Solution controls

All card families and alphabetical index

Read field positions from left to right within each table. A dash means the layout supplies no fixed default. Use a consistent system of units for dimensional quantities.

ArcLengthParams

The arc-length method of a nonlinear static analysis.

Record format and fields

ArcLengthParams;id;constraintKind;minArcLengthRatio;maxArcLengthRatio;scaleFactor;designIteration;maxIncrements

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

constraintKind

text

Crisfield

Selects the constraint kind for ArcLengthParams.

3

minArcLengthRatio

real

0.25

Relative measure of minimum arc length.

4

maxArcLengthRatio

real

4.0

Relative measure of maximum arc length.

5

scaleFactor

real

0.0

Multiplier applied to the quantity specified by the entry.

6

designIteration

integer

12

The iterations wanted for convergence.

7

maxIncrements

integer

20

The largest number of controlled increments of a subcase.

Accepted words: Crisfield, ModifiedRiks, Riks.

Example record

ArcLengthParams;10;Crisfield;0.25;4.;;6;40

Model containing this record

Reading the example gives id = 10, constraintKind = Crisfield, minArcLengthRatio = 0.25, maxArcLengthRatio = 4..

CampbellDiagram

The parameters of the generation of a Campbell diagram and of the tracking of the modes along it.

Record format and fields

CampbellDiagram;id;varyingParameter;discreteValuesId;speedUnit;modeTrackingMethod;correlationThreshold;trackingSwitch;trackedModeCount;printCorrelation

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

varyingParameter

text

—

Identifies the independent quantity varied during the sweep.

3

discreteValuesId

integer

Required

Identifier of the DesignDiscreteValues list of admissible values.

4

speedUnit

text

—

Unit used to express the specified speed.

5

modeTrackingMethod

integer

0

Selects the mode tracking method for CampbellDiagram.

6

correlationThreshold

real

0.7

Minimum correlation used when accepting or matching contributions.

7

trackingSwitch

integer

0

Controls tracking of the selected response through successive points.

8

trackedModeCount

integer

—

Number of tracked mode entries.

9

printCorrelation

integer

0

Controls printing of correlation results.

Accepted words: Constant, Element, Frequency, RevolutionsPerMinute, Speed, Table.

Example record

CampbellDiagram;15;Speed;16;RevolutionsPerMinute;1;0.7;1;4;0

Model containing this record

Reading the example gives id = 15, varyingParameter = Speed, discreteValuesId = 16, speedUnit = RevolutionsPerMinute.

CosimulationArea

The coupled area through which the solver exchanges data with a co-simulation partner.

Record format and fields

Forms: points, volume, surface.

CosimulationArea: points

Form points, when kind is Point.

CosimulationArea;id;kind;<nodes>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

kind

text

Surface

Selects the kind for CosimulationArea.

Repeated group nodes. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

nodeIds

any

—

Grid point identifiers defining the selected region.

CosimulationArea: volume

Form volume, when kind is Volume.

CosimulationArea;id;kind;<elements>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

kind

text

Surface

Selects the kind for CosimulationArea.

Repeated group elements. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

elemIds

any

—

Element identifiers defining the selected model region.

CosimulationArea: surface

Form surface, for every other record.

CosimulationArea;id;kind;<faces>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

kind

text

Surface

Selects the kind for CosimulationArea.

Repeated group faces. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

elemIds

integer

—

Element identifiers defining the selected model region.

2

faceIds

integer

—

Identifiers of the selected element faces.

Note: a list of IDs may hold THRU between two IDs (a range).

Accepted words: By, Constant, Element, Point, Surface, Table, Through, Volume.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • faceIds — FaceID must be between 1 and 6.

Example record

CosimulationArea;31;Surface;1;6;2;6;3;6;4;6

Model containing this record

CosimulationInputs

The physical quantities of input that the solver receives from the co-simulation partner.

Record format and fields

CosimulationInputs;id;quantity1;quantity2

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

quantity1

text

Force

Physical quantity 1 exchanged across the co-simulation interface.

3

quantity2

text

—

Physical quantity 2 exchanged across the co-simulation interface.

Accepted words: Constant, Element, Force, Table, Temperature.

Example record

CosimulationInputs;41;Force

Model containing this record

Reading the example gives id = 41, quantity1 = Force.

CosimulationOutputs

The physical quantities of output that the solver provides to the co-simulation partner.

Record format and fields

CosimulationOutputs;id;quantity1;quantity2;quantity3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

quantity1

text

—

Physical quantity 1 exchanged across the co-simulation interface.

3

quantity2

text

—

Physical quantity 2 exchanged across the co-simulation interface.

4

quantity3

text

—

Physical quantity 3 exchanged across the co-simulation interface.

Accepted words: Acceleration, Constant, Displacement, Element, Table, Velocity.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • quantity3 — the card has at most three quantities.

  • quantities — a quantity is given twice.

Example record

CosimulationOutputs;51;Displacement;Velocity

Model containing this record

Reading the example gives id = 51, quantity1 = Displacement, quantity2 = Velocity.

CosimulationSelection

The co-simulation services an analysis uses, listed by the number of their CosimulationService.

Record format and fields

CosimulationSelection;id;serviceId1;serviceId2;serviceId3

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

serviceId1

integer

—

Identifier selecting the service record or set.

3

serviceId2

integer

—

Identifier selecting the service record or set.

4

serviceId3

integer

—

Identifier selecting the service record or set.

Accepted words: Constant, Element, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • serviceId3 — the card has at most three services.

Example record

CosimulationSelection;21;61

Model containing this record

Reading the example gives id = 21, serviceId1 = 61.

CosimulationService

A co-simulation service, with the coupled areas and the physical quantities it exchanges.

Record format and fields

CosimulationService;id;serviceName;followerForces;inputAreaId;inputId;outputAreaId;outputId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

serviceName

text

—

Text naming the service.

3

followerForces

text

NoFollower

Controls whether applied forces follow the changing geometry.

4

inputAreaId

integer

—

Identifier selecting the input area record or set.

5

inputId

integer

—

Identifier selecting the input record or set.

6

outputAreaId

integer

—

Identifier selecting the output area record or set.

7

outputId

integer

—

Identifier selecting the output record or set.

Accepted words: Constant, Element, Follower, NoFollower, Table.

Example record

CosimulationService;61;scFLOW;Follower;31;41;31;51

Model containing this record

Reading the example gives id = 61, serviceName = scFLOW, followerForces = Follower, inputAreaId = 31.

CrossSpectrumPair

Pairs two response quantities for cross-power spectral density or cross-correlation recovery.

Record format and fields

CrossSpectrumPair;id;responseKind1;targetId1;component1;responseKind2;targetId2;component2;curveId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

responseKind1

text

same as responseKind2

Selects the response kind 1 for CrossSpectrumPair.

3

targetId1

integer

0

Identifier selecting the target record or set.

4

component1

integer

0

Degree of freedom or response component addressed by this term. Entry 1.

5

responseKind2

text

same as responseKind1

Selects the response kind 2 for CrossSpectrumPair.

6

targetId2

integer

0

Identifier selecting the target record or set.

7

component2

integer

0

Degree of freedom or response component addressed by this term. Entry 2.

8

curveId

integer

0

Identifier selecting the curve record or set.

Accepted words: Acceleration, AppliedLoad, ConstraintForce, Displacement, Force, MultiPointConstraintForce, Pressure, Strain, Stress, Velocity.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the ID must be a positive integer.

Example record

CrossSpectrumPair;95;Displacement;15;3;Displacement;5;3;1

Model containing this record

Reading the example gives id = 95, responseKind1 = Displacement, targetId1 = 15, component1 = 3.

CyclicSymmetry

The parameters of a cyclic symmetry analysis.

Record format and fields

CyclicSymmetry;segmentCount;symmetryKind

Position

Field

Type

Default

Meaning and conventions

1

segmentCount

integer

—

Number of segment entries.

2

symmetryKind

text

—

Selects the symmetry kind for CyclicSymmetry.

Accepted words: Axisymmetric, Constant, Dihedral, Element, Rotational, Table.

Example record

CyclicSymmetry;6;Rotational

Model containing this record

Reading the example gives segmentCount = 6, symmetryKind = Rotational.

DeactivatedElems

The elements that do not take part in the analysis, or in one physics pass of a coupled analysis.

Record format and fields

DeactivatedElems;id;elemSetId

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

elemSetId

integer

Required

Identifier selecting the element set record or set.

Accepted words: Constant, Element, Table.

Example record

DeactivatedElems;7;8

Model containing this record

Reading the example gives id = 7, elemSetId = 8.

EchoOffMarker

Marks the point of the Bulk Data from which the printed echo of the input file is deactivated.

Record format and fields

EchoOffMarker

This part of the record has no fixed fields.

Example record

EchoOffMarker

Model containing this record

EchoOnMarker

Marks the point of the Bulk Data from which the printed echo of the input file is activated.

Record format and fields

EchoOnMarker

This part of the record has no fixed fields.

Example record

EchoOnMarker

Model containing this record

FatigueDefinition

The elements of a fatigue analysis and the fatigue properties each has, and how much of the result is kept (the top percentage of the entities, the number of hot spots).

Record format and fields

FatigueDefinition;id;topStressCount;fatiguePropIds;topDamageCount;maxEntities;maxOutputEntities;hotSpotCount;hotSpotGate;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

topStressCount

real

—

Number of top stress entries.

3

fatiguePropIds

integer

0

Identifiers of the fatigue properties included in the definition.

4

topDamageCount

real

—

Number of top damage entries.

5

maxEntities

integer

—

The number of entities to report: positive by damage, negative by stress range.

6

maxOutputEntities

integer

100

Maximum number of model entities included in the output.

7

hotSpotCount

integer

—

Number of hot spot entries.

8

hotSpotGate

integer

0

The layers of elements kept around a hot spot.

Keyed sections in lines

Begin each section with its key, then write its fixed fields and any counted list.

Section ElemSet

Repeated group elemSets. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

elemSetId

integer

—

Identifier selecting the element set record or set.

2

fatiguePropId

integer

—

Identifier selecting the fatigue property record or set.

Section SpotWeld

Repeated group spotWelds. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

elemSetId

integer

—

Identifier selecting the element set record or set.

2

fatiguePropId

integer

—

Identifier selecting the fatigue property record or set.

Section SeamWeld

Repeated group seamWelds. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

elemSetId

integer

—

Identifier selecting the element set record or set.

2

fatiguePropId

integer

—

Identifier selecting the fatigue property record or set.

3

nodeSetId

integer

—

Identifier of the set supplying the grid points.

4

weldType

text

—

Selects the weld type for seamWelds.

5

weldLocation

text

—

Position on the weld at which the requested quantity is evaluated.

Section ExcludedElemSet

Repeated group excludedElemSets. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

excludedElemSetId

integer

—

Identifier selecting the excluded element set record or set.

Accepted words: Constant, Edge, ElemSet, Element, ExcludedElemSet, FilletWeld, Generic, LaserWeld, OverlapWeld, RootWeld, SeamWeld, SpotWeld, Table, ThroatThickness, ToeWeld.

Example record

FatigueDefinition;1;;;;;;;;ElemSet;1;71;;ExcludedElemSet;1;72

Model containing this record

Reading the example gives id = 1.

FatigueEvent

Groups fatigue loading histories that act at the same time in a fatigue assessment.

Record format and fields

FatigueEvent;id;<fatigueLoads>;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group fatigueLoads. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

fatigueLoadId

integer

—

Identifier selecting the fatigue load record or set.

Keyed sections in lines

Begin each section with its key, then write its fixed fields and any counted list.

Section Name

Position

Field

Type

Default

Meaning and conventions

1

eventName

text

—

Text naming the event. Written as one text field.

Accepted words: Constant, Element, FatigueLoad, Name, Table.

Example record

FatigueEvent;21;2;201;202;Name;combined

Model containing this record

Reading the example gives id = 21.

FatigueLoad

Describes a load history or spectrum contributing to a fatigue event.

Record format and fields

FatigueLoad;id;tableId;loadCaseId;referenceLoadMagnitude;scaleFactor;offset;historyKind;channel;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

tableId

integer

0

Identifier of the tabulated function to evaluate.

3

loadCaseId

integer

Required

Identifier addressing random set data.

4

referenceLoadMagnitude

real

1.0

Reference load amplitude used for scaling the results.

5

scaleFactor

real

1.0

Multiplier applied to the quantity specified by the entry.

6

offset

real

—

Shift from the reference location or value in the convention of this entry.

7

historyKind

text

—

Selects the history kind for FatigueLoad.

8

channel

integer

0

Channel of the external data file supplying the sampled history.

Keyed sections in lines

Begin each section with its key, then write its fixed fields and any counted list.

Section Units

Position

Field

Type

Default

Meaning and conventions

1

equivalentUnits

real

1.0

Conversion factor between the unit conventions used by the two data sets.

2

equivalentUnitName

text

—

Text naming the equivalent unit. Written as one text field.

Section DeterministicLoad

Repeated group bands. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

bandFrequency

real

—

Band frequency (inverse time).

2

bandAmplitude

real

—

Amplitude associated with the selected frequency band.

3

bandWidth

real

—

Band width (length).

Section SweepLoad

Position

Field

Type

Default

Meaning and conventions

1

sweepStartFrequency

real

—

Sweep start frequency (inverse time).

2

sweepStartAmplitude

real

—

Amplitude at the start of the requested sweep.

3

sweepEndFrequency

real

—

Sweep end frequency (inverse time).

4

sweepEndAmplitude

real

—

Amplitude at the end of the requested sweep.

5

sweepKind

text

FreqInHertz

Selects the sweep kind for sweep.

6

sweepNumber

integer

50

Identifier or index of the sweep being specified.

7

sweepRate

real

—

Rate at which the sweep progresses through its range.

8

sweepCount

integer

—

Number of sweep entries.

9

transferFunctionQuantity

text

Acceleration

Response quantity used in the transfer function calculation.

10

loadQuantity

text

Acceleration

Physical load quantity to use in the evaluation.

Accepted words: Acceleration, Constant, ConstantLoad, DataAcquisitionFile, Decibel, DeterministicLoad, Displacement, Element, Force, FreqInHertz, LoadHistoryFile, NarrowBand, Octave, SineLoad, SpectralDensityLoad, Static, SweepLoad, Table, Units, Velocity.

Example record

FatigueLoad;201;101;1;100.;1.;0.

Model containing this record

Reading the example gives id = 201, tableId = 101, loadCaseId = 1, referenceLoadMagnitude = 100..

FatigueParams

The parameters of a fatigue analysis (type, combination of the stresses, mean stress correction, location of the results, and the lines for rainflow counting, certainty of survival, factor of safety, spot welds, seam welds, multiaxial assessment, nodal averaging, and vibration fatigue).

Record format and fields

FatigueParams;id;lifeModel;factor;threadCount;logLevel;layer;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

lifeModel

text

StressLifeMethod

Selects the fatigue life relation.

3

factor

real

1.0

Multiplier on the associated contribution.

4

threadCount

integer

—

Number of thread entries.

5

logLevel

integer

0

Amount of diagnostic information requested.

6

layer

integer

0

Layer number selected for stress recovery or evaluation.

Keyed sections in lines

Begin each section with its key, then write its fixed fields and any counted list.

Section Stress

Position

Field

Type

Default

Meaning and conventions

1

combination

text

AbsoluteMaxPrincipal

Rule for combining the contributions included in the analysis.

2

meanStressCorrection

text

None

Selects the correction applied to fatigue life for the mean stress.

3

plasticityCorrection

text

Neuber

Selects the correction accounting for local plastic response in fatigue.

4

resultLocation

text

NodalAveraging

Entity or position at which the result is recovered.

5

curveInterpolation

integer

0

Specifies how intermediate values on the curve are recovered.

6

stressRecovery

text

—

Method or selection used to obtain stress results.

7

surfaceResolved

text

No

Selects quantities resolved into components on the specified surface.

8

planeAngleCount

integer

36

Number of plane angle entries.

Section Strain

Position

Field

Type

Default

Meaning and conventions

1

combination

text

AbsoluteMaxPrincipal

Rule for combining the contributions included in the analysis.

2

meanStressCorrection

text

None

Selects the correction applied to fatigue life for the mean stress.

3

plasticityCorrection

text

Neuber

Selects the correction accounting for local plastic response in fatigue.

4

resultLocation

text

NodalAveraging

Entity or position at which the result is recovered.

5

curveInterpolation

integer

0

Specifies how intermediate values on the curve are recovered.

6

stressRecovery

text

—

Method or selection used to obtain stress results.

7

surfaceResolved

text

No

Selects quantities resolved into components on the specified surface.

8

planeAngleCount

integer

36

Number of plane angle entries.

Section RainflowCounting

Position

Field

Type

Default

Meaning and conventions

1

responseKind

text

—

Selects the response kind for rainflow.

Section CertaintyOfSurvival

Position

Field

Type

Default

Meaning and conventions

1

survivalCertainty

real

50.0

Survival level associated with the fatigue calculation.

Section FactorOfSafety

Position

Field

Type

Default

Meaning and conventions

1

safetyFactorOption

text

LifeResult

Selects the safety factor option for safetyFactor.

2

targetLife

real

—

Design life used as the reference for fatigue assessment.

3

backCalculationAccuracy

real

1.0

Accuracy requested when the fatigue calculation works back to a load or life value.

4

maxSafetyFactor

real

5.0

Multiplier for maximum safety.

5

minSafetyFactor

real

0.2

Multiplier for minimum safety.

Section SpotWeld

Position

Field

Type

Default

Meaning and conventions

1

combination

text

StandardCorrection

Rule for combining the contributions included in the analysis.

2

meanStressCorrection

text

None

Selects the correction applied to fatigue life for the mean stress.

3

planeAngleCount

integer

18

Number of plane angle entries.

4

spotWeldLocation

integer

0

Location of stress evaluation for the spot weld.

5

middleSheets

integer

1

Intermediate sheets considered in the welded connection.

6

torsion

integer

0

Selection or value for the torsional component of the response.

Section SeamWeld

Position

Field

Type

Default

Meaning and conventions

1

combination

text

AbsoluteMaxPrincipal

Rule for combining the contributions included in the analysis.

2

meanStressCorrection

text

None

Selects the correction applied to fatigue life for the mean stress.

3

thicknessCorrection

integer

0

Selects the correction to the fatigue calculation for material thickness.

4

seamWeldLocation

text

Node

Location along the seam at which weld response is evaluated.

5

seamWeldResult

text

—

Quantity requested for the seam weld.

Section Multiaxial

Position

Field

Type

Default

Meaning and conventions

1

multiaxialMethod

text

—

Selects the multiaxial method for multiaxial.

2

nonProportionalityLower

number

—

Lower bound for classifying nonproportional loading in the fatigue evaluation.

3

nonProportionalityUpper

number

—

Upper bound for classifying nonproportional loading in the fatigue evaluation.

4

biaxialityLower

number

—

Lower bound for the fatigue model’s biaxiality classification.

5

biaxialityMiddle

number

—

Intermediate boundary for classifying biaxial stress states.

6

biaxialityUpper

number

—

Upper bound for the fatigue model’s biaxiality classification.

7

zeroThreshold

number

—

Magnitude below which the value is treated as zero.

8

gateThreshold

number

—

Threshold used to retain or discard small signal variations.

Section NodeAverage

Position

Field

Type

Default

Meaning and conventions

1

averagingMethod

text

Topology

Selects the averaging method for averaging.

2

output

integer

0

Controls the information recovered or written for this entry.

3

surfaceNormal

text

RadiusVector

Direction or convention used for the outward normal of the surface.

Section VibrationFatigue

Position

Field

Type

Default

Meaning and conventions

1

spectrumMethod

text

DirlikMethod

Selects the spectrum method for vibration.

2

maxStressRms

real

10.0

Upper bound on the root-mean-square stress.

3

clipLevel

real

same as maxStressRms

Signal level at which the supplied history is clipped.

4

maxPeak

real

—

Peak-value limit used in the fatigue evaluation.

5

stressBins

integer

—

Discretization used to group stress ranges or levels.

6

maxFrequencyFraction

real

99.9

Upper frequency fraction retained in the evaluation.

7

binLifeMethod

text

Average

Selects the bin life method for vibration.

Accepted words: AbsoluteMaxPrincipal, Automatic, Average, Axis1, Axis2, Axis3, BilinearFit, Center, CertaintyOfSurvival, ComponentXStress, ComponentXyStress, ComponentYStress, ComponentYzStress, ComponentZStress, ComponentZxStress, Constant, CornerPoints, CriticalPlane, CubicFit, DirlikMethod, Element, Elements, FactorOfSafety, FkmGuideline, GeometryOption, GerberCorrection, GerberTensionCorrection, GoodmanCorrection, GoodmanTensionCorrection, InterpolationMethod, LifeResult, Load, MetallicHandbookData, MidSurface, MorrowCorrection, Multiaxial, NarrowBand, Neuber, No, NodalAveraging, Node, NodeAverage, None, RadiusVector, RainflowCounting, ReversedAxis1, ReversedAxis2, ReversedAxis3, ReversedRadiusVector, SeamWeld, SignedMaxShear, SignedVonMises, Simple, SinesCorrection, SmithWatsonTopper, SpotWeld, Standard, StandardCorrection, SteinbergModel, Strain, StrainGageFit, StrainLifeMethod, Stress, StressLifeMethod, Table, Topology, UniversalSlopes, UpperKind, VibrationFatigue, WalkerCorrection, Yes.

Example record

FatigueParams;10;StressLifeMethod;;;;;Stress;AbsoluteMaxPrincipal;GoodmanCorrection;;Elements;;;;;CertaintyOfSurvival;90.

Model containing this record

Reading the example gives id = 10, lifeModel = StressLifeMethod.

FatigueProp

Assigns fatigue properties to elements selected by a FatigueDefinition.

Record format and fields

FatigueProp;id;surfaceFinish;finishFactor;fatigueNotchFactor;scaleFactor;offset;treatmentFactor;diameter;thickness1;thickness2;spotWeldFlag

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

surfaceFinish

text

—

Surface-condition descriptor used by the fatigue model.

3

finishFactor

real

—

Multiplier for finish.

4

fatigueNotchFactor

real

1.0

Multiplier for fatigue notch.

5

scaleFactor

real

1.0

Multiplier applied to the quantity specified by the entry.

6

offset

real

0.0

Shift from the reference location or value in the convention of this entry.

7

treatmentFactor

real

1.0

Multiplier for treatment.

8

diameter

real

—

Diameter (length).

9

thickness1

real

—

Through-thickness dimension, in model length units. Entry 1.

10

thickness2

real

—

Through-thickness dimension, in model length units. Entry 2.

11

spotWeldFlag

integer

0

Selects the spot weld flag for FatigueProp.

Accepted words: Cast, Constant, Element, GroundSurface, MachinedSurface, None, PolishedSurface, PoorSurface, RolledSurface, RoughnessFactor, SurfaceFinishFactor, Table.

Example record

FatigueProp;51;MachinedSurface;;1.1

Model containing this record

Reading the example gives id = 51, surfaceFinish = MachinedSurface, fatigueNotchFactor = 1.1.

FatigueSequence

The sequence of loading events of a fatigue analysis (pseudo-static, modal, modal transient or random vibration), each with the number of times it is repeated, and possibly other sequences.

Record format and fields

FatigueSequence;id;eventOutput;combinationMethod;timeUnit;referenceLoadMagnitude;<sequenceItems>;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

eventOutput

integer

0

1 asks the fatigue output of each event on its own.

3

combinationMethod

integer

0

Selects the combination method for FatigueSequence.

4

timeUnit

text

TimeInSeconds

Unit used for the time axis.

5

referenceLoadMagnitude

real

1.0

Reference load amplitude used for scaling the results.

Repeated group sequenceItems. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

eventOrSequenceId

integer

—

Identifier selecting the event or sequence record or set.

2

repeats

real

—

Number of times the specified event or history occurs.

Keyed sections in lines

Begin each section with its key, then write its fixed fields and any counted list.

Section Units

Position

Field

Type

Default

Meaning and conventions

1

equivalentUnits

real

1.0

Conversion factor between the unit conventions used by the two data sets.

2

equivalentUnitName

text

—

Text naming the equivalent unit. Written as one text field.

Accepted words: Constant, Element, Table, TimeInDays, TimeInHours, TimeInMinutes, TimeInMonths, TimeInSeconds, TimeInWeeks, TimeInYears, Units.

Example record

FatigueSequence;10;1;0;;;2;21;1.E+3;22;5.E+3;Units;1.;blocks

Model containing this record

Reading the example gives id = 10, eventOutput = 1, combinationMethod = 0.

FluidStructureControl

Specifies the analysis mode of a coupled fluid–structure service.

Record format and fields

FluidStructureControl;serviceName;couplingKind;frequency;interfaceKind

Position

Field

Type

Default

Meaning and conventions

1

serviceName

text

—

Text naming the service.

2

couplingKind

text

ExplicitSolver

Selects the coupling kind for FluidStructureControl.

3

frequency

integer

1

Number of coupling updates per time step. This is an integer update rate.

4

interfaceKind

text

DesignVariables

Selects the interface kind for FluidStructureControl.

Accepted words: Constant, DesignVariables, Displacement, Element, ExplicitSolver, ImplicitSolver, Table.

Example record

FluidStructureControl;fsisvc;ImplicitSolver;2;Displacement

Model containing this record

Reading the example gives serviceName = fsisvc, couplingKind = ImplicitSolver, frequency = 2, interfaceKind = Displacement.

InitialPlasticStrain

Initial equivalent plastic strain for a range of elements, integration points and layers.

Record format and fields

InitialPlasticStrain;firstElemId;lastElemId;firstPoint;lastPoint;firstLayer;lastLayer;strain

Position

Field

Type

Default

Meaning and conventions

1

firstElemId

integer

—

Identifier selecting the first element record or set.

2

lastElemId

integer

—

Identifier selecting the last element record or set.

3

firstPoint

integer

—

First recovery or evaluation point included in the range.

4

lastPoint

integer

—

Last recovery or evaluation point included in the range.

5

firstLayer

integer

—

First layer in the requested through-thickness range.

6

lastLayer

integer

—

Last layer in the requested through-thickness range.

7

strain

real

0.0

Strain (dimensionless).

Accepted words: Constant, Element, Table.

Example record

InitialPlasticStrain;201;202;1;8;;;0.002

Model containing this record

Reading the example gives firstElemId = 201, lastElemId = 202, firstPoint = 1, lastPoint = 8.

InitialStress

An initial stress, for the elements, integration points and layers of a range.

Record format and fields

InitialStress;firstElemId;lastElemId;firstPoint;lastPoint;firstLayer;lastLayer;stress1;stress2;stress3;stress4;stress5;stress6;stress7;coordinate;frameId

Position

Field

Type

Default

Meaning and conventions

1

firstElemId

integer

—

Identifier selecting the first element record or set.

2

lastElemId

integer

—

Identifier selecting the last element record or set.

3

firstPoint

integer

—

First recovery or evaluation point included in the range.

4

lastPoint

integer

—

Last recovery or evaluation point included in the range.

5

firstLayer

integer

—

First layer in the requested through-thickness range.

6

lastLayer

integer

—

Last layer in the requested through-thickness range.

7

stress1

real

0.0

Stress 1 (force per area).

8

stress2

real

0.0

Stress 2 (force per area).

9

stress3

real

0.0

Stress 3 (force per area).

10

stress4

real

0.0

Stress 4 (force per area).

11

stress5

real

0.0

Stress 5 (force per area).

12

stress6

real

0.0

Stress 6 (force per area).

13

stress7

real

0.0

Stress 7 (force per area).

14

coordinate

text

—

Coordinate of the specified point in the selected frame.

15

frameId

integer

—

Coordinate system in which this entry is expressed.

Accepted words: Constant, Coordinates, Element, Table.

Example record

InitialStress;101;102;1;8;;;20.;0.;0.;0.;0.;0.

Model containing this record

Reading the example gives firstElemId = 101, lastElemId = 102, firstPoint = 1, lastPoint = 8.

IterativeSolverOptions

Iterative solver options.

Record format and fields

IterativeSolverOptions;id;<options>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group options. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

option

text

—

Selects how the current entry or group is interpreted.

Accepted words: BlockIncompleteCholesky, BlockIncompleteCholeskyComplex, CacheAwareIncomplete, Constant, Element, EnergyNormCriterion, EnergyNormCriterionExtended, IncompleteCholesky, IncompleteCholeskyScaled, Jacobi, JacobiScaled, No, ResidualRatioCriterion, ResidualRatioCriterionExtended, RowIncompleteCholesky, RowIncompleteCholeskySymmetric, Table, User, Yes.

Accepted parameter names: ConvergenceCriteria, EstimateResourcesOnly, IterationMessages, IterationTolerance, MaxIterationSteps, PreconditionerExtractionLevel, PreconditionerKind, PreconditionerPadding.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • options — an option name is a letter followed by letters, digits and underscores (at most 16).

Example record

IterativeSolverOptions;50;PreconditionerKind=BlockIncompleteCholesky;IterationTolerance=1.0E-8;IterationMessages=Yes

Model containing this record

Reading the example gives id = 50.

ModeTracking

The mode tracking of a design optimization.

Record format and fields

ModeTracking;id;lowRange;highRange;trackingFilter

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

lowRange

integer

0

The lowest mode number of the search range.

3

highRange

integer

0

Upper end of the range admitted to the evaluation.

4

trackingFilter

real

0.9

The filtering parameter of the cross orthogonality check.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the ID must be a positive integer.

Example record

ModeTracking;100;1;6;0.8

Model containing this record

Reading the example gives id = 100, lowRange = 1, highRange = 6, trackingFilter = 0.8.

ModelParams

Parameters that affect the solution of the structural model.

Record format and fields

ModelParams;<parameters>

This part of the record has no fixed fields.

Repeated group parameters. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

any

—

Value assigned to the named parameter. Its interpretation depends on that name.

Accepted words: ElemOffsetZ, ElemOffsetsOnly, HarderShearPanel, LoadRecoveryOffsets, NoDampingOffsets, NoMassOffsets, NoOffsetDifference, NoTemperatureGradientOffsets, NoThermalOffsets.

Accepted parameter names: BeamLibraryShearFactor, OffsetDefinition, OffsetDisplacementLoad, ShearPanelFormulation.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • parameterNames — the card needs at least one parameter and its value.

Example record

ModelParams;HDF5;1

Model containing this record

ModuleResultFileParams

Records module-specific output settings that extend the model-level ResultFileParams definition.

Record format and fields

ModuleResultFileParams;moduleId;<parameters>

Position

Field

Type

Default

Meaning and conventions

1

moduleId

integer

Required

Identifier selecting the module record or set.

Repeated group parameters. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

any

—

Value assigned to the named parameter. Its interpretation depends on that name.

Accepted words: BloscCompression, CompressionLevel, CompressionMethod, GzipCompression, InputData, LoadConstraintTables, Lz4Compression, MatrixData, ModalMatrixOutput, No, NodeElementTables, None, Precision, RotationalDofs, RunInformation, SeparateModelFile, Yes.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • parameterNames — the card needs at least one parameter and its value.

Example record

ModuleResultFileParams;0;LoadConstraintTables;1

Model containing this record

Reading the example gives moduleId = 0.

NonlinearHarmonicSolverParams

Values for the parameters of the nonlinear frequency response analysis.

Record format and fields

NonlinearHarmonicSolverParams;<parameters>

This part of the record has no fixed fields.

Repeated group parameters. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

any

—

Value assigned to the named parameter. Its interpretation depends on that name.

Accepted words: Both, Constant, Element, Full, LdlDecomposition, LowerUpperDecomposition, No, Off, On, QrDecomposition, Table, Yes.

Accepted parameter names: ContinuationMethod, DecompositionMethod, ExtraSamplingPoints, InitialConditionOutput, LineSearchStepFactor, MaxFrequencyInterval, MaxNonConvergedFrequencies, MaxNonConvergedSteps, NonlinearHarmonicDiagnostic, NonlinearHarmonicReduction, NonlinearHarmonicTolerance, StepHalvingIterations.

Example record

NonlinearHarmonicSolverParams;ContinuationMethod;2;DecompositionMethod;QrDecomposition;StepHalvingIterations;8

Model containing this record

NonlinearStaticParams

The iteration strategy of a nonlinear static analysis.

Record format and fields

NonlinearStaticParams;id;incrementCount;timeStep;stiffnessMethod;stiffnessUpdateStep;maxIterations;convergenceFlags;intermediateOutput;epsilonU;epsilonP;epsilonW;maxDivergences;maxQuasiNewtonVectors;maxLineSearches;stressSubincrementFraction;lineSearchTolerance;maxBisections;maxRotationRatio;rotationTolerance;minIterations

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

incrementCount

integer

—

Number of increment entries.

3

timeStep

real

0.0

Time increment between successive states, in model time units.

4

stiffnessMethod

text

—

Selects the stiffness method for NonlinearStaticParams.

5

stiffnessUpdateStep

integer

—

Step interval or stage at which the tangent stiffness is updated.

6

maxIterations

integer

25

Maximum number of iterations permitted at this stage.

7

convergenceFlags

text

—

Selects the residual, displacement, work or other convergence checks to apply.

8

intermediateOutput

text

No

Controls output at intermediate increments or stations.

9

epsilonU

real

—

Tolerance on the displacement increment in the nonlinear convergence test.

10

epsilonP

real

—

Tolerance on the load or force residual in the nonlinear convergence test.

11

epsilonW

real

—

Tolerance on incremental work in the nonlinear convergence test.

12

maxDivergences

integer

3

Number of divergence events allowed before changing or rejecting the step.

13

maxQuasiNewtonVectors

integer

—

Limit on the vectors retained in a quasi-Newton update.

14

maxLineSearches

integer

—

Maximum line-search updates in an iteration.

15

stressSubincrementFraction

real

0.2

Fraction of the stress change allowed within a subincrement.

16

lineSearchTolerance

real

0.5

Permitted numerical deviation for line search.

17

maxBisections

integer

—

Maximum permitted subdivisions of an increment by bisection.

18

maxRotationRatio

real

20.0

Relative measure of maximum rotation.

19

rotationTolerance

real

20.0

Permitted numerical deviation for rotation.

20

minIterations

integer

—

Minimum number of iterations before the convergence decision.

Accepted words: All, Automatic, FullNewtonTangent, Iterative, No, PseudoFullNewtonTangent, Semi, Yes.

Example record

NonlinearStaticParams;30;5;;Automatic;;25;PW;No

Model containing this record

Reading the example gives id = 30, incrementCount = 5, stiffnessMethod = Automatic, maxIterations = 25.

NonlinearTimeSteps

The controls of a nonlinear transient analysis.

Record format and fields

NonlinearTimeSteps;id;stepCount;timeStep;outputInterval;method;stiffnessUpdateStep;maxIterations;convergenceFlags;epsilonU;epsilonP;epsilonW;maxDivergences;maxQuasiNewtonVectors;maxLineSearches;stressSubincrementFraction;maxBisections;adjustInterval;minStepsPerCycle;stepBounds;maxRotationRatio;displacementTolerance;rotationTolerance;minIterations

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

stepCount

integer

Required

Number of step entries.

3

timeStep

real

Required

Time increment between successive states, in model time units.

4

outputInterval

integer

1

Spacing between successive output requests.

5

method

text

—

Selects the method for NonlinearTimeSteps.

6

stiffnessUpdateStep

integer

—

Step interval or stage at which the tangent stiffness is updated.

7

maxIterations

integer

—

Maximum number of iterations permitted at this stage.

8

convergenceFlags

text

—

Selects the residual, displacement, work or other convergence checks to apply.

9

epsilonU

real

—

Tolerance on the displacement increment in the nonlinear convergence test.

10

epsilonP

real

—

Tolerance on the load or force residual in the nonlinear convergence test.

11

epsilonW

real

—

Tolerance on incremental work in the nonlinear convergence test.

12

maxDivergences

integer

2

Number of divergence events allowed before changing or rejecting the step.

13

maxQuasiNewtonVectors

integer

—

Limit on the vectors retained in a quasi-Newton update.

14

maxLineSearches

integer

—

Maximum line-search updates in an iteration.

15

stressSubincrementFraction

real

0.2

Fraction of the stress change allowed within a subincrement.

16

maxBisections

integer

—

Maximum permitted subdivisions of an increment by bisection.

17

adjustInterval

integer

5

Interval between checks at which the time-step controller may adjust the increment.

18

minStepsPerCycle

integer

—

Minimum number of increments used to resolve one oscillation cycle.

19

stepBounds

real

0.6

Limits imposed on the size of the step.

20

maxRotationRatio

real

32.0

Relative measure of maximum rotation.

21

displacementTolerance

real

0.1

Permitted numerical deviation for displacement.

22

rotationTolerance

real

20.0

Permitted numerical deviation for rotation.

23

minIterations

integer

—

Minimum number of iterations before the convergence decision.

Accepted words: Adaptive, Automatic, FullNewtonTangent, Iterative, PseudoFullNewtonTangent, Semi.

Example record

NonlinearTimeSteps;61;10;0.01;1;Adaptive;2;10;PW;0.01;0.001;1.E-6;2;10;2;0.02;5;5;;0.75;16.;0.1;20.

Model containing this record

Reading the example gives id = 61, stepCount = 10, timeStep = 0.01, outputInterval = 1.

ReferenceRotor

The reference rotor of the non-reference rotors of the residual structure, for a complex eigenvalue analysis.

Record format and fields

ReferenceRotor;id;referenceRotorId;<nonFollowingRotors>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

referenceRotorId

integer

Required

Identifier selecting the reference rotor record or set.

Repeated group nonFollowingRotors. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

nonFollowingRotorId

any

—

Identifier selecting the non following rotor record or set.

Accepted words: By, Constant, Element, Table, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • nonFollowingRotorIds — the card needs at least one non-reference rotor.

Example record

ReferenceRotor;100;10;20

Model containing this record

Reading the example gives id = 100, referenceRotorId = 10.

ResidualVectorDofs

Degrees of freedom where unit loads are applied to get the static solutions that the residual vector computation uses.

Record format and fields

ResidualVectorDofs;<dofs>

This part of the record has no fixed fields.

Repeated group dofs. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

node

integer

—

Grid point to which this entry applies.

2

components

integer

—

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations.

Accepted words: Through.

Example record

ResidualVectorDofs;15;3;5;3

Model containing this record

ResidualVectorDofs1

The degrees of freedom C of a list of points where unit loads are applied to get the static solutions that the residual vector computation uses.

Record format and fields

ResidualVectorDofs1;components;<nodes>

Position

Field

Type

Default

Meaning and conventions

1

components

integer

0

Degrees of freedom selected at the associated points. For structural grid points, digits 1–3 denote translations and 4–6 denote rotations.

Repeated group nodes. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

node

any

—

Grid point to which this entry applies.

Accepted words: Through.

Example record

ResidualVectorDofs1;12;5;10;15

Model containing this record

Reading the example gives components = 12.

ResultFileModules

Selects separate or appended results files for individual model modules.

Record format and fields

ResultFileModules;id;configuration;<modules>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

configuration

integer

0

Selects the model configuration used by this calculation.

Repeated group modules. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

moduleId

integer

—

Identifier selecting the module record or set.

2

userNameId

integer

—

Identifier selecting the user name record or set.

Accepted words: Constant, Element, Table.

Example record

ResultFileModules;17;0;0;100;1;101

Model containing this record

Reading the example gives id = 17, configuration = 0.

ResultFileParams

Stores named results-file settings such as precision, compression and output selection.

Record format and fields

Forms: numbered, plain.

ResultFileParams: numbered

Form numbered, when number is an integer.

ResultFileParams;number;<parameters>

Position

Field

Type

Default

Meaning and conventions

1

number

integer

—

Identification number for the selected entry or output stream.

Repeated group parameters. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

any

—

Value assigned to the named parameter. Its interpretation depends on that name.

ResultFileParams: plain

Form plain, for every other record.

ResultFileParams;<parameters>

This part of the record has no fixed fields.

Repeated group parameters. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

parameterName

text

—

Selects the setting to assign. Use the spelling from this card’s parameter list.

2

parameterValue

any

—

Value assigned to the named parameter. Its interpretation depends on that name.

Accepted words: BloscCompression, CompressionLevel, CompressionMethod, Constant, Element, GzipCompression, InputData, LoadConstraintTables, Lz4Compression, MatrixData, ModalMatrixOutput, No, NodeElementTables, None, Precision, RotationalDofs, RunInformation, SeparateModelFile, Table, Yes.

Accepted parameter names: CompressionLevel, CompressionMethod, InputData, LoadConstraintTables, MatrixData, ModalMatrixOutput, NodeElementTables, Precision, RotationalDofs, RunInformation, SeparateModelFile.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • parameterName — the number before the parameters must not be negative.

  • parameterName — the card needs at least one parameter and its value.

Example record

ResultFileParams;Precision;64;CompressionMethod;GzipCompression

Model containing this record

ResultMetadata

Attaches user-supplied descriptive metadata to analysis results.

Record format and fields

ResultMetadata;metadataName;<metadataLines>

Position

Field

Type

Default

Meaning and conventions

1

metadataName

text

—

Text naming the metadata. Written as one text field.

Repeated group metadataLines. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

metadataInfo

text

—

Descriptive information carried with the result metadata. Written as one text field.

Example record

ResultMetadata;plate_metadata;O_o_Reader test model of the solution control cards;units mm N t s and an aluminium plate 2 mm thick

Model containing this record

Reading the example gives metadataName = plate_metadata.

RotorAxisym

The elements, the properties or the grid points that make an axisymmetric rotor.

Record format and fields

RotorAxisym;id;listType;<nodes>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

listType

text

—

Selects the list type for RotorAxisym.

Repeated group nodes. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

nodeId

any

—

Identifier of the grid point addressed by this record.

Accepted words: By, Constant, Element, Elements, Node, Property, Table, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • nodeIds — the card needs at least one ID.

Example record

RotorAxisym;30;Node;5001;5002;5003;5004

Model containing this record

Reading the example gives id = 30, listType = Node.

RotorInitialBend

The initial deformation of a rotor, made of kinks and offsets, which the rotor takes on before it is pulled onto its bearing and analysed.

Record format and fields

RotorInitialBend;bendTableId;rotorId;loadId;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

bendTableId

integer

Required

Table supplying the variation of bend.

2

rotorId

integer

Required

Identifier selecting the rotor record or set.

3

loadId

integer

Required

Identifier selecting the load record or set.

Keyed sections in rows

Begin each section with its key, then write its fixed fields and any counted list.

Section UnbalanceFrame

Position

Field

Type

Default

Meaning and conventions

1

coordinate1

real

—

Coordinate of the specified point in the selected frame. Entry 1.

2

coordinate2

real

—

Coordinate of the specified point in the selected frame. Entry 2.

3

coordinate3

real

—

Coordinate of the specified point in the selected frame. Entry 3.

Section KinkDeformation

Repeated group kinks. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

station

real

—

Position along the member or sampled path.

2

angle

real

—

Angular position or orientation relative to the reference on this card.

3

phase

real

—

Phase of the harmonic quantity relative to the reference oscillation.

Section Offset

Repeated group offsets. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

station

real

—

Position along the member or sampled path.

2

offset

real

—

Shift from the reference location or value in the convention of this entry.

3

phase

real

—

Phase of the harmonic quantity relative to the reference oscillation.

Section BearingDeflectionProfile

Repeated group bearings. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

rotorNode

integer

—

Grid point belonging to the rotating side.

2

statorNode

integer

—

Grid point belonging to the stationary side.

Accepted words: BearingDeflectionProfile, Constant, Element, KinkDeformation, Offset, Table, UnbalanceFrame.

Example record

RotorInitialBend;700;10;99;UnbalanceFrame;0.;1.;0.;KinkDeformation;1;200.;0.05;0.;BearingDeflectionProfile;2;1001;3001;1005;3005

Model containing this record

Reading the example gives bendTableId = 700, rotorId = 10, loadId = 99.

RotorLineNodes

The grids that make the line model of a rotor.

Record format and fields

RotorLineNodes;id;<nodes>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

Repeated group nodes. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

nodeId

any

—

Identifier of the grid point addressed by this record.

Accepted words: By, Through.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the rotor ID must be a positive integer.

  • nodeIds — the card needs at least one grid.

  • nodeIds — the grids must be positive integers.

  • increment — a single grid has no increment.

Example record

RotorLineNodes;1;101;Through;105

Model containing this record

Reading the example gives id = 1.

RotorModel3D

The 3D model of a rotor, as the elements or the properties that make it and the grid points of its axis of rotation.

Record format and fields

RotorModel3D;id;frame;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

frame

text

FixedEnd

Specifies the coordinate frame in which values are resolved.

Keyed sections in lists

Begin each section with its key, then write its fixed fields and any counted list.

Section Elements

Repeated group elements. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

elemId

any

—

Identifier of the element addressed by this record.

Section Property

Repeated group properties. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

propId

any

—

Identifier of the property from which the element obtains its section or constitutive data.

Section Axis

Repeated group axisNodes. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

axisNode

integer

—

Grid point used to define the axis of the specified rotor or rotation.

Accepted words: Axis, By, Constant, Element, Elements, FixedEnd, Property, Rotation, Table, Through.

Example record

RotorModel3D;10;FixedEnd;Elements;5;1001;1002;1003;1004;1010;Axis;5;1001;1002;1003;1004;1005

Model containing this record

Reading the example gives id = 10, frame = FixedEnd.

RotorRelativeSpin

The spin rate of a rotor relative to the others, for a complex eigenvalue, a frequency response or a static analysis, and the damping of the rotor.

Record format and fields

RotorRelativeSpin;rotorId;nodeA;nodeB;speedUnit;spinTableId;spinRate;rotorSuperelementId;node;massDampingFactor;stiffnessDampingFactor;viscousDampingFrequency;structuralDampingFrequency;hybridDampingFrequency

Position

Field

Type

Default

Meaning and conventions

1

rotorId

integer

Required

Identifier selecting the rotor record or set.

2

nodeA

integer

Required

Grid point identifier at connectivity position A.

3

nodeB

integer

Required

Grid point identifier at connectivity position B.

4

speedUnit

text

—

Unit used to express the specified speed.

5

spinTableId

integer

—

Table supplying the variation of spin. Alternative to spinRate.

6

spinRate

real

—

Angular speed of the rotating component. Alternative to spinTableId.

7

rotorSuperelementId

integer

0

Identifier selecting the rotor superelement record or set.

8

node

real

0.0

Grid point to which this entry applies.

9

massDampingFactor

real

0.0

Multiplier for mass damping.

10

stiffnessDampingFactor

real

0.0

Multiplier for stiffness damping.

11

viscousDampingFrequency

real

0.0

Viscous damping frequency (inverse time).

12

structuralDampingFrequency

real

0.0

Structural damping frequency (inverse time).

13

hybridDampingFrequency

real

0.0

Hybrid damping frequency (inverse time).

Accepted words: Constant, DesignDiscreteValues, Element, Frequency, RevolutionsPerMinute, Table.

Example record

RotorRelativeSpin;10;1001;1005;RevolutionsPerMinute;;1.;1

Model containing this record

Reading the example gives rotorId = 10, nodeA = 1001, nodeB = 1005, speedUnit = RevolutionsPerMinute.

RotorSuperelement

The rotor line model of a rotor that is placed in a superelement (the alternative to a RotorLineNodes when superelements are used).

Record format and fields

RotorSuperelement;id;superelementId;superelementOption

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

superelementId

integer

Required

Identifier of the superelement associated with the entry.

3

superelementOption

integer

1

Selects the superelement option for RotorSuperelement.

Accepted words: All, Constant, Element, Table, Through.

Example record

RotorSuperelement;10;1;2

Model containing this record

Reading the example gives id = 10, superelementId = 1, superelementOption = 2.

RotorTransientSpin

The spin rate of a rotor in a transient analysis, and the damping of the rotor.

Record format and fields

RotorTransientSpin;rotorId;nodeA;nodeB;speedUnit;spinTableId;speedOutput;rotorSuperelementId;node;massDampingFactor;stiffnessDampingFactor;viscousDampingFrequency;structuralDampingFrequency;hybridDampingFrequency

Position

Field

Type

Default

Meaning and conventions

1

rotorId

integer

Required

Identifier selecting the rotor record or set.

2

nodeA

integer

Required

Grid point identifier at connectivity position A.

3

nodeB

integer

Required

Grid point identifier at connectivity position B.

4

speedUnit

text

—

Unit used to express the specified speed.

5

spinTableId

integer

Required

Table supplying the variation of spin.

6

speedOutput

integer

0

Selects output of rotational speed data.

7

rotorSuperelementId

integer

0

Identifier selecting the rotor superelement record or set.

8

node

real

0.0

Grid point to which this entry applies.

9

massDampingFactor

real

0.0

Multiplier for mass damping.

10

stiffnessDampingFactor

real

0.0

Multiplier for stiffness damping.

11

viscousDampingFrequency

real

0.0

Viscous damping frequency (inverse time).

12

structuralDampingFrequency

real

0.0

Structural damping frequency (inverse time).

13

hybridDampingFrequency

real

0.0

Hybrid damping frequency (inverse time).

Accepted words: Constant, Element, Frequency, RevolutionsPerMinute, Table.

Example record

RotorTransientSpin;10;1001;1005;RevolutionsPerMinute;401;4001

Model containing this record

Reading the example gives rotorId = 10, nodeA = 1001, nodeB = 1005, speedUnit = RevolutionsPerMinute.

RotordynamicParams

The parameters of a rotordynamic analysis.

Record format and fields

RotordynamicParams;id;synchronous;referenceRotorId;speedUnit;speedLow;speedHigh;speed;rotorSuperelementId;viscousDampingFrequency;structuralDampingFrequency;hybridDampingFrequency

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

synchronous

text

—

Selects operation synchronized to the reference rotational frequency.

3

referenceRotorId

integer

Required

Identifier selecting the reference rotor record or set.

4

speedUnit

text

—

Unit used to express the specified speed.

5

speedLow

real

0.0

Minimum rotational speed in the selected range.

6

speedHigh

real

99999.0

Maximum rotational speed in the selected range.

7

speed

real

0.0

Speed (length per time).

8

rotorSuperelementId

integer

0

Identifier selecting the rotor superelement record or set.

9

viscousDampingFrequency

real

0.0

Viscous damping frequency (inverse time).

10

structuralDampingFrequency

real

0.0

Structural damping frequency (inverse time).

11

hybridDampingFrequency

real

0.0

Hybrid damping frequency (inverse time).

Accepted words: AsynchronousWhirl, Constant, Element, Frequency, RevolutionsPerMinute, SynchronousWhirl, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the ID must be a positive integer.

  • speedLow — the speeds must be finite numbers.

  • viscousDampingFrequency — the whirl frequencies must be finite numbers.

Example record

RotordynamicParams;500;AsynchronousWhirl;20;RevolutionsPerMinute;;;3.E+3;0

Model containing this record

Reading the example gives id = 500, synchronous = AsynchronousWhirl, referenceRotorId = 20, speedUnit = RevolutionsPerMinute.

StochasticParams

The statistics used to randomize selected model parameters.

Record format and fields

StochasticParams;id;<randomGroups>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group randomGroups. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

flag

text

—

Selects the option associated with this field in the current record or block.

2

distribution

text

—

Selects the distribution used for the input data or response.

3

variationCoefficient

real

—

Coefficient in the relation for variation.

4

standardDeviations

real

—

M: the number of standard deviations, greater than 0.

Accepted words: ConnectivityEntries, Constant, Element, EnforcedMotionConstr, Gauss, LoadEntries, MaterialEntries, PropertyEntries, Table.

Example record

StochasticParams;10;PropertyEntries;Gauss;0.05;3.;MaterialEntries;Gauss;0.03;2.

Model containing this record

Reading the example gives id = 10.

SuperelementReferenceRotor

The reference rotor of the non-reference rotors of any superelement, for a complex eigenvalue analysis.

Record format and fields

SuperelementReferenceRotor;id;referenceRotorId;referenceSuperelementId;<rotors>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Set identifier shared by entries in the same group.

2

referenceRotorId

integer

Required

Identifier selecting the reference rotor record or set.

3

referenceSuperelementId

integer

0

Identifier selecting the reference superelement record or set.

Repeated group rotors. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

nonFollowingRotorId

integer

—

Identifier selecting the non following rotor record or set.

2

nonFollowingSuperelementId

integer

—

Identifier selecting the non following superelement record or set.

Accepted words: Constant, Element, Frequency, RevolutionsPerMinute, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • nonFollowingRotorIds — the card needs at least one non-reference rotor.

Example record

SuperelementReferenceRotor;500;20;0;10;1

Model containing this record

Reading the example gives id = 500, referenceRotorId = 20, referenceSuperelementId = 0.

TimeToSpectrum

The conversion of time histories to power spectral densities, the Fast Fourier Transformation that a random vibration fatigue analysis uses when its loads are given as time signals.

Record format and fields

TimeToSpectrum;id;samplingRate;window;fileFormat;meanStress;skipCount;<keyed sections>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

samplingRate

real

Required

Samples per second.

3

window

text

HanningWindow

Selects the window applied to the sampled signal.

4

fileFormat

text

CommaSeparatedFile

Encoding of the external file identified by this entry.

5

meanStress

text

No

Average stress about which the alternating stress varies.

6

skipCount

integer

0

Number of skip entries.

Keyed sections in sections

Begin each section with its key, then write its fixed fields and any counted list.

Section Event

Repeated group events. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

eventId

integer

—

Identifier selecting the event record or set.

2

sliceTime

real

—

Slice time (time).

3

sliceDuration

real

—

Length of the time window used for one slice of the signal.

Section Delete

Repeated group deletions. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

eventId

integer

—

Identifier selecting the event record or set.

2

sliceStart1

real

—

Start of time slice 1 in the evaluation history.

3

sliceEnd1

real

—

End of time slice 1 in the evaluation history.

4

sliceStart2

real

—

Start of time slice 2 in the evaluation history.

5

sliceEnd2

real

—

End of time slice 2 in the evaluation history.

6

sliceStart3

real

—

Start of time slice 3 in the evaluation history.

7

sliceEnd3

real

—

End of time slice 3 in the evaluation history.

Section Map

Repeated group channels. Give the number of entries before their values.

Position

Field

Type

Default

Meaning and conventions

1

loadCaseId

integer

—

Identifier selecting the load case record or set.

2

channel

integer

—

Channel of the external data file supplying the sampled history.

Accepted words: CommaSeparatedFile, Constant, Delete, Element, Event, HanningWindow, LoadHistoryFile, Map, No, None, Table, Yes.

Example record

TimeToSpectrum;10;256.;HanningWindow;CommaSeparatedFile;No;0;Event;1;13;1.;0.5;Map;1;1;1

Model containing this record

Reading the example gives id = 10, samplingRate = 256., window = HanningWindow, fileFormat = CommaSeparatedFile.

TireSelection

The selection of the external tire models that take part in a simulation.

Record format and fields

TireSelection;id;tireFileKeyword;<tires>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

tireFileKeyword

text

—

Keyword selecting the associated tire data in the external file.

Repeated group tires. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

tireName

text

—

Text naming the tire.

Accepted words: Constant, Element, ExternalTireModel, Table.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • tireNames — the card needs the name of at least one tire.

Example record

TireSelection;100;ExternalTireModel;WHEELFL;WHEELFR;WHEELRL;WHEELRR

Model containing this record

Reading the example gives id = 100, tireFileKeyword = ExternalTireModel.

TransferPathSetup

The set-up of a transfer path analysis (TPA).

Record format and fields

TransferPathSetup;id;nodeSetId;unit;<responses>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

nodeSetId

integer

—

Identifier of the set supplying the grid points.

3

unit

integer

24

Logical unit or measurement convention as defined by the record.

Repeated group responses. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

responseKind

text

—

Selects the response kind for responses.

2

outputSet

integer

—

A TypedListSet3 of the response grid points, required.

Accepted words: Constant, Element, Table.

Example record

TransferPathSetup;100;1001;;A;2002

Model containing this record

Reading the example gives id = 100, nodeSetId = 1001.

TransientTimeSteps

The time steps of a linear transient analysis.

Record format and fields

TransientTimeSteps;id;<intervals>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

Repeated group intervals. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

stepCount

integer

—

Number of step entries.

2

timeStep

real

—

Time increment between successive states, in model time units.

3

outputInterval

integer

—

Spacing between successive output requests.

Reader diagnostics

The following messages identify invalid input for the applicable field or form.

  • id — the ID must be a positive integer.

  • stepCounts — Ni must be a positive integer.

Example record

TransientTimeSteps;61;50;1.E-4;5

Model containing this record

Reading the example gives id = 61.

UserFileName

Associates a file path with an identifier that other records use to locate external data.

Record format and fields

In the source layout, the form is called nameOnFirstLine when field 2 of the old layout is filled. Its compact field sequence is the one shown below.

Forms: nameOnSecondLine.

UserFileName: nameOnSecondLine

Form nameOnSecondLine, for every compact record.

UserFileName;id;entryName

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

entryName

text

—

File name or path associated with this file identifier. Written as one text field.

Accepted words: Constant, Element, Table.

Example record

UserFileName;1;road-loads.rsp

Model containing this record

WettedElemNodes

A wetted element of an external fluid-structure simulation, given by its shape and its grid points.

Record format and fields

WettedElemNodes;id;kind;node1;node2;node3;node4;node5;node6;node7;node8

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

kind

text

—

Selects the kind for WettedElemNodes.

3

node1

integer

—

Grid point to which this entry applies. Entry 1.

4

node2

integer

—

Grid point to which this entry applies. Entry 2.

5

node3

integer

—

Grid point to which this entry applies. Entry 3.

6

node4

integer

—

Grid point to which this entry applies. Entry 4.

7

node5

integer

—

Grid point to which this entry applies. Entry 5.

8

node6

integer

—

Grid point to which this entry applies. Entry 6.

9

node7

integer

—

Grid point to which this entry applies. Entry 7.

10

node8

integer

—

Grid point to which this entry applies. Entry 8.

Accepted words: Constant, Element, Line2Nodes, Line3Nodes, Quad4Shape, Quad8Shape, Table, Tria3Shape, Tria6Shape.

Example record

WettedElemNodes;103;Quad4Shape;4;5;8;7

Model containing this record

Reading the example gives id = 103, kind = Quad4Shape, node1 = 4, node2 = 5.

WettedElemSide

A wetted element of an external fluid-structure simulation, given as a side of a structural element.

Record format and fields

WettedElemSide;id;elemId;sideCode

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

elemId

integer

Required

Identifier of the element addressed by this record.

3

sideCode

integer

Required

Selects one side of the join, element or interface in the record’s local ordering.

Accepted words: Constant, Element, Table.

Example record

WettedElemSide;101;1;1

Model containing this record

Reading the example gives id = 101, elemId = 1, sideCode = 1.

WettedSurface

A wetted surface of a fluid-structure co-simulation, a list of wetted elements.

Record format and fields

WettedSurface;id;wettedTag;<wettedElems>

Position

Field

Type

Default

Meaning and conventions

1

id

integer

Required

Identifier in the namespace of this card type.

2

wettedTag

text

—

Tag identifying the surface exposed to the coupled fluid.

Repeated group wettedElems. Repeat these fields in order for each entry.

Position

Field

Type

Default

Meaning and conventions

1

wettedElemId

any

—

Identifier selecting the wetted element record or set.

Accepted words: By, Constant, Element, Table, Through.

Example record

WettedSurface;1;plate;101;Through;104

Model containing this record