Points and geometry

All card families and alphabetical index

Read field positions from left to right within each table. A dash means the layout supplies no fixed default. Use a consistent system of units for dimensional quantities.

AcousticSlotControl

Defines the harmonic index and default fluid properties for an acoustic cavity represented by slots.

Record format and fields

AcousticSlotControl;defaultDensity;defaultBulkModulus;harmonic;defaultSlotWidth;defaultSlotCount

Position

Field

Type

Default

Meaning and conventions

1

defaultDensity

real

—

Density used when the corresponding input leaves its density unspecified.

2

defaultBulkModulus

real

—

Default bulk modulus (force per area).

3

harmonic

integer

—

Index identifying the spatial or temporal harmonic.

4

defaultSlotWidth

real

—

Default slot width (length).

5

defaultSlotCount

integer

—

Number of default slot entries.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • harmonic — harmonic must not be negative.

  • defaultSlotCount — defaultSlotCount must not be negative.

Example record

AcousticSlotControl;1.2E-12;0.142;0;5.;6

Model containing this record

Reading the example gives defaultDensity = 1.2E-12, defaultBulkModulus = 0.142, harmonic = 0, defaultSlotWidth = 5..

AcousticSlotFluidPoint

An axisymmetric fluid point of the acoustic cavity (slot) analysis, a scalar degree of freedom (the pressure) with a two-dimensional location.

Record format and fields

AcousticSlotFluidPoint;id;radius;zCoord

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the node namespace.

2

radius

real

Required

Radial dimension measured from the centre or axis (length).

3

zCoord

real

Required

Z coordinate of the location in the specified frame.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the ID must be an integer from 1 to 999999.

Example record

AcousticSlotFluidPoint;1;25.;0.

Model containing this record

Reading the example gives id = 1, radius = 25., zCoord = 0..

AcousticSlotSurfacePoint

A slot surface point of the acoustic cavity (slot) analysis, a scalar degree of freedom (the pressure) with a two-dimensional location and a slot width.

Record format and fields

AcousticSlotSurfacePoint;id;radius;zCoord;slotWidth;fluidPointId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the node namespace.

2

radius

real

Required

Radial dimension measured from the centre or axis (length).

3

zCoord

real

Required

Z coordinate of the location in the specified frame.

4

slotWidth

real

—

Slot width (length).

5

fluidPointId

integer

0

Identifier addressing node data.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • radius — radius must not be zero.

Example record

AcousticSlotSurfacePoint;21;50.;0.;;11

Model containing this record

Reading the example gives id = 21, radius = 50., zCoord = 0., fluidPointId = 11.

Referenced records in this example

AdaptiveRefineControl

The control of the local adaptive mesh refinement for one criterion.

Record format and fields

AdaptiveRefineControl;id;repeatCount;criterionId;regionMethod;regionId;snapMethod;maximumLevel

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

repeatCount

integer

—

Number of repetitions of the defined event or block.

3

criterionId

integer

Required

Identifier selecting the criterion record or set.

4

regionMethod

text

—

Selects the region method for AdaptiveRefineControl.

5

regionId

integer

0

Identifier of the region on which the definition acts.

6

snapMethod

integer

—

Selects the snap method for AdaptiveRefineControl.

7

maximumLevel

integer

same as repeatCount

Deepest allowed level of the specified hierarchy or refinement.

Accepted words: All, Constant, Element, Property, Superelement, Table, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • repeatCount — repeatCount must not be negative.

  • snapMethod — snapMethod must be 0 or 1.

Example record

AdaptiveRefineControl;1;2;1;All;;0;2

Model containing this record

Reading the example gives id = 1, repeatCount = 2, criterionId = 1, regionMethod = All.

AdaptiveRefineCriterion

A criterion that picks the elements to refine in the adaptive mesh refinement.

Record format and fields

AdaptiveRefineCriterion;id;kind;parameter1;parameter2;parameter3;parameter4;parameter5;parameter6

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

kind

integer

—

Selects the kind for AdaptiveRefineCriterion.

3

parameter1

real

—

Parameter 1 of the selected refinement criterion; its meaning follows the criterion.

4

parameter2

real

—

Parameter 2 of the selected refinement criterion; its meaning follows the criterion.

5

parameter3

real

—

Parameter 3 of the selected refinement criterion; its meaning follows the criterion.

6

parameter4

real

—

Parameter 4 of the selected refinement criterion; its meaning follows the criterion.

7

parameter5

real

—

Parameter 5 of the selected refinement criterion; its meaning follows the criterion.

8

parameter6

real

—

Parameter 6 of the selected refinement criterion; its meaning follows the criterion.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • kind — kind must be 1, 2, 3 or 4.

Example record

AdaptiveRefineCriterion;2;2;0.;0.;0.;15.

Model containing this record

Reading the example gives id = 2, kind = 2, parameter1 = 0., parameter2 = 0..

AssociativeNode

Associates a grid point with the assembly step that combines model parts.

Record format and fields

AssociativeNode;id;origNodeId;partitionName

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the node namespace.

2

origNodeId

integer

Required

Identifier selecting the orig node record or set.

3

partitionName

text

—

Text naming the partition. Written as one text field.

Accepted words: Constant, Element, Table.

Example record

AssociativeNode;101;1000;LEFT_WING_TANK

Model containing this record

Reading the example gives id = 101, origNodeId = 1000, partitionName = LEFT_WING_TANK.

AxisymConeControl

Identifies the model as an axisymmetric conical shell system using rings, shell elements and ring loads.

Record format and fields

AxisymConeControl;highestHarmonic

Position

Field

Type

Default

Meaning and conventions

1

highestHarmonic

integer

Required

Largest harmonic index included in the representation.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • highestHarmonic — highestHarmonic must be an integer from 0 to 997.

Example record

AxisymConeControl;2

Model containing this record

Reading the example gives highestHarmonic = 2.

AxisymConePoint

Defines a point on a conical shell ring for concentrated loads and displacement recovery.

Record format and fields

AxisymConePoint;id;ringId;phiAngle

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the node namespace.

2

ringId

integer

Required

Identifier addressing node data.

3

phiAngle

real

Required

Angular coordinate or orientation denoted by phi in the local geometry.

Accepted words: Constant, Element, Table.

Example record

AxisymConePoint;51;5;0.

Model containing this record

Reading the example gives id = 51, ringId = 5, phiAngle = 0..

Referenced records in this example

AxisymConeRing

A ring of a conical shell model (an axisymmetric structure described by harmonics).

Record format and fields

AxisymConeRing;id;radius;zCoord;permanentConstraints

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the node namespace.

2

radius

real

Required

Radial dimension measured from the centre or axis (length).

3

zCoord

real

Required

Z coordinate of the location in the specified frame.

4

permanentConstraints

integer

0

0 = no permanent constraint.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • permanentConstraints — permanentConstraints must be digits 1 to 6 with no repeat.

Example record

AxisymConeRing;1;100.;0.;123456

Model containing this record

Reading the example gives id = 1, radius = 100., zCoord = 0., permanentConstraints = 123456.

AxisymFluidControl

The basic parameters and the existence of an axisymmetric fluid analysis, with the harmonics of the solution.

Record format and fields

AxisymFluidControl;frameId;gravity;defaultDensity;defaultBulkModulus;nonsymmetric;noHarmonicsFlag;<harmonics>

Position

Field

Type

Default

Meaning and conventions

1

frameId

integer

Required

Coordinate system in which this entry is expressed.

2

gravity

real

Required

Acceleration of gravity used by the definition, in length per time squared.

3

defaultDensity

real

—

Density used when the corresponding input leaves its density unspecified.

4

defaultBulkModulus

real

—

Default bulk modulus (force per area).

5

nonsymmetric

text

—

Specifies whether the two sides or matrix halves are treated separately.

6

noHarmonicsFlag

text

—

Selects the no harmonics flag for AxisymFluidControl.

Repeated group harmonics. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

harmonic

any

—

Index identifying the spatial or temporal harmonic.

Accepted words: Constant, Element, No, None, Step, Table, Through, Yes.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • harmonic — a harmonic must be an integer from 0 to 99.

  • lastHarmonic — the end of a range must be above its start and at most 99.

  • harmonicStep — harmonicStep must be a positive integer.

  • harmonic — the harmonics must be in increasing order.

Example record

AxisymFluidControl;1;9810.;1.E-9;2200.;No;;0;2

Model containing this record

Reading the example gives frameId = 1, gravity = 9810., defaultDensity = 1.E-9, defaultBulkModulus = 2200..

AxisymFluidFreePoint

A point on the free surface of an axisymmetric fluid at which the surface displacements are recovered.

Record format and fields

In the source layout, the form is called pairsFromSlot3 when field 2 of the old layout is blank. Its compact field sequence is the one shown below.

Forms: pairsFromSlot2.

AxisymFluidFreePoint: pairsFromSlot2

Form pairsFromSlot2, for every compact record.

AxisymFluidFreePoint;fluidPointId;<points>

Position

Field

Type

Default

Meaning and conventions

1

fluidPointId

integer

Required

Identifier addressing node data.

Repeated group points. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

pointId

integer

—

Identifier of the point to which this entry applies.

2

phiAngle

real

—

Angular coordinate or orientation denoted by phi in the local geometry.

Note: at most three pairs.

Accepted words: Constant, Element, Table.

Example record

AxisymFluidFreePoint;5;501;0.;502;45.

Model containing this record

AxisymFluidPressurePoint

A point of an axisymmetric fluid at which the pressure is recovered, and that may also measure pressure for a control device.

Record format and fields

In the source layout, the form is called pairsFromSlot3 when field 2 of the old layout is blank. Its compact field sequence is the one shown below.

Forms: pairsFromSlot2.

AxisymFluidPressurePoint: pairsFromSlot2

Form pairsFromSlot2, for every compact record.

AxisymFluidPressurePoint;fluidPointId;<points>

Position

Field

Type

Default

Meaning and conventions

1

fluidPointId

integer

Required

Identifier addressing node data.

Repeated group points. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

pointId

integer

—

Identifier of the point to which this entry applies.

2

phiAngle

real

—

Angular coordinate or orientation denoted by phi in the local geometry.

Note: at most three pairs.

Accepted words: Constant, Element, Table.

Example record

AxisymFluidPressurePoint;3;301;0.;302;45.

Model containing this record

AxisymFluidRing

A circle of an axisymmetric fluid model.

Record format and fields

AxisymFluidRing;firstId;firstPosition1;firstPosition2;firstPosition3;secondId;secondPosition1;secondPosition2;secondPosition3

Position

Field

Type

Default

Meaning and conventions

1

firstId

integer

—

Identifier selecting the first record or set.

2

firstPosition1

real

—

Coordinate 1 of the first position in the specified frame.

3

firstPosition2

real

0.0

Coordinate 2 of the first position in the specified frame.

4

firstPosition3

real

0.0

Coordinate 3 of the first position in the specified frame.

5

secondId

integer

—

Identifier selecting the second record or set.

6

secondPosition1

real

—

Coordinate 1 of the second position in the specified frame.

7

secondPosition2

real

0.0

Coordinate 2 of the second position in the specified frame.

8

secondPosition3

real

0.0

Coordinate 3 of the second position in the specified frame.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — id must be an integer from 1 to 499999.

Example record

AxisymFluidRing;1;50.;;0.;2;100.;;0.

Model containing this record

Reading the example gives firstId = 1, firstPosition1 = 50., firstPosition3 = 0., secondId = 2.

AxisymFluidRingNode

A grid point on a fluid ring (AxisymFluidRing) of an axisymmetric model.

Record format and fields

AxisymFluidRingNode;id;phiAngle;displacementFrameId;permanentConstraints;fluidPointId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the node namespace.

2

phiAngle

real

Required

Angular coordinate or orientation denoted by phi in the local geometry.

3

displacementFrameId

integer

0

Coordinate system in which the displacement components are expressed.

4

permanentConstraints

integer

0

Permanent single-point constraints, as digits 1..6 (0 = none).

5

fluidPointId

integer

Required

Identifier addressing node data.

Accepted words: AxisymFluidRing.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the ID must be a positive integer.

  • displacementFrameId — displacementFrameId must be 0 or a coordinate system ID.

  • permanentConstraints — permanentConstraints must be digits 1 to 6 with no repeat.

Example record

AxisymFluidRingNode;401;0.;1;246;4

Model containing this record

Reading the example gives id = 401, phiAngle = 0., displacementFrameId = 1, permanentConstraints = 246.

Referenced records in this example

ExtraPoint

Introduces an additional scalar degree of freedom for a dynamic model.

Record format and fields

ExtraPoint;<ids>

This part of the record has no fixed fields.

Repeated group ids. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

id

any

—

Identifier in the node namespace.

Accepted words: Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the extra point ID must be a positive integer.

Example record

ExtraPoint;4001;4011;4012

Model containing this record

GeomPoint

A geometric point that is not a grid point (an edge point for SuperelementLocation, a profile point of a BeamArbitrarySectionProp).

Record format and fields

GeomPoint;id;positionFrameId;position1;position2;position3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the node namespace.

2

positionFrameId

integer

0

Coordinate system used to interpret the position coordinates.

3

position1

real

0.0

Coordinate 1 of the specified location in its reference frame.

4

position2

real

0.0

Coordinate 2 of the specified location in its reference frame.

5

position3

real

0.0

Coordinate 3 of the specified location in its reference frame.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the ID must be a positive integer.

  • positionFrameId — positionFrameId must be 0 or a coordinate system ID.

Example record

GeomPoint;941;;0.;0.;0.

Model containing this record

Reading the example gives id = 941, position1 = 0., position2 = 0., position3 = 0..

ModuleBolt

Defines a pretensioned bolt spanning modules. A control point couples pairs of grid points on opposite sides of its cut.

Record format and fields

ModuleBolt;id;controlNode;controlModuleId;topModuleId;bottomModuleId;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

controlNode

integer

Required

Identifier of the grid point through which this definition is controlled.

3

controlModuleId

integer

0

Identifier selecting the control module record or set.

4

topModuleId

integer

0

Identifier selecting the top module record or set.

5

bottomModuleId

integer

0

Identifier selecting the bottom module record or set.

Keyed sections in lists

Begin each section with its key, then write its fixed fields and any counted list.

Section Top

Repeated group topNodes. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

topNode

integer

—

Grid point defining the top side of the connection.

Section Bottom

Repeated group bottomNodes. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

bottomNode

integer

—

Grid point defining the bottom side of the connection.

Accepted words: All, Bottom, Constant, Element, Table, Through, Top.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • topList — the bolt needs grid points in topList.

  • bottomList — the bolt needs grid points in bottomList.

Example record

ModuleBolt;309;70;0;1;2;Top;2;103;107;Bottom;2;203;207

Model containing this record

Reading the example gives id = 309, controlNode = 70, controlModuleId = 0, topModuleId = 1.

ModuleBoundaryNodes

The grid points of a module that the automatic search of the boundary with another module, or with all the others, is limited to.

Record format and fields

ModuleBoundaryNodes;moduleIdA;otherModule;<nodes>

Position

Field

Type

Default

Meaning and conventions

1

moduleIdA

integer

0

Identifier of the module on side A.

2

otherModule

any

—

Identifier of the module on the other side of the operation.

Repeated group nodes. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

nodeA

any

—

Grid point identifier at connectivity position A.

Accepted words: All, Through.

Example record

ModuleBoundaryNodes;1;0;101;104;107

Model containing this record

Reading the example gives moduleIdA = 1, otherModule = 0.

ModuleBrakeSystem

The data of a brake system for brake squeal calculations with one wheel or several, on one axis or several, in different modules.

Record format and fields

ModuleBrakeSystem;id;squealLoadFactor;frictionVectorMethod;squealOnly;contactMethod;<disks>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

squealLoadFactor

real

0.0

Multiplier for squeal load.

3

frictionVectorMethod

integer

0

Selects the friction vector method for ModuleBrakeSystem.

4

squealOnly

text

—

Restricts the option to the brake-squeal analysis when selected.

5

contactMethod

integer

0

Selects the contact method for ModuleBrakeSystem.

Repeated group disks. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

diskName

text

—

Text naming the disk.

2

moduleId1

integer

—

Identifier selecting the module record or set.

3

body1Id

integer

—

Identifier selecting the body 1 record or set.

4

moduleId2

integer

—

Identifier selecting the module record or set.

5

body2Id

integer

—

Identifier selecting the body 2 record or set.

6

motion1Id

integer

—

Identifier selecting the motion 1 record or set.

7

motion2Id

integer

—

Identifier selecting the motion 2 record or set.

8

brakeSystemId

integer

—

Identifier selecting the brake system record or set.

Accepted words: All, Constant, Element, No, Table, Through, Yes.

Example record

ModuleBrakeSystem;1;1.;0;No;0;DISK1;1;1;0;2;1;;1

Model containing this record

Reading the example gives id = 1, squealLoadFactor = 1., frictionVectorMethod = 0, squealOnly = No.

ModuleBulkOptions

The type of a module and how the boundary between modules is searched.

Record format and fields

ModuleBulkOptions;id;kind;sourceModuleId;method;tolerance;unitNumber

Position

Field

Type

Default

Meaning and conventions

1

id

any

—

Identifier in the namespace of this card type.

2

kind

text

—

Selects the kind for ModuleBulkOptions.

3

sourceModuleId

integer

0

Identifier selecting the source module record or set.

4

method

text

—

Selects the method for ModuleBulkOptions.

5

tolerance

real

0.0

Allowable change or residual for the selected numerical check.

6

unitNumber

integer

0

Logical file unit used to identify an external resource.

Accepted words: All, Automatic, Constant, Element, External, ExternalBinaryResults, ExternalMatrixFile, Manual, Mirror, Move, Primary, Repeat, Table, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • sourceModuleId — sourceModuleId must be zero or a positive module number.

  • unitNumber — unitNumber must be zero or a positive unit number.

Example record

ModuleBulkOptions;4;Move;1;Automatic

Model containing this record

Reading the example gives id = 4, kind = Move, sourceModuleId = 1, method = Automatic.

ModuleBushing

A generalized spring-and-damper element whose end points may lie in different modules; the rules of the Bushing apply to it.

Record format and fields

ModuleBushing;id;propId;nodeA;nodeB;position1;orientationNode;position2;position3;frameId;offsetFraction;offsetFrameId;offset1;offset2;offset3;moduleIdA;moduleIdB;orientationModuleId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

nodeA

integer

Required

Grid point identifier at connectivity position A.

4

nodeB

integer

0

Grid point identifier at connectivity position B.

5

position1

real

—

Coordinate 1 of the specified location in its reference frame. Alternative to orientationNode.

6

orientationNode

integer

—

Grid point defining the orientation direction in place of explicit vector components. Alternative to position1.

7

position2

real

0.0

Coordinate 2 of the specified location in its reference frame.

8

position3

real

0.0

Coordinate 3 of the specified location in its reference frame.

9

frameId

integer

—

Coordinate system in which this entry is expressed.

10

offsetFraction

real

0.5

Offset expressed as a fraction of the associated reference dimension or range.

11

offsetFrameId

integer

-1

Identifier selecting the offset frame record or set.

12

offset1

real

0.0

Shift from the reference location or value in the convention of this entry. Entry 1.

13

offset2

real

0.0

Shift from the reference location or value in the convention of this entry. Entry 2.

14

offset3

real

0.0

Shift from the reference location or value in the convention of this entry. Entry 3.

15

moduleIdA

integer

0

Identifier of the module on side A.

16

moduleIdB

integer

0

Identifier of the module on side B.

17

orientationModuleId

integer

0

Identifier selecting the orientation module record or set.

Accepted words: All, Constant, Element, Table, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be a positive integer below 100 000 000.

  • nodeB — nodeB must be 0 (blank) or a grid point ID.

  • orientationNode — orientationNode must be a positive grid point ID.

  • frameId — frameId must be blank or a coordinate system ID.

  • offsetFrameId — offsetFrameId must be -1 or a coordinate system ID.

Example record

ModuleBushing;305;34;111;211;;;;;0;;;;;;1;2

Model containing this record

Reading the example gives id = 305, propId = 34, nodeA = 111, nodeB = 211.

ModuleConnection

How the boundary points of the modules are connected at a location.

Record format and fields

ModuleConnection;id;kind;tolerance;xCoord;locationNode;yCoord;zCoord;moduleId;frameId;<points>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

kind

text

—

Selects the kind for ModuleConnection.

3

tolerance

real

0.0

Allowable change or residual for the selected numerical check.

4

xCoord

real

0.0

X coordinate of the location in the specified frame. Alternative to locationNode.

5

locationNode

integer

—

Grid point defining the location of the operation. Alternative to xCoord.

6

yCoord

real

0.0

Y coordinate of the location in the specified frame.

7

zCoord

real

0.0

Z coordinate of the location in the specified frame.

8

moduleId

integer

0

Identifier selecting the module record or set.

9

frameId

integer

0

Coordinate system in which this entry is expressed.

Repeated group points. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

memberModuleId

integer

—

Identifier selecting the member module record or set.

2

memberNodeId

integer

—

Identifier selecting the member node record or set.

Accepted words: All, Constant, Element, Merge, ModuleRigidStar, Rigid, RigidStarReleased, Table, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • frameId — frameId must be zero or a positive coordinate system ID.

  • locationNode — locationNode must be a positive grid point ID.

  • memberNodeId — memberNodeId must be zero (every grid point of the module) or a point ID.

Example record

ModuleConnection;21;Rigid;0.001;0.;;40.;0.;;;2;201;4;109

Model containing this record

Reading the example gives id = 21, kind = Rigid, tolerance = 0.001, xCoord = 0..

ModuleContactCandidates

The modules that are candidates for the automatic detection of contact across modules.

Record format and fields

ModuleContactCandidates;moduleSetId;<pairs>

Position

Field

Type

Default

Meaning and conventions

1

moduleSetId

integer

-1

Identifier selecting the module set record or set.

Repeated group pairs. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

firstModuleId

integer

—

Identifier selecting the first module record or set.

2

secondModuleId

integer

—

Identifier selecting the second module record or set.

Accepted words: Constant, Element, Table, TypedListSet3.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • moduleId — a module number must not be negative.

Example record

ModuleContactCandidates;0;1;2

Model containing this record

Reading the example gives moduleSetId = 0.

ModuleContactDetectParams

The parameters that detect contact pairs between bodies that lie in different modules when the contact is generated automatically, as (name, value) pairs.

Record format and fields

ModuleContactDetectParams;<parameters>

This part of the record has no fixed fields.

Repeated group parameters. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

any

—

Value assigned to the named parameter. Its interpretation depends on that name.

Accepted words: BilinearCoulomb, Both, Full, GeneralGlue, No, NodeToSurface, Off, On, PermanentGlue, SegmentToSegment, StandardGlue, TouchOnly, Yes.

Accepted parameter names: BeamContact, ContactKind, DeleteSolids, DetectionDistance, EdgeContact, FrictionCoefficient, FrictionKind, IgnoreThickness, InitialStiffness, SelfContact.

Example record

ModuleContactDetectParams;ContactKind;PermanentGlue;DetectionDistance;3.

Model containing this record

ModuleContactPair

A contact pair whose touching and touched bodies lie in different modules: general contact, glued, step glued or permanently glued.

Record format and fields

ModuleContactPair;id;geometricParamsId;physicalParamsId;secondaryModule;secondaryBodyId;primaryModule;primaryBodyId;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

geometricParamsId

integer

0

Identifier selecting the geometric params record or set.

3

physicalParamsId

integer

0

Identifier selecting the physical params record or set.

4

secondaryModule

integer

0

Module containing the secondary side of the connection.

5

secondaryBodyId

integer

0

Identifier selecting the secondary body record or set.

6

primaryModule

integer

0

Module containing the primary side of the connection.

7

primaryBodyId

integer

0

Identifier selecting the primary body record or set.

Keyed sections in lists

Begin each section with its key, then write its fixed fields and any counted list.

Section Secondary

Repeated group secondaryBodies. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

secondaryListModule

integer

—

Module containing the list of secondary entities.

2

secondaryListBodyId

integer

—

Identifier selecting the secondary list body record or set.

Section Primary

Repeated group primaryBodies. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

primaryListModule

integer

—

Module containing the list of primary entities.

2

primaryListBodyId

integer

—

Identifier selecting the primary list body record or set.

Accepted words: Constant, Element, Primary, Secondary, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the id must not be negative.

Example record

ModuleContactPair;1;7;;2;2;1;1

Model containing this record

Reading the example gives id = 1, geometricParamsId = 7, secondaryModule = 2, secondaryBodyId = 2.

ModuleContactTable

Selects interactions involving bodies in different modules using their contact definitions.

Record format and fields

ModuleContactTable;id;<pairs>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group pairs. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

module

integer

—

Identifier of the model part owning the selected entities.

2

contactPairId

integer

—

Identifier selecting the contact pair record or set.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — id must not be negative.

Example record

ModuleContactTable;10;;1

Model containing this record

Reading the example gives id = 10.

ModuleDirectMatrix

The header of a matrix of direct input at points of several modules, or one column of it.

Record format and fields

ModuleDirectMatrix;entryName;columnModuleId;matrixShapeOrNodeJ;inputTypeOrComponentsJ;outputType;polarFlag;columnCount;<terms>

Position

Field

Type

Default

Meaning and conventions

1

entryName

text

—

Name identifying the associated item in the list.

2

columnModuleId

integer

0

Identifier selecting the column module record or set.

3

matrixShapeOrNodeJ

integer

—

Selects the matrix shape for a header or the column grid point for a data record.

4

inputTypeOrComponentsJ

integer

—

Input numeric representation in a matrix header or column point components in a data record.

5

outputType

integer

0

Selects the output type for ModuleDirectMatrix.

6

polarFlag

integer

0

Selects the polar flag for ModuleDirectMatrix.

7

columnCount

integer

0

Number of column entries.

Repeated group terms. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

moduleId

integer

—

Identifier selecting the module record or set.

2

node

integer

—

Grid point to which this entry applies.

3

components

integer

—

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations.

4

realValue

real

—

Real scalar value or real part of the complex quantity.

5

imaginaryValue

real

—

Imaginary part paired with the real component.

Accepted words: All, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • entryName — entryName must be a nonempty matrix name without control characters.

  • matrixShape — matrixShape must be 1 (square), 2 or 9 (rectangular) or 6 (symmetric).

  • inputType — inputType must be 1, 2, 3 or 4.

  • outputType — outputType must be 0, 1, 2, 3 or 4.

  • polarFlag — polarFlag must not be negative.

  • columnCount — columnCount must not be negative.

  • imaginaryValue — a header card has no terms and no imaginaryValue fields.

  • componentsJ — componentsJ must be one of the integers 1 to 6, or 0 for a scalar or extra point.

  • node — a grid, scalar or extra point ID must be a positive integer.

  • components — components must be one of the integers 1 to 6, or 0 for a scalar point.

  • realValue — a term of the matrix must be a finite number.

  • imaginaryValue — a column of a real matrix has no imaginary parts (imaginaryValue is blank).

Example record

ModuleDirectMatrix;KSPR;2;205;3;;;;2;205;3;100.

Model containing this record

Reading the example gives entryName = KSPR, columnModuleId = 2, matrixShapeOrNodeJ = 205, inputTypeOrComponentsJ = 3.

ModuleEntryExclusion

The Bulk Data entries of a primary module that a secondary (copied) module ignores.

Record format and fields

ModuleEntryExclusion;<entries>

This part of the record has no fixed fields.

Repeated group entries. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

entry

text

—

Member of the ordered input list, interpreted by the selected entry type.

Accepted words: Constant, Element, Node, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • entry1 — the card names at least one Bulk Data entry.

  • entry — Node cannot be excluded (a fatal error).

Example record

ModuleEntryExclusion;PointForceLoad

Model containing this record

ModuleExcludedNodes

The grid points of a module that are left out when the module is attached to another one (or to all the others): the counterpart of the ModuleBoundaryNodes, which limits the search to a list.

Record format and fields

ModuleExcludedNodes;moduleIdA;otherModule;<nodes>

Position

Field

Type

Default

Meaning and conventions

1

moduleIdA

integer

0

Identifier of the module on side A.

2

otherModule

any

—

Identifier of the module on the other side of the operation.

Repeated group nodes. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

nodeA

any

—

Grid point identifier at connectivity position A.

Accepted words: All, Through.

Example record

ModuleExcludedNodes;1;0;104

Model containing this record

Reading the example gives moduleIdA = 1, otherModule = 0.

ModuleFastener

A fastener with a material orientation that connects two surface patches that lie in two modules (the multi-module counterpart of the Fastener).

Record format and fields

ModuleFastener;id;propId;kind;patchIdA;patchIdB;spotNode;nodeA;nodeB;xStation;yStation;zStation;moduleIdA;moduleIdB

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

propId

integer

same as id

Identifier of the property from which the element obtains its section or constitutive data.

3

kind

text

—

Selects the kind for ModuleFastener.

4

patchIdA

integer

Required

Identifier of the patch on side A.

5

patchIdB

integer

Required

Identifier of the patch on side B.

6

spotNode

integer

0

Grid point locating the connection spot.

7

nodeA

integer

0

Grid point identifier at connectivity position A.

8

nodeB

integer

0

Grid point identifier at connectivity position B.

9

xStation

real

—

X coordinate of the evaluation station.

10

yStation

real

—

Y coordinate of the evaluation station.

11

zStation

real

—

Z coordinate of the evaluation station.

12

moduleIdA

integer

0

Identifier of the module on side A.

13

moduleIdB

integer

0

Identifier of the module on side B.

Accepted words: Constant, Element, Elements, Property, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be an integer from 1 to 99999999.

Example record

ModuleFastener;306;31;Property;11;12;;;;15.;5.;1.5;1;2

Model containing this record

Reading the example gives id = 306, propId = 31, kind = Property, patchIdA = 11.

ModuleFluidSet

Identifies the fluid points or elements in a module that participate in a FluidStructureInterface.

Record format and fields

ModuleFluidSet;moduleId;<ids>

Position

Field

Type

Default

Meaning and conventions

1

moduleId

integer

0

Identifier selecting the module record or set.

Repeated group ids. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

id

any

—

Identifier carried by the record.

Accepted words: All, Through.

Example record

ModuleFluidSet;1;1011;Through;1019

Model containing this record

Reading the example gives moduleId = 1.

ModuleLabel

The label a module carries in the headings of the results output.

Record format and fields

ModuleLabel;id;entryLabel

Position

Field

Type

Default

Meaning and conventions

1

id

integer

0

Identifier in the namespace of this card type.

2

entryLabel

text

—

User label associated with the entry. Written as one text field.

Accepted words: All, Through.

Example record

ModuleLabel;1;Primary panel

Model containing this record

Reading the example gives id = 1, entryLabel = Primary panel.

ModuleLocation

The position of a module in the main model, given by three points of the module and the three points of module 0 that they must be moved onto.

Record format and fields

ModuleLocation;id;pointA1;pointA2;pointA3;pointB1;pointB2;pointB3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

pointA1

integer

Required

The three points in the module (plain IDs).

3

pointA2

integer

Required

Grid or geometric point 2 in the original interface frame of the part to be positioned.

4

pointA3

integer

Required

Grid or geometric point 3 in the original interface frame of the part to be positioned.

5

pointB1

integer

Required

The three points of module 0 that they are moved onto.

6

pointB2

integer

Required

Matching point 2 in the receiving frame after positioning the part.

7

pointB3

integer

Required

Matching point 3 in the receiving frame after positioning the part.

Accepted words: Constant, Element, Table.

Example record

ModuleLocation;2;201;203;207;951;952;953

Model containing this record

Reading the example gives id = 2, pointA1 = 201, pointA2 = 203, pointA3 = 207.

ModuleMirror1

A mirror image of a module in a plane given by three points of the main Bulk Data.

Record format and fields

ModuleMirror1;id;point1;point2;point3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

point1

integer

Required

Point at position 1 in the ordered ModuleMirror1 data.

3

point2

integer

Required

Point at position 2 in the ordered ModuleMirror1 data.

4

point3

integer

Required

Point at position 3 in the ordered ModuleMirror1 data.

Accepted words: Constant, Element, Table.

Example record

ModuleMirror1;61;931;932;933

Model containing this record

Reading the example gives id = 61, point1 = 931, point2 = 932, point3 = 933.

ModuleMirror2

A mirror image of a module in a plane given by two axes of a coordinate system.

Record format and fields

ModuleMirror2;id;frameId;referenceNode;axes

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

frameId

integer

0

Coordinate system in which this entry is expressed.

3

referenceNode

integer

0

Identifier of the grid point serving as the reference for this definition.

4

axes

text

—

Coordinate axes used to express or select the specified quantities.

Accepted words: Constant, Element, PlaneXy, PlaneXz, PlaneYx, PlaneYz, PlaneZx, PlaneZy, Table.

Example record

ModuleMirror2;71;;920;PlaneYz

Model containing this record

Reading the example gives id = 71, referenceNode = 920, axes = PlaneYz.

ModuleMirrorPlane

A mirror image of a module (a primary or a secondary, copied one) in a plane given by three points of the main Bulk Data.

Record format and fields

ModuleMirrorPlane;id;point1;point2;point3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

point1

integer

Required

Point at position 1 in the ordered ModuleMirrorPlane data.

3

point2

integer

Required

Point at position 2 in the ordered ModuleMirrorPlane data.

4

point3

integer

Required

Point at position 3 in the ordered ModuleMirrorPlane data.

Accepted words: Constant, Element, Table.

Example record

ModuleMirrorPlane;3;911;912;913

Model containing this record

Reading the example gives id = 3, point1 = 911, point2 = 912, point3 = 913.

ModuleMoveSequence

The sequence of moves that repositions a module, given as the numbers of ModuleTranslation, ModuleRotation1, ModuleRotation2, ModuleMirror1 and ModuleMirror2 cards, applied in the order of the list.

Record format and fields

ModuleMoveSequence;id;<moveIds>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group moveIds. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

moveId

integer

—

Identifier selecting the move record or set.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • moveId1 — the card needs at least one move (moveId1).

Example record

ModuleMoveSequence;6;61;62

Model containing this record

Reading the example gives id = 6.

ModuleMultiPointConstr

Defines a linear multipoint constraint using degrees of freedom in different modules.

Record format and fields

ModuleMultiPointConstr;id;moduleId1;node1;components1;coefficient1;<terms>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

moduleId1

integer

0

Identifier selecting the module record or set.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

components1

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1.

5

coefficient1

real

—

Coefficient 1 in the ModuleMultiPointConstr relation.

Repeated group terms. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

moduleId

integer

—

Identifier selecting the module record or set.

2

node

integer

—

Grid point to which this entry applies.

3

components

integer

—

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations.

4

coefficient

real

—

Coefficient value in the ModuleMultiPointConstr relation for terms.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • node — the card needs at least one term.

  • components — components must be one of the integers 1 to 6, or 0 for a scalar point.

  • coefficient1 — the coefficient of the dependent term (coefficient1) must not be zero.

Example record

ModuleMultiPointConstr;10;2;208;3;1.;1;108;3;-1.

Model containing this record

Reading the example gives id = 10, moduleId1 = 2, node1 = 208, components1 = 3.

ModuleRigidBodyStar

A rigid body whose six independent degrees of freedom are those of one grid point and whose dependent degrees of freedom are components of any number of other grid points, all of which may lie in different modules (the multi-module counterpart of the RigidBodyStar, whose rules apply).

Record format and fields

ModuleRigidBodyStar;id;independentModuleId;independentNode;dependentComponents;<dependents>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

independentModuleId

integer

0

Identifier selecting the independent module record or set.

3

independentNode

integer

Required

Point supplying an independent motion in the constraint.

4

dependentComponents

integer

Required

Component digits whose motion is determined by the constraint.

Repeated group dependents. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

dependentModule

number

—

Module containing the dependent side of the connection.

2

dependentNode

number

—

Point whose selected motions are expressed through other degrees of freedom.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be an integer from 1 to 99999999.

  • dependentComponents — dependentComponents must be a list of the digits 1 to 6, each at most once.

  • dependentNode — the card needs at least one dependent grid point.

Example record

ModuleRigidBodyStar;302;1;112;123456;2;212

Model containing this record

Reading the example gives id = 302, independentModuleId = 1, independentNode = 112, dependentComponents = 123456.

ModuleRigidInterpolation

The motion of a reference grid point is the weighted average of the motion of other grid points, all of which may lie in different modules (the multi-module counterpart of the RigidInterpolation, whose rules apply).

Record format and fields

ModuleRigidInterpolation;id;referenceModuleId;referenceNode;referenceComponents;<weightedGroups>;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

referenceModuleId

integer

0

Identifier selecting the reference module record or set.

3

referenceNode

integer

Required

Identifier of the grid point serving as the reference for this definition.

4

referenceComponents

integer

Required

Degrees of freedom used as the reference motion.

Repeated group weightedGroups. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

weightedGroupItem

number

—

Entity or quantity included in the group with the associated weight.

Keyed sections in parts

Begin each section with its key, then write its fixed fields and any counted list.

Section DependentDofs

Repeated group dependents. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

dependentModuleId

integer

—

Identifier selecting the dependent module record or set.

2

dependentNode

integer

—

Point whose selected motions are expressed through other degrees of freedom.

3

dependentComponents

integer

—

Component digits whose motion is determined by the constraint.

Section ThermalExpansion

Position

Field

Type

Default

Meaning and conventions

1

alphaCoefficient

real

0.0

Coefficient in the relation for alpha.

2

referenceTemperature

real

0.0

Temperature defining the reference state for these data, in the model’s temperature scale.

Accepted words: Constant, DependentDofs, Element, Table, ThermalExpansion.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be an integer from 1 to 99999999.

  • referenceComponents — referenceComponents must be a list of the digits 1 to 6, each at most once.

  • weight1 — the card needs at least one weighted group.

  • components — components must be a list of the digits 1 to 6, each at most once.

  • node — a weighted group needs at least one grid point.

  • dependentComponents — dependentComponents must be a list of the digits 1 to 6, each at most once.

Example record

ModuleRigidInterpolation;304;;50;123;6;1.;123;1;106;2;206

Model containing this record

Reading the example gives id = 304, referenceNode = 50, referenceComponents = 123.

ModuleRigidJoint

A rigid joint that connects two coinciding grid points that lie in two different modules (the multi-module counterpart of the RigidJoint, whose rules apply).

Record format and fields

ModuleRigidJoint;id;moduleIdA;nodeA;moduleIdB;nodeB;componentsB

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

moduleIdA

integer

0

Identifier of the module on side A.

3

nodeA

integer

Required

Grid point identifier at connectivity position A.

4

moduleIdB

integer

0

Identifier of the module on side B.

5

nodeB

integer

Required

Grid point identifier at connectivity position B.

6

componentsB

integer

—

Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • componentsB — componentsB must be a list of the digits 1 to 6, each at most once.

Example record

ModuleRigidJoint;301;;60;2;201;123456

Model containing this record

Reading the example gives id = 301, nodeA = 60, moduleIdB = 2, nodeB = 201.

ModuleRigidRod

A pin-ended element that is rigid in translation and connects two grid points that lie in two modules (the multi-module counterpart of the RigidRod, whose rules apply).

Record format and fields

ModuleRigidRod;id;moduleIdA;nodeA;moduleIdB;nodeB;componentsAtA;componentsAtB;alphaCoefficient;referenceTemperature

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

moduleIdA

integer

0

Identifier of the module on side A.

3

nodeA

integer

Required

Grid point identifier at connectivity position A.

4

moduleIdB

integer

0

Identifier of the module on side B.

5

nodeB

integer

Required

Grid point identifier at connectivity position B.

6

componentsAtA

integer

0

Selected degrees of freedom at point A.

7

componentsAtB

integer

0

Selected degrees of freedom at point B.

8

alphaCoefficient

real

0.0

Coefficient in the relation for alpha.

9

referenceTemperature

real

0.0

Temperature defining the reference state for these data, in the model’s temperature scale.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be an integer from 1 to 99999999.

  • componentsAtA — componentsAtA must be 1, 2, 3 or blank.

  • componentsAtB — componentsAtB must be 1, 2, 3 or blank.

Example record

ModuleRigidRod;303;1;104;2;204;;3

Model containing this record

Reading the example gives id = 303, moduleIdA = 1, nodeA = 104, moduleIdB = 2.

ModuleRotation1

A rotation of a module about an axis given by two points of the main Bulk Data, optionally turning about a reference point.

Record format and fields

ModuleRotation1;id;referenceNode;startNode;endNode;magnitude

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

referenceNode

integer

0

Identifier of the grid point serving as the reference for this definition.

3

startNode

integer

Required

Grid point at the beginning of the path or directed edge.

4

endNode

integer

Required

Grid point at the end of the path or directed edge.

5

magnitude

real

Required

Scale of the quantity applied by this record. Its units follow the load or displacement being specified.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • magnitude — magnitude must not be zero.

Example record

ModuleRotation1;41;;920;921;90.

Model containing this record

Reading the example gives id = 41, startNode = 920, endNode = 921, magnitude = 90..

ModuleRotation2

A rotation of a module about an axis of a coordinate system, optionally turning about a reference point.

Record format and fields

ModuleRotation2;id;frameId;referenceNode;axis;magnitude

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

frameId

integer

0

Coordinate system in which this entry is expressed.

3

referenceNode

integer

0

Identifier of the grid point serving as the reference for this definition.

4

axis

text

—

Coordinate axis about which the definition acts.

5

magnitude

real

Required

Scale of the quantity applied by this record. Its units follow the load or displacement being specified.

Accepted words: Constant, Element, MinusXAxis, MinusYAxis, MinusZAxis, Table, XAxis, YAxis, ZAxis.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • magnitude — magnitude must not be zero.

Example record

ModuleRotation2;51;;920;ZAxis;-90.

Model containing this record

Reading the example gives id = 51, referenceNode = 920, axis = ZAxis, magnitude = -90..

ModuleSeam

A seam that connects two surface patches (shell elements) that lie in two modules (the multi-module counterpart of the Seam, whose rules apply).

Record format and fields

ModuleSeam;id;propId;seamLineName;patchKind;startPatchIdA;startPatchIdB;endPatchIdA;endPatchIdB;startNode;xStation;endNode;yStation;zStation;xEnd;yEnd;zEnd;moduleIdA;moduleIdB

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

seamLineName

text

—

Text naming the seam line.

4

patchKind

text

—

Selects the patch kind for ModuleSeam.

5

startPatchIdA

integer

Required

Identifier at the start of the patch range on side A.

6

startPatchIdB

integer

0

Identifier at the start of the patch range on side B.

7

endPatchIdA

integer

0

Identifier at the end of the patch range on side A.

8

endPatchIdB

integer

0

Identifier at the end of the patch range on side B.

9

startNode

integer

—

Grid point at the beginning of the path or directed edge. Alternative to xStation.

10

xStation

real

—

X coordinate of the evaluation station. Alternative to startNode.

11

endNode

integer

—

Grid point at the end of the path or directed edge. Alternative to yStation.

12

yStation

real

—

Y coordinate of the evaluation station. Alternative to endNode.

13

zStation

real

—

Z coordinate of the evaluation station.

14

xEnd

real

—

x coordinate of the endpoint.

15

yEnd

real

—

y coordinate of the endpoint.

16

zEnd

real

—

z coordinate of the endpoint.

17

moduleIdA

integer

0

Identifier of the module on side A.

18

moduleIdB

integer

0

Identifier of the module on side B.

Accepted words: Constant, Element, Elements, ShellProp, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be an integer from 1 to 99999999.

  • startNode — startNode is required and must be a positive integer.

  • endNode — endNode is required and must be a positive integer.

Example record

ModuleSeam;308;33;;ShellProp;11;12;;;;32.;;15.;1.5;38.;15.;1.5;1;2

Model containing this record

Reading the example gives id = 308, propId = 33, patchKind = ShellProp, startPatchIdA = 11.

ModuleStructureSet

Identifies the structural points or elements in a module that participate in a FluidStructureInterface.

Record format and fields

ModuleStructureSet;moduleId;<ids>

Position

Field

Type

Default

Meaning and conventions

1

moduleId

integer

0

Identifier selecting the module record or set.

Repeated group ids. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

id

any

—

Identifier carried by the record.

Accepted words: All, Through.

Example record

ModuleStructureSet;0;1;Through;9

Model containing this record

Reading the example gives moduleId = 0.

ModuleTranslation

A translation of a module, given as a vector between two points of the main Bulk Data.

Record format and fields

ModuleTranslation;id;startNode;endNode;magnitude

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

startNode

integer

Required

Grid point at the beginning of the path or directed edge.

3

endNode

integer

Required

Grid point at the end of the path or directed edge.

4

magnitude

real

0.0

Scale of the quantity applied by this record. Its units follow the load or displacement being specified.

Accepted words: Constant, Element, Table.

Example record

ModuleTranslation;62;941;942

Model containing this record

Reading the example gives id = 62, startNode = 941, endNode = 942.

ModuleWeld

A weld or fastener that connects two surface patches, a point and a patch, or two points, between two modules (the multi-module counterpart of the Weld, whose rules apply).

Record format and fields

ModuleWeld;id;propId;spotNode;kind;nodeA;nodeB;patchTypes;matFrameId;patchIdA;patchIdB;spotModuleId;moduleIdA;moduleIdB;nodeA1;xStation;nodeA2;yStation;nodeA3;zStation;nodeA4;nodeA5;nodeA6;nodeA7;nodeA8;nodeB1;nodeB2;nodeB3;nodeB4;nodeB5;nodeB6;nodeB7;nodeB8

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

3

spotNode

integer

0

Grid point locating the connection spot.

4

kind

text

—

Selects the kind for ModuleWeld.

5

nodeA

integer

0

Grid point identifier at connectivity position A.

6

nodeB

integer

0

Grid point identifier at connectivity position B.

7

patchTypes

text

—

Categories of patches included in the selection.

8

matFrameId

integer

—

Coordinate system defining the material directions.

9

patchIdA

integer

—

Identifier of the patch on side A.

10

patchIdB

integer

—

Identifier of the patch on side B.

11

spotModuleId

integer

0

Identifier selecting the spot module record or set.

12

moduleIdA

integer

0

Identifier of the module on side A.

13

moduleIdB

integer

0

Identifier of the module on side B.

14

nodeA1

integer

—

Identifier of the grid point on side A at position 1. Alternative to xStation.

15

xStation

real

—

X coordinate of the evaluation station. Alternative to nodeA1.

16

nodeA2

integer

—

Identifier of the grid point on side A at position 2. Alternative to yStation.

17

yStation

real

—

Y coordinate of the evaluation station. Alternative to nodeA2.

18

nodeA3

integer

—

Identifier of the grid point on side A at position 3. Alternative to zStation.

19

zStation

real

—

Z coordinate of the evaluation station. Alternative to nodeA3.

20

nodeA4

integer

—

Identifier of the grid point on side A at position 4.

21

nodeA5

integer

—

Identifier of the grid point on side A at position 5.

22

nodeA6

integer

—

Identifier of the grid point on side A at position 6.

23

nodeA7

integer

—

Identifier of the grid point on side A at position 7.

24

nodeA8

integer

—

Identifier of the grid point on side A at position 8.

25

nodeB1

integer

—

Identifier of the grid point on side B at position 1.

26

nodeB2

integer

—

Identifier of the grid point on side B at position 2.

27

nodeB3

integer

—

Identifier of the grid point on side B at position 3.

28

nodeB4

integer

—

Identifier of the grid point on side B at position 4.

29

nodeB5

integer

—

Identifier of the grid point on side B at position 5.

30

nodeB6

integer

—

Identifier of the grid point on side B at position 6.

31

nodeB7

integer

—

Identifier of the grid point on side B at position 7.

32

nodeB8

integer

—

Identifier of the grid point on side B at position 8.

Accepted words: AlignedNodes, Constant, ElemIdPatch, ElemPatch, Element, NodeIdPatch, PartPatch, QuadPatch, QuadQuadPatch, QuadTriaPatch, Table, TriaPatch, TriaQuadPatch, TriaTriaPatch.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the element ID must be an integer from 1 to 99999999.

  • matFrameId — matFrameId must be -1 (blank) or a coordinate system ID.

  • nodeA1 — the grid point IDs must not be negative.

  • patchIdB — the two patches must be different.

Example record

ModuleWeld;307;32;;PartPatch;;;;;11;12;;1;2;;25.;;15.;;1.5

Model containing this record

Reading the example gives id = 307, propId = 32, kind = PartPatch, patchIdA = 11.

Node

A grid point with a position, an input coordinate system and a coordinate system for its displacement components.

Record format and fields

Node;id;positionFrameId;position1;position2;position3;displacementFrameId;permanentConstraints;superelementId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Unique grid point identifier used by connectivity, loads and constraints.

2

positionFrameId

integer

0

Coordinate system used to interpret the position coordinates.

3

position1

real

0.0

First coordinate in the position frame. It is x in a rectangular frame and radius in a cylindrical or spherical frame.

4

position2

real

0.0

Second coordinate in the position frame. It is y in a rectangular frame and an angle in cylindrical or spherical coordinates.

5

position3

real

0.0

Third coordinate in the position frame. It is z in rectangular and cylindrical coordinates and an angle in spherical coordinates.

6

displacementFrameId

integer

0

Coordinate system in which the displacement components are expressed.

7

permanentConstraints

integer

0

Component digits fixed at this node in its displacement frame.

8

superelementId

integer

0

Identifier of the superelement associated with the entry.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the ID must be a positive integer.

  • positionFrameId — positionFrameId must be 0 or a coordinate system ID.

  • displacementFrameId — displacementFrameId must be -1, 0 or a coordinate system ID.

  • permanentConstraints — permanentConstraints must be digits 1 to 6 with no repeat.

Example record

Node;1;1;50.;0.;0.;1

Model containing this record

Reading the example gives id = 1, positionFrameId = 1, position1 = 50., position2 = 0..

Referenced records in this example

NodeDefaults

Supplies default position and displacement frames, permanent constraints and superelement membership for Node records with blank fields.

Record format and fields

NodeDefaults;positionFrameId;displacementFrameId;permanentConstraints;superelementId

Position

Field

Type

Default

Meaning and conventions

1

positionFrameId

integer

0

Coordinate system used to interpret the position coordinates.

2

displacementFrameId

integer

0

Coordinate system in which the displacement components are expressed.

3

permanentConstraints

integer

0

Permanent single-point constraints, as digits 1..6 (0 = none).

4

superelementId

integer

0

Identifier of the superelement associated with the entry.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • positionFrameId — positionFrameId must be 0 or a coordinate system ID.

  • displacementFrameId — displacementFrameId must be -1, 0 or a coordinate system ID.

  • permanentConstraints — permanentConstraints must be digits 1 to 6 with no repeat.

  • superelementId — superelementId must be 0 or a superelement ID.

Example record

NodeDefaults;10;10

Model containing this record

Reading the example gives positionFrameId = 10, displacementFrameId = 10.

NodeSequence

The sequence in which grid and scalar points are ordered (manual resequencing).

Record format and fields

NodeSequence;<points>

This part of the record has no fixed fields.

Repeated group points. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

node

integer

—

Grid point to which this entry applies.

2

sequenceId

number

—

Identifier selecting the sequence record or set.

Accepted words: Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • node1 — the card needs at least one point.

  • node1 — the card has at most four points.

  • node1 — a grid or scalar point ID must be a positive integer.

  • sequenceId1 — a sequence number must be greater than zero.

Example record

NodeSequence;461;406.5;441;403.5

Model containing this record

ScalarPoint

Defines scalar grid-free degrees of freedom by their point identifiers.

Record format and fields

ScalarPoint;<ids>

This part of the record has no fixed fields.

Repeated group ids. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

id

any

—

Identifier in the node namespace.

Accepted words: Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the scalar point ID must be a positive integer.

Example record

ScalarPoint;1001;Through;1008

Model containing this record

ShellNormal

The surface normal vector at a grid point, for the ShellQuad4, ShellQuad4Drilling, ShellTria3 and ShellTria3Drilling shell elements.

Record format and fields

ShellNormal;nodeId;frameId;directionX;directionY;directionZ

Position

Field

Type

Default

Meaning and conventions

1

nodeId

integer

Required

Identifier of the grid point addressed by this record.

2

frameId

integer

0

Coordinate system in which this entry is expressed.

3

directionX

real

0.0

X component of the specified direction vector in its reference frame.

4

directionY

real

0.0

Y component of the specified direction vector in its reference frame.

5

directionZ

real

0.0

Z component of the specified direction vector in its reference frame.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • frameId — frameId must be 0 or a coordinate system ID.

Example record

ShellNormal;1111;10;1.;0.;0.

Model containing this record

Reading the example gives nodeId = 1111, frameId = 10, directionX = 1., directionY = 0..

Referenced records in this example

  • Node via nodeId = 1111.

SurfaceEdge

Declares how the surface continues across an edge between two nodes. A declaration may apply to one incident element when its state permits this.

Record format and fields

SurfaceEdge;id;node1Id;node2Id;state;elementId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

node1Id

integer

Required

Grid point at one end of the declared edge.

3

node2Id

integer

Required

Grid point at the other end of the declared edge.

4

state

text

—

Surface continuation at this edge. Smooth continues the tangent plane, Sharp marks a fold and Raw retains the mesh edge.

5

elementId

integer

0

Optional incident element restricting the declaration to its side of the edge.

Accepted words: Raw, Sharp, Smooth.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • node1Id — the two grid points of the edge must be different.

  • state — state is required: Smooth, Sharp or Raw.

  • state — state must be Smooth, Sharp or Raw.

  • elementId — elementId must be blank when state is Raw.

Example record

SurfaceEdge;1;301;302;Smooth

Reading the example gives id = 1, node1Id = 301, node2Id = 302, state = Smooth.

SurfaceFacet

Declares an existing shell element to be a flat facet bounded by straight folds. The element ID also identifies its declaration.

Record format and fields

SurfaceFacet;elementId

Position

Field

Type

Default

Meaning and conventions

1

elementId

integer

Required

Identifier of the existing shell element whose face is declared planar.

Example record

SurfaceFacet;501

Reading the example gives elementId = 501.

SurfaceLine

Declares the path or end of a surface line through an ordered sequence of grid points.

Record format and fields

SurfaceLine;id;node1Id;throughNodeId;node2Id

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

node1Id

integer

Required

First grid point defining the line direction.

3

throughNodeId

integer

Required

Grid point at which the line continues or terminates.

4

node2Id

integer

0

Next grid point on the line. Omit it to declare a line end.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • node1Id — node1Id and throughNodeId must be different.

  • node2Id — node2Id must be different from node1Id and throughNodeId.

Example record

SurfaceLine;1;501;502;503