Design and optimization

All card families and alphabetical index

Read field positions from left to right within each table. A dash means the layout supplies no fixed default. Use a consistent system of units for dimensional quantities.

DesignBeadRegion

A design region of a topography (bead or stamp) optimisation: the nodes of the elements of one property, which the beads of the given size move.

Record format and fields

DesignBeadRegion;id;propType;propId;minWidth;maxHeight;angle;bufferZone;skippedNodes;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

propType

text

—

Selects the property type for DesignBeadRegion.

3

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

4

minWidth

real

Required

Minimum width (length).

5

maxHeight

real

Required

Maximum permitted height in the design region (length).

6

angle

real

Required

Angular position or orientation relative to the reference on this card.

7

bufferZone

text

Yes

Extent of the transition zone surrounding the selected design region.

8

skippedNodes

text

Both

Grid points excluded from the operation on the design region.

Keyed sections in lines

Begin each section with its key, then write its fixed fields and any counted list.

Section DesignVar

Position

Field

Type

Default

Meaning and conventions

1

directionX

real

—

X component of the specified direction vector in its reference frame.

2

directionY

real

—

Y component of the specified direction vector in its reference frame.

3

directionZ

real

—

Z component of the specified direction vector in its reference frame.

4

frameId

integer

—

Coordinate system in which this entry is expressed.

5

lowerBound

real

—

Lower limit expressed in the same units as the bounded quantity.

6

upperBound

real

—

Upper limit expressed in the same units as the bounded quantity.

7

designVarMoveLimit

real

—

Limits the change allowed for this design variable in one optimization update.

Section Nodes

Position

Field

Type

Default

Meaning and conventions

1

excludedNodeSetId

integer

—

Identifier selecting the excluded node set record or set.

2

addedNodeSetId

integer

—

Identifier selecting the added node set record or set.

Accepted words: Both, BoundaryCondition, CompProp, CompPropGlobal, Constant, DesignVar, Element, ElementNormals, Load, No, Nodes, None, ShearPanelProp, ShellProp, Table, Yes.

Example record

DesignBeadRegion;3;ShellProp;3;20.;4.;60.;;;DesignVar;ElementNormals;;;;-1.;1.

Model containing this record

Reading the example gives id = 3, propType = ShellProp, propId = 3, minWidth = 20..

DesignBoundaryShape

A boundary shape vector, as a combination of the vectors that the load sequences of an auxiliary model give.

Record format and fields

DesignBoundaryShape;designVarId;auxiliaryModified;column1;scaleFactor1;column2;scaleFactor2;column3;scaleFactor3

Position

Field

Type

Default

Meaning and conventions

1

designVarId

integer

Required

Identifier of the design variable supplying the independent value.

2

auxiliaryModified

integer

Required

Selection controlling how the auxiliary design data are modified.

3

column1

integer

—

Column identifier for contribution 1 of the displacement or shape basis.

4

scaleFactor1

real

1.0

Multiplier applied to the quantity specified by the entry. Entry 1.

5

column2

integer

—

Column identifier for contribution 2 of the displacement or shape basis.

6

scaleFactor2

real

1.0

Multiplier applied to the quantity specified by the entry. Entry 2.

7

column3

integer

—

Column identifier for contribution 3 of the displacement or shape basis.

8

scaleFactor3

real

1.0

Multiplier applied to the quantity specified by the entry. Entry 3.

Accepted words: Constant, Element, Table.

Example record

DesignBoundaryShape;1;1;10;1.

Model containing this record

Reading the example gives designVarId = 1, auxiliaryModified = 1, column1 = 10, scaleFactor1 = 1..

DesignConstants

Named real constants for the equations of the design relations and responses.

Record format and fields

DesignConstants;<entries>

This part of the record has no fixed fields.

Repeated group entries. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

label

text

—

Text identifying the entry to the user or to records which select it by label.

2

constantValue

number

—

Fixed value entering the design relation or response.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • label — at least one constant is required.

Example record

DesignConstants;KI1;0.5;KI2;0.01389;RATIO;6.

Model containing this record

DesignConstr

The bounds of one response, in a set of design constraints.

Record format and fields

DesignConstr;constraintSetId;responseId;lowerAllowable;lowerAllowableTableId;upperAllowable;upperAllowableTableId;lowFrequency;highFrequency

Position

Field

Type

Default

Meaning and conventions

1

constraintSetId

integer

Required

Identifier selecting the constraint set record or set.

2

responseId

integer

Required

Identifier selecting the response record or set.

3

lowerAllowable

real

-1.0e20

Lower admissible value of the constrained response. Alternative to lowerAllowableTableId.

4

lowerAllowableTableId

integer

—

Table supplying the variation of lower allowable. Alternative to lowerAllowable.

5

upperAllowable

real

1.0e20

Upper admissible value of the constrained response. Alternative to upperAllowableTableId.

6

upperAllowableTableId

integer

—

Table supplying the variation of upper allowable. Alternative to upperAllowable.

7

lowFrequency

real

0.0

Low frequency (inverse time).

8

highFrequency

real

1.0e20

High frequency (inverse time).

Accepted words: Constant, Element, Table.

Example record

DesignConstr;31;22;-1.;;1.

Model containing this record

Reading the example gives constraintSetId = 31, responseId = 22, lowerAllowable = -1., upperAllowable = 1..

DesignConstrScreen

The screening of the constraints of one response type, to the most critical ones.

Record format and fields

DesignConstrScreen;responseKind;threshold;maxRetained

Position

Field

Type

Default

Meaning and conventions

1

responseKind

text

—

Selects the response kind for DesignConstrScreen.

2

threshold

real

-0.5

Value at which the selected test changes state.

3

maxRetained

integer

20

Maximum number of responses or constraints kept by the screening operation.

Accepted words: AbsoluteDisplacement, AbsoluteStress, AcousticFieldIntensity, AcousticFieldPressure, AcousticFieldVelocity, AcousticIntensity, AcousticPower, All, BucklingFactor, ComplexEigenvalue, Compliance, CompositeFailure, CompositeStrain, CompositeStrengthRatio, CompositeStress, Constant, ConstraintForce, ContourDisplacement, ContourForce, CutLoad, DeflectionToThickness, DesignResp3, Displacement, Divergence, DynamicStiffness, Eigenvalue, Element, Equation, Fatigue, Flutter, Force, FractionalMass, FreqAcceleration, FreqConstraintForce, FreqDisplacement, FreqFatigue, FreqForce, FreqStress, FreqVelocity, Frequency, MeanDisplacement, NodeForce, NodeForcePanel, Pressure, RadiatedPower, RootMeanSquareAcceleration, RootMeanSquareDisplacement, RootMeanSquareVelocity, Rotation, SectionLoad, SpectralAcceleration, SpectralDisplacement, SpectralVelocity, StabilityDerivative, Strain, StrainEnergy, Stress, Table, TotalCompliance, TotalStrainEnergy, TransientAcceleration, TransientConstraintForce, TransientDisplacement, TransientForce, TransientStress, TransientVelocity, TrimVariable, Volume, Weight, WeightPerPropertyId.

Accepted parameter names: RetainedConstraintCount, ScreeningThreshold.

Example record

DesignConstrScreen;Stress;-0.6;3

Model containing this record

Reading the example gives responseKind = Stress, threshold = -0.6, maxRetained = 3.

DesignConstrUnion

The design constraints of a subcase as the union of several DesignConstr sets.

Record format and fields

DesignConstrUnion;constraintSetId;<memberSets>

Position

Field

Type

Default

Meaning and conventions

1

constraintSetId

integer

Required

Identifier selecting the constraint set record or set.

Repeated group memberSets. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

memberSetId

integer

—

Identifier selecting the member set record or set.

Accepted words: Constant, Element, Table.

Example record

DesignConstrUnion;100;41;42

Model containing this record

Reading the example gives constraintSetId = 100.

DesignControlSurface

The setting of a control surface in a trim case as a design variable times a coefficient.

Record format and fields

DesignControlSurface;id;controlSurfaceLabel;trimId;designVarId;coefficient

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

controlSurfaceLabel

text

—

Text naming the control surface.

3

trimId

integer

Required

Identifier selecting the trim record or set.

4

designVarId

integer

Required

Identifier of the design variable supplying the independent value.

5

coefficient

real

Required

Coefficient value in the DesignControlSurface relation.

Accepted words: Constant, Element, Table.

Example record

DesignControlSurface;11;ELEV;1;1;1.

Model containing this record

Reading the example gives id = 11, controlSurfaceLabel = ELEV, trimId = 1, designVarId = 1.

DesignDiscreteValues

Defines a list of admissible values for discrete design variables, topometry or rotor-speed selections.

Record format and fields

DesignDiscreteValues;id;<discreteValues>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group discreteValues. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

discreteValue

any

—

One permitted value in the discrete design set.

Accepted words: By, Constant, Element, Table, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • values — at least one value is required.

  • increment — the range has more than a million values: check its increment.

Example record

DesignDiscreteValues;50;0.5;Through;2.;By;0.25

Model containing this record

Reading the example gives id = 50.

DesignElemRelation1

A field of an element as a linear function of design variables.

Record format and fields

DesignElemRelation1;id;kind;elemId;fieldName;minValue;maxValue;constant0;<terms>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

kind

text

—

Selects the kind for DesignElemRelation1.

3

elemId

integer

Required

Identifier of the element addressed by this record.

4

fieldName

text

—

Name of the field addressed by this entry.

5

minValue

real

—

Smallest value retained or permitted for the selected quantity.

6

maxValue

real

1.0e20

Largest value retained or permitted for the selected quantity.

7

constant0

real

0.0

Coefficient 0 in the DesignElemRelation1 relation.

Repeated group terms. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

designVarId

integer

—

Identifier of the design variable supplying the independent value.

2

coefficient

any

—

Coefficient value in the DesignElemRelation1 relation for terms.

Accepted words: Constant, Element, PropertyValue, Table.

Example record

DesignElemRelation1;301;ShellQuad4;4;offset;-1.;1.;;5;1.

Model containing this record

Reading the example gives id = 301, kind = ShellQuad4, elemId = 4, fieldName = offset.

DesignElemRelation2

A field of an element as the value of a DesignEquation equation of design variables and constants.

Record format and fields

DesignElemRelation2;id;kind;elemId;fieldName;minValue;maxValue;equationId;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

kind

text

—

Selects the kind for DesignElemRelation2.

3

elemId

integer

Required

Identifier of the element addressed by this record.

4

fieldName

text

—

Name of the field addressed by this entry.

5

minValue

real

—

Smallest value retained or permitted for the selected quantity.

6

maxValue

real

1.0e20

Largest value retained or permitted for the selected quantity.

7

equationId

integer

Required

Identifier selecting the equation record or set.

Keyed sections in variables

Begin each section with its key, then write its fixed fields and any counted list.

Section DesignVar

Repeated group designVariables. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

designVarId

integer

—

Identifier of the design variable supplying the independent value.

Section DesignConstants

Repeated group constants. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

constantLabel

text

—

Text naming the constant.

Accepted words: Constant, DesignConstants, DesignVar, Element, Table.

Example record

DesignElemRelation2;24;Bar2;31;orientation3;;;23;DesignVar;1;5

Model containing this record

Reading the example gives id = 24, kind = Bar2, elemId = 31, fieldName = orientation3.

DesignEquation

A numbered set of equations.

Record format and fields

DesignEquation;id;equation

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

equation

text

—

Expression or reference defining the response from its arguments.

Example record

DesignEquation;23;XV(A) = A

Model containing this record

Reading the example gives id = 23, equation = XV(A) = A.

DesignFieldConstants

Constants that are the value of a field of a property, a material or a connection of the analysis model (taken before the design variables change it).

Record format and fields

DesignFieldConstants;<entries>

This part of the record has no fixed fields.

Repeated group entries. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

label

text

—

Text identifying the entry to the user or to records which select it by label.

2

targetCard

text

—

Type or identifier of the model entry to which the design relation applies.

3

targetId

integer

—

Identifier selecting the target record or set.

4

fieldName

text

—

Name of the field addressed by this entry.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • label — at least one constant is required.

Example record

DesignFieldConstants;T1REF;ShellProp;1;thickness;T2REF;ShellProp;2;thickness

Model containing this record

DesignLoadRelation1

A value of a load as a linear function of design variables.

Record format and fields

DesignLoadRelation1;id;kind;setId;fieldName;minValue;maxValue;constant0;attribute1;attribute2;attribute3;attribute4;attribute5;<terms>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

kind

text

—

Selects the kind for DesignLoadRelation1.

3

setId

integer

Required

Identifier selecting the set record or set.

4

fieldName

text

—

Name of the field addressed by this entry.

5

minValue

real

-1.0e35

Smallest value retained or permitted for the selected quantity.

6

maxValue

real

1.0e20

Largest value retained or permitted for the selected quantity.

7

constant0

real

0.0

Coefficient 0 in the DesignLoadRelation1 relation.

8

attribute1

integer

—

Attribute of the indicated design target used in the response or relation. Entry 1.

9

attribute2

integer

—

Attribute of the indicated design target used in the response or relation. Entry 2.

10

attribute3

integer

—

Attribute of the indicated design target used in the response or relation. Entry 3.

11

attribute4

integer

—

Attribute of the indicated design target used in the response or relation. Entry 4.

12

attribute5

integer

—

Attribute of the indicated design target used in the response or relation. Entry 5.

Repeated group terms. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

designVarId

integer

—

Identifier of the design variable supplying the independent value.

2

coefficient

any

—

Coefficient value in the DesignLoadRelation1 relation for terms.

Accepted words: Constant, Element, LoadCombination, PointForceLoad, PointMomentLoad, PropertyValue, Table.

Example record

DesignLoadRelation1;401;PointForceLoad;2;magnitude;;;;10;;;;;6;1.

Model containing this record

Reading the example gives id = 401, kind = PointForceLoad, setId = 2, fieldName = magnitude.

DesignMatRelation1

A field of a material as a linear function of design variables.

Record format and fields

DesignMatRelation1;id;kind;matId;fieldName;minValue;maxValue;constant0;<terms>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

kind

text

—

Selects the kind for DesignMatRelation1.

3

matId

integer

Required

Material identifier used to retrieve the constitutive data.

4

fieldName

text

—

Name of the field addressed by this entry.

5

minValue

real

—

Smallest value retained or permitted for the selected quantity.

6

maxValue

real

1.0e20

Largest value retained or permitted for the selected quantity.

7

constant0

real

0.0

Coefficient 0 in the DesignMatRelation1 relation.

Repeated group terms. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

designVarId

integer

—

Identifier of the design variable supplying the independent value.

2

coefficient

any

—

Coefficient value in the DesignMatRelation1 relation for terms.

Accepted words: Constant, Element, PropertyValue, Table.

Example record

DesignMatRelation1;201;IsoMat;2;youngsModulus;6.E+4;8.E+4;;4;PropertyValue

Model containing this record

Reading the example gives id = 201, kind = IsoMat, matId = 2, fieldName = youngsModulus.

DesignMatRelation2

A field of a material as the value of a DesignEquation equation of design variables and constants.

Record format and fields

DesignMatRelation2;id;kind;matId;fieldName;minValue;maxValue;equationId;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

kind

text

—

Selects the kind for DesignMatRelation2.

3

matId

integer

Required

Material identifier used to retrieve the constitutive data.

4

fieldName

text

—

Name of the field addressed by this entry.

5

minValue

real

—

Smallest value retained or permitted for the selected quantity.

6

maxValue

real

1.0e20

Largest value retained or permitted for the selected quantity.

7

equationId

integer

Required

Identifier selecting the equation record or set.

Keyed sections in variables

Begin each section with its key, then write its fixed fields and any counted list.

Section DesignVar

Repeated group designVariables. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

designVarId

integer

—

Identifier of the design variable supplying the independent value.

Section DesignConstants

Repeated group constants. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

constantLabel

text

—

Text naming the constant.

Accepted words: Constant, DesignConstants, DesignVar, Element, Table.

Example record

DesignMatRelation2;22;IsoMat;1;youngsModulus;;;21;DesignVar;1;4

Model containing this record

Reading the example gives id = 22, kind = IsoMat, matId = 1, fieldName = youngsModulus.

DesignNodeMove

How a design variable moves a grid point.

Record format and fields

DesignNodeMove;designVarId;nodeId;frameId;coefficient;directionX;directionY;directionZ

Position

Field

Type

Default

Meaning and conventions

1

designVarId

integer

Required

Identifier of the design variable supplying the independent value.

2

nodeId

integer

Required

Identifier of the grid point addressed by this record.

3

frameId

integer

0

Coordinate system in which this entry is expressed.

4

coefficient

real

0.0

Coefficient value in the DesignNodeMove relation.

5

directionX

real

0.0

X component of the specified direction vector in its reference frame.

6

directionY

real

0.0

Y component of the specified direction vector in its reference frame.

7

directionZ

real

0.0

Z component of the specified direction vector in its reference frame.

Accepted words: Constant, Element, Table.

Example record

DesignNodeMove;3;5;0;1.;0.;0.;1.

Model containing this record

Reading the example gives designVarId = 3, nodeId = 5, frameId = 0, coefficient = 1..

DesignOptimParams

Overrides named optimization controls in a design model.

Record format and fields

DesignOptimParams;<parameters>

This part of the record has no fixed fields.

Repeated group parameters. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

any

—

Value assigned to the named parameter. Its interpretation depends on that name.

Accepted words: Constant, Element, Table.

Accepted parameter names: AbsoluteObjectiveChange, AbsoluteObjectiveConvergence, ApproximationMethod, AutomaticSuperelementCreation, ConstraintActiveThreshold, ConstraintScale, ConstraintViolationThreshold, DesignVarConvergence, DesignVarMoveLimit, DesignVarScaling, DiscreteMethod, DiscreteStartCycle, EquivalentLoadMaxCycles, EquivalentLoadMoveLimit, FiniteDifferenceStep, FullyStressedMaxCycles, FullyStressedRelaxation, MaxConstraintViolation, MaxDesignCycles, MaxDesignVarChange, MaxPropertyChange, MinDesignVarChange, MinPropertyChange, ObjectiveRelativeToStart, OptimizationMethod, OptimizerName, OptimizerPrintLevel, PenaltyFactor, PrintAnalysisEveryCycle, PrintApproximation, PrintBeadConstraints, PrintConstraintCount, PrintDiscreteVars, PrintInterval, PrintItems, PrintMaterialCount, PrintMaxRetained, PrintPropertyCount, PrintResponseCount, PrintResponseSet, PropertyConvergence, PropertyLimitViolation, PropertyMoveLimit, PropertyTolerance, RelativeObjectiveChange, RelativeObjectiveConvergence, StepScale, SuperelementStopRatio, TopologyCheckerboard, TopologyMinMember, TopologyRegion, TrustRegionGrowthFactor, TrustRegionHighRatio, TrustRegionLowRatio, TrustRegionMiddleRatio, TrustRegionShrinkFactor, ViolationTreatment.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • parameterName — at least one parameter is required.

Example record

DesignOptimParams;MaxDesignCycles;5;PrintInterval;1;PrintItems;15

Model containing this record

DesignPropRelation1

A field of a property as a linear function of design variables.

Record format and fields

DesignPropRelation1;id;kind;propId;fieldName;minValue;maxValue;constant0;<terms>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

kind

text

—

Selects the kind for DesignPropRelation1.

3

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

4

fieldName

text

—

Name of the field addressed by this entry.

5

minValue

real

—

Smallest value retained or permitted for the selected quantity.

6

maxValue

real

1.0e20

Largest value retained or permitted for the selected quantity.

7

constant0

real

0.0

Coefficient 0 in the DesignPropRelation1 relation.

Repeated group terms. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

designVarId

integer

—

Identifier of the design variable supplying the independent value.

2

coefficient

any

—

Coefficient value in the DesignPropRelation1 relation for terms.

Accepted words: Constant, Element, PropertyValue, Table.

Example record

DesignPropRelation1;11;ShellProp;1;thickness;;;;2;1.

Model containing this record

Reading the example gives id = 11, kind = ShellProp, propId = 1, fieldName = thickness.

DesignPropRelation2

A field of a property as the value of a DesignEquation equation of design variables and constants.

Record format and fields

DesignPropRelation2;id;kind;propId;fieldName;minValue;maxValue;equationId;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

kind

text

—

Selects the kind for DesignPropRelation2.

3

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

4

fieldName

text

—

Name of the field addressed by this entry.

5

minValue

real

—

Smallest value retained or permitted for the selected quantity.

6

maxValue

real

1.0e20

Largest value retained or permitted for the selected quantity.

7

equationId

integer

Required

Identifier selecting the equation record or set.

Keyed sections in variables

Begin each section with its key, then write its fixed fields and any counted list.

Section DesignVar

Repeated group designVariables. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

designVarId

integer

—

Identifier of the design variable supplying the independent value.

Section DesignConstants

Repeated group constants. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

constantLabel

text

—

Text naming the constant.

Accepted words: Constant, DesignConstants, DesignVar, Element, Table.

Example record

DesignPropRelation2;103;BarProp;3;area;10.;100.;22;DesignVar;1;3

Model containing this record

Reading the example gives id = 103, kind = BarProp, propId = 3, fieldName = area.

DesignResp1

Defines a structural response, such as weight, displacement, stress or frequency, for an optimization objective or constraint.

Record format and fields

DesignResp1;id;entryLabel;responseKind;ownerKind;regionId;attributeA;attributeB;<attributes>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

entryLabel

text

—

User label associated with the entry.

3

responseKind

text

—

Selects the response kind for DesignResp1.

4

ownerKind

any

—

Selects the owner kind for DesignResp1.

5

regionId

integer

0

Identifier of the region on which the definition acts.

6

attributeA

any

—

First attribute used to qualify the design response.

7

attributeB

any

—

Second attribute used to qualify the design response.

Repeated group attributes. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

attribute

any

—

Attribute of the indicated design target used in the response or relation.

Accepted words: AbsoluteDisplacement, AbsoluteStress, AcousticFieldIntensity, AcousticFieldPressure, AcousticFieldVelocity, AcousticIntensity, AcousticPower, All, Alpha, Average, BucklingFactor, ComplexEigenvalue, Compliance, CompositeFailure, CompositeStrain, CompositeStrengthRatio, CompositeStress, Constant, ConstraintForce, ContourDisplacement, ContourForce, CutLoad, DeflectionToThickness, Displacement, Divergence, DynamicStiffness, Eigenvalue, Element, Elements, Fatigue, Fluid, Flutter, Force, FractionalMass, FreqAcceleration, FreqConstraintForce, FreqDisplacement, FreqFatigue, FreqForce, FreqStress, FreqVelocity, Frequency, KMethod, KMethodEfficient, MeanDisplacement, NodeForce, NodeForcePanel, Omega, PkMethod, PkMethodNoLoop, PkMethodNoLoopSweep, PkMethodSweep, Pressure, RadiatedPower, RootMeanSquareAcceleration, RootMeanSquareDisplacement, RootMeanSquareVelocity, Rotation, SectionLoad, SpectralAcceleration, SpectralDisplacement, SpectralVelocity, StabilityDerivative, Strain, StrainEnergy, Stress, Structure, Table, Through, TotalCompliance, TotalStrainEnergy, TransientAcceleration, TransientConstraintForce, TransientDisplacement, TransientForce, TransientStress, TransientVelocity, TrimVariable, Volume, Weight, WeightPerPropertyId.

Example record

DesignResp1;35;BARSA;Stress;BarProp;;7;;3

Model containing this record

Reading the example gives id = 35, entryLabel = BARSA, responseKind = Stress, ownerKind = BarProp.

DesignResp2

Combines design variables, constants and other responses through a built-in function or a DesignEquation.

Record format and fields

DesignResp2;id;entryLabel;equationId;function;regionId;methodName;constant1;constant2;constant3;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

entryLabel

text

—

User label associated with the entry.

3

equationId

integer

—

Identifier selecting the equation record or set. Alternative to function.

4

function

text

—

Selects the function used to combine or evaluate the supplied arguments. Alternative to equationId.

5

regionId

integer

0

Identifier of the region on which the definition acts.

6

methodName

text

—

Text naming the method.

7

constant1

real

1.0

Coefficient 1 in the DesignResp2 relation.

8

constant2

real

0.005

Coefficient 2 in the DesignResp2 relation.

9

constant3

real

10.0

Coefficient 3 in the DesignResp2 relation.

Keyed sections in arguments

Begin each section with its key, then write its fixed fields and any counted list.

Section DesignVar

Repeated group designVariables. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

designVarId

integer

—

Identifier of the design variable supplying the independent value.

Section DesignConstants

Repeated group constants. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

constantLabel

text

—

Text naming the constant.

Section DesignResp1

Repeated group responses. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

responseId

integer

—

Identifier selecting the response record or set.

Section DesignNodes

Repeated group nodeComponents. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

nodeId

integer

—

Identifier of the grid point addressed by this record.

2

nodeComponent

integer

—

Number of the degree of freedom at the associated point.

Section DesignPropRelation1

Repeated group propRelations. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

propRelationId

integer

—

Identifier selecting the property relation record or set.

Section DesignElemRelation1

Repeated group elemRelations. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

elemRelationId

integer

—

Identifier selecting the element relation record or set.

Section DesignMatRelation1

Repeated group matRelations. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

matRelationId

integer

—

Identifier selecting the material relation record or set.

Section DesignPropRelation2

Repeated group propRelations2. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

propRelation2Id

integer

—

Identifier selecting the property relation 2 record or set.

Section DesignElemRelation2

Repeated group elemRelations2. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

elemRelation2Id

integer

—

Identifier selecting the element relation 2 record or set.

Section DesignMatRelation2

Repeated group matRelations2. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

matRelation2Id

integer

—

Identifier selecting the material relation 2 record or set.

Section DesignResp2

Repeated group combinedResponses. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

combinedResponseId

integer

—

Identifier selecting the combined response record or set.

Section DesignLoadRelation1

Repeated group loadRelations. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

loadRelationId

integer

—

Identifier selecting the load relation record or set.

Accepted words: Average, BetaFunction, Constant, DesignConstants, DesignElemRelation1, DesignElemRelation2, DesignLoadRelation1, DesignMatRelation1, DesignMatRelation2, DesignNodes, DesignPropRelation1, DesignPropRelation2, DesignResp1, DesignResp2, DesignVar, Element, LeastSquares, MatchedResponses, Maximum, Minimum, RootSumSquare, SafetyFactorMax, Sum, SumOfSquares, Table, UserData.

Example record

DesignResp2;35;AVGDISP;34;;;;;;;DesignResp1;2;32;32

Model containing this record

Reading the example gives id = 35, entryLabel = AVGDISP, equationId = 34.

DesignResp3

A response computed by a routine of the user, from design variables, constants and other responses.

Record format and fields

DesignResp3;id;entryLabel;groupName;kind;regionId;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

entryLabel

text

—

User label associated with the entry.

3

groupName

text

—

Text identifier selecting or naming the associated group.

4

kind

text

—

Selects the kind for DesignResp3.

5

regionId

integer

0

Identifier of the region on which the definition acts.

Keyed sections in arguments

Begin each section with its key, then write its fixed fields and any counted list.

Section DesignVar

Repeated group designVariables. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

designVarId

integer

—

Identifier of the design variable supplying the independent value.

Section DesignConstants

Repeated group constants. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

constantLabel

text

—

Text naming the constant.

Section DesignResp1

Repeated group responses. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

responseId

integer

—

Identifier selecting the response record or set.

Section DesignNodes

Repeated group nodeComponents. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

nodeId

integer

—

Identifier of the grid point addressed by this record.

2

nodeComponent

integer

—

Number of the degree of freedom at the associated point.

Section DesignPropRelation1

Repeated group propRelations. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

propRelationId

integer

—

Identifier selecting the property relation record or set.

Section DesignElemRelation1

Repeated group elemRelations. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

elemRelationId

integer

—

Identifier selecting the element relation record or set.

Section DesignMatRelation1

Repeated group matRelations. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

matRelationId

integer

—

Identifier selecting the material relation record or set.

Section DesignPropRelation2

Repeated group propRelations2. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

propRelation2Id

integer

—

Identifier selecting the property relation 2 record or set.

Section DesignElemRelation2

Repeated group elemRelations2. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

elemRelation2Id

integer

—

Identifier selecting the element relation 2 record or set.

Section DesignMatRelation2

Repeated group matRelations2. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

matRelation2Id

integer

—

Identifier selecting the material relation 2 record or set.

Section DesignResp2

Repeated group combinedResponses. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

combinedResponseId

integer

—

Identifier selecting the combined response record or set.

Section DesignLoadRelation1

Repeated group loadRelations. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

loadRelationId

integer

—

Identifier selecting the load relation record or set.

Section UserData

Repeated group userData. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

userText

text

—

Free-form character data carried with the design entry. Written as one text field.

Accepted words: Constant, DesignConstants, DesignElemRelation1, DesignElemRelation2, DesignLoadRelation1, DesignMatRelation1, DesignMatRelation2, DesignNodes, DesignPropRelation1, DesignPropRelation2, DesignResp1, DesignResp2, DesignVar, Element, Table, UserData.

Example record

DesignResp3;33;BUCKMRG;PANEL;BUCK;;DesignVar;1;1;DesignConstants;3;EMOD;PLEN;PWID;DesignResp1;1;32;DesignNodes;1;10;1;DesignPropRelation1;1;11;UserData;1;simply supported edges along y

Model containing this record

Reading the example gives id = 33, entryLabel = BUCKMRG, groupName = PANEL, kind = BUCK.

DesignShapeBasis

Defines a shape basis vector as a linear combination of displacement-matrix columns from a previous analysis.

Record format and fields

DesignShapeBasis;designVarId;column1;scaleFactor1;column2;scaleFactor2;column3;scaleFactor3

Position

Field

Type

Default

Meaning and conventions

1

designVarId

integer

Required

Identifier of the design variable supplying the independent value.

2

column1

integer

—

Column identifier for contribution 1 of the displacement or shape basis.

3

scaleFactor1

real

1.0

Multiplier applied to the quantity specified by the entry. Entry 1.

4

column2

integer

—

Column identifier for contribution 2 of the displacement or shape basis.

5

scaleFactor2

real

1.0

Multiplier applied to the quantity specified by the entry. Entry 2.

6

column3

integer

—

Column identifier for contribution 3 of the displacement or shape basis.

7

scaleFactor3

real

1.0

Multiplier applied to the quantity specified by the entry. Entry 3.

Accepted words: Constant, Element, Table.

Example record

DesignShapeBasis;2;2;0.5;1;0.5

Model containing this record

Reading the example gives designVarId = 2, column1 = 2, scaleFactor1 = 0.5, column2 = 1.

DesignTopologyRegion

A region of a topology optimisation, the elements of one property whose density the optimisation designs.

Record format and fields

DesignTopologyRegion;id;entryLabel;propType;initialValue;lowerBound;designVarMoveLimit;penaltyPower;propId;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

entryLabel

text

—

User label associated with the entry.

3

propType

text

—

Selects the property type for DesignTopologyRegion.

4

initialValue

real

—

Starting value of the quantity before an update or iteration.

5

lowerBound

real

0.001

Lower limit expressed in the same units as the bounded quantity.

6

designVarMoveLimit

real

—

Limits the change allowed for this design variable in one optimization update.

7

penaltyPower

real

—

Exponent penalizing intermediate values in the design interpolation.

8

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

Keyed sections in lines

Begin each section with its key, then write its fixed fields and any counted list.

Section Symmetry

Position

Field

Type

Default

Meaning and conventions

1

frameId

integer

—

Coordinate system in which this entry is expressed.

2

mirrorPlane1

text

—

Plane of mirror symmetry applied to the design region, entry 1.

3

mirrorPlane2

text

—

Plane of mirror symmetry applied to the design region, entry 2.

4

mirrorPlane3

text

—

Plane of mirror symmetry applied to the design region, entry 3.

5

cyclicAxis

text

—

Axis around which the repeated sectors are arranged.

6

cyclicSegments

integer

—

Number of sectors in a full revolution.

Section Casting

Position

Field

Type

Default

Meaning and conventions

1

frameId

integer

—

Coordinate system in which this entry is expressed.

2

castDirection

text

—

Draw direction specified for the casting constraint.

3

dieCount

integer

—

Number of die entries.

4

alignment

text

—

Alignment restriction on the manufacturing or design direction.

Section Extrusion

Position

Field

Type

Default

Meaning and conventions

1

frameId

integer

—

Coordinate system in which this entry is expressed.

2

extrusionDirection

text

—

Direction along which the design cross-section is extruded.

3

alignment

text

—

Alignment restriction on the manufacturing or design direction.

Section Overhang

Position

Field

Type

Default

Meaning and conventions

1

frameId

integer

—

Coordinate system in which this entry is expressed.

2

overhangDirection

text

—

Build direction used to measure an overhang constraint.

Section MemberSize

Position

Field

Type

Default

Meaning and conventions

1

minMemberSize

real

—

Lower bound on the characteristic member dimension.

2

maxMemberSize

real

—

Upper bound on the characteristic member dimension.

Section Stress

Position

Field

Type

Default

Meaning and conventions

1

stressLimit

real

—

Maximum or limiting stress in model stress units.

Accepted words: Casting, Constant, Element, Extrusion, MemberSize, NegativeXDirection, NegativeYDirection, NegativeZDirection, No, Overhang, PlaneXy, PlaneYz, PlaneZx, Stress, Symmetry, Table, XDirection, YDirection, Yes, ZDirection.

Example record

DesignTopologyRegion;1;MIDDLE;ShellProp;0.5;0.001;;;1

Model containing this record

Reading the example gives id = 1, entryLabel = MIDDLE, propType = ShellProp, initialValue = 0.5.

DesignTopometryRegion

A design region of a topometry optimisation, in which the thickness or another property value of every element of one property is a design variable of its own.

Record format and fields

DesignTopometryRegion;id;kind;propId;fieldName;initialValue;lowerBound;upperBound;designVarMoveLimit;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

kind

text

—

Selects the kind for DesignTopometryRegion.

3

propId

integer

Required

Identifier of the property from which the element obtains its section or constitutive data.

4

fieldName

text

—

Name of the field addressed by this entry.

5

initialValue

real

—

Starting value of the quantity before an update or iteration.

6

lowerBound

real

—

Lower limit expressed in the same units as the bounded quantity.

7

upperBound

real

—

Upper limit expressed in the same units as the bounded quantity.

8

designVarMoveLimit

real

0.5

Limits the change allowed for this design variable in one optimization update.

Keyed sections in lines

Begin each section with its key, then write its fixed fields and any counted list.

Section DesignVarLink

Position

Field

Type

Default

Meaning and conventions

1

tableId

integer

—

Identifier of the tabulated function to evaluate.

2

constant0

real

—

Coefficient 0 in the DesignTopometryRegion relation for link.

3

coefficient1

real

—

Coefficient 1 in the DesignTopometryRegion relation for link.

Section DesignDiscreteValues

Position

Field

Type

Default

Meaning and conventions

1

discreteValuesId

integer

—

Identifier of the DesignDiscreteValues list of admissible values.

Section Stress

Position

Field

Type

Default

Meaning and conventions

1

stressLimit

real

—

Maximum or limiting stress in model stress units.

Section Symmetry

Position

Field

Type

Default

Meaning and conventions

1

frameId

integer

—

Coordinate system in which this entry is expressed.

2

mirrorPlane1

text

—

Plane of mirror symmetry applied to the design region, entry 1.

3

mirrorPlane2

text

—

Plane of mirror symmetry applied to the design region, entry 2.

4

mirrorPlane3

text

—

Plane of mirror symmetry applied to the design region, entry 3.

5

cyclicAxis

text

—

Axis around which the repeated sectors are arranged.

6

cyclicSegments

integer

—

Number of sectors in a full revolution.

7

firstSymmetryPropId

integer

—

Identifier selecting the first symmetry property record or set.

Section with an empty key

Repeated group symmetryProps. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

symmetryPropId

integer

—

Identifier selecting the symmetry property record or set.

Accepted words: Constant, DesignDiscreteValues, DesignVarLink, Element, PlaneXy, PlaneYz, PlaneZx, Stress, Symmetry, Table, XDirection, YDirection, ZDirection.

Example record

DesignTopometryRegion;2;ShellProp;2;thickness;2.;1.;4.

Model containing this record

Reading the example gives id = 2, kind = ShellProp, propId = 2, fieldName = thickness.

DesignVar

Defines a design variable by its label, starting value and bounds. Design relations use its ID to vary model properties.

Record format and fields

DesignVar;id;entryLabel;initialValue;lowerBound;upperBound;designVarMoveLimit;discreteValuesId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier referenced by design relations and responses.

2

entryLabel

text

—

Name used to identify the variable in an optimization study.

3

initialValue

real

Required

Starting design coordinate. Use the same units for its bounds and discrete values.

4

lowerBound

real

—

Lower limit expressed in the same units as the bounded quantity.

5

upperBound

real

—

Upper limit expressed in the same units as the bounded quantity.

6

designVarMoveLimit

real

—

Limits the change allowed for this design variable in one optimization update.

7

discreteValuesId

integer

0

Identifier of the DesignDiscreteValues list of admissible values.

Accepted words: Constant, Element, Table.

Example record

DesignVar;1;FAC1;1.;0.5;2.;;50

Model containing this record

Reading the example gives id = 1, entryLabel = FAC1, initialValue = 1., lowerBound = 0.5.