Points and geometry¶
All card families and alphabetical index
Read field positions from left to right within each table. A dash means the layout supplies no fixed default. Use a consistent system of units for dimensional quantities.
AcousticSlotControl¶
Defines the harmonic index and default fluid properties for an acoustic cavity represented by slots.
Record format and fields
AcousticSlotControl;defaultDensity;defaultBulkModulus;harmonic;defaultSlotWidth;defaultSlotCount
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Density used when the corresponding input leaves its density unspecified. |
2 |
|
|
— |
Default bulk modulus (force per area). |
3 |
|
|
— |
Index identifying the spatial or temporal harmonic. |
4 |
|
|
— |
Default slot width (length). |
5 |
|
|
— |
Number of default slot entries. |
Accepted words: Constant, Element, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
harmonic—harmonicmust not be negative.defaultSlotCount—defaultSlotCountmust not be negative.
Example record
AcousticSlotControl;1.2E-12;0.142;0;5.;6
Reading the example gives defaultDensity = 1.2E-12, defaultBulkModulus = 0.142, harmonic = 0, defaultSlotWidth = 5..
AcousticSlotFluidPoint¶
An axisymmetric fluid point of the acoustic cavity (slot) analysis, a scalar degree of freedom (the pressure) with a two-dimensional location.
Record format and fields
AcousticSlotFluidPoint;id;radius;zCoord
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the node namespace. |
2 |
|
|
Required |
Radial dimension measured from the centre or axis (length). |
3 |
|
|
Required |
Z coordinate of the location in the specified frame. |
Accepted words: Constant, Element, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the ID must be an integer from 1 to 999999.
Example record
AcousticSlotFluidPoint;1;25.;0.
Reading the example gives id = 1, radius = 25., zCoord = 0..
AcousticSlotSurfacePoint¶
A slot surface point of the acoustic cavity (slot) analysis, a scalar degree of freedom (the pressure) with a two-dimensional location and a slot width.
Record format and fields
AcousticSlotSurfacePoint;id;radius;zCoord;slotWidth;fluidPointId
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the node namespace. |
2 |
|
|
Required |
Radial dimension measured from the centre or axis (length). |
3 |
|
|
Required |
Z coordinate of the location in the specified frame. |
4 |
|
|
— |
Slot width (length). |
5 |
|
|
0 |
Identifier addressing node data. |
Accepted words: Constant, Element, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
radius—radiusmust not be zero.
Example record
AcousticSlotSurfacePoint;21;50.;0.;;11
Reading the example gives id = 21, radius = 50., zCoord = 0., fluidPointId = 11.
Referenced records in this example
AcousticSlotFluidPoint via
fluidPointId = 11.
AdaptiveRefineControl¶
The control of the local adaptive mesh refinement for one criterion.
Record format and fields
AdaptiveRefineControl;id;repeatCount;criterionId;regionMethod;regionId;snapMethod;maximumLevel
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
— |
Number of repetitions of the defined event or block. |
3 |
|
|
Required |
Identifier selecting the criterion record or set. |
4 |
|
|
— |
Selects the region method for AdaptiveRefineControl. |
5 |
|
|
0 |
Identifier of the region on which the definition acts. |
6 |
|
|
— |
Selects the snap method for AdaptiveRefineControl. |
7 |
|
|
same as repeatCount |
Deepest allowed level of the specified hierarchy or refinement. |
Accepted words: All, Constant, Element, Property, Superelement, Table, Through.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
repeatCount—repeatCountmust not be negative.snapMethod—snapMethodmust be 0 or 1.
Example record
AdaptiveRefineControl;1;2;1;All;;0;2
Reading the example gives id = 1, repeatCount = 2, criterionId = 1, regionMethod = All.
AdaptiveRefineCriterion¶
A criterion that picks the elements to refine in the adaptive mesh refinement.
Record format and fields
AdaptiveRefineCriterion;id;kind;parameter1;parameter2;parameter3;parameter4;parameter5;parameter6
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
— |
Selects the kind for AdaptiveRefineCriterion. |
3 |
|
|
— |
Parameter 1 of the selected refinement criterion; its meaning follows the criterion. |
4 |
|
|
— |
Parameter 2 of the selected refinement criterion; its meaning follows the criterion. |
5 |
|
|
— |
Parameter 3 of the selected refinement criterion; its meaning follows the criterion. |
6 |
|
|
— |
Parameter 4 of the selected refinement criterion; its meaning follows the criterion. |
7 |
|
|
— |
Parameter 5 of the selected refinement criterion; its meaning follows the criterion. |
8 |
|
|
— |
Parameter 6 of the selected refinement criterion; its meaning follows the criterion. |
Accepted words: Constant, Element, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
kind—kindmust be 1, 2, 3 or 4.
Example record
AdaptiveRefineCriterion;2;2;0.;0.;0.;15.
Reading the example gives id = 2, kind = 2, parameter1 = 0., parameter2 = 0..
AssociativeNode¶
Associates a grid point with the assembly step that combines model parts.
Record format and fields
AssociativeNode;id;origNodeId;partitionName
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the node namespace. |
2 |
|
|
Required |
Identifier selecting the orig node record or set. |
3 |
|
|
— |
Text naming the partition. Written as one text field. |
Accepted words: Constant, Element, Table.
Example record
AssociativeNode;101;1000;LEFT_WING_TANK
Reading the example gives id = 101, origNodeId = 1000, partitionName = LEFT_WING_TANK.
AxisymConeControl¶
Identifies the model as an axisymmetric conical shell system using rings, shell elements and ring loads.
Record format and fields
AxisymConeControl;highestHarmonic
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Largest harmonic index included in the representation. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
highestHarmonic—highestHarmonicmust be an integer from 0 to 997.
Example record
AxisymConeControl;2
Reading the example gives highestHarmonic = 2.
AxisymConePoint¶
Defines a point on a conical shell ring for concentrated loads and displacement recovery.
Record format and fields
AxisymConePoint;id;ringId;phiAngle
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the node namespace. |
2 |
|
|
Required |
Identifier addressing node data. |
3 |
|
|
Required |
Angular coordinate or orientation denoted by phi in the local geometry. |
Accepted words: Constant, Element, Table.
Example record
AxisymConePoint;51;5;0.
Reading the example gives id = 51, ringId = 5, phiAngle = 0..
Referenced records in this example
AxisymConeRing via
ringId = 5.
AxisymConeRing¶
A ring of a conical shell model (an axisymmetric structure described by harmonics).
Record format and fields
AxisymConeRing;id;radius;zCoord;permanentConstraints
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the node namespace. |
2 |
|
|
Required |
Radial dimension measured from the centre or axis (length). |
3 |
|
|
Required |
Z coordinate of the location in the specified frame. |
4 |
|
|
0 |
0 = no permanent constraint. |
Accepted words: Constant, Element, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
permanentConstraints—permanentConstraintsmust be digits 1 to 6 with no repeat.
Example record
AxisymConeRing;1;100.;0.;123456
Reading the example gives id = 1, radius = 100., zCoord = 0., permanentConstraints = 123456.
AxisymFluidControl¶
The basic parameters and the existence of an axisymmetric fluid analysis, with the harmonics of the solution.
Record format and fields
AxisymFluidControl;frameId;gravity;defaultDensity;defaultBulkModulus;nonsymmetric;noHarmonicsFlag;<harmonics>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Coordinate system in which this entry is expressed. |
2 |
|
|
Required |
Acceleration of gravity used by the definition, in length per time squared. |
3 |
|
|
— |
Density used when the corresponding input leaves its density unspecified. |
4 |
|
|
— |
Default bulk modulus (force per area). |
5 |
|
|
— |
Specifies whether the two sides or matrix halves are treated separately. |
6 |
|
|
— |
Selects the no harmonics flag for AxisymFluidControl. |
Repeated group harmonics. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Index identifying the spatial or temporal harmonic. |
Accepted words: Constant, Element, No, None, Step, Table, Through, Yes.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
harmonic— a harmonic must be an integer from 0 to 99.lastHarmonic— the end of a range must be above its start and at most 99.harmonicStep—harmonicStepmust be a positive integer.harmonic— the harmonics must be in increasing order.
Example record
AxisymFluidControl;1;9810.;1.E-9;2200.;No;;0;2
Reading the example gives frameId = 1, gravity = 9810., defaultDensity = 1.E-9, defaultBulkModulus = 2200..
AxisymFluidFreePoint¶
A point on the free surface of an axisymmetric fluid at which the surface displacements are recovered.
Record format and fields
In the source layout, the form is called pairsFromSlot3 when field 2 of the old layout is blank. Its compact field sequence is the one shown below.
Forms: pairsFromSlot2.
AxisymFluidFreePoint: pairsFromSlot2¶
Form pairsFromSlot2, for every compact record.
AxisymFluidFreePoint;fluidPointId;<points>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier addressing node data. |
Repeated group points. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier of the point to which this entry applies. |
2 |
|
|
— |
Angular coordinate or orientation denoted by phi in the local geometry. |
Note: at most three pairs.
Accepted words: Constant, Element, Table.
Example record
AxisymFluidFreePoint;5;501;0.;502;45.
AxisymFluidPressurePoint¶
A point of an axisymmetric fluid at which the pressure is recovered, and that may also measure pressure for a control device.
Record format and fields
In the source layout, the form is called pairsFromSlot3 when field 2 of the old layout is blank. Its compact field sequence is the one shown below.
Forms: pairsFromSlot2.
AxisymFluidPressurePoint: pairsFromSlot2¶
Form pairsFromSlot2, for every compact record.
AxisymFluidPressurePoint;fluidPointId;<points>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier addressing node data. |
Repeated group points. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier of the point to which this entry applies. |
2 |
|
|
— |
Angular coordinate or orientation denoted by phi in the local geometry. |
Note: at most three pairs.
Accepted words: Constant, Element, Table.
Example record
AxisymFluidPressurePoint;3;301;0.;302;45.
AxisymFluidRing¶
A circle of an axisymmetric fluid model.
Record format and fields
AxisymFluidRing;firstId;firstPosition1;firstPosition2;firstPosition3;secondId;secondPosition1;secondPosition2;secondPosition3
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier selecting the first record or set. |
2 |
|
|
— |
Coordinate 1 of the first position in the specified frame. |
3 |
|
|
0.0 |
Coordinate 2 of the first position in the specified frame. |
4 |
|
|
0.0 |
Coordinate 3 of the first position in the specified frame. |
5 |
|
|
— |
Identifier selecting the second record or set. |
6 |
|
|
— |
Coordinate 1 of the second position in the specified frame. |
7 |
|
|
0.0 |
Coordinate 2 of the second position in the specified frame. |
8 |
|
|
0.0 |
Coordinate 3 of the second position in the specified frame. |
Accepted words: Constant, Element, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id—idmust be an integer from 1 to 499999.
Example record
AxisymFluidRing;1;50.;;0.;2;100.;;0.
Reading the example gives firstId = 1, firstPosition1 = 50., firstPosition3 = 0., secondId = 2.
AxisymFluidRingNode¶
A grid point on a fluid ring (AxisymFluidRing) of an axisymmetric model.
Record format and fields
AxisymFluidRingNode;id;phiAngle;displacementFrameId;permanentConstraints;fluidPointId
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the node namespace. |
2 |
|
|
Required |
Angular coordinate or orientation denoted by phi in the local geometry. |
3 |
|
|
0 |
Coordinate system in which the displacement components are expressed. |
4 |
|
|
0 |
Permanent single-point constraints, as digits 1..6 (0 = none). |
5 |
|
|
Required |
Identifier addressing node data. |
Accepted words: AxisymFluidRing.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the ID must be a positive integer.displacementFrameId—displacementFrameIdmust be 0 or a coordinate system ID.permanentConstraints—permanentConstraintsmust be digits 1 to 6 with no repeat.
Example record
AxisymFluidRingNode;401;0.;1;246;4
Reading the example gives id = 401, phiAngle = 0., displacementFrameId = 1, permanentConstraints = 246.
Referenced records in this example
CylindricalFrame2 via
displacementFrameId = 1.
ExtraPoint¶
Introduces an additional scalar degree of freedom for a dynamic model.
Record format and fields
ExtraPoint;<ids>
This part of the record has no fixed fields.
Repeated group ids. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier in the node namespace. |
Accepted words: Through.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the extra point ID must be a positive integer.
Example record
ExtraPoint;4001;4011;4012
GeomPoint¶
A geometric point that is not a grid point (an edge point for SuperelementLocation, a profile point of a BeamArbitrarySectionProp).
Record format and fields
GeomPoint;id;positionFrameId;position1;position2;position3
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the node namespace. |
2 |
|
|
0 |
Coordinate system used to interpret the position coordinates. |
3 |
|
|
0.0 |
Coordinate 1 of the specified location in its reference frame. |
4 |
|
|
0.0 |
Coordinate 2 of the specified location in its reference frame. |
5 |
|
|
0.0 |
Coordinate 3 of the specified location in its reference frame. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the ID must be a positive integer.positionFrameId—positionFrameIdmust be 0 or a coordinate system ID.
Example record
GeomPoint;941;;0.;0.;0.
Reading the example gives id = 941, position1 = 0., position2 = 0., position3 = 0..
ModuleBolt¶
Defines a pretensioned bolt spanning modules. A control point couples pairs of grid points on opposite sides of its cut.
Record format and fields
ModuleBolt;id;controlNode;controlModuleId;topModuleId;bottomModuleId;<keyed sections>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
Required |
Identifier of the grid point through which this definition is controlled. |
3 |
|
|
0 |
Identifier selecting the control module record or set. |
4 |
|
|
0 |
Identifier selecting the top module record or set. |
5 |
|
|
0 |
Identifier selecting the bottom module record or set. |
Keyed sections in lists
Begin each section with its key, then write its fixed fields and any counted list.
Section Top
Repeated group topNodes. Give the number of entries before their values.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Grid point defining the top side of the connection. |
Section Bottom
Repeated group bottomNodes. Give the number of entries before their values.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Grid point defining the bottom side of the connection. |
Accepted words: All, Bottom, Constant, Element, Table, Through, Top.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
topList— the bolt needs grid points intopList.bottomList— the bolt needs grid points inbottomList.
Example record
ModuleBolt;309;70;0;1;2;Top;2;103;107;Bottom;2;203;207
Reading the example gives id = 309, controlNode = 70, controlModuleId = 0, topModuleId = 1.
ModuleBoundaryNodes¶
The grid points of a module that the automatic search of the boundary with another module, or with all the others, is limited to.
Record format and fields
ModuleBoundaryNodes;moduleIdA;otherModule;<nodes>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
0 |
Identifier of the module on side A. |
2 |
|
|
— |
Identifier of the module on the other side of the operation. |
Repeated group nodes. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Grid point identifier at connectivity position A. |
Accepted words: All, Through.
Example record
ModuleBoundaryNodes;1;0;101;104;107
Reading the example gives moduleIdA = 1, otherModule = 0.
ModuleBrakeSystem¶
The data of a brake system for brake squeal calculations with one wheel or several, on one axis or several, in different modules.
Record format and fields
ModuleBrakeSystem;id;squealLoadFactor;frictionVectorMethod;squealOnly;contactMethod;<disks>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
0.0 |
Multiplier for squeal load. |
3 |
|
|
0 |
Selects the friction vector method for ModuleBrakeSystem. |
4 |
|
|
— |
Restricts the option to the brake-squeal analysis when selected. |
5 |
|
|
0 |
Selects the contact method for ModuleBrakeSystem. |
Repeated group disks. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Text naming the disk. |
2 |
|
|
— |
Identifier selecting the module record or set. |
3 |
|
|
— |
Identifier selecting the body 1 record or set. |
4 |
|
|
— |
Identifier selecting the module record or set. |
5 |
|
|
— |
Identifier selecting the body 2 record or set. |
6 |
|
|
— |
Identifier selecting the motion 1 record or set. |
7 |
|
|
— |
Identifier selecting the motion 2 record or set. |
8 |
|
|
— |
Identifier selecting the brake system record or set. |
Accepted words: All, Constant, Element, No, Table, Through, Yes.
Example record
ModuleBrakeSystem;1;1.;0;No;0;DISK1;1;1;0;2;1;;1
Reading the example gives id = 1, squealLoadFactor = 1., frictionVectorMethod = 0, squealOnly = No.
ModuleBulkOptions¶
The type of a module and how the boundary between modules is searched.
Record format and fields
ModuleBulkOptions;id;kind;sourceModuleId;method;tolerance;unitNumber
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier in the namespace of this card type. |
2 |
|
|
— |
Selects the kind for ModuleBulkOptions. |
3 |
|
|
0 |
Identifier selecting the source module record or set. |
4 |
|
|
— |
Selects the method for ModuleBulkOptions. |
5 |
|
|
0.0 |
Allowable change or residual for the selected numerical check. |
6 |
|
|
0 |
Logical file unit used to identify an external resource. |
Accepted words: All, Automatic, Constant, Element, External, ExternalBinaryResults, ExternalMatrixFile, Manual, Mirror, Move, Primary, Repeat, Table, Through.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
sourceModuleId—sourceModuleIdmust be zero or a positive module number.unitNumber—unitNumbermust be zero or a positive unit number.
Example record
ModuleBulkOptions;4;Move;1;Automatic
Reading the example gives id = 4, kind = Move, sourceModuleId = 1, method = Automatic.
ModuleBushing¶
A generalized spring-and-damper element whose end points may lie in different modules; the rules of the Bushing apply to it.
Record format and fields
ModuleBushing;id;propId;nodeA;nodeB;position1;orientationNode;position2;position3;frameId;offsetFraction;offsetFrameId;offset1;offset2;offset3;moduleIdA;moduleIdB;orientationModuleId
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
same as id |
Identifier of the property from which the element obtains its section or constitutive data. |
3 |
|
|
Required |
Grid point identifier at connectivity position A. |
4 |
|
|
0 |
Grid point identifier at connectivity position B. |
5 |
|
|
— |
Coordinate 1 of the specified location in its reference frame. Alternative to |
6 |
|
|
— |
Grid point defining the orientation direction in place of explicit vector components. Alternative to |
7 |
|
|
0.0 |
Coordinate 2 of the specified location in its reference frame. |
8 |
|
|
0.0 |
Coordinate 3 of the specified location in its reference frame. |
9 |
|
|
— |
Coordinate system in which this entry is expressed. |
10 |
|
|
0.5 |
Offset expressed as a fraction of the associated reference dimension or range. |
11 |
|
|
-1 |
Identifier selecting the offset frame record or set. |
12 |
|
|
0.0 |
Shift from the reference location or value in the convention of this entry. Entry 1. |
13 |
|
|
0.0 |
Shift from the reference location or value in the convention of this entry. Entry 2. |
14 |
|
|
0.0 |
Shift from the reference location or value in the convention of this entry. Entry 3. |
15 |
|
|
0 |
Identifier of the module on side A. |
16 |
|
|
0 |
Identifier of the module on side B. |
17 |
|
|
0 |
Identifier selecting the orientation module record or set. |
Accepted words: All, Constant, Element, Table, Through.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the element ID must be a positive integer below 100 000 000.nodeB—nodeBmust be 0 (blank) or a grid point ID.orientationNode—orientationNodemust be a positive grid point ID.frameId—frameIdmust be blank or a coordinate system ID.offsetFrameId—offsetFrameIdmust be -1 or a coordinate system ID.
Example record
ModuleBushing;305;34;111;211;;;;;0;;;;;;1;2
Reading the example gives id = 305, propId = 34, nodeA = 111, nodeB = 211.
ModuleConnection¶
How the boundary points of the modules are connected at a location.
Record format and fields
ModuleConnection;id;kind;tolerance;xCoord;locationNode;yCoord;zCoord;moduleId;frameId;<points>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
— |
Selects the kind for ModuleConnection. |
3 |
|
|
0.0 |
Allowable change or residual for the selected numerical check. |
4 |
|
|
0.0 |
X coordinate of the location in the specified frame. Alternative to |
5 |
|
|
— |
Grid point defining the location of the operation. Alternative to |
6 |
|
|
0.0 |
Y coordinate of the location in the specified frame. |
7 |
|
|
0.0 |
Z coordinate of the location in the specified frame. |
8 |
|
|
0 |
Identifier selecting the module record or set. |
9 |
|
|
0 |
Coordinate system in which this entry is expressed. |
Repeated group points. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier selecting the member module record or set. |
2 |
|
|
— |
Identifier selecting the member node record or set. |
Accepted words: All, Constant, Element, Merge, ModuleRigidStar, Rigid, RigidStarReleased, Table, Through.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
frameId—frameIdmust be zero or a positive coordinate system ID.locationNode—locationNodemust be a positive grid point ID.memberNodeId—memberNodeIdmust be zero (every grid point of the module) or a point ID.
Example record
ModuleConnection;21;Rigid;0.001;0.;;40.;0.;;;2;201;4;109
Reading the example gives id = 21, kind = Rigid, tolerance = 0.001, xCoord = 0..
ModuleContactCandidates¶
The modules that are candidates for the automatic detection of contact across modules.
Record format and fields
ModuleContactCandidates;moduleSetId;<pairs>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
-1 |
Identifier selecting the module set record or set. |
Repeated group pairs. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier selecting the first module record or set. |
2 |
|
|
— |
Identifier selecting the second module record or set. |
Accepted words: Constant, Element, Table, TypedListSet3.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
moduleId— a module number must not be negative.
Example record
ModuleContactCandidates;0;1;2
Reading the example gives moduleSetId = 0.
ModuleContactDetectParams¶
The parameters that detect contact pairs between bodies that lie in different modules when the contact is generated automatically, as (name, value) pairs.
Record format and fields
ModuleContactDetectParams;<parameters>
This part of the record has no fixed fields.
Repeated group parameters. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Selects the setting to assign. Use the spelling from this card’s parameter list. |
2 |
|
|
— |
Value assigned to the named parameter. Its interpretation depends on that name. |
Accepted words: BilinearCoulomb, Both, Full, GeneralGlue, No, NodeToSurface, Off, On, PermanentGlue, SegmentToSegment, StandardGlue, TouchOnly, Yes.
Accepted parameter names: BeamContact, ContactKind, DeleteSolids, DetectionDistance, EdgeContact, FrictionCoefficient, FrictionKind, IgnoreThickness, InitialStiffness, SelfContact.
Example record
ModuleContactDetectParams;ContactKind;PermanentGlue;DetectionDistance;3.
ModuleContactPair¶
A contact pair whose touching and touched bodies lie in different modules: general contact, glued, step glued or permanently glued.
Record format and fields
ModuleContactPair;id;geometricParamsId;physicalParamsId;secondaryModule;secondaryBodyId;primaryModule;primaryBodyId;<keyed sections>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
0 |
Identifier selecting the geometric params record or set. |
3 |
|
|
0 |
Identifier selecting the physical params record or set. |
4 |
|
|
0 |
Module containing the secondary side of the connection. |
5 |
|
|
0 |
Identifier selecting the secondary body record or set. |
6 |
|
|
0 |
Module containing the primary side of the connection. |
7 |
|
|
0 |
Identifier selecting the primary body record or set. |
Keyed sections in lists
Begin each section with its key, then write its fixed fields and any counted list.
Section Secondary
Repeated group secondaryBodies. Give the number of entries before their values.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Module containing the list of secondary entities. |
2 |
|
|
— |
Identifier selecting the secondary list body record or set. |
Section Primary
Repeated group primaryBodies. Give the number of entries before their values.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Module containing the list of primary entities. |
2 |
|
|
— |
Identifier selecting the primary list body record or set. |
Accepted words: Constant, Element, Primary, Secondary, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— theidmust not be negative.
Example record
ModuleContactPair;1;7;;2;2;1;1
Reading the example gives id = 1, geometricParamsId = 7, secondaryModule = 2, secondaryBodyId = 2.
ModuleContactTable¶
Selects interactions involving bodies in different modules using their contact definitions.
Record format and fields
ModuleContactTable;id;<pairs>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
Repeated group pairs. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier of the model part owning the selected entities. |
2 |
|
|
— |
Identifier selecting the contact pair record or set. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id—idmust not be negative.
Example record
ModuleContactTable;10;;1
Reading the example gives id = 10.
ModuleDirectMatrix¶
The header of a matrix of direct input at points of several modules, or one column of it.
Record format and fields
ModuleDirectMatrix;entryName;columnModuleId;matrixShapeOrNodeJ;inputTypeOrComponentsJ;outputType;polarFlag;columnCount;<terms>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Name identifying the associated item in the list. |
2 |
|
|
0 |
Identifier selecting the column module record or set. |
3 |
|
|
— |
Selects the matrix shape for a header or the column grid point for a data record. |
4 |
|
|
— |
Input numeric representation in a matrix header or column point components in a data record. |
5 |
|
|
0 |
Selects the output type for ModuleDirectMatrix. |
6 |
|
|
0 |
Selects the polar flag for ModuleDirectMatrix. |
7 |
|
|
0 |
Number of column entries. |
Repeated group terms. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier selecting the module record or set. |
2 |
|
|
— |
Grid point to which this entry applies. |
3 |
|
|
— |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. |
4 |
|
|
— |
Real scalar value or real part of the complex quantity. |
5 |
|
|
— |
Imaginary part paired with the real component. |
Accepted words: All, Through.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
entryName—entryNamemust be a nonempty matrix name without control characters.matrixShape—matrixShapemust be 1 (square), 2 or 9 (rectangular) or 6 (symmetric).inputType—inputTypemust be 1, 2, 3 or 4.outputType—outputTypemust be 0, 1, 2, 3 or 4.polarFlag—polarFlagmust not be negative.columnCount—columnCountmust not be negative.imaginaryValue— a header card has no terms and noimaginaryValuefields.componentsJ—componentsJmust be one of the integers 1 to 6, or 0 for a scalar or extra point.node— a grid, scalar or extra point ID must be a positive integer.components—componentsmust be one of the integers 1 to 6, or 0 for a scalar point.realValue— a term of the matrix must be a finite number.imaginaryValue— a column of a real matrix has no imaginary parts (imaginaryValueis blank).
Example record
ModuleDirectMatrix;KSPR;2;205;3;;;;2;205;3;100.
Reading the example gives entryName = KSPR, columnModuleId = 2, matrixShapeOrNodeJ = 205, inputTypeOrComponentsJ = 3.
ModuleEntryExclusion¶
The Bulk Data entries of a primary module that a secondary (copied) module ignores.
Record format and fields
ModuleEntryExclusion;<entries>
This part of the record has no fixed fields.
Repeated group entries. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Member of the ordered input list, interpreted by the selected entry type. |
Accepted words: Constant, Element, Node, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
entry1— the card names at least one Bulk Data entry.entry— Node cannot be excluded (a fatal error).
Example record
ModuleEntryExclusion;PointForceLoad
ModuleExcludedNodes¶
The grid points of a module that are left out when the module is attached to another one (or to all the others): the counterpart of the ModuleBoundaryNodes, which limits the search to a list.
Record format and fields
ModuleExcludedNodes;moduleIdA;otherModule;<nodes>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
0 |
Identifier of the module on side A. |
2 |
|
|
— |
Identifier of the module on the other side of the operation. |
Repeated group nodes. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Grid point identifier at connectivity position A. |
Accepted words: All, Through.
Example record
ModuleExcludedNodes;1;0;104
Reading the example gives moduleIdA = 1, otherModule = 0.
ModuleFastener¶
A fastener with a material orientation that connects two surface patches that lie in two modules (the multi-module counterpart of the Fastener).
Record format and fields
ModuleFastener;id;propId;kind;patchIdA;patchIdB;spotNode;nodeA;nodeB;xStation;yStation;zStation;moduleIdA;moduleIdB
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
same as id |
Identifier of the property from which the element obtains its section or constitutive data. |
3 |
|
|
— |
Selects the kind for ModuleFastener. |
4 |
|
|
Required |
Identifier of the patch on side A. |
5 |
|
|
Required |
Identifier of the patch on side B. |
6 |
|
|
0 |
Grid point locating the connection spot. |
7 |
|
|
0 |
Grid point identifier at connectivity position A. |
8 |
|
|
0 |
Grid point identifier at connectivity position B. |
9 |
|
|
— |
X coordinate of the evaluation station. |
10 |
|
|
— |
Y coordinate of the evaluation station. |
11 |
|
|
— |
Z coordinate of the evaluation station. |
12 |
|
|
0 |
Identifier of the module on side A. |
13 |
|
|
0 |
Identifier of the module on side B. |
Accepted words: Constant, Element, Elements, Property, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the element ID must be an integer from 1 to 99999999.
Example record
ModuleFastener;306;31;Property;11;12;;;;15.;5.;1.5;1;2
Reading the example gives id = 306, propId = 31, kind = Property, patchIdA = 11.
ModuleFluidSet¶
Identifies the fluid points or elements in a module that participate in a FluidStructureInterface.
Record format and fields
ModuleFluidSet;moduleId;<ids>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
0 |
Identifier selecting the module record or set. |
Repeated group ids. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier carried by the record. |
Accepted words: All, Through.
Example record
ModuleFluidSet;1;1011;Through;1019
Reading the example gives moduleId = 1.
ModuleLabel¶
The label a module carries in the headings of the results output.
Record format and fields
ModuleLabel;id;entryLabel
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
0 |
Identifier in the namespace of this card type. |
2 |
|
|
— |
User label associated with the entry. Written as one text field. |
Accepted words: All, Through.
Example record
ModuleLabel;1;Primary panel
Reading the example gives id = 1, entryLabel = Primary panel.
ModuleLocation¶
The position of a module in the main model, given by three points of the module and the three points of module 0 that they must be moved onto.
Record format and fields
ModuleLocation;id;pointA1;pointA2;pointA3;pointB1;pointB2;pointB3
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
Required |
The three points in the module (plain IDs). |
3 |
|
|
Required |
Grid or geometric point 2 in the original interface frame of the part to be positioned. |
4 |
|
|
Required |
Grid or geometric point 3 in the original interface frame of the part to be positioned. |
5 |
|
|
Required |
The three points of module 0 that they are moved onto. |
6 |
|
|
Required |
Matching point 2 in the receiving frame after positioning the part. |
7 |
|
|
Required |
Matching point 3 in the receiving frame after positioning the part. |
Accepted words: Constant, Element, Table.
Example record
ModuleLocation;2;201;203;207;951;952;953
Reading the example gives id = 2, pointA1 = 201, pointA2 = 203, pointA3 = 207.
ModuleMirror1¶
A mirror image of a module in a plane given by three points of the main Bulk Data.
Record format and fields
ModuleMirror1;id;point1;point2;point3
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
Required |
Point at position 1 in the ordered ModuleMirror1 data. |
3 |
|
|
Required |
Point at position 2 in the ordered ModuleMirror1 data. |
4 |
|
|
Required |
Point at position 3 in the ordered ModuleMirror1 data. |
Accepted words: Constant, Element, Table.
Example record
ModuleMirror1;61;931;932;933
Reading the example gives id = 61, point1 = 931, point2 = 932, point3 = 933.
ModuleMirror2¶
A mirror image of a module in a plane given by two axes of a coordinate system.
Record format and fields
ModuleMirror2;id;frameId;referenceNode;axes
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
0 |
Coordinate system in which this entry is expressed. |
3 |
|
|
0 |
Identifier of the grid point serving as the reference for this definition. |
4 |
|
|
— |
Coordinate axes used to express or select the specified quantities. |
Accepted words: Constant, Element, PlaneXy, PlaneXz, PlaneYx, PlaneYz, PlaneZx, PlaneZy, Table.
Example record
ModuleMirror2;71;;920;PlaneYz
Reading the example gives id = 71, referenceNode = 920, axes = PlaneYz.
ModuleMirrorPlane¶
A mirror image of a module (a primary or a secondary, copied one) in a plane given by three points of the main Bulk Data.
Record format and fields
ModuleMirrorPlane;id;point1;point2;point3
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
Required |
Point at position 1 in the ordered ModuleMirrorPlane data. |
3 |
|
|
Required |
Point at position 2 in the ordered ModuleMirrorPlane data. |
4 |
|
|
Required |
Point at position 3 in the ordered ModuleMirrorPlane data. |
Accepted words: Constant, Element, Table.
Example record
ModuleMirrorPlane;3;911;912;913
Reading the example gives id = 3, point1 = 911, point2 = 912, point3 = 913.
ModuleMoveSequence¶
The sequence of moves that repositions a module, given as the numbers of ModuleTranslation, ModuleRotation1, ModuleRotation2, ModuleMirror1 and ModuleMirror2 cards, applied in the order of the list.
Record format and fields
ModuleMoveSequence;id;<moveIds>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
Repeated group moveIds. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier selecting the move record or set. |
Accepted words: Constant, Element, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
moveId1— the card needs at least one move (moveId1).
Example record
ModuleMoveSequence;6;61;62
Reading the example gives id = 6.
ModuleMultiPointConstr¶
Defines a linear multipoint constraint using degrees of freedom in different modules.
Record format and fields
ModuleMultiPointConstr;id;moduleId1;node1;components1;coefficient1;<terms>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Set identifier shared by entries in the same group. |
2 |
|
|
0 |
Identifier selecting the module record or set. |
3 |
|
|
— |
Grid point to which this entry applies. Entry 1. |
4 |
|
|
0 |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. Entry 1. |
5 |
|
|
— |
Coefficient 1 in the ModuleMultiPointConstr relation. |
Repeated group terms. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier selecting the module record or set. |
2 |
|
|
— |
Grid point to which this entry applies. |
3 |
|
|
— |
Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations. |
4 |
|
|
— |
Coefficient value in the ModuleMultiPointConstr relation for terms. |
Accepted words: Constant, Element, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
node— the card needs at least one term.components—componentsmust be one of the integers 1 to 6, or 0 for a scalar point.coefficient1— the coefficient of the dependent term (coefficient1) must not be zero.
Example record
ModuleMultiPointConstr;10;2;208;3;1.;1;108;3;-1.
Reading the example gives id = 10, moduleId1 = 2, node1 = 208, components1 = 3.
ModuleRigidBodyStar¶
A rigid body whose six independent degrees of freedom are those of one grid point and whose dependent degrees of freedom are components of any number of other grid points, all of which may lie in different modules (the multi-module counterpart of the RigidBodyStar, whose rules apply).
Record format and fields
ModuleRigidBodyStar;id;independentModuleId;independentNode;dependentComponents;<dependents>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
0 |
Identifier selecting the independent module record or set. |
3 |
|
|
Required |
Point supplying an independent motion in the constraint. |
4 |
|
|
Required |
Component digits whose motion is determined by the constraint. |
Repeated group dependents. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Module containing the dependent side of the connection. |
2 |
|
|
— |
Point whose selected motions are expressed through other degrees of freedom. |
Accepted words: Constant, Element, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the element ID must be an integer from 1 to 99999999.dependentComponents—dependentComponentsmust be a list of the digits 1 to 6, each at most once.dependentNode— the card needs at least one dependent grid point.
Example record
ModuleRigidBodyStar;302;1;112;123456;2;212
Reading the example gives id = 302, independentModuleId = 1, independentNode = 112, dependentComponents = 123456.
ModuleRigidInterpolation¶
The motion of a reference grid point is the weighted average of the motion of other grid points, all of which may lie in different modules (the multi-module counterpart of the RigidInterpolation, whose rules apply).
Record format and fields
ModuleRigidInterpolation;id;referenceModuleId;referenceNode;referenceComponents;<weightedGroups>;<keyed sections>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
0 |
Identifier selecting the reference module record or set. |
3 |
|
|
Required |
Identifier of the grid point serving as the reference for this definition. |
4 |
|
|
Required |
Degrees of freedom used as the reference motion. |
Repeated group weightedGroups. Give the number of entries before their values.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Entity or quantity included in the group with the associated weight. |
Keyed sections in parts
Begin each section with its key, then write its fixed fields and any counted list.
Section DependentDofs
Repeated group dependents. Give the number of entries before their values.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier selecting the dependent module record or set. |
2 |
|
|
— |
Point whose selected motions are expressed through other degrees of freedom. |
3 |
|
|
— |
Component digits whose motion is determined by the constraint. |
Section ThermalExpansion
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
0.0 |
Coefficient in the relation for alpha. |
2 |
|
|
0.0 |
Temperature defining the reference state for these data, in the model’s temperature scale. |
Accepted words: Constant, DependentDofs, Element, Table, ThermalExpansion.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the element ID must be an integer from 1 to 99999999.referenceComponents—referenceComponentsmust be a list of the digits 1 to 6, each at most once.weight1— the card needs at least one weighted group.components—componentsmust be a list of the digits 1 to 6, each at most once.node— a weighted group needs at least one grid point.dependentComponents—dependentComponentsmust be a list of the digits 1 to 6, each at most once.
Example record
ModuleRigidInterpolation;304;;50;123;6;1.;123;1;106;2;206
Reading the example gives id = 304, referenceNode = 50, referenceComponents = 123.
ModuleRigidJoint¶
A rigid joint that connects two coinciding grid points that lie in two different modules (the multi-module counterpart of the RigidJoint, whose rules apply).
Record format and fields
ModuleRigidJoint;id;moduleIdA;nodeA;moduleIdB;nodeB;componentsB
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
0 |
Identifier of the module on side A. |
3 |
|
|
Required |
Grid point identifier at connectivity position A. |
4 |
|
|
0 |
Identifier of the module on side B. |
5 |
|
|
Required |
Grid point identifier at connectivity position B. |
6 |
|
|
— |
Component mask at the indicated endpoint or point. Structural translations use 1–3 and rotations use 4–6. |
Accepted words: Constant, Element, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
componentsB—componentsBmust be a list of the digits 1 to 6, each at most once.
Example record
ModuleRigidJoint;301;;60;2;201;123456
Reading the example gives id = 301, nodeA = 60, moduleIdB = 2, nodeB = 201.
ModuleRigidRod¶
A pin-ended element that is rigid in translation and connects two grid points that lie in two modules (the multi-module counterpart of the RigidRod, whose rules apply).
Record format and fields
ModuleRigidRod;id;moduleIdA;nodeA;moduleIdB;nodeB;componentsAtA;componentsAtB;alphaCoefficient;referenceTemperature
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
0 |
Identifier of the module on side A. |
3 |
|
|
Required |
Grid point identifier at connectivity position A. |
4 |
|
|
0 |
Identifier of the module on side B. |
5 |
|
|
Required |
Grid point identifier at connectivity position B. |
6 |
|
|
0 |
Selected degrees of freedom at point A. |
7 |
|
|
0 |
Selected degrees of freedom at point B. |
8 |
|
|
0.0 |
Coefficient in the relation for alpha. |
9 |
|
|
0.0 |
Temperature defining the reference state for these data, in the model’s temperature scale. |
Accepted words: Constant, Element, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the element ID must be an integer from 1 to 99999999.componentsAtA—componentsAtAmust be 1, 2, 3 or blank.componentsAtB—componentsAtBmust be 1, 2, 3 or blank.
Example record
ModuleRigidRod;303;1;104;2;204;;3
Reading the example gives id = 303, moduleIdA = 1, nodeA = 104, moduleIdB = 2.
ModuleRotation1¶
A rotation of a module about an axis given by two points of the main Bulk Data, optionally turning about a reference point.
Record format and fields
ModuleRotation1;id;referenceNode;startNode;endNode;magnitude
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
0 |
Identifier of the grid point serving as the reference for this definition. |
3 |
|
|
Required |
Grid point at the beginning of the path or directed edge. |
4 |
|
|
Required |
Grid point at the end of the path or directed edge. |
5 |
|
|
Required |
Scale of the quantity applied by this record. Its units follow the load or displacement being specified. |
Accepted words: Constant, Element, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
magnitude—magnitudemust not be zero.
Example record
ModuleRotation1;41;;920;921;90.
Reading the example gives id = 41, startNode = 920, endNode = 921, magnitude = 90..
ModuleRotation2¶
A rotation of a module about an axis of a coordinate system, optionally turning about a reference point.
Record format and fields
ModuleRotation2;id;frameId;referenceNode;axis;magnitude
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
0 |
Coordinate system in which this entry is expressed. |
3 |
|
|
0 |
Identifier of the grid point serving as the reference for this definition. |
4 |
|
|
— |
Coordinate axis about which the definition acts. |
5 |
|
|
Required |
Scale of the quantity applied by this record. Its units follow the load or displacement being specified. |
Accepted words: Constant, Element, MinusXAxis, MinusYAxis, MinusZAxis, Table, XAxis, YAxis, ZAxis.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
magnitude—magnitudemust not be zero.
Example record
ModuleRotation2;51;;920;ZAxis;-90.
Reading the example gives id = 51, referenceNode = 920, axis = ZAxis, magnitude = -90..
ModuleSeam¶
A seam that connects two surface patches (shell elements) that lie in two modules (the multi-module counterpart of the Seam, whose rules apply).
Record format and fields
ModuleSeam;id;propId;seamLineName;patchKind;startPatchIdA;startPatchIdB;endPatchIdA;endPatchIdB;startNode;xStation;endNode;yStation;zStation;xEnd;yEnd;zEnd;moduleIdA;moduleIdB
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
Required |
Identifier of the property from which the element obtains its section or constitutive data. |
3 |
|
|
— |
Text naming the seam line. |
4 |
|
|
— |
Selects the patch kind for ModuleSeam. |
5 |
|
|
Required |
Identifier at the start of the patch range on side A. |
6 |
|
|
0 |
Identifier at the start of the patch range on side B. |
7 |
|
|
0 |
Identifier at the end of the patch range on side A. |
8 |
|
|
0 |
Identifier at the end of the patch range on side B. |
9 |
|
|
— |
Grid point at the beginning of the path or directed edge. Alternative to |
10 |
|
|
— |
X coordinate of the evaluation station. Alternative to |
11 |
|
|
— |
Grid point at the end of the path or directed edge. Alternative to |
12 |
|
|
— |
Y coordinate of the evaluation station. Alternative to |
13 |
|
|
— |
Z coordinate of the evaluation station. |
14 |
|
|
— |
x coordinate of the endpoint. |
15 |
|
|
— |
y coordinate of the endpoint. |
16 |
|
|
— |
z coordinate of the endpoint. |
17 |
|
|
0 |
Identifier of the module on side A. |
18 |
|
|
0 |
Identifier of the module on side B. |
Accepted words: Constant, Element, Elements, ShellProp, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the element ID must be an integer from 1 to 99999999.startNode—startNodeis required and must be a positive integer.endNode—endNodeis required and must be a positive integer.
Example record
ModuleSeam;308;33;;ShellProp;11;12;;;;32.;;15.;1.5;38.;15.;1.5;1;2
Reading the example gives id = 308, propId = 33, patchKind = ShellProp, startPatchIdA = 11.
ModuleStructureSet¶
Identifies the structural points or elements in a module that participate in a FluidStructureInterface.
Record format and fields
ModuleStructureSet;moduleId;<ids>
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
0 |
Identifier selecting the module record or set. |
Repeated group ids. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier carried by the record. |
Accepted words: All, Through.
Example record
ModuleStructureSet;0;1;Through;9
Reading the example gives moduleId = 0.
ModuleTranslation¶
A translation of a module, given as a vector between two points of the main Bulk Data.
Record format and fields
ModuleTranslation;id;startNode;endNode;magnitude
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
Required |
Grid point at the beginning of the path or directed edge. |
3 |
|
|
Required |
Grid point at the end of the path or directed edge. |
4 |
|
|
0.0 |
Scale of the quantity applied by this record. Its units follow the load or displacement being specified. |
Accepted words: Constant, Element, Table.
Example record
ModuleTranslation;62;941;942
Reading the example gives id = 62, startNode = 941, endNode = 942.
ModuleWeld¶
A weld or fastener that connects two surface patches, a point and a patch, or two points, between two modules (the multi-module counterpart of the Weld, whose rules apply).
Record format and fields
ModuleWeld;id;propId;spotNode;kind;nodeA;nodeB;patchTypes;matFrameId;patchIdA;patchIdB;spotModuleId;moduleIdA;moduleIdB;nodeA1;xStation;nodeA2;yStation;nodeA3;zStation;nodeA4;nodeA5;nodeA6;nodeA7;nodeA8;nodeB1;nodeB2;nodeB3;nodeB4;nodeB5;nodeB6;nodeB7;nodeB8
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
Required |
Identifier of the property from which the element obtains its section or constitutive data. |
3 |
|
|
0 |
Grid point locating the connection spot. |
4 |
|
|
— |
Selects the kind for ModuleWeld. |
5 |
|
|
0 |
Grid point identifier at connectivity position A. |
6 |
|
|
0 |
Grid point identifier at connectivity position B. |
7 |
|
|
— |
Categories of patches included in the selection. |
8 |
|
|
— |
Coordinate system defining the material directions. |
9 |
|
|
— |
Identifier of the patch on side A. |
10 |
|
|
— |
Identifier of the patch on side B. |
11 |
|
|
0 |
Identifier selecting the spot module record or set. |
12 |
|
|
0 |
Identifier of the module on side A. |
13 |
|
|
0 |
Identifier of the module on side B. |
14 |
|
|
— |
Identifier of the grid point on side A at position 1. Alternative to |
15 |
|
|
— |
X coordinate of the evaluation station. Alternative to |
16 |
|
|
— |
Identifier of the grid point on side A at position 2. Alternative to |
17 |
|
|
— |
Y coordinate of the evaluation station. Alternative to |
18 |
|
|
— |
Identifier of the grid point on side A at position 3. Alternative to |
19 |
|
|
— |
Z coordinate of the evaluation station. Alternative to |
20 |
|
|
— |
Identifier of the grid point on side A at position 4. |
21 |
|
|
— |
Identifier of the grid point on side A at position 5. |
22 |
|
|
— |
Identifier of the grid point on side A at position 6. |
23 |
|
|
— |
Identifier of the grid point on side A at position 7. |
24 |
|
|
— |
Identifier of the grid point on side A at position 8. |
25 |
|
|
— |
Identifier of the grid point on side B at position 1. |
26 |
|
|
— |
Identifier of the grid point on side B at position 2. |
27 |
|
|
— |
Identifier of the grid point on side B at position 3. |
28 |
|
|
— |
Identifier of the grid point on side B at position 4. |
29 |
|
|
— |
Identifier of the grid point on side B at position 5. |
30 |
|
|
— |
Identifier of the grid point on side B at position 6. |
31 |
|
|
— |
Identifier of the grid point on side B at position 7. |
32 |
|
|
— |
Identifier of the grid point on side B at position 8. |
Accepted words: AlignedNodes, Constant, ElemIdPatch, ElemPatch, Element, NodeIdPatch, PartPatch, QuadPatch, QuadQuadPatch, QuadTriaPatch, Table, TriaPatch, TriaQuadPatch, TriaTriaPatch.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the element ID must be an integer from 1 to 99999999.matFrameId—matFrameIdmust be -1 (blank) or a coordinate system ID.nodeA1— the grid point IDs must not be negative.patchIdB— the two patches must be different.
Example record
ModuleWeld;307;32;;PartPatch;;;;;11;12;;1;2;;25.;;15.;;1.5
Reading the example gives id = 307, propId = 32, kind = PartPatch, patchIdA = 11.
Node¶
A grid point with a position, an input coordinate system and a coordinate system for its displacement components.
Record format and fields
Node;id;positionFrameId;position1;position2;position3;displacementFrameId;permanentConstraints;superelementId
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Unique grid point identifier used by connectivity, loads and constraints. |
2 |
|
|
0 |
Coordinate system used to interpret the position coordinates. |
3 |
|
|
0.0 |
First coordinate in the position frame. It is x in a rectangular frame and radius in a cylindrical or spherical frame. |
4 |
|
|
0.0 |
Second coordinate in the position frame. It is y in a rectangular frame and an angle in cylindrical or spherical coordinates. |
5 |
|
|
0.0 |
Third coordinate in the position frame. It is z in rectangular and cylindrical coordinates and an angle in spherical coordinates. |
6 |
|
|
0 |
Coordinate system in which the displacement components are expressed. |
7 |
|
|
0 |
Component digits fixed at this node in its displacement frame. |
8 |
|
|
0 |
Identifier of the superelement associated with the entry. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the ID must be a positive integer.positionFrameId—positionFrameIdmust be 0 or a coordinate system ID.displacementFrameId—displacementFrameIdmust be -1, 0 or a coordinate system ID.permanentConstraints—permanentConstraintsmust be digits 1 to 6 with no repeat.
Example record
Node;1;1;50.;0.;0.;1
Reading the example gives id = 1, positionFrameId = 1, position1 = 50., position2 = 0..
Referenced records in this example
CylindricalFrame2 via
positionFrameId = 1,displacementFrameId = 1.
NodeDefaults¶
Supplies default position and displacement frames, permanent constraints and superelement membership for Node records with blank fields.
Record format and fields
NodeDefaults;positionFrameId;displacementFrameId;permanentConstraints;superelementId
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
0 |
Coordinate system used to interpret the position coordinates. |
2 |
|
|
0 |
Coordinate system in which the displacement components are expressed. |
3 |
|
|
0 |
Permanent single-point constraints, as digits 1..6 (0 = none). |
4 |
|
|
0 |
Identifier of the superelement associated with the entry. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
positionFrameId—positionFrameIdmust be 0 or a coordinate system ID.displacementFrameId—displacementFrameIdmust be -1, 0 or a coordinate system ID.permanentConstraints—permanentConstraintsmust be digits 1 to 6 with no repeat.superelementId—superelementIdmust be 0 or a superelement ID.
Example record
NodeDefaults;10;10
Reading the example gives positionFrameId = 10, displacementFrameId = 10.
NodeSequence¶
The sequence in which grid and scalar points are ordered (manual resequencing).
Record format and fields
NodeSequence;<points>
This part of the record has no fixed fields.
Repeated group points. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Grid point to which this entry applies. |
2 |
|
|
— |
Identifier selecting the sequence record or set. |
Accepted words: Through.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
node1— the card needs at least one point.node1— the card has at most four points.node1— a grid or scalar point ID must be a positive integer.sequenceId1— a sequence number must be greater than zero.
Example record
NodeSequence;461;406.5;441;403.5
ScalarPoint¶
Defines scalar grid-free degrees of freedom by their point identifiers.
Record format and fields
ScalarPoint;<ids>
This part of the record has no fixed fields.
Repeated group ids. Repeat these fields in order for each entry.
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
— |
Identifier in the node namespace. |
Accepted words: Through.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
id— the scalar point ID must be a positive integer.
Example record
ScalarPoint;1001;Through;1008
ShellNormal¶
The surface normal vector at a grid point, for the ShellQuad4, ShellQuad4Drilling, ShellTria3 and ShellTria3Drilling shell elements.
Record format and fields
ShellNormal;nodeId;frameId;directionX;directionY;directionZ
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier of the grid point addressed by this record. |
2 |
|
|
0 |
Coordinate system in which this entry is expressed. |
3 |
|
|
0.0 |
X component of the specified direction vector in its reference frame. |
4 |
|
|
0.0 |
Y component of the specified direction vector in its reference frame. |
5 |
|
|
0.0 |
Z component of the specified direction vector in its reference frame. |
Accepted words: Constant, Element, Table.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
frameId—frameIdmust be 0 or a coordinate system ID.
Example record
ShellNormal;1111;10;1.;0.;0.
Reading the example gives nodeId = 1111, frameId = 10, directionX = 1., directionY = 0..
Referenced records in this example
Node via
nodeId = 1111.
SurfaceEdge¶
Declares how the surface continues across an edge between two nodes. A declaration may apply to one incident element when its state permits this.
Record format and fields
SurfaceEdge;id;node1Id;node2Id;state;elementId
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
Required |
Grid point at one end of the declared edge. |
3 |
|
|
Required |
Grid point at the other end of the declared edge. |
4 |
|
|
— |
Surface continuation at this edge. Smooth continues the tangent plane, Sharp marks a fold and Raw retains the mesh edge. |
5 |
|
|
0 |
Optional incident element restricting the declaration to its side of the edge. |
Accepted words: Raw, Sharp, Smooth.
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
node1Id— the two grid points of the edge must be different.state—stateis required: Smooth, Sharp or Raw.state—statemust be Smooth, Sharp or Raw.elementId—elementIdmust be blank whenstateis Raw.
Example record
SurfaceEdge;1;301;302;Smooth
Reading the example gives id = 1, node1Id = 301, node2Id = 302, state = Smooth.
SurfaceFacet¶
Declares an existing shell element to be a flat facet bounded by straight folds. The element ID also identifies its declaration.
Record format and fields
SurfaceFacet;elementId
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier of the existing shell element whose face is declared planar. |
Example record
SurfaceFacet;501
Reading the example gives elementId = 501.
SurfaceLine¶
Declares the path or end of a surface line through an ordered sequence of grid points.
Record format and fields
SurfaceLine;id;node1Id;throughNodeId;node2Id
Position |
Field |
Type |
Default |
Meaning and conventions |
|---|---|---|---|---|
1 |
|
|
Required |
Identifier in the namespace of this card type. |
2 |
|
|
Required |
First grid point defining the line direction. |
3 |
|
|
Required |
Grid point at which the line continues or terminates. |
4 |
|
|
0 |
Next grid point on the line. Omit it to declare a line end. |
Reader diagnostics
The following messages identify invalid input for the applicable field or form.
node1Id—node1IdandthroughNodeIdmust be different.node2Id—node2Idmust be different fromnode1IdandthroughNodeId.
Example record
SurfaceLine;1;501;502;503
Reading the example gives id = 1, node1Id = 501, throughNodeId = 502, node2Id = 503.