Model containing this record

Reading the example gives id = 1807, propId = 187, scalarPoint1 = 1803, scalarPoint2 = 1804.

ElemGeneration

Defines how elements are generated from a field of grid points.

Record format and fields

ElemGeneration;kind;firstElemId;propId;gridFieldId;direction;thicknessOption;lowElemId;highElemId;valueA;valueB;valueC;valueD

Position

Field

Type

Default

Meaning and conventions

1

kind

text

—

Selects the kind for ElemGeneration.

2

firstElemId

integer

Required

Identifier selecting the first element record or set.

3

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

4

gridFieldId

integer

Required

Identifier selecting the grid field record or set.

5

direction

any

—

Orientation in which the specified quantity acts or is measured.

6

thicknessOption

any

—

Selects the thickness option for ElemGeneration.

7

lowElemId

any

—

Identifier selecting the low element record or set.

8

highElemId

any

—

Identifier selecting the high element record or set.

9

valueA

any

—

Specified value at the labeled position A.

10

valueB

any

—

Specified value at the labeled position B.

11

valueC

any

—

Specified value at the labeled position C.

12

valueD

any

—

Specified value at the labeled position D.

Accepted words: Constant, Element, Hexa20, Hexa8, Quad4, Quad8, Table, Tria3, Tria6.

Example record

ElemGeneration;Quad4;21;1;31

Model containing this record

Reading the example gives kind = Quad4, firstElemId = 21, propId = 1, gridFieldId = 31.

Fastener

A fastener between two surface patches.

Record format and fields

Fastener;id;propId;kind;patchIdA;patchIdB;spotNode;nodeA;nodeB;locationX;locationY;locationZ

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

kind

text

—

Selects the kind for Fastener.

4

patchIdA

integer

Required

Identifier of the patch on side A.

5

patchIdB

integer

Required

Identifier of the patch on side B.

6

spotNode

integer

0

Identifier addressing node data.

7

nodeA

integer

0

Identifier addressing node data.

8

nodeB

integer

0

Identifier addressing node data.

9

locationX

real

—

X coordinate of the location.

10

locationY

real

—

Y coordinate of the location.

11

locationZ

real

—

Z coordinate of the location.

Accepted words: Elements, Property.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • kind — kind must be Property or Elements.

  • patchIdA — patchIdA and patchIdB must be positive integers.

  • spotNode — spotNode, nodeA and nodeB must be 0 (blank) or grid point IDs.

  • locationX — locationX, locationY and locationZ must be all given or all blank.

Example record

Fastener;2001;1;Elements;1;101;951

Model containing this record

Reading the example gives id = 2001, propId = 1, kind = Elements, patchIdA = 1.

Referenced records in this example

Gap2

A gap or friction element between two grid points.

Record format and fields

Gap2;id;propId;nodeA;nodeB;orientationNode;orientation1;orientation2;orientation3;frameId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

nodeA

integer

Required

Identifier addressing node data.

4

nodeB

integer

Required

Identifier addressing node data.

5

orientationNode

integer

—

Grid point defining the orientation direction in place of explicit vector components. Alternative to orientation1.

6

orientation1

real

—

First component of the vector defining the element orientation. Alternative to orientationNode.

7

orientation2

real

0.0

Second component of the vector defining the element orientation.

8

orientation3

real

0.0

Third component of the vector defining the element orientation.

9

frameId

integer

—

Coordinate system in which this entry is expressed.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • nodeA — the grid point IDs must be positive integers.

  • nodeB — nodeA and nodeB must be different.

  • orientationNode — orientationNode must be a positive grid point ID.

  • frameId — frameId must be blank or a coordinate system ID.

Example record

Gap2;5;5;9;10;;0.;1.;0.

Model containing this record

Reading the example gives id = 5, propId = 5, nodeA = 9, nodeB = 10.

Referenced records in this example

  • GapProp via propId = 5.

  • Node via nodeA = 9, nodeB = 10.

GeneralMatrix

Defines an element by a stiffness or flexibility matrix over an ordered set of independent degrees of freedom. A separate matrix can relate a dependent set to them.

Record format and fields

GeneralMatrix;id;<independentDofs>;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

Repeated group independentDofs. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

independentPoint

integer

—

Point associated with the independent degree of freedom.

2

independentComponent

integer

—

Degree of freedom contributing to the dependent motion.

Keyed sections in parts

Begin each section with its key, then write its fixed fields and any counted list.

Section DependentDofs

Repeated group dependentDofs. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

dependentPoint

integer

—

Point associated with the dependent degree of freedom.

2

dependentComponent

integer

—

Degree of freedom to be recovered from the independent motions.

Section Stiffness

Repeated group stiffnessMatrix. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

stiffness

real

—

One term in the lower triangle of the stiffness matrix. Terms are ordered down each column.

Section Flexibility

Repeated group flexibilityMatrix. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

stiffness

real

—

One term in the lower triangle of the stiffness matrix. Terms are ordered down each column.

Section Dependency

Repeated group dependencyMatrix. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

dependencyMatrix

real

—

Coefficient relating the independent set to the dependent set. This matrix is entered by rows.

Accepted words: Dependency, DependentDofs, Flexibility, Stiffness.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • independentPoint — independentPoint must be a point ID and independentComponent a component from 0 to 6.

  • dependentPoint — dependentPoint must be a point ID and dependentComponent a component from 0 to 6.

Example record

GeneralMatrix;103;3;102;1;102;2;102;3;DependentDofs;6;101;1;101;2;101;3;101;4;101;5;101;6;Stiffness;6;1.E+3;0.;0.;2.E+3;0.;3.E+3

Model containing this record

Reading the example gives id = 103.

HeatCapacity2

A damper (heat capacity, for heat transfer analysis) between two points, with a HeatCapacityProp5 property.

Record format and fields

HeatCapacity2;id;propId;node1;node2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

0

Identifier addressing scalar or grid point data.

4

node2

integer

0

Identifier addressing scalar or grid point data.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the point IDs must not be negative.

  • node2 — the two points must be different.

Example record

HeatCapacity2;202;2;2

Model containing this record

Reading the example gives id = 202, propId = 2, node1 = 2.

Referenced records in this example

LineInterface

An interface ties at least two geometric boundary curves together.

Record format and fields

LineInterface;id;kind;boundaryList

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

kind

text

—

Selects the kind for LineInterface.

3

boundaryList

text

—

Identifier addressing geometric boundary data. Written as one text field.

Accepted words: Constant, Element, Linear, NodeList, Quadratic, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • boundaryList — the card needs at least two boundaries in its boundaryList.

Example record

LineInterface;431;NodeList;boundaries=(1,2)

Model containing this record

Reading the example gives id = 431, kind = NodeList, boundaryList = boundaries=(1,2).

boundaryList is boundaries=(id, id(Linear), id(Quadratic), …). A bare ID uses Linear interpolation; the sign identifies an independent boundary. All names use exact case.

MassDofInline

A scalar mass element that holds its own mass value (no property).

Record format and fields

MassDofInline;id;mass;node1;components1;node2;components2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

mass

real

Required

Inertial mass associated with the selected component or body.

3

node1

integer

0

Identifier addressing scalar or grid point data.

4

components1

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1.

5

node2

integer

0

Identifier addressing scalar or grid point data.

6

components2

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • node1 — the point IDs must not be negative.

  • components1 — components1 must be a component from 0 to 6.

  • components2 — components2 must be a component from 0 to 6.

Example record

MassDofInline;504;0.004;503;5

Model containing this record

Reading the example gives id = 504, mass = 0.004, node1 = 503, components1 = 5.

MassDofProperty

A scalar mass element that refers to a MassProp property.

Record format and fields

MassDofProperty;id;propId;node1;components1;node2;components2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

0

Identifier addressing scalar or grid point data.

4

components1

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1.

5

node2

integer

0

Identifier addressing scalar or grid point data.

6

components2

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the point IDs must not be negative.

  • components1 — components1 must be a component from 0 to 6.

  • components2 — components2 must be a component from 0 to 6.

Example record

MassDofProperty;502;8;503;5

Model containing this record

Reading the example gives id = 502, propId = 8, node1 = 503, components1 = 5.

MassScalarInline

A scalar mass element between two scalar points, with its own mass value (no property).

Record format and fields

MassScalarInline;id;mass;scalarPoint1;scalarPoint2;id2;mass2;scalarPoint3;scalarPoint4

Position

Field

Type

Default

Meaning and conventions

1

id

integer

—

Identifier in the element namespace.

2

mass

real

—

Inertial mass associated with the selected component or body.

3

scalarPoint1

integer

0

Identifier addressing scalar or grid point data.

4

scalarPoint2

integer

0

Identifier addressing scalar or grid point data.

5

id2

integer

—

Identifier at position 2 in the ordered MassScalarInline data.

6

mass2

real

—

Inertial mass associated with the selected component or body. Entry 2.

7

scalarPoint3

integer

0

Scalar point at position 3 in the ordered connection.

8

scalarPoint4

integer

0

Scalar point at position 4 in the ordered connection.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • scalarPoint1 — the scalar point IDs must not be negative.

  • scalarPoint1 — scalarPoint1 and scalarPoint2 cannot both be blank or zero.

  • scalarPoint2 — the two scalar points must be different.

Example record

MassScalarInline;1812;0.001;1803

Model containing this record

Reading the example gives id = 1812, mass = 0.001, scalarPoint1 = 1803.

MassScalarProperty

A scalar mass element between two scalar points, with a MassProp property.

Record format and fields

MassScalarProperty;id;propId;scalarPoint1;scalarPoint2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

scalarPoint1

integer

0

Identifier addressing scalar or grid point data.

4

scalarPoint2

integer

0

Identifier addressing scalar or grid point data.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • scalarPoint1 — the scalar point IDs must not be negative.

  • scalarPoint2 — the two scalar points must be different.

Example record

MassScalarProperty;202;22;201;202

Model containing this record

Reading the example gives id = 202, propId = 22, scalarPoint1 = 201, scalarPoint2 = 202.

PlaneStrainQuad

A fully nonlinear plane strain quadrilateral element (PlanePropNonlinear or PlaneCompProp property) with four corners, up to four edge points and an optional centre point.

Record format and fields

PlaneStrainQuad;id;propId;node1;node2;node3;node4;node5;node6;node7;node8;node9;materialAngle;matFrameId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

node5

integer

—

Grid point to which this entry applies. Entry 5.

8

node6

integer

—

Grid point to which this entry applies. Entry 6.

9

node7

integer

—

Grid point to which this entry applies. Entry 7.

10

node8

integer

—

Grid point to which this entry applies. Entry 8.

11

node9

integer

—

Grid point to which this entry applies. Entry 9.

12

materialAngle

real

—

Angle defining the material orientation relative to the reference element axes. Alternative to matFrameId.

13

matFrameId

integer

—

Coordinate system defining the material directions. Alternative to materialAngle.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the corner grid points must be positive integers.

  • node5 — the grid point IDs must not be negative.

  • node1 — the grid points of an element must all be different.

Example record

PlaneStrainQuad;20;20;21;22;23;24;25;26;27;28;29

Model containing this record

Reading the example gives id = 20, propId = 20, node1 = 21, node2 = 22.

Referenced records in this example

  • PlanePropNonlinear via propId = 20.

  • Node via node1 = 21, node2 = 22, node3 = 23, node4 = 24, node5 = 25, node6 = 26, node7 = 27, node8 = 28, node9 = 29.

PlaneStrainQuad4

A four-node plane strain element.

Record format and fields

PlaneStrainQuad4;id;propId;node1;node2;node3;node4;materialAngle

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

materialAngle

real

0.0

Angle defining the material orientation relative to the reference element axes.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the grid point IDs must be positive integers.

  • node1 — the four grid points must all be different.

Example record

PlaneStrainQuad4;2;1;4;5;6;7;10.

Model containing this record

Reading the example gives id = 2, propId = 1, node1 = 4, node2 = 5.

Referenced records in this example

  • PlaneProp via propId = 1.

  • Node via node1 = 4, node2 = 5, node3 = 6, node4 = 7.

PlaneStrainQuad8

A plane strain quadrilateral with four corners and up to four edge points.

Record format and fields

PlaneStrainQuad8;id;propId;node1;node2;node3;node4;node5;node6;node7;node8;materialAngle

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point at corner 1 of the element connectivity.

4

node2

integer

—

Grid point at corner 2 of the element connectivity.

5

node3

integer

—

Grid point at corner 3 of the element connectivity.

6

node4

integer

—

Grid point at corner 4 of the element connectivity.

7

node5

integer

—

Additional grid point at edge position 1 after the 4 corners.

8

node6

integer

—

Additional grid point at edge position 2 after the 4 corners.

9

node7

integer

—

Additional grid point at edge position 3 after the 4 corners.

10

node8

integer

—

Additional grid point at edge position 4 after the 4 corners.

11

materialAngle

real

0.0

Angle defining the material orientation relative to the reference element axes.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the corner grid points must be positive integers.

  • node5 — the grid point IDs must not be negative.

  • node1 — the grid points of an element must all be different.

Example record

PlaneStrainQuad8;4;1;14;15;16;17;18;19;20;21;5.

Model containing this record

Reading the example gives id = 4, propId = 1, node1 = 14, node2 = 15.

Referenced records in this example

  • PlaneProp via propId = 1.

  • Node via node1 = 14, node2 = 15, node3 = 16, node4 = 17, node5 = 18, node6 = 19, node7 = 20, node8 = 21.

PlaneStrainTria3

A three-node plane strain element.

Record format and fields

PlaneStrainTria3;id;propId;node1;node2;node3;materialAngle

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

materialAngle

real

0.0

Angle defining the material orientation relative to the reference element axes.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the grid point IDs must be positive integers.

  • node1 — the three grid points must all be different.

Example record

PlaneStrainTria3;1;1;1;2;3

Model containing this record

Reading the example gives id = 1, propId = 1, node1 = 1, node2 = 2.

Referenced records in this example

  • PlaneProp via propId = 1.

  • Node via node1 = 1, node2 = 2, node3 = 3.

PlaneStrainTria6

A plane strain triangle with three corners and up to three edge points.

Record format and fields

PlaneStrainTria6;id;propId;node1;node2;node3;node4;node5;node6;materialAngle

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point at corner 1 of the element connectivity.

4

node2

integer

—

Grid point at corner 2 of the element connectivity.

5

node3

integer

—

Grid point at corner 3 of the element connectivity.

6

node4

integer

—

Additional grid point at edge position 1 after the 3 corners.

7

node5

integer

—

Additional grid point at edge position 2 after the 3 corners.

8

node6

integer

—

Additional grid point at edge position 3 after the 3 corners.

9

materialAngle

real

0.0

Angle defining the material orientation relative to the reference element axes.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the corner grid points must be positive integers.

  • node4 — the grid point IDs must not be negative.

  • node1 — the grid points of an element must all be different.

Example record

PlaneStrainTria6;3;1;8;9;10;11;12;13

Model containing this record

Reading the example gives id = 3, propId = 1, node1 = 8, node2 = 9.

Referenced records in this example

  • PlaneProp via propId = 1.

  • Node via node1 = 8, node2 = 9, node3 = 10, node4 = 11, node5 = 12, node6 = 13.

PlaneStressQuad4

A four-node plane stress element.

Record format and fields

PlaneStressQuad4;id;propId;node1;node2;node3;node4;materialAngle;thicknessFlag;thickness1;thickness2;thickness3;thickness4

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

materialAngle

real

0.0

Angle defining the material orientation relative to the reference element axes.

8

thicknessFlag

integer

0

Selects the thickness flag for PlaneStressQuad4.

9

thickness1

real

—

Through-thickness dimension, in model length units. Entry 1.

10

thickness2

real

—

Through-thickness dimension, in model length units. Entry 2.

11

thickness3

real

—

Through-thickness dimension, in model length units. Entry 3.

12

thickness4

real

—

Through-thickness dimension, in model length units. Entry 4.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the grid point IDs must be positive integers.

  • node1 — the four grid points must all be different.

  • thicknessFlag — thicknessFlag must be 0 or 1.

Example record

PlaneStressQuad4;102;2;104;105;106;107;10.

Model containing this record

Reading the example gives id = 102, propId = 2, node1 = 104, node2 = 105.

Referenced records in this example

  • PlaneProp via propId = 2.

  • Node via node1 = 104, node2 = 105, node3 = 106, node4 = 107.

PlaneStressQuad8

A plane stress quadrilateral with four corners and up to four edge points.

Record format and fields

PlaneStressQuad8;id;propId;node1;node2;node3;node4;node5;node6;node7;node8;materialAngle

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point at corner 1 of the element connectivity.

4

node2

integer

—

Grid point at corner 2 of the element connectivity.

5

node3

integer

—

Grid point at corner 3 of the element connectivity.

6

node4

integer

—

Grid point at corner 4 of the element connectivity.

7

node5

integer

—

Additional grid point at edge position 1 after the 4 corners.

8

node6

integer

—

Additional grid point at edge position 2 after the 4 corners.

9

node7

integer

—

Additional grid point at edge position 3 after the 4 corners.

10

node8

integer

—

Additional grid point at edge position 4 after the 4 corners.

11

materialAngle

real

0.0

Angle defining the material orientation relative to the reference element axes.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the corner grid points must be positive integers.

  • node5 — the grid point IDs must not be negative.

  • node1 — the grid points of an element must all be different.

Example record

PlaneStressQuad8;104;2;114;115;116;117;118;119;120;121

Model containing this record

Reading the example gives id = 104, propId = 2, node1 = 114, node2 = 115.

Referenced records in this example

  • PlaneProp via propId = 2.

  • Node via node1 = 114, node2 = 115, node3 = 116, node4 = 117, node5 = 118, node6 = 119, node7 = 120, node8 = 121.

PlaneStressTria3

A three-node plane stress element.

Record format and fields

PlaneStressTria3;id;propId;node1;node2;node3;materialAngle;thicknessFlag;thickness1;thickness2;thickness3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

materialAngle

real

0.0

Angle defining the material orientation relative to the reference element axes.

7

thicknessFlag

integer

0

Selects the thickness flag for PlaneStressTria3.

8

thickness1

real

—

Through-thickness dimension, in model length units. Entry 1.

9

thickness2

real

—

Through-thickness dimension, in model length units. Entry 2.

10

thickness3

real

—

Through-thickness dimension, in model length units. Entry 3.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the grid point IDs must be positive integers.

  • node1 — the three grid points must all be different.

  • thicknessFlag — thicknessFlag must be 0 or 1.

Example record

PlaneStressTria3;101;2;101;102;103;0.;1;1.;1.;0.75

Model containing this record

Reading the example gives id = 101, propId = 2, node1 = 101, node2 = 102.

Referenced records in this example

  • PlaneProp via propId = 2.

  • Node via node1 = 101, node2 = 102, node3 = 103.

PlaneStressTria6

A plane stress triangle with three corners and up to three edge points.

Record format and fields

PlaneStressTria6;id;propId;node1;node2;node3;node4;node5;node6;materialAngle

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point at corner 1 of the element connectivity.

4

node2

integer

—

Grid point at corner 2 of the element connectivity.

5

node3

integer

—

Grid point at corner 3 of the element connectivity.

6

node4

integer

—

Additional grid point at edge position 1 after the 3 corners.

7

node5

integer

—

Additional grid point at edge position 2 after the 3 corners.

8

node6

integer

—

Additional grid point at edge position 3 after the 3 corners.

9

materialAngle

real

0.0

Angle defining the material orientation relative to the reference element axes.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the corner grid points must be positive integers.

  • node4 — the grid point IDs must not be negative.

  • node1 — the grid points of an element must all be different.

Example record

PlaneStressTria6;103;2;108;109;110;111;112;113

Model containing this record

Reading the example gives id = 103, propId = 2, node1 = 108, node2 = 109.

Referenced records in this example

  • PlaneProp via propId = 2.

  • Node via node1 = 108, node2 = 109, node3 = 110, node4 = 111, node5 = 112, node6 = 113.

PlotLine2

A dummy line element that is only drawn on plots.

Record format and fields

PlotLine2;id;node1;node2;id2;node3;node4

Position

Field

Type

Default

Meaning and conventions

1

id

integer

—

Identifier in the namespace of this card type.

2

node1

integer

—

Identifier addressing node data.

3

node2

integer

—

Identifier addressing node data.

4

id2

integer

—

Identifier at position 2 in the ordered PlotLine2 data.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • node1 — the grid point IDs must be positive integers.

  • node2 — node1 and node2 must be different.

Example record

PlotLine2;391;309;323

Model containing this record

Reading the example gives id = 391, node1 = 309, node2 = 323.

Referenced records in this example

  • Node via node1 = 309, node2 = 323.

PlotQuad4

A dummy quadrilateral that is only drawn on plots.

Record format and fields

PlotQuad4;id;node1;node2;node3;node4

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

node1

integer

Required

Identifier addressing node data.

3

node2

integer

Required

Identifier addressing node data.

4

node3

integer

Required

Identifier addressing node data.

5

node4

integer

Required

Identifier addressing node data.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • node1 — the grid point IDs must be positive integers.

  • node2 — the four grid points must be different: node2 repeats node1.

  • node3 — the four grid points must be different: node3 repeats another one.

  • node4 — the four grid points must be different: node4 repeats another one.

Example record

PlotQuad4;12;2;3;6;5

Model containing this record

Reading the example gives id = 12, node1 = 2, node2 = 3, node3 = 6.

Referenced records in this example

  • Node via node1 = 2, node2 = 3, node3 = 6, node4 = 5.

PlotSurface

Describes a surface mesh used for display, including structural or cavity boundaries.

Record format and fields

PlotSurface;id;nodeId1;nodeId2;nodeId3;nodeId4;nodeId5;nodeId6;nodeId7;nodeId8

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

nodeId1

integer

—

Identifier addressing node data.

3

nodeId2

integer

—

Identifier of the grid point addressed by this record. Entry 2.

4

nodeId3

integer

—

Identifier of the grid point addressed by this record. Entry 3.

5

nodeId4

integer

—

Identifier of the grid point addressed by this record. Entry 4.

6

nodeId5

integer

—

Identifier of the grid point addressed by this record. Entry 5.

7

nodeId6

integer

—

Identifier of the grid point addressed by this record. Entry 6.

8

nodeId7

integer

—

Identifier of the grid point addressed by this record. Entry 7.

9

nodeId8

integer

—

Identifier of the grid point addressed by this record. Entry 8.

Accepted words: Constant, Element, Table.

Example record

PlotSurface;392;301;303;309;307

Model containing this record

Reading the example gives id = 392, nodeId1 = 301, nodeId2 = 303, nodeId3 = 309.

Referenced records in this example

  • Node via nodeId1 = 301.

PlotTria3

A dummy triangle that is only drawn on plots.

Record format and fields

PlotTria3;id;node1;node2;node3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

node1

integer

Required

Identifier addressing node data.

3

node2

integer

Required

Identifier addressing node data.

4

node3

integer

Required

Identifier addressing node data.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • node1 — the grid point IDs must be positive integers.

  • node2 — the three grid points must be different: node1 and node2 are the same.

  • node3 — the three grid points must be different: node3 repeats another one.

Example record

PlotTria3;11;1;2;5

Model containing this record

Reading the example gives id = 11, node1 = 1, node2 = 2, node3 = 5.

Referenced records in this example

  • Node via node1 = 1, node2 = 2, node3 = 5.

PointMassInertia

A concentrated mass at a grid point, with its own offset and inertia.

Record format and fields

PointMassInertia;id;node;frameId;mass;offset1;offset2;offset3;inertia11;inertia21;inertia22;inertia31;inertia32;inertia33

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

node

integer

Required

Grid point to which this entry applies.

3

frameId

integer

0

Coordinate system in which this entry is expressed.

4

mass

real

0.0

Inertial mass associated with the selected component or body.

5

offset1

real

—

Shift from the reference location or value in the convention of this entry. Entry 1.

6

offset2

real

—

Shift from the reference location or value in the convention of this entry. Entry 2.

7

offset3

real

—

Shift from the reference location or value in the convention of this entry. Entry 3.

8

inertia11

real

—

Component (1, 1) of the point mass inertia tensor (mass times length squared).

9

inertia21

real

—

Component (2, 1) of the point mass inertia tensor (mass times length squared).

10

inertia22

real

—

Component (2, 2) of the point mass inertia tensor (mass times length squared).

11

inertia31

real

—

Component (3, 1) of the point mass inertia tensor (mass times length squared).

12

inertia32

real

—

Component (3, 2) of the point mass inertia tensor (mass times length squared).

13

inertia33

real

—

Component (3, 3) of the point mass inertia tensor (mass times length squared).

Designable field descriptors: mass, offset1, offset2, offset3, inertia11, inertia21, inertia22, inertia31, inertia32, inertia33.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • node — the grid point ID must be a positive integer.

  • frameId — frameId must be -1, 0 or a coordinate system ID.

Example record

PointMassInertia;1;1;;0.001;;;;0.01;;0.01;;;0.01

Model containing this record

Reading the example gives id = 1, node = 1, mass = 0.001, inertia11 = 0.01.

Referenced records in this example

  • Node via node = 1.

PointMassMatrix

A concentrated mass at a grid point, given as a full 6 x 6 symmetric mass matrix.

Record format and fields

PointMassMatrix;id;node;frameId;massTerm11;massTerm21;massTerm22;massTerm31;massTerm32;massTerm33;massTerm41;massTerm42;massTerm43;massTerm44;massTerm51;massTerm52;massTerm53;massTerm54;massTerm55;massTerm61;massTerm62;massTerm63;massTerm64;massTerm65;massTerm66

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

node

integer

Required

Grid point to which this entry applies.

3

frameId

integer

0

Coordinate system in which this entry is expressed.

4

massTerm11

real

0.0

Entry 11 of the mass term coefficients in the local component order.

5

massTerm21

real

0.0

Entry 21 of the mass term coefficients in the local component order.

6

massTerm22

real

0.0

Entry 22 of the mass term coefficients in the local component order.

7

massTerm31

real

0.0

Entry 31 of the mass term coefficients in the local component order.

8

massTerm32

real

0.0

Entry 32 of the mass term coefficients in the local component order.

9

massTerm33

real

0.0

Entry 33 of the mass term coefficients in the local component order.

10

massTerm41

real

0.0

Entry 41 of the mass term coefficients in the local component order.

11

massTerm42

real

0.0

Entry 42 of the mass term coefficients in the local component order.

12

massTerm43

real

0.0

Entry 43 of the mass term coefficients in the local component order.

13

massTerm44

real

0.0

Entry 44 of the mass term coefficients in the local component order.

14

massTerm51

real

0.0

Entry 51 of the mass term coefficients in the local component order.

15

massTerm52

real

0.0

Entry 52 of the mass term coefficients in the local component order.

16

massTerm53

real

0.0

Entry 53 of the mass term coefficients in the local component order.

17

massTerm54

real

0.0

Entry 54 of the mass term coefficients in the local component order.

18

massTerm55

real

0.0

Entry 55 of the mass term coefficients in the local component order.

19

massTerm61

real

0.0

Entry 61 of the mass term coefficients in the local component order.

20

massTerm62

real

0.0

Entry 62 of the mass term coefficients in the local component order.

21

massTerm63

real

0.0

Entry 63 of the mass term coefficients in the local component order.

22

massTerm64

real

0.0

Entry 64 of the mass term coefficients in the local component order.

23

massTerm65

real

0.0

Entry 65 of the mass term coefficients in the local component order.

24

massTerm66

real

0.0

Entry 66 of the mass term coefficients in the local component order.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • node — the grid point ID must be a positive integer.

  • frameId — frameId must be 0 or a coordinate system ID.

Example record

PointMassMatrix;104;102;;0.001;0.;0.001;0.;0.;0.001;0.;0.;0.;1.;0.;0.;0.;0.;1.;0.;0.;0.;0.;0.;1.

Model containing this record

Reading the example gives id = 104, node = 102, massTerm11 = 0.001, massTerm21 = 0..

Referenced records in this example

  • Node via node = 102.

Rod2

A two-node line element for axial and torsional response. The rod property connects the element to its material and cross-section.

Record format and fields

Rod2;id;propId;node1;node2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

Required

First endpoint of the rod. The vector from node1 to node2 defines its local axial direction.

4

node2

integer

Required

Second endpoint of the rod. Its distance from node1 is the undeformed element length.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • node1 — the two grid points must be different.

Example record

Rod2;1;1;1;2

Model containing this record

Reading the example gives id = 1, propId = 1, node1 = 1, node2 = 2.

Referenced records in this example

  • RodProp via propId = 1.

  • Node via node1 = 1, node2 = 2.

Rod2InlineSection

A rod element with its own area and torsional constant, no property entry.

Record format and fields

Rod2InlineSection;id;node1;node2;matId;area;torsionConstant;torsionStressCoefficient;nonStructMass

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

node1

integer

Required

Grid point to which this entry applies. Entry 1.

3

node2

integer

Required

Grid point to which this entry applies. Entry 2.

4

matId

integer

Required

Material identifier used to retrieve the constitutive data.

5

area

real

0.0

Surface or cross-sectional measure, in squared model length units.

6

torsionConstant

real

0.0

Section constant multiplying the shear modulus in torsional rigidity (length to the fourth power).

7

torsionStressCoefficient

real

0.0

Coefficient in the relation for torsion stress.

8

nonStructMass

real

0.0

Additional mass distributed with the element or property; its geometric basis follows the section definition.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • node1 — the grid point IDs must be positive integers.

  • node1 — the two grid points must be different.

  • matId — the material ID must be a positive integer.

Example record

Rod2InlineSection;2;3;4;1;10.;5.

Model containing this record

Reading the example gives id = 2, node1 = 3, node2 = 4, matId = 1.

Referenced records in this example

  • Node via node1 = 3, node2 = 4.

  • IsoMat via matId = 1.

Seam

A seam that connects two surface patches (shell elements).

Record format and fields

Seam;id;propId;seamLine;patchKind;patchAStart;patchBStart;patchAEnd;patchBEnd;startNode;startX;endNode;startY;startZ;endX;endY;endZ

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

seamLine

text

—

Line identifying the path of the seam connection.

4

patchKind

text

—

Selects the patch kind for Seam.

5

patchAStart

integer

Required

First entry defining the extent of patch A.

6

patchBStart

integer

0

First entry defining the extent of patch B.

7

patchAEnd

integer

0

Last entry defining the extent of patch A.

8

patchBEnd

integer

0

Last entry defining the extent of patch B.

9

startNode

integer

—

Grid point at the beginning of the path or directed edge. Alternative to startX.

10

startX

real

—

X coordinate of the start point. Alternative to startNode.

11

endNode

integer

—

Grid point at the end of the path or directed edge. Alternative to startY.

12

startY

real

—

Y coordinate of the start point. Alternative to endNode.

13

startZ

real

—

Z coordinate of the start point.

14

endX

real

—

X coordinate of the end point.

15

endY

real

—

Y coordinate of the end point.

16

endZ

real

—

Z coordinate of the end point.

Accepted words: Constant, Element, Elements, ShellProp, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be an integer from 1 to 99999999.

  • propId — the property ID must be a positive integer.

  • patchAStart — patchAStart is required and must be a positive integer.

  • patchBStart — patchBStart must be a positive integer or blank.

  • patchAEnd — patchAEnd must be a positive integer or blank.

  • patchBEnd — patchBEnd must be a positive integer or blank.

  • startNode — the alternate format gives coordinates, not the grid points startNode and endNode.

  • startNode — startNode is required and must be a positive integer.

  • endNode — endNode is required and must be a positive integer.

  • startX — the format with the grid points startNode and endNode has no coordinates.

Example record

Seam;331;33;;;31;32;;;;5.;;105.;1.;15.;105.;1.

Model containing this record

Reading the example gives id = 331, propId = 33, patchAStart = 31, patchBStart = 32.

Referenced records in this example

SeamProp

The property of a Seam seam connection.

Record format and fields

SeamProp;id;matId;kind;width;thickness;integration

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

3

kind

text

—

Selects the kind for SeamProp.

4

width

real

Required

Transverse extent in model length units.

5

thickness

real

—

Through-thickness dimension, in model length units.

6

integration

integer

—

Selects the rule used to integrate the element or section response.

Accepted words: Constant, Element, Line, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • integration — integration must be 0 or 2.

Example record

SeamProp;33;1;;4.

Model containing this record

Reading the example gives id = 33, matId = 1, width = 4..

Referenced records in this example

ShearPanel4

A shear panel element with four corner grid points.

Record format and fields

ShearPanel4;id;propId;node1;node2;node3;node4

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the grid point IDs must be positive integers.

  • node1 — the four grid points must all be different.

Example record

ShearPanel4;7;2;701;702;703;704

Model containing this record

Reading the example gives id = 7, propId = 2, node1 = 701, node2 = 702.

Referenced records in this example

  • ShearPanelProp via propId = 2.

  • Node via node1 = 701, node2 = 702, node3 = 703, node4 = 704.

ShellAxisym

An axisymmetric thick shell line element with two end points and, optionally, a third point between them on the curve of the element.

Record format and fields

ShellAxisym;id;propId;node1;node2;node3;offset

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

offset

real

—

Shift from the reference location or value in the convention of this entry.

Accepted words: Constant, Element, Table.

Example record

ShellAxisym;32;30;302;304;303

Model containing this record

Reading the example gives id = 32, propId = 30, node1 = 302, node2 = 304.

Referenced records in this example

ShellConical2

An axisymmetric conical shell element between two rings, with a ConicalShellProp property.

Record format and fields

ShellConical2;id;propId;ringIdA;ringIdB

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

ringIdA

integer

Required

Identifier addressing node data.

4

ringIdB

integer

Required

Identifier addressing node data.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • ringIdA — the ring IDs must be positive integers.

  • ringIdB — ringIdA and ringIdB must be different.

Example record

ShellConical2;1;1;1;2

Model containing this record

Reading the example gives id = 1, propId = 1, ringIdA = 1, ringIdB = 2.

Referenced records in this example

ShellQuad4

A four-node shell element.

Record format and fields

ShellQuad4;id;propId;node1;node2;node3;node4;materialAngle;matFrameId;offset;thicknessFlag;cornerThickness1;cornerThickness2;cornerThickness3;cornerThickness4

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point at corner 1 of the element connectivity.

4

node2

integer

—

Grid point at corner 2 of the element connectivity.

5

node3

integer

—

Grid point at corner 3 of the element connectivity.

6

node4

integer

—

Grid point at corner 4 of the element connectivity.

7

materialAngle

real

—

Rotation of the material direction relative to the element axes, in degrees. Alternative to matFrameId.

8

matFrameId

integer

—

Coordinate system defining the material directions. Alternative to materialAngle.

9

offset

real

0.0

Signed distance of the reference surface from the grid-point plane, along the element normal.

10

thicknessFlag

integer

0

Selects absolute corner thicknesses or factors of the property thickness.

11

cornerThickness1

real

—

Thickness at this corner, or a multiplier of the property thickness according to the thickness flag.

12

cornerThickness2

real

—

Thickness at this corner, or a multiplier of the property thickness according to the thickness flag.

13

cornerThickness3

real

—

Thickness at this corner, or a multiplier of the property thickness according to the thickness flag.

14

cornerThickness4

real

—

Thickness at this corner, or a multiplier of the property thickness according to the thickness flag.

Designable field descriptors: offset, cornerThickness1, cornerThickness2, cornerThickness3, cornerThickness4.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • node1 — the four grid points must all be different.

Example record

ShellQuad4;1;1;1;2;7;6

Model containing this record

Reading the example gives id = 1, propId = 1, node1 = 1, node2 = 2.

Referenced records in this example

  • ShellProp via propId = 1.

  • Node via node1 = 1, node2 = 2, node3 = 7, node4 = 6.

ShellQuad4Drilling

A four-node plate element with a drilling rotation.

Record format and fields

ShellQuad4Drilling;id;propId;node1;node2;node3;node4;materialAngle;matFrameId;offset;thicknessFlag;cornerThickness1;cornerThickness2;cornerThickness3;cornerThickness4

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

materialAngle

real

—

Angle defining the material orientation relative to the reference element axes. Alternative to matFrameId.

8

matFrameId

integer

—

Coordinate system defining the material directions. Alternative to materialAngle.

9

offset

real

0.0

Shift from the reference location or value in the convention of this entry.

10

thicknessFlag

integer

0

Selects the thickness flag for ShellQuad4Drilling.

11

cornerThickness1

real

—

Corner thickness 1 (length).

12

cornerThickness2

real

—

Corner thickness 2 (length).

13

cornerThickness3

real

—

Corner thickness 3 (length).

14

cornerThickness4

real

—

Corner thickness 4 (length).

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • node1 — the four grid points must all be different.

Example record

ShellQuad4Drilling;3;1;301;302;303;304

Model containing this record

Reading the example gives id = 3, propId = 1, node1 = 301, node2 = 302.

Referenced records in this example

  • ShellProp via propId = 1.

  • Node via node1 = 301, node2 = 302, node3 = 303, node4 = 304.

ShellQuad8

A curved quadrilateral shell element with four corners and up to four edge points.

Record format and fields

ShellQuad8;id;propId;node1;node2;node3;node4;node5;node6;node7;node8;cornerThickness1;cornerThickness2;cornerThickness3;cornerThickness4;materialAngle;matFrameId;offset;thicknessFlag

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point at corner 1 of the element connectivity.

4

node2

integer

—

Grid point at corner 2 of the element connectivity.

5

node3

integer

—

Grid point at corner 3 of the element connectivity.

6

node4

integer

—

Grid point at corner 4 of the element connectivity.

7

node5

integer

—

Additional grid point at edge position 1 after the 4 corners.

8

node6

integer

—

Additional grid point at edge position 2 after the 4 corners.

9

node7

integer

—

Additional grid point at edge position 3 after the 4 corners.

10

node8

integer

—

Additional grid point at edge position 4 after the 4 corners.

11

cornerThickness1

real

—

Thickness at this corner, or a multiplier of the property thickness according to the thickness flag.

12

cornerThickness2

real

—

Thickness at this corner, or a multiplier of the property thickness according to the thickness flag.

13

cornerThickness3

real

—

Thickness at this corner, or a multiplier of the property thickness according to the thickness flag.

14

cornerThickness4

real

—

Thickness at this corner, or a multiplier of the property thickness according to the thickness flag.

15

materialAngle

real

—

Rotation of the material direction relative to the element axes, in degrees. Alternative to matFrameId.

16

matFrameId

integer

—

Coordinate system defining the material directions. Alternative to materialAngle.

17

offset

real

0.0

Signed distance of the reference surface from the grid-point plane, along the element normal.

18

thicknessFlag

integer

0

Selects absolute corner thicknesses or factors of the property thickness.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the corner grid points must be positive integers.

  • node5 — the grid point IDs must not be negative.

  • node1 — the grid points of an element must all be different.

  • thicknessFlag — thicknessFlag must be 0 or 1.

Example record

ShellQuad8;1;6;1;2;3;4;5;6;7;8

Model containing this record

Reading the example gives id = 1, propId = 6, node1 = 1, node2 = 2.

Referenced records in this example

  • PlanePropNonlinear via propId = 6.

  • Node via node1 = 1, node2 = 2, node3 = 3, node4 = 4, node5 = 5, node6 = 6, node7 = 7, node8 = 8.

ShellTria3

A three-node shell element.

Record format and fields

ShellTria3;id;propId;node1;node2;node3;materialAngle;matFrameId;offset;thicknessFlag;cornerThickness1;cornerThickness2;cornerThickness3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point at corner 1 of the element connectivity.

4

node2

integer

—

Grid point at corner 2 of the element connectivity.

5

node3

integer

—

Grid point at corner 3 of the element connectivity.

6

materialAngle

real

—

Rotation of the material direction relative to the element axes, in degrees. Alternative to matFrameId.

7

matFrameId

integer

—

Coordinate system defining the material directions. Alternative to materialAngle.

8

offset

real

0.0

Signed distance of the reference surface from the grid-point plane, along the element normal.

9

thicknessFlag

integer

0

Selects absolute corner thicknesses or factors of the property thickness.

10

cornerThickness1

real

—

Thickness at this corner, or a multiplier of the property thickness according to the thickness flag.

11

cornerThickness2

real

—

Thickness at this corner, or a multiplier of the property thickness according to the thickness flag.

12

cornerThickness3

real

—

Thickness at this corner, or a multiplier of the property thickness according to the thickness flag.

Designable field descriptors: offset, cornerThickness1, cornerThickness2, cornerThickness3.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the grid point IDs must be positive integers.

  • node1 — the three grid points must all be different.

  • thicknessFlag — thicknessFlag must be 0 or 1.

Example record

ShellTria3;201;1;201;202;205;30.

Model containing this record

Reading the example gives id = 201, propId = 1, node1 = 201, node2 = 202.

ShellTria3Drilling

A three-node plate element with a drilling rotation.

Record format and fields

ShellTria3Drilling;id;propId;node1;node2;node3;materialAngle;matFrameId;offset;thicknessFlag;cornerThickness1;cornerThickness2;cornerThickness3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

materialAngle

real

—

Angle defining the material orientation relative to the reference element axes. Alternative to matFrameId.

7

matFrameId

integer

—

Coordinate system defining the material directions. Alternative to materialAngle.

8

offset

real

0.0

Shift from the reference location or value in the convention of this entry.

9

thicknessFlag

integer

0

Selects the thickness flag for ShellTria3Drilling.

10

cornerThickness1

real

—

Corner thickness 1 (length).

11

cornerThickness2

real

—

Corner thickness 2 (length).

12

cornerThickness3

real

—

Corner thickness 3 (length).

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the grid point IDs must be positive integers.

  • node1 — the three grid points must all be different.

  • thicknessFlag — thicknessFlag must be 0 or 1.

Example record

ShellTria3Drilling;401;1;401;402;405;30.

Model containing this record

Reading the example gives id = 401, propId = 1, node1 = 401, node2 = 402.

ShellTria6

A curved triangular shell element with three corners and up to three edge points.

Record format and fields

ShellTria6;id;propId;node1;node2;node3;node4;node5;node6;materialAngle;matFrameId;offset;cornerThickness1;cornerThickness2;cornerThickness3;thicknessFlag

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

—

Grid point at corner 1 of the element connectivity.

4

node2

integer

—

Grid point at corner 2 of the element connectivity.

5

node3

integer

—

Grid point at corner 3 of the element connectivity.

6

node4

integer

—

Additional grid point at edge position 1 after the 3 corners.

7

node5

integer

—

Additional grid point at edge position 2 after the 3 corners.

8

node6

integer

—

Additional grid point at edge position 3 after the 3 corners.

9

materialAngle

real

—

Rotation of the material direction relative to the element axes, in degrees. Alternative to matFrameId.

10

matFrameId

integer

—

Coordinate system defining the material directions. Alternative to materialAngle.

11

offset

real

0.0

Signed distance of the reference surface from the grid-point plane, along the element normal.

12

cornerThickness1

real

—

Thickness at this corner, or a multiplier of the property thickness according to the thickness flag.

13

cornerThickness2

real

—

Thickness at this corner, or a multiplier of the property thickness according to the thickness flag.

14

cornerThickness3

real

—

Thickness at this corner, or a multiplier of the property thickness according to the thickness flag.

15

thicknessFlag

integer

0

Selects absolute corner thicknesses or factors of the property thickness.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the corner grid points must be positive integers.

  • node4 — the grid point IDs must not be negative.

  • node1 — the grid points of an element must all be different.

  • thicknessFlag — thicknessFlag must be 0 or 1.

Example record

ShellTria6;2;6;11;12;13;14;15;16

Model containing this record

Reading the example gives id = 2, propId = 6, node1 = 11, node2 = 12.

Referenced records in this example

  • PlanePropNonlinear via propId = 6.

  • Node via node1 = 11, node2 = 12, node3 = 13, node4 = 14, node5 = 15, node6 = 16.

SolidHexa

A hexahedral solid with eight corner nodes and up to twelve additional edge nodes.

Record format and fields

SolidHexa;id;propId;node1;node2;node3;node4;node5;node6;node7;node8;node9;node10;node11;node12;node13;node14;node15;node16;node17;node18;node19;node20

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

Required

Grid point at corner 1 of the element connectivity.

4

node2

integer

Required

Grid point at corner 2 of the element connectivity.

5

node3

integer

Required

Grid point at corner 3 of the element connectivity.

6

node4

integer

Required

Grid point at corner 4 of the element connectivity.

7

node5

integer

Required

Grid point at corner 5 of the element connectivity.

8

node6

integer

Required

Grid point at corner 6 of the element connectivity.

9

node7

integer

Required

Grid point at corner 7 of the element connectivity.

10

node8

integer

Required

Grid point at corner 8 of the element connectivity.

11

node9

integer

0

Optional grid point on the edge joining corners 1 and 2. Blank or zero omits it.

12

node10

integer

0

Optional grid point on the edge joining corners 2 and 3. Blank or zero omits it.

13

node11

integer

0

Optional grid point on the edge joining corners 3 and 4. Blank or zero omits it.

14

node12

integer

0

Optional grid point on the edge joining corners 4 and 1. Blank or zero omits it.

15

node13

integer

0

Optional grid point on the edge joining corners 1 and 5. Blank or zero omits it.

16

node14

integer

0

Optional grid point on the edge joining corners 2 and 6. Blank or zero omits it.

17

node15

integer

0

Optional grid point on the edge joining corners 3 and 7. Blank or zero omits it.

18

node16

integer

0

Optional grid point on the edge joining corners 4 and 8. Blank or zero omits it.

19

node17

integer

0

Optional grid point on the edge joining corners 5 and 6. Blank or zero omits it.

20

node18

integer

0

Optional grid point on the edge joining corners 6 and 7. Blank or zero omits it.

21

node19

integer

0

Optional grid point on the edge joining corners 7 and 8. Blank or zero omits it.

22

node20

integer

0

Optional grid point on the edge joining corners 8 and 5. Blank or zero omits it.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the corner grid points must be positive integers.

  • node5 — the grid point IDs must not be negative.

  • node1 — the grid points of an element must all be different.

Example record

SolidHexa;1;1;1;2;3;4;5;6;7;8

Model containing this record

Reading the example gives id = 1, propId = 1, node1 = 1, node2 = 2.

Referenced records in this example

  • SolidProp via propId = 1.

  • Node via node1 = 1, node2 = 2, node3 = 3, node4 = 4, node5 = 5, node6 = 6, node7 = 7, node8 = 8.

SolidPenta

A prismatic solid with six corner nodes and up to nine additional edge nodes.

Record format and fields

SolidPenta;id;propId;node1;node2;node3;node4;node5;node6;node7;node8;node9;node10;node11;node12;node13;node14;node15

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

Required

Grid point at corner 1 of the element connectivity.

4

node2

integer

Required

Grid point at corner 2 of the element connectivity.

5

node3

integer

Required

Grid point at corner 3 of the element connectivity.

6

node4

integer

Required

Grid point at corner 4 of the element connectivity.

7

node5

integer

Required

Grid point at corner 5 of the element connectivity.

8

node6

integer

Required

Grid point at corner 6 of the element connectivity.

9

node7

integer

0

Optional grid point on the edge joining corners 1 and 2. Blank or zero omits it.

10

node8

integer

0

Optional grid point on the edge joining corners 2 and 3. Blank or zero omits it.

11

node9

integer

0

Optional grid point on the edge joining corners 3 and 1. Blank or zero omits it.

12

node10

integer

0

Optional grid point on the edge joining corners 1 and 4. Blank or zero omits it.

13

node11

integer

0

Optional grid point on the edge joining corners 2 and 5. Blank or zero omits it.

14

node12

integer

0

Optional grid point on the edge joining corners 3 and 6. Blank or zero omits it.

15

node13

integer

0

Optional grid point on the edge joining corners 4 and 5. Blank or zero omits it.

16

node14

integer

0

Optional grid point on the edge joining corners 5 and 6. Blank or zero omits it.

17

node15

integer

0

Optional grid point on the edge joining corners 6 and 4. Blank or zero omits it.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the corner grid points must be positive integers.

  • node5 — the grid point IDs must not be negative.

  • node1 — the grid points of an element must all be different.

Example record

SolidPenta;71;7;21;22;23;24;25;26

Model containing this record

Reading the example gives id = 71, propId = 7, node1 = 21, node2 = 22.

Referenced records in this example

  • SolidProp via propId = 7.

  • Node via node1 = 21, node2 = 22, node3 = 23, node4 = 24, node5 = 25, node6 = 26.

SolidPropNonlinear

The nonlinear extension of the SolidProp with the same property ID, for the solid elements (SolidHexa, SolidPenta, SolidPyramid and SolidTetra) that name the SolidProp.

Record format and fields

SolidPropNonlinear;id;matId;direction;analysisType;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

matId

integer

0

Material identifier used to retrieve the constitutive data.

3

direction

integer

1

Orientation in which the specified quantity acts or is measured.

4

analysisType

text

—

Selects the analysis type for SolidPropNonlinear.

Keyed sections in behaviorLines

Begin each section with its key, then write its fixed fields and any counted list.

Section FourNodeElems

Position

Field

Type

Default

Meaning and conventions

1

behavior4

text

—

Selects the assumed response of the body or contact formulation. Entry 4.

2

integration4

text

—

Selects the rule used to integrate the element or section response. Entry 4.

3

heatBehavior4

text

—

Heat behavior setting for the element configuration identified by 4.

4

heatIntegration4

text

—

Heat integration setting for the element configuration identified by 4.

Section FiveNodeElems

Position

Field

Type

Default

Meaning and conventions

1

behavior5

text

—

Selects the assumed response of the body or contact formulation. Entry 5.

2

integration5

text

—

Selects the rule used to integrate the element or section response. Entry 5.

3

heatBehavior5

text

—

Heat behavior setting for the element configuration identified by 5.

4

heatIntegration5

text

—

Heat integration setting for the element configuration identified by 5.

Section SixNodeElems

Position

Field

Type

Default

Meaning and conventions

1

behavior6

text

—

Selects the assumed response of the body or contact formulation. Entry 6.

2

integration6

text

—

Selects the rule used to integrate the element or section response. Entry 6.

3

heatBehavior6

text

—

Heat behavior setting for the element configuration identified by 6.

4

heatIntegration6

text

—

Heat integration setting for the element configuration identified by 6.

Section EightNodeElems

Position

Field

Type

Default

Meaning and conventions

1

behavior8

text

—

Selects the assumed response of the body or contact formulation. Entry 8.

2

integration8

text

—

Selects the rule used to integrate the element or section response. Entry 8.

3

heatBehavior8

text

—

Heat behavior setting for the element configuration identified by 8.

4

heatIntegration8

text

—

Heat integration setting for the element configuration identified by 8.

Section TenNodeElems

Position

Field

Type

Default

Meaning and conventions

1

behavior10

text

—

Selects the assumed response of the body or contact formulation. Entry 10.

2

integration10

text

—

Selects the rule used to integrate the element or section response. Entry 10.

3

heatBehavior10

text

—

Heat behavior setting for the element configuration identified by 10.

4

heatIntegration10

text

—

Heat integration setting for the element configuration identified by 10.

Section ThirteenNodeElems

Position

Field

Type

Default

Meaning and conventions

1

behavior13

text

—

Selects the assumed response of the body or contact formulation. Entry 13.

2

integration13

text

—

Selects the rule used to integrate the element or section response. Entry 13.

3

heatBehavior13

text

—

Heat behavior setting for the element configuration identified by 13.

4

heatIntegration13

text

—

Heat integration setting for the element configuration identified by 13.

Section FifteenNodeElems

Position

Field

Type

Default

Meaning and conventions

1

behavior15

text

—

Selects the assumed response of the body or contact formulation. Entry 15.

2

integration15

text

—

Selects the rule used to integrate the element or section response. Entry 15.

3

heatBehavior15

text

—

Heat behavior setting for the element configuration identified by 15.

4

heatIntegration15

text

—

Heat integration setting for the element configuration identified by 15.

Section TwentyNodeElems

Position

Field

Type

Default

Meaning and conventions

1

behavior20

text

—

Selects the assumed response of the body or contact formulation. Entry 20.

2

integration20

text

—

Selects the rule used to integrate the element or section response. Entry 20.

3

heatBehavior20

text

—

Heat behavior setting for the element configuration identified by 20.

4

heatIntegration20

text

—

Heat integration setting for the element configuration identified by 20.

Accepted words: AssumedStrain, AxisymComposite, Bar, Beam, Constant, EightNodeElems, Element, FifteenNodeElems, FiveNodeElems, FourNodeElems, ImplicitHeat, ImplicitStructural, ImplicitStructuralHeat, IncompressibleSolid, Linear, LinearCubic, LinearCubicClosed, LinearCubicOpen, LinearReducedHourglass, LinearShear, Membrane, Numerical, PlaneStrainComposite, Quadratic, QuadraticReduced, Rod, SixNodeElems, Smeared, Solid, SolidComposite, Table, TenNodeElems, ThirteenNodeElems, TwentyNodeElems.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • direction — direction must be 1, 2 or 3.

Example record

SolidPropNonlinear;1;1;;ImplicitStructural;EightNodeElems;Solid;Linear

Model containing this record

Reading the example gives id = 1, matId = 1, analysisType = ImplicitStructural.

Referenced records in this example

SolidPyramid

A solid with four corners on a quadrilateral base, one apex and up to eight additional edge nodes.

Record format and fields

SolidPyramid;id;propId;node1;node2;node3;node4;node5;node6;node7;node8;node9;node10;node11;node12;node13

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

Required

Grid point at corner 1 of the element connectivity.

4

node2

integer

Required

Grid point at corner 2 of the element connectivity.

5

node3

integer

Required

Grid point at corner 3 of the element connectivity.

6

node4

integer

Required

Grid point at corner 4 of the element connectivity.

7

node5

integer

Required

Grid point at corner 5 of the element connectivity.

8

node6

integer

0

Optional grid point on the edge joining corners 1 and 2. Blank or zero omits it.

9

node7

integer

0

Optional grid point on the edge joining corners 2 and 3. Blank or zero omits it.

10

node8

integer

0

Optional grid point on the edge joining corners 3 and 4. Blank or zero omits it.

11

node9

integer

0

Optional grid point on the edge joining corners 4 and 1. Blank or zero omits it.

12

node10

integer

0

Optional grid point on the edge joining corners 1 and 5. Blank or zero omits it.

13

node11

integer

0

Optional grid point on the edge joining corners 2 and 5. Blank or zero omits it.

14

node12

integer

0

Optional grid point on the edge joining corners 3 and 5. Blank or zero omits it.

15

node13

integer

0

Optional grid point on the edge joining corners 4 and 5. Blank or zero omits it.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the corner grid points must be positive integers.

  • node6 — the grid point IDs must not be negative.

  • node1 — the grid points of an element must all be different.

Example record

SolidPyramid;401;7;401;402;403;404;405

Model containing this record

Reading the example gives id = 401, propId = 7, node1 = 401, node2 = 402.

Referenced records in this example

  • SolidProp via propId = 7.

  • Node via node1 = 401, node2 = 402, node3 = 403, node4 = 404, node5 = 405.

SolidTetra

A tetrahedral solid with four corner nodes and up to six additional nodes on its edges. The position of an edge-node ID in the record determines which edge it belongs to.

Record format and fields

SolidTetra;id;propId;node1;node2;node3;node4;node5;node6;node7;node8;node9;node10

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

Required

Grid point at corner 1 of the element connectivity.

4

node2

integer

Required

Grid point at corner 2 of the element connectivity.

5

node3

integer

Required

Grid point at corner 3 of the element connectivity.

6

node4

integer

Required

Grid point at corner 4 of the element connectivity.

7

node5

integer

0

Optional grid point on the edge joining corners 1 and 2. Blank or zero omits it.

8

node6

integer

0

Optional grid point on the edge joining corners 2 and 3. Blank or zero omits it.

9

node7

integer

0

Optional grid point on the edge joining corners 3 and 1. Blank or zero omits it.

10

node8

integer

0

Optional grid point on the edge joining corners 1 and 4. Blank or zero omits it.

11

node9

integer

0

Optional grid point on the edge joining corners 2 and 4. Blank or zero omits it.

12

node10

integer

0

Optional grid point on the edge joining corners 3 and 4. Blank or zero omits it.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the corner grid points must be positive integers.

  • node5 — the grid point IDs must not be negative.

  • node1 — the grid points of an element must all be different.

Example record

SolidTetra;72;7;24;25;26;27

Model containing this record

Reading the example gives id = 72, propId = 7, node1 = 24, node2 = 25.

Referenced records in this example

  • SolidProp via propId = 7.

  • Node via node1 = 24, node2 = 25, node3 = 26, node4 = 27.

SpringDofInline

A scalar spring that holds its own stiffness (no property).

Record format and fields

SpringDofInline;id;stiffness;node1;components1;node2;components2;structuralDamping;stressCoefficient

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

stiffness

real

Required

Elastic restoring coefficient relating generalized force to the associated displacement.

3

node1

integer

0

Identifier addressing scalar or grid point data.

4

components1

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1.

5

node2

integer

0

Identifier addressing scalar or grid point data.

6

components2

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2.

7

structuralDamping

real

0.0

Structural damping coefficient for the associated material or property.

8

stressCoefficient

real

0.0

Coefficient used to recover stress from the element force or section response.

Designable field descriptors: stiffness, structuralDamping, stressCoefficient.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • node1 — the point IDs must not be negative.

  • components1 — components1 must be a component from 0 to 6.

  • components2 — components2 must be a component from 0 to 6.

Example record

SpringDofInline;3;1.E+3;2;1;101;1

Model containing this record

Reading the example gives id = 3, stiffness = 1.E+3, node1 = 2, components1 = 1.

SpringDofInlineExplicit

The scalar spring that holds its own stiffness (no property), with the coordinate system its direction is given in.

Record format and fields

SpringDofInlineExplicit;id;stiffness;node1;components1;node2;components2;frameId;follow

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

stiffness

real

Required

Elastic restoring coefficient relating generalized force to the associated displacement.

3

node1

integer

0

Identifier addressing scalar or grid point data.

4

components1

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1.

5

node2

integer

0

Identifier addressing scalar or grid point data.

6

components2

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2.

7

frameId

integer

0

Coordinate system in which this entry is expressed.

8

follow

text

—

Specifies whether the direction or attachment follows the changing configuration.

Accepted words: Constant, CoordinateFrame, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • node1 — the point ID node1 must not be negative.

  • components1 — components1 must be 0 or a list of the digits 1 to 6, each at most once.

  • node2 — the point ID node2 must not be negative.

  • components2 — components2 must be 0 or a list of the digits 1 to 6, each at most once.

  • frameId — the coordinate system ID must not be negative.

Example record

SpringDofInlineExplicit;4001;50.;3012;3

Model containing this record

Reading the example gives id = 4001, stiffness = 50., node1 = 3012, components1 = 3.

SpringDofProperty

A scalar spring that refers to a SpringProp property.

Record format and fields

SpringDofProperty;id;propId;node1;components1;node2;components2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

0

Identifier addressing scalar or grid point data.

4

components1

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1.

5

node2

integer

0

Identifier addressing scalar or grid point data.

6

components2

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the point IDs must not be negative.

  • components1 — components1 must be a component from 0 to 6.

  • components2 — components2 must be a component from 0 to 6.

Example record

SpringDofProperty;201;201;201;1

Model containing this record

Reading the example gives id = 201, propId = 201, node1 = 201, components1 = 1.

SpringDofPropertyExplicit

The scalar spring that names a property, with the coordinate system its direction is given in.

Record format and fields

SpringDofPropertyExplicit;id;propId;node1;components1;node2;components2;frameId;follow

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

0

Identifier addressing scalar or grid point data.

4

components1

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1.

5

node2

integer

0

Identifier addressing scalar or grid point data.

6

components2

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 2.

7

frameId

integer

0

Coordinate system in which this entry is expressed.

8

follow

text

—

Specifies whether the direction or attachment follows the changing configuration.

Accepted words: CoordinateFrame.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the point ID node1 must not be negative.

  • components1 — components1 must be 0 or a list of the digits 1 to 6, each at most once.

  • node2 — the point ID node2 must not be negative.

  • components2 — components2 must be 0 or a list of the digits 1 to 6, each at most once.

  • frameId — the coordinate system ID must not be negative.

Example record

SpringDofPropertyExplicit;11;10;2;1;1;1

Model containing this record

Reading the example gives id = 11, propId = 10, node1 = 2, components1 = 1.

Referenced records in this example

SpringOffsetExplicit

Defines a discrete spring with offsets between its attachment points in an explicit model.

Record format and fields

SpringOffsetExplicit;id;propId;node1;node2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

Required

Grid point to which this entry applies. Entry 1.

4

node2

integer

Required

Grid point to which this entry applies. Entry 2.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the grid point IDs must be positive integers.

  • node2 — the grid point IDs must be positive integers.

Example record

SpringOffsetExplicit;21;20;3;4

Model containing this record

Reading the example gives id = 21, propId = 20, node1 = 3, node2 = 4.

Referenced records in this example

SpringScalarInline

A scalar spring between two scalar points, with its own stiffness (no property).

Record format and fields

SpringScalarInline;id;stiffness;scalarPoint1;scalarPoint2;id2;stiffness2;scalarPoint3;scalarPoint4

Position

Field

Type

Default

Meaning and conventions

1

id

integer

—

Identifier in the element namespace.

2

stiffness

real

—

Elastic restoring coefficient relating generalized force to the associated displacement.

3

scalarPoint1

integer

0

Identifier addressing scalar or grid point data.

4

scalarPoint2

integer

0

Identifier addressing scalar or grid point data.

5

id2

integer

—

Identifier at position 2 in the ordered SpringScalarInline data.

6

stiffness2

real

—

Elastic restoring coefficient relating generalized force to the associated displacement. Entry 2.

7

scalarPoint3

integer

0

Scalar point at position 3 in the ordered connection.

8

scalarPoint4

integer

0

Scalar point at position 4 in the ordered connection.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • scalarPoint1 — the scalar point IDs must not be negative.

  • scalarPoint1 — scalarPoint1 and scalarPoint2 cannot both be blank or zero.

  • scalarPoint2 — the two scalar points must be different.

Example record

SpringScalarInline;203;500.;203

Model containing this record

Reading the example gives id = 203, stiffness = 500., scalarPoint1 = 203.

SpringScalarProperty

A scalar spring between two scalar points, with a SpringProp property.

Record format and fields

SpringScalarProperty;id;propId;scalarPoint1;scalarPoint2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

scalarPoint1

integer

0

Identifier addressing scalar or grid point data.

4

scalarPoint2

integer

0

Identifier addressing scalar or grid point data.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • scalarPoint1 — the scalar point IDs must not be negative.

  • scalarPoint2 — the two scalar points must be different.

Example record

SpringScalarProperty;204;23;201;202

Model containing this record

Reading the example gives id = 204, propId = 23, scalarPoint1 = 201, scalarPoint2 = 202.

Tube2

A tension-compression-torsion tube element between two grid points.

Record format and fields

Tube2;id;propId;node1;node2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

Required

Grid point to which this entry applies. Entry 1.

4

node2

integer

Required

Grid point to which this entry applies. Entry 2.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • node1 — the two grid points must be different.

Example record

Tube2;3;3;5;6

Model containing this record

Reading the example gives id = 3, propId = 3, node1 = 5, node2 = 6.

Referenced records in this example

UserDefined1

The connection of a user dummy element of number 1, an element whose stiffness, mass and output are computed by routines the user links into the solver.

Record format and fields

UserDefined1;id;propId;<connectionFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

Repeated group connectionFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

connectionField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — id must be an integer from 1 to 99999999.

  • node1 — node1 is required: the field after propId is a positive integer.

Example record

UserDefined1;1;11;1;2;45.

Model containing this record

Reading the example gives id = 1, propId = 11.

UserDefined1Attributes

The attributes of the user dummy element number 1, whose connection is a UserDefined1 card and whose property is a UserDefined1Prop card.

Record format and fields

UserDefined1Attributes;nodeCount;connectionFieldCount;propertyFieldCount;displacementComponentCount;elementName

Position

Field

Type

Default

Meaning and conventions

1

nodeCount

integer

Required

Number of node entries.

2

connectionFieldCount

integer

0

Number of connection field entries.

3

propertyFieldCount

integer

0

Number of property field entries.

4

displacementComponentCount

integer

0

Number of displacement component entries.

5

elementName

text

—

Text naming the element.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • nodeCount — nodeCount must be a positive integer.

  • connectionFieldCount — connectionFieldCount must not be negative.

  • propertyFieldCount — propertyFieldCount must be an integer from 0 to 24.

  • displacementComponentCount — displacementComponentCount must be 0 (no differential stiffness), 3 or 6.

Example record

UserDefined1Attributes;2;1;2;0

Model containing this record

Reading the example gives nodeCount = 2, connectionFieldCount = 1, propertyFieldCount = 2, displacementComponentCount = 0.

UserDefined1Prop

Supplies the property data for UserDefined1 elements. The user element determines the meaning of the property values.

Record format and fields

UserDefined1Prop;id;matId;<propertyFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

Repeated group propertyFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

propertyField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • propertyFields — the card has at most 24 additional fields.

Example record

UserDefined1Prop;11;1;1.;250.

Model containing this record

Reading the example gives id = 11, matId = 1.

Referenced records in this example

UserDefined2

The connection of a user dummy element of number 2, an element whose stiffness, mass and output are computed by routines the user links into the solver.

Record format and fields

UserDefined2;id;propId;<connectionFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

Repeated group connectionFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

connectionField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — id must be an integer from 1 to 99999999.

  • node1 — node1 is required: the field after propId is a positive integer.

Example record

UserDefined2;2;12;2;3;50.

Model containing this record

Reading the example gives id = 2, propId = 12.

UserDefined2Attributes

The attributes of the user dummy element number 2, whose connection is a UserDefined2 card and whose property is a UserDefined2Prop card.

Record format and fields

UserDefined2Attributes;nodeCount;connectionFieldCount;propertyFieldCount;displacementComponentCount;elementName

Position

Field

Type

Default

Meaning and conventions

1

nodeCount

integer

Required

Number of node entries.

2

connectionFieldCount

integer

0

Number of connection field entries.

3

propertyFieldCount

integer

0

Number of property field entries.

4

displacementComponentCount

integer

0

Number of displacement component entries.

5

elementName

text

—

Text naming the element.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • nodeCount — nodeCount must be a positive integer.

  • connectionFieldCount — connectionFieldCount must not be negative.

  • propertyFieldCount — propertyFieldCount must be an integer from 0 to 24.

  • displacementComponentCount — displacementComponentCount must be 0 (no differential stiffness), 3 or 6.

Example record

UserDefined2Attributes;2;1;2;0;UserDefined2

Model containing this record

Reading the example gives nodeCount = 2, connectionFieldCount = 1, propertyFieldCount = 2, displacementComponentCount = 0.

UserDefined2Prop

Supplies the property data for UserDefined2 elements. The user element determines the meaning of the property values.

Record format and fields

UserDefined2Prop;id;matId;<propertyFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

Repeated group propertyFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

propertyField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • propertyFields — the card has at most 24 additional fields.

Example record

UserDefined2Prop;12;1;1.;250.

Model containing this record

Reading the example gives id = 12, matId = 1.

Referenced records in this example

UserDefined3

The connection of a user dummy element of number 3, an element whose stiffness, mass and output are computed by routines the user links into the solver.

Record format and fields

UserDefined3;id;propId;<connectionFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

Repeated group connectionFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

connectionField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — id must be an integer from 1 to 99999999.

  • node1 — node1 is required: the field after propId is a positive integer.

Example record

UserDefined3;3;13;3;4;55.

Model containing this record

Reading the example gives id = 3, propId = 13.

UserDefined3Attributes

The attributes of the user dummy element number 3, whose connection is a UserDefined3 card and whose property is a UserDefined3Prop card.

Record format and fields

UserDefined3Attributes;nodeCount;connectionFieldCount;propertyFieldCount;displacementComponentCount;elementName

Position

Field

Type

Default

Meaning and conventions

1

nodeCount

integer

Required

Number of node entries.

2

connectionFieldCount

integer

0

Number of connection field entries.

3

propertyFieldCount

integer

0

Number of property field entries.

4

displacementComponentCount

integer

0

Number of displacement component entries.

5

elementName

text

—

Text naming the element.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • nodeCount — nodeCount must be a positive integer.

  • connectionFieldCount — connectionFieldCount must not be negative.

  • propertyFieldCount — propertyFieldCount must be an integer from 0 to 24.

  • displacementComponentCount — displacementComponentCount must be 0 (no differential stiffness), 3 or 6.

Example record

UserDefined3Attributes;2;1;2;0;UserDefined3

Model containing this record

Reading the example gives nodeCount = 2, connectionFieldCount = 1, propertyFieldCount = 2, displacementComponentCount = 0.

UserDefined3Prop

Supplies the property data for UserDefined3 elements. The user element determines the meaning of the property values.

Record format and fields

UserDefined3Prop;id;matId;<propertyFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

Repeated group propertyFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

propertyField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • propertyFields — the card has at most 24 additional fields.

Example record

UserDefined3Prop;13;1;1.;250.

Model containing this record

Reading the example gives id = 13, matId = 1.

Referenced records in this example

UserDefined4

The connection of a user dummy element of number 4, an element whose stiffness, mass and output are computed by routines the user links into the solver.

Record format and fields

UserDefined4;id;propId;<connectionFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

Repeated group connectionFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

connectionField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — id must be an integer from 1 to 99999999.

  • node1 — node1 is required: the field after propId is a positive integer.

Example record

UserDefined4;4;14;4;5;60.

Model containing this record

Reading the example gives id = 4, propId = 14.

UserDefined4Attributes

The attributes of the user dummy element number 4, whose connection is a UserDefined4 card and whose property is a UserDefined4Prop card.

Record format and fields

UserDefined4Attributes;nodeCount;connectionFieldCount;propertyFieldCount;displacementComponentCount;elementName

Position

Field

Type

Default

Meaning and conventions

1

nodeCount

integer

Required

Number of node entries.

2

connectionFieldCount

integer

0

Number of connection field entries.

3

propertyFieldCount

integer

0

Number of property field entries.

4

displacementComponentCount

integer

0

Number of displacement component entries.

5

elementName

text

—

Text naming the element.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • nodeCount — nodeCount must be a positive integer.

  • connectionFieldCount — connectionFieldCount must not be negative.

  • propertyFieldCount — propertyFieldCount must be an integer from 0 to 24.

  • displacementComponentCount — displacementComponentCount must be 0 (no differential stiffness), 3 or 6.

Example record

UserDefined4Attributes;2;1;2;0;UserDefined4

Model containing this record

Reading the example gives nodeCount = 2, connectionFieldCount = 1, propertyFieldCount = 2, displacementComponentCount = 0.

UserDefined4Prop

Supplies the property data for UserDefined4 elements. The user element determines the meaning of the property values.

Record format and fields

UserDefined4Prop;id;matId;<propertyFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

Repeated group propertyFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

propertyField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • propertyFields — the card has at most 24 additional fields.

Example record

UserDefined4Prop;14;1;1.;250.

Model containing this record

Reading the example gives id = 14, matId = 1.

Referenced records in this example

UserDefined5

The connection of a user dummy element of number 5, an element whose stiffness, mass and output are computed by routines the user links into the solver.

Record format and fields

UserDefined5;id;propId;<connectionFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

Repeated group connectionFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

connectionField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — id must be an integer from 1 to 99999999.

  • node1 — node1 is required: the field after propId is a positive integer.

Example record

UserDefined5;5;15;5;6;65.

Model containing this record

Reading the example gives id = 5, propId = 15.

UserDefined5Attributes

The attributes of the user dummy element number 5, whose connection is a UserDefined5 card and whose property is a UserDefined5Prop card.

Record format and fields

UserDefined5Attributes;nodeCount;connectionFieldCount;propertyFieldCount;displacementComponentCount;elementName

Position

Field

Type

Default

Meaning and conventions

1

nodeCount

integer

Required

Number of node entries.

2

connectionFieldCount

integer

0

Number of connection field entries.

3

propertyFieldCount

integer

0

Number of property field entries.

4

displacementComponentCount

integer

0

Number of displacement component entries.

5

elementName

text

—

Text naming the element.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • nodeCount — nodeCount must be a positive integer.

  • connectionFieldCount — connectionFieldCount must not be negative.

  • propertyFieldCount — propertyFieldCount must be an integer from 0 to 24.

  • displacementComponentCount — displacementComponentCount must be 0 (no differential stiffness), 3 or 6.

Example record

UserDefined5Attributes;2;1;2;0;UserDefined5

Model containing this record

Reading the example gives nodeCount = 2, connectionFieldCount = 1, propertyFieldCount = 2, displacementComponentCount = 0.

UserDefined5Prop

Supplies the property data for UserDefined5 elements. The user element determines the meaning of the property values.

Record format and fields

UserDefined5Prop;id;matId;<propertyFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

Repeated group propertyFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

propertyField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • propertyFields — the card has at most 24 additional fields.

Example record

UserDefined5Prop;15;1;1.;250.

Model containing this record

Reading the example gives id = 15, matId = 1.

Referenced records in this example

UserDefined6

The connection of a user dummy element of number 6, an element whose stiffness, mass and output are computed by routines the user links into the solver.

Record format and fields

UserDefined6;id;propId;<connectionFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

Repeated group connectionFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

connectionField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — id must be an integer from 1 to 99999999.

  • node1 — node1 is required: the field after propId is a positive integer.

Example record

UserDefined6;6;16;6;7;70.

Model containing this record

Reading the example gives id = 6, propId = 16.

UserDefined6Attributes

The attributes of the user dummy element number 6, whose connection is a UserDefined6 card and whose property is a UserDefined6Prop card.

Record format and fields

UserDefined6Attributes;nodeCount;connectionFieldCount;propertyFieldCount;displacementComponentCount;elementName

Position

Field

Type

Default

Meaning and conventions

1

nodeCount

integer

Required

Number of node entries.

2

connectionFieldCount

integer

0

Number of connection field entries.

3

propertyFieldCount

integer

0

Number of property field entries.

4

displacementComponentCount

integer

0

Number of displacement component entries.

5

elementName

text

—

Text naming the element.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • nodeCount — nodeCount must be a positive integer.

  • connectionFieldCount — connectionFieldCount must not be negative.

  • propertyFieldCount — propertyFieldCount must be an integer from 0 to 24.

  • displacementComponentCount — displacementComponentCount must be 0 (no differential stiffness), 3 or 6.

Example record

UserDefined6Attributes;2;1;2;0;UserDefined6

Model containing this record

Reading the example gives nodeCount = 2, connectionFieldCount = 1, propertyFieldCount = 2, displacementComponentCount = 0.

UserDefined6Prop

Supplies the property data for UserDefined6 elements. The user element determines the meaning of the property values.

Record format and fields

UserDefined6Prop;id;matId;<propertyFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

Repeated group propertyFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

propertyField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • propertyFields — the card has at most 24 additional fields.

Example record

UserDefined6Prop;16;1;1.;250.

Model containing this record

Reading the example gives id = 16, matId = 1.

Referenced records in this example

UserDefined7

The connection of a user dummy element of number 7, an element whose stiffness, mass and output are computed by routines the user links into the solver.

Record format and fields

UserDefined7;id;propId;<connectionFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

Repeated group connectionFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

connectionField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — id must be an integer from 1 to 99999999.

  • node1 — node1 is required: the field after propId is a positive integer.

Example record

UserDefined7;7;17;7;8;75.

Model containing this record

Reading the example gives id = 7, propId = 17.

UserDefined7Attributes

The attributes of the user dummy element number 7, whose connection is a UserDefined7 card and whose property is a UserDefined7Prop card.

Record format and fields

UserDefined7Attributes;nodeCount;connectionFieldCount;propertyFieldCount;displacementComponentCount;elementName

Position

Field

Type

Default

Meaning and conventions

1

nodeCount

integer

Required

Number of node entries.

2

connectionFieldCount

integer

0

Number of connection field entries.

3

propertyFieldCount

integer

0

Number of property field entries.

4

displacementComponentCount

integer

0

Number of displacement component entries.

5

elementName

text

—

Text naming the element.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • nodeCount — nodeCount must be a positive integer.

  • connectionFieldCount — connectionFieldCount must not be negative.

  • propertyFieldCount — propertyFieldCount must be an integer from 0 to 24.

  • displacementComponentCount — displacementComponentCount must be 0 (no differential stiffness), 3 or 6.

Example record

UserDefined7Attributes;2;1;2;0;UserDefined7

Model containing this record

Reading the example gives nodeCount = 2, connectionFieldCount = 1, propertyFieldCount = 2, displacementComponentCount = 0.

UserDefined7Prop

Supplies the property data for UserDefined7 elements. The user element determines the meaning of the property values.

Record format and fields

UserDefined7Prop;id;matId;<propertyFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

Repeated group propertyFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

propertyField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • propertyFields — the card has at most 24 additional fields.

Example record

UserDefined7Prop;17;1;1.;250.

Model containing this record

Reading the example gives id = 17, matId = 1.

Referenced records in this example

UserDefined8

The connection of a user dummy element of number 8, an element whose stiffness, mass and output are computed by routines the user links into the solver.

Record format and fields

UserDefined8;id;propId;<connectionFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

Repeated group connectionFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

connectionField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — id must be an integer from 1 to 99999999.

  • node1 — node1 is required: the field after propId is a positive integer.

Example record

UserDefined8;8;18;8;9;80.

Model containing this record

Reading the example gives id = 8, propId = 18.

UserDefined8Attributes

The attributes of the user dummy element number 8, whose connection is a UserDefined8 card and whose property is a UserDefined8Prop card.

Record format and fields

UserDefined8Attributes;nodeCount;connectionFieldCount;propertyFieldCount;displacementComponentCount;elementName

Position

Field

Type

Default

Meaning and conventions

1

nodeCount

integer

Required

Number of node entries.

2

connectionFieldCount

integer

0

Number of connection field entries.

3

propertyFieldCount

integer

0

Number of property field entries.

4

displacementComponentCount

integer

0

Number of displacement component entries.

5

elementName

text

—

Text naming the element.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • nodeCount — nodeCount must be a positive integer.

  • connectionFieldCount — connectionFieldCount must not be negative.

  • propertyFieldCount — propertyFieldCount must be an integer from 0 to 24.

  • displacementComponentCount — displacementComponentCount must be 0 (no differential stiffness), 3 or 6.

Example record

UserDefined8Attributes;18;0;5;0;CrackTip2D

Model containing this record

Reading the example gives nodeCount = 18, connectionFieldCount = 0, propertyFieldCount = 5, displacementComponentCount = 0.

UserDefined8Prop

Supplies the property data for UserDefined8 elements. The user element determines the meaning of the property values.

Record format and fields

UserDefined8Prop;id;matId;<propertyFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

Repeated group propertyFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

propertyField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • propertyFields — the card has at most 24 additional fields.

Example record

UserDefined8Prop;18;1;1.;250.

Model containing this record

Reading the example gives id = 18, matId = 1.

Referenced records in this example

UserDefined9

The connection of a user dummy element of number 9, an element whose stiffness, mass and output are computed by routines the user links into the solver.

Record format and fields

UserDefined9;id;propId;<connectionFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

Repeated group connectionFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

connectionField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — id must be an integer from 1 to 99999999.

  • node1 — node1 is required: the field after propId is a positive integer.

Example record

UserDefined9;9;19;9;10;85.

Model containing this record

Reading the example gives id = 9, propId = 19.

UserDefined9Attributes

The attributes of the user dummy element number 9, whose connection is a UserDefined9 card and whose property is a UserDefined9Prop card.

Record format and fields

UserDefined9Attributes;nodeCount;connectionFieldCount;propertyFieldCount;displacementComponentCount;elementName

Position

Field

Type

Default

Meaning and conventions

1

nodeCount

integer

Required

Number of node entries.

2

connectionFieldCount

integer

0

Number of connection field entries.

3

propertyFieldCount

integer

0

Number of property field entries.

4

displacementComponentCount

integer

0

Number of displacement component entries.

5

elementName

text

—

Text naming the element.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • nodeCount — nodeCount must be a positive integer.

  • connectionFieldCount — connectionFieldCount must not be negative.

  • propertyFieldCount — propertyFieldCount must be an integer from 0 to 24.

  • displacementComponentCount — displacementComponentCount must be 0 (no differential stiffness), 3 or 6.

Example record

UserDefined9Attributes;64;0;6;0;CrackTip3D

Model containing this record

Reading the example gives nodeCount = 64, connectionFieldCount = 0, propertyFieldCount = 6, displacementComponentCount = 0.

UserDefined9Prop

Supplies the property data for UserDefined9 elements. The user element determines the meaning of the property values.

Record format and fields

UserDefined9Prop;id;matId;<propertyFields>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the property namespace.

2

matId

integer

Required

Material identifier used to retrieve the constitutive data.

Repeated group propertyFields. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

propertyField

number

—

Positional input to the selected entry. Its interpretation is defined by the entry type or user routine.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • propertyFields — the card has at most 24 additional fields.

Example record

UserDefined9Prop;19;1;1.;250.

Model containing this record

Reading the example gives id = 19, matId = 1.

Referenced records in this example

ViscousDamper2

A viscous damper between two grid points, with a ViscousDamperProp property.

Record format and fields

ViscousDamper2;id;propId;node1;node2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

node1

integer

Required

Identifier addressing node data.

4

node2

integer

Required

Identifier addressing node data.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • node1 — the grid point IDs must be positive integers.

  • node2 — node1 and node2 must be different.

Example record

ViscousDamper2;7;7;2;3

Model containing this record

Reading the example gives id = 7, propId = 7, node1 = 2, node2 = 3.

Referenced records in this example

  • Node via node1 = 2, node2 = 3.

Weld

A weld or fastener between two surface patches, a point and a patch, or two points.

Record format and fields

Forms: partPattern, elementPattern, elementIds, gridIds, align.

Weld: partPattern

Form partPattern, when kind is PartPatch.

Weld;id;propId;spotNode;kind;nodeA;nodeB;matFrameId;propIdA;propIdB;locationX;locationY;locationZ

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

spotNode

integer

0

Identifier addressing node data.

4

kind

text

—

Selects the kind for Weld.

5

nodeA

integer

0

Identifier addressing node data.

6

nodeB

integer

0

Identifier addressing node data.

7

matFrameId

integer

-1

Coordinate system defining the material directions.

8

propIdA

integer

—

Identifier of the property on side A.

9

propIdB

integer

—

Identifier of the property on side B.

10

locationX

real

—

X coordinate of the location.

11

locationY

real

—

Y coordinate of the location.

12

locationZ

real

—

Z coordinate of the location.

Weld: elementPattern

Form elementPattern, when kind is ElemPatch.

Weld;id;propId;spotNode;kind;nodeA;nodeB;matFrameId;shellIdA;shellIdB;locationX;locationY;locationZ

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

spotNode

integer

0

Identifier addressing node data.

4

kind

text

—

Selects the kind for Weld.

5

nodeA

integer

0

Identifier addressing node data.

6

nodeB

integer

0

Identifier addressing node data.

7

matFrameId

integer

-1

Coordinate system defining the material directions.

8

shellIdA

integer

—

Identifier of the shell on side A.

9

shellIdB

integer

—

Identifier of the shell on side B.

10

locationX

real

—

X coordinate of the location.

11

locationY

real

—

Y coordinate of the location.

12

locationZ

real

—

Z coordinate of the location.

Weld: elementIds

Form elementIds, when kind is ElemIdPatch.

Weld;id;propId;spotNode;kind;nodeA;nodeB;matFrameId;shellIdA;shellIdB

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

spotNode

integer

0

Identifier addressing node data.

4

kind

text

—

Selects the kind for Weld.

5

nodeA

integer

0

Identifier addressing node data.

6

nodeB

integer

0

Identifier addressing node data.

7

matFrameId

integer

-1

Coordinate system defining the material directions.

8

shellIdA

integer

—

Identifier of the shell on side A.

9

shellIdB

integer

0

Identifier of the shell on side B.

Weld: gridIds

Form gridIds, when kind is NodeIdPatch.

Weld;id;propId;spotNode;kind;nodeA;nodeB;patchShapes;matFrameId;nodeA1;nodeA2;nodeA3;nodeA4;nodeA5;nodeA6;nodeA7;nodeA8;nodeB1;nodeB2;nodeB3;nodeB4;nodeB5;nodeB6;nodeB7;nodeB8

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

spotNode

integer

0

Identifier addressing node data.

4

kind

text

—

Selects the kind for Weld.

5

nodeA

integer

0

Identifier addressing node data.

6

nodeB

integer

0

Identifier addressing node data.

7

patchShapes

text

—

Selects the shapes used to represent the paired attachment patches.

8

matFrameId

integer

-1

Coordinate system defining the material directions.

9

nodeA1

integer

0

Identifier addressing node data.

10

nodeA2

integer

0

Identifier of the grid point on side A at position 2.

11

nodeA3

integer

0

Identifier of the grid point on side A at position 3.

12

nodeA4

integer

0

Identifier of the grid point on side A at position 4.

13

nodeA5

integer

0

Identifier of the grid point on side A at position 5.

14

nodeA6

integer

0

Identifier of the grid point on side A at position 6.

15

nodeA7

integer

0

Identifier of the grid point on side A at position 7.

16

nodeA8

integer

0

Identifier of the grid point on side A at position 8.

17

nodeB1

integer

0

Identifier of the grid point on side B at position 1.

18

nodeB2

integer

0

Identifier of the grid point on side B at position 2.

19

nodeB3

integer

0

Identifier of the grid point on side B at position 3.

20

nodeB4

integer

0

Identifier of the grid point on side B at position 4.

21

nodeB5

integer

0

Identifier of the grid point on side B at position 5.

22

nodeB6

integer

0

Identifier of the grid point on side B at position 6.

23

nodeB7

integer

0

Identifier of the grid point on side B at position 7.

24

nodeB8

integer

0

Identifier of the grid point on side B at position 8.

Weld: align

Form align, for every other record.

Weld;id;propId;spotNode;kind;nodeA;nodeB;matFrameId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the element namespace.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

spotNode

integer

0

Identifier addressing node data.

4

kind

text

—

Selects the kind for Weld.

5

nodeA

integer

0

Identifier addressing node data.

6

nodeB

integer

0

Identifier addressing node data.

7

matFrameId

integer

-1

Coordinate system defining the material directions.

Accepted words: AlignedNodes, ElemIdPatch, ElemPatch, NodeIdPatch, PartPatch, QuadPatch, QuadQuadPatch, QuadTriaPatch, TriaPatch, TriaQuadPatch, TriaTriaPatch.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer.

  • propId — the property ID must be a positive integer.

  • kind — kind must be PartPatch, ElemPatch, ElemIdPatch, NodeIdPatch or AlignedNodes.

  • spotNode — spotNode, nodeA and nodeB must be 0 (blank) or grid point IDs.

  • matFrameId — matFrameId must be -1 or a coordinate system ID.

  • patchShapes — nodeA1 to nodeB8 and patchShapes belong to the NodeIdPatch format.

  • nodeB — nodeA and nodeB must be different.

  • patchShapes — patchShapes must be QuadQuadPatch, QuadTriaPatch, TriaTriaPatch, TriaQuadPatch, QuadPatch or TriaPatch.

  • nodeA1 — the grid point IDs must not be negative.

  • nodeB1 — nodeB1, nodeB2 and nodeB3 are required for a patch to patch connection.

  • patchIdA — the first patch (propIdA or shellIdA) must be a positive integer.

  • patchIdB — shellIdB must be 0 (blank) or an element ID.

  • patchIdB — the second patch (propIdB or shellIdB) must be a positive integer.

  • patchIdB — the two patches must be different.

  • locationX — locationX, locationY and locationZ must be all given or all blank.

Example record

Weld;1001;2;901;PartPatch;;;;11;12